Files
spinifex/scripts/reset-dev-env.sh
T
joshsiv-mulga abd93098fc fix: persist veth-wan pair across reboot (mulga-998.b Fix 1)
setup-ovn.sh's veth branch creates veth-wan-br ↔ veth-wan-ovs but nothing
recreates the kernel interfaces on reboot. OVSDB remembers veth-wan-ovs
as a port on br-ext but the peer is gone — the external path silently
breaks and vpcd falls through to direct mode.

- setup-ovn.sh: write /etc/systemd/network/15-spinifex-veth-wan.{netdev,network}
  in the veth branch so systemd-networkd recreates the pair on boot. Add
  a single pre-case guard that rips down stale veth persistence + the OVS
  port + the kernel veth whenever WAN_BRIDGE_MODE != veth, so mode
  transitions are idempotent (D17).
- reset-dev-env.sh: delete the netdev/network units during cleanup so
  `make reset` gives a truly clean slate.
- spinifex-vpcd.service: After=systemd-networkd.service openvswitch-switch.service
  so vpcd's sanity checks see a populated kernel + OVSDB (D5).
2026-04-24 12:37:01 +10:00

312 lines
11 KiB
Bash
Executable File

#!/bin/bash
# Reset dev environment (will purge all data)
# This script is for single-node dev environments only.
set -euo pipefail
CONFIG_FILE="$HOME/spinifex/config/spinifex.toml"
# --- Guard: refuse to run on multi-node clusters ---
if [ -f "$CONFIG_FILE" ]; then
NODE_COUNT=$(grep -cE '^\[nodes\.[^.]+\]' "$CONFIG_FILE")
if [ "$NODE_COUNT" -gt 1 ]; then
echo "❌ Multi-node cluster detected ($NODE_COUNT nodes in $CONFIG_FILE)."
echo " This script only supports single-node dev environments."
echo " Reset each node individually or use 'spx admin cluster shutdown'."
exit 1
fi
fi
# Save region from existing config before we delete everything
REGION="ap-southeast-2"
if [ -f "$CONFIG_FILE" ]; then
SAVED_REGION=$(grep -E '^\s*region\s*=' "$CONFIG_FILE" | tail -1 | sed 's/.*=\s*"\(.*\)"/\1/')
if [ -n "$SAVED_REGION" ]; then
REGION="$SAVED_REGION"
fi
fi
echo "Using region: $REGION"
# --- Shutdown services ---
echo "Shutting down services"
if ! ./scripts/stop-dev.sh; then
echo "❌ Failed to stop services. Aborting reset to prevent data loss."
exit 1
fi
# Verify no spinifex-related processes are still running
PROCESS_PATTERN='(bin/spx|spinifex-ui|nats-server|predastore|viperblock|vpcd)'
remaining=$(pgrep -af "$PROCESS_PATTERN" | grep -v "reset-dev-env.sh" || true)
if [ -n "$remaining" ]; then
echo "Waiting for remaining processes to exit..."
timeout=30
elapsed=0
while pgrep -af "$PROCESS_PATTERN" | grep -qv "reset-dev-env.sh" 2>/dev/null; do
if [ $elapsed -ge $timeout ]; then
echo "❌ Processes still running after ${timeout}s:"
pgrep -af "$PROCESS_PATTERN" | grep -v "reset-dev-env.sh" || true
echo " Kill them manually and re-run this script."
exit 1
fi
sleep 1
elapsed=$((elapsed + 1))
done
fi
# Verify no QEMU VMs are running
if pgrep -x qemu-system-x86_64 > /dev/null 2>&1; then
echo "❌ QEMU instances still running. Cannot reset while VMs are active."
echo " Run './scripts/stop-dev.sh' or kill them manually."
