Multi-node install - Lead with the fact that the guide builds a three-node cluster, and say how to go beyond three. The callout sits inside ## Overview because the docs site discards everything above the first section heading. - Replace the OVN-only sizing prose with a table covering all three distributed layers, and move the OVN control-plane detail into the VPC networking guide, linked from here. - Add minimum and recommended hardware. - Move the object storage layout to the end as background; it was the second thing a reader hit. - Collapse the ISO conversion notes from a section into one skippable box, now that --force is unconditional in Step 4 and the formation port needs no manual intervention. - Expand verification with spx get nodes and spx top nodes, including what to look for in each. - Drop the install-node.sh shortcut (internal tooling) and the "adding a node later" section (no good story yet). Corrections found while writing - Servers 4+ were described as running no database. They run predastore and viperblock like every other node; only the OVN database cluster is capped at three. Fixed in four places. - Step 4 never needed the firewall down: spx admin init opens the formation port itself for the formation window. Only Step 3's peer-scoped OVN ports are affected. - `nft list table inet spinifex_filter | grep spinifex_peers` could never match — the peer list is an nft define, expanded at load time. Anyone following it would have seen empty output and assumed the worst. - Disambiguate "database": with predastore, NATS and OVN all in play it needed qualifying throughout. - Align the example output region with the AWS_REGION the guide exports. Cross-doc links - Rewrite relative and category-prefixed links to the canonical /docs/<slug> form. The site publishes docs flat, so ../foo/README.md and /docs/category/foo both 404. - Point the six links to unpublished docs at the source repo instead. - Fix four fragments written against GitHub's anchor algorithm.
230 lines
10 KiB
Markdown
230 lines
10 KiB
Markdown
---
|
|
title: "Host and Guest Lifecycle"
|
|
description: "The contract between Spinifex host service lifecycle events and running guest EC2 instances."
|
|
category: "Admin"
|
|
tags:
|
|
- lifecycle
|
|
- shutdown
|
|
- systemd
|
|
- guests
|
|
resources:
|
|
- title: "Spinifex Repository"
|
|
url: "https://github.com/mulgadc/spinifex"
|
|
- title: "Updating Spinifex"
|
|
url: "/docs/update"
|
|
---
|
|
|
|
# Host and Guest Lifecycle
|
|
|
|
> The contract between Spinifex host service lifecycle events and running guest EC2 instances.
|
|
|
|
## Table of Contents
|
|
|
|
- [Overview](#overview)
|
|
- [The Contract](#the-contract)
|
|
- [Older Releases: `systemctl stop spinifex.target`](#older-releases-systemctl-stop-spinifextarget)
|
|
- [Older Releases: A Local Drain Drained the Whole Cluster](#older-releases-a-local-drain-drained-the-whole-cluster)
|
|
- [Why Guests Outlive the Daemon](#why-guests-outlive-the-daemon)
|
|
- [Checking State](#checking-state)
|
|
- [Maintenance Runbooks](#maintenance-runbooks)
|
|
|
|
---
|
|
|
|
## Overview
|
|
|
|
`spinifex.target` groups every Spinifex service on a node: `spinifex-nats`,
|
|
`spinifex-predastore`, `spinifex-northstar`, `spinifex-viperblock`,
|
|
`spinifex-daemon`, `spinifex-awsgw`, `spinifex-vpcd`, `spinifex-ui`,
|
|
`spinifex-qmp-collector`, `spinifex-shutdown`, and the
|
|
`spinifex-nats-watchdog` timer. A guest EC2 instance is a `qemu-system-x86_64`
|
|
process launched by `spinifex-daemon` — it is not itself a systemd unit, and
|
|
it is deliberately allowed to keep running after the service that launched it
|
|
stops.
|
|
|
|
The one idea to hold onto: guests outlive the daemon by design, so what
|
|
happens to a running guest depends entirely on which lifecycle event
|
|
triggered the stop, not on whether "Spinifex" as a whole looks like it is
|
|
still running.