exit 1
fi
echo "All services confirmed stopped"
# --- Clean OVS/OVN ---
echo "Removing OVS bridges and config"
if command -v ovs-vsctl >/dev/null 2>&1; then
# Ensure OVS is running so we can clean up
sudo systemctl start openvswitch-switch 2>/dev/null || true
sleep 1
# Delete all OVS bridges (br-int, br-external, etc.)
for br in $(sudo ovs-vsctl list-br 2>/dev/null); do
echo " Deleting bridge: $br"
sudo ovs-vsctl --if-exists del-br "$br"
done
# Clear OVN external_ids
sudo ovs-vsctl --if-exists clear Open_vSwitch . external_ids 2>/dev/null || true
echo " Cleared OVS external_ids"
# Stop OVS again after cleanup
sudo systemctl stop openvswitch-switch 2>/dev/null || true
fi
# Clean OVN databases (both Northbound and Southbound)
# Delete the DB files outright — setup-ovn.sh will restart ovn-central with fresh
# empty databases. This eliminates stale SB state (chassis entries, port bindings,
# datapath bindings) that accumulates across resets and causes ovn-controller to
# enter a commit failure loop ("OVNSB commit failed, force recompute").
echo "Removing OVN database files"
sudo systemctl stop ovn-central 2>/dev/null || true
sudo systemctl stop ovn-controller 2>/dev/null || true
if [ -d /var/lib/ovn ]; then
sudo rm -f /var/lib/ovn/ovnnb_db.db /var/lib/ovn/ovnsb_db.db
echo " Deleted /var/lib/ovn/ovn{nb,sb}_db.db"
else
echo " /var/lib/ovn not found, skipping OVN DB cleanup"
fi
# Remove veth pair created by setup-ovn.sh (veth mode — Linux bridge ↔ OVS bridge)
if ip link show veth-wan-br >/dev/null 2>&1; then
echo " Deleting veth pair: veth-wan-br ↔ veth-wan-ovs"
sudo ip link del veth-wan-br 2>/dev/null || true
fi
# Remove veth persistence units (Fix 1, mulga-998.b). Without this, systemd-networkd
# recreates the veth on next reboot even after a full dev reset.
if [ -e /etc/systemd/network/15-spinifex-veth-wan.netdev ] || \
[ -e /etc/systemd/network/15-spinifex-veth-wan.network ]; then
echo " Deleting veth persistence units"
sudo rm -f /etc/systemd/network/15-spinifex-veth-wan.netdev \
/etc/systemd/network/15-spinifex-veth-wan.network
sudo networkctl reload 2>/dev/null || true
fi
# Remove macvlan interfaces created by setup-ovn.sh
for iface in $(ip -o link show type macvlan 2>/dev/null | awk -F': ' '{print $2}' | grep '^spx-ext-'); do
echo " Deleting macvlan: $iface"
sudo ip link del "$iface" 2>/dev/null || true
done
# --- Wipe data ---
echo "Removing ~/spinifex"
rm -rf ~/spinifex
# --- Re-initialize ---
# Detect WAN interface (default route).
WAN_IFACE=$(ip -4 route show default | awk '{print $5}' | head -1)
WAN_GW=$(ip -4 route show default | awk '{print $3}' | head -1)
echo "Detected WAN interface: ${WAN_IFACE:-none}, gateway: ${WAN_GW:-none}"
# Check if WAN interface is already a bridge (tofu-cluster / production setup).
# If so, setup-ovn.sh auto-detects it. If it's a physical NIC, we need to
# decide between direct bridge and macvlan based on SSH safety.
WAN_IS_BRIDGE=false
if [ -n "$WAN_IFACE" ]; then
if ip -d link show "$WAN_IFACE" 2>/dev/null | grep -q "bridge"; then
WAN_IS_BRIDGE=true
fi
fi
# Build setup-ovn.sh flags based on detected topology
SETUP_OVN_FLAGS=""
if [ "$WAN_IS_BRIDGE" = true ]; then
# WAN is already a bridge (e.g. br-wan from cloud-init) — setup-ovn.sh
# auto-detects it, no explicit flags needed.
echo " WAN is a bridge: $WAN_IFACE (auto-detected)"
elif [ -n "$WAN_IFACE" ]; then
# WAN is a physical NIC. Detect SSH NIC to decide bridge strategy.
SSH_NIC=""
if [ -n "${SSH_CONNECTION:-}" ]; then
SSH_IP=$(echo "$SSH_CONNECTION" | awk '{print $3}')
SSH_NIC=$(ip -o -4 addr show | awk -v ip="$SSH_IP" '$0 ~ ip"/" {print $2}' | head -1)
fi
if [ -z "$SSH_NIC" ]; then
SSH_NIC="$WAN_IFACE"
fi
if [ "$WAN_IFACE" != "$SSH_NIC" ]; then
SETUP_OVN_FLAGS="--wan-bridge=br-wan --wan-iface=$WAN_IFACE"
echo " Bridge mode: direct (WAN=$WAN_IFACE != SSH=$SSH_NIC)"
else
SETUP_OVN_FLAGS="--macvlan --wan-iface=$WAN_IFACE"
echo " Bridge mode: macvlan (WAN=$WAN_IFACE == SSH=$SSH_NIC)"
fi
fi
# Chassis ID — let setup-ovn.sh auto-detect from hostname. This ensures the
# system-id matches what ovn-controller registers in the SBDB, which is what
# vpcd discovers at startup for gateway scheduling.
echo "Re-initializing OVN"
./scripts/setup-ovn.sh --management $SETUP_OVN_FLAGS
echo "Initializing platform"
ADMIN_INIT_ARGS="--region $REGION --az ${REGION}a --node node1 --nodes 1"
# External networking mode: set EXTERNAL_MODE=nat for NAT/DHCP mode (outbound-only),
# or leave unset / EXTERNAL_MODE=pool for pool mode (per-VM public IPs).
EXTERNAL_MODE="${EXTERNAL_MODE:-pool}"
if [ -n "$WAN_IFACE" ] && [ -n "$WAN_GW" ]; then
WAN_IP=$(ip -4 -o addr show "$WAN_IFACE" 2>/dev/null | awk '{print $4}' | cut -d/ -f1 | head -1)
WAN_PREFIX=$(ip -4 -o addr show "$WAN_IFACE" 2>/dev/null | awk '{print $4}' | cut -d/ -f2 | head -1)
if [ -z "$WAN_PREFIX" ]; then WAN_PREFIX=24; fi
if [ "$EXTERNAL_MODE" = "nat" ]; then
# NAT mode: outbound-only via shared SNAT. Use a single IP from the
# high end of the WAN subnet as the gateway IP. No per-VM public IPs.
IFS='.' read -r o1 o2 o3 o4 <<< "$WAN_GW"
GATEWAY_IP="${GATEWAY_IP:-${o1}.${o2}.${o3}.200}"
echo " External mode: nat (gateway IP: $GATEWAY_IP, WAN gateway: $WAN_GW)"
ADMIN_INIT_ARGS="$ADMIN_INIT_ARGS --external-mode=nat --gateway-ip=${GATEWAY_IP} --external-gateway=${WAN_GW} --external-prefix-len=${WAN_PREFIX}"
else
# Pool mode: per-VM public IPs from a static range
IFS='.' read -r o1 o2 o3 o4 <<< "$WAN_GW"
POOL_START="${o1}.${o2}.${o3}.200"
POOL_END="${o1}.${o2}.${o3}.250"
echo " External pool: $POOL_START - $POOL_END (gateway: $WAN_GW)"
ADMIN_INIT_ARGS="$ADMIN_INIT_ARGS --external-mode=pool --external-pool=${POOL_START}-${POOL_END} --external-gateway=${WAN_GW} --external-prefix-len=${WAN_PREFIX}"
fi
fi
# Re-initialize with --force to regenerate credentials, certs, config, and
# update ~/.aws/credentials. Must carry the same args so external networking
# config isn't lost.
echo "Re-initializing platform..."
./bin/spx admin init --force $ADMIN_INIT_ARGS
# Generate SSH key if it doesn't exist
if [ ! -f ~/.ssh/spinifex-key.pub ]; then
echo "Generating SSH key pair..."
ssh-keygen -t ed25519 -f ~/.ssh/spinifex-key -N ""
fi
# Trust the Spinifex CA certificate so TLS connections to predastore/awsgw work
if [ -f "$HOME/spinifex/config/ca.pem" ]; then
echo "Adding Spinifex CA certificate to system trust store..."
sudo cp "$HOME/spinifex/config/ca.pem" /usr/local/share/ca-certificates/spinifex-ca.crt
sudo update-ca-certificates
fi
# Enable pprof for development
#PPROF_ENABLED=1 PPROF_OUTPUT=/tmp/spinifex-vm.prof ./scripts/start-dev.sh --build
./scripts/start-dev.sh --build
export AWS_PROFILE=spinifex
# Import SSH key
echo "Importing SSH key"
aws ec2 import-key-pair --key-name "spinifex-key" --public-key-material fileb://~/.ssh/spinifex-key.pub
aws ec2 describe-key-pairs
# Import AMI
echo "Importing AMI"
LOCAL_IMAGE="$HOME/images/ubuntu-24.04.img"
if [ -f "$LOCAL_IMAGE" ]; then
echo "Using local image: $LOCAL_IMAGE"
ARCH=$(uname -m)
if [ "$ARCH" = "aarch64" ] || [ "$ARCH" = "arm64" ]; then
IMG_ARCH="arm64"
else
IMG_ARCH="x86_64"
fi
./bin/spx admin images import --file "$LOCAL_IMAGE" --distro ubuntu --version 24.04 --arch "$IMG_ARCH"
else
# Download by name based on architecture
ARCH=$(uname -m)
if [ "$ARCH" = "x86_64" ]; then
IMAGE_NAME="ubuntu-24.04-x86_64"
elif [ "$ARCH" = "aarch64" ] || [ "$ARCH" = "arm64" ]; then
IMAGE_NAME="ubuntu-24.04-arm64"
else
echo "Warning: Unknown architecture $ARCH, defaulting to x86_64"
IMAGE_NAME="ubuntu-24.04-x86_64"
fi
echo "Downloading image: $IMAGE_NAME"
./bin/spx admin images import --name "$IMAGE_NAME"
fi
aws ec2 describe-images
# --- Launch a smoke-test instance ---
echo "Launching smoke-test instance..."
# Pick instance type based on CPU vendor
if grep -q 'AuthenticAMD' /proc/cpuinfo; then
INSTANCE_TYPE="t3a.small"
else
INSTANCE_TYPE="t3.small"
fi
# Get the AMI we just imported
AMI_ID=$(aws ec2 describe-images --query "Images[0].ImageId" --output text)
if [ -z "$AMI_ID" ] || [ "$AMI_ID" = "None" ]; then
echo "❌ No AMI found, skipping instance launch"
exit 0
fi
# Find a public subnet (first available)
SUBNET_ID=$(aws ec2 describe-subnets \
--filters "Name=map-public-ip-on-launch,Values=true" \
--query "Subnets[0].SubnetId" --output text 2>/dev/null)
# Fallback: just grab the first subnet if no public-tagged one exists
if [ -z "$SUBNET_ID" ] || [ "$SUBNET_ID" = "None" ]; then
SUBNET_ID=$(aws ec2 describe-subnets --query "Subnets[0].SubnetId" --output text)
fi
if [ -z "$SUBNET_ID" ] || [ "$SUBNET_ID" = "None" ]; then
echo "❌ No subnet found, skipping instance launch"
exit 0
fi
echo " AMI: $AMI_ID"
echo " Instance type: $INSTANCE_TYPE"
echo " Subnet: $SUBNET_ID"
INSTANCE_ID=$(aws ec2 run-instances \
--image-id "$AMI_ID" \
--instance-type "$INSTANCE_TYPE" \
--key-name spinifex-key \
--subnet-id "$SUBNET_ID" \
--count 1 \
--query 'Instances[0].InstanceId' --output text)
echo "✅ Reset complete — instance $INSTANCE_ID launched ($INSTANCE_TYPE)"