|
|
|
|
## The Contract
|
|
|
|
| Event | What happens to running guests | Is storage available afterwards | What the operator must do |
|
|
|---|---|---|---|
|
|
| Host `reboot` / `poweroff` / `halt` | Drained gracefully — QMP `system_powerdown`, volumes unmounted, WAL flushed — by `spinifex-shutdown.service`'s `ExecStop` | n/a, the host is going down | Nothing extra |
|
|
| `systemctl restart spinifex.target` | Survive. Not rebooted. Reattached over QMP by `Manager.Restore` when the daemon comes back | Yes, within seconds | Nothing extra — this is the supported way to pick up a config change |
|
|
| `systemctl stop spinifex.target` | Drained the same as a host shutdown, because nothing guarantees the stack comes back on its own | No, not until the stack is started again | Nothing extra — but see [Older Releases](#older-releases-systemctl-stop-spinifextarget) if the node predates this behaviour |
|
|
| `systemctl restart spinifex-daemon.service` (daemon only) | Survive via `KillMode=process`. Reattached by `Manager.Restore` | Yes, throughout | Nothing extra |
|
|
| Daemon crash / SIGKILL | Survive | Yes, throughout — the crash only takes down the daemon | Nothing — crash recovery reattaches automatically on the next daemon start |
|
|
| Host power loss | Die with the host. No drain is possible | No, until the host boots and services start again | Expect `Manager.Restore` to run crash recovery on boot. Guest filesystems may need an fsck the same as after any unclean power cut |
|
|
| `spx admin cluster shutdown` | Stopped in the DRAIN phase, before storage (STORAGE, PERSIST) and control-plane (INFRA) services stop | n/a, the cluster is being taken down | Nothing extra — this is the correct command for taking a whole cluster down |
|
|
|
|
## Older Releases: `systemctl stop spinifex.target`
|
|
|
|
> [!WARNING]
|
|
> **Releases from v1.15.0 up to the release carrying this page do NOT drain on a plain `systemctl stop spinifex.target`.** Running guests get no signal at all — no QMP `system_powerdown`, no SIGTERM. Predastore and viperblock stop underneath the guest, leaving it with no data path, while QEMU keeps running. Drives are launched with `cache=none,werror=report,rerror=report`, so I/O errors are reported into the guest instead of pausing it — the guest keeps running and keeps believing it has a disk. Anything written after storage goes away is lost, and a guest filesystem that takes I/O errors on its journal can be left inconsistent.
|
|
|
|
**Cause:** on those releases `spinifex-shutdown.service`'s `ExecStop` ran
|
|
`spx admin node drain --local --timeout=120s --only-if-host-stopping`, which
|
|
drains only when `systemctl is-system-running` reports the literal state
|
|
`stopping`. That is true for a real reboot/poweroff but not for a plain
|
|
`systemctl stop spinifex.target` — systemd reports `running` for both a plain
|
|
stop and the stop half of a restart, so the gate could not tell them apart. It
|
|
skipped the drain and logged `Host is not shutting down; skipping guest
|
|
drain.` The gate now also reads systemd's pending job list, which does
|
|
distinguish the two.
|
|
|
|
The fastest way to check is `spx admin upgrade --dry-run`, which reports every
|
|
unit's status against the one shipped in the running binary — including
|
|
`spinifex-shutdown.service` — without changing anything. See
|
|
[Checking for Unit Drift](/docs/admin/update#checking-for-unit-drift). A node
|
|
reported stale or missing for that unit predates this fix; reconcile it with
|
|
`sudo spx admin upgrade --units-only --yes` (this only rewrites the unit and
|
|
runs `daemon-reload` — it does not restart anything or drain guests itself).
|
|
|
|
To check by hand instead, look at the unit directly:
|
|
|
|
```bash
|
|
systemctl cat spinifex-shutdown.service | grep ExecStop
|
|
```
|
|
|
|
`--unless-restarting` drains on a plain stop; `--only-if-host-stopping` does
|
|
not. **On a node still showing `--only-if-host-stopping`, drain guests
|
|
explicitly before stopping the target.**
|
|
|
|
1. Stop the instances first, via the AWS-compatible API:
|
|
|
|
```bash
|
|
aws ec2 stop-instances --instance-ids i-0123456789abcdef0
|
|
```
|
|
|
|
Or run the drain command by hand on the node — invoked without a gate flag
|
|
it drains unconditionally:
|
|
|
|
```bash
|
|
sudo spx admin node drain --local
|
|
```
|
|
|
|
2. Confirm no guests are left running:
|
|
|
|
```bash
|
|
ps auxw | grep qemu-system
|
|
```
|
|
|
|
3. Only then stop the target:
|
|
|
|
```bash
|
|
sudo systemctl stop spinifex.target
|
|
```
|
|
|
|
This does not apply to `systemctl restart spinifex.target` — the restart row
|
|
in the contract table above is unaffected, since the same gate is what makes
|
|
guests survive a restart intact.
|
|
|
|
## Older Releases: A Local Drain Drained the Whole Cluster
|
|
|
|
> [!WARNING]
|
|
> **Releases up to the one carrying this section drain every node in the
|
|
> cluster when any single node stops its target.** Stopping or rebooting one
|
|
> node powers down every guest on every other node, stops their API gateway,
|
|
> UI and VPC daemon, and leaves each daemon refusing new work until it is
|
|
> restarted. On a multi-node cluster this reads as an unexplained cluster-wide
|
|
> outage triggered by routine single-node maintenance.
|
|
|
|
**Cause:** the local drain published its GATE and DRAIN requests to the shared
|
|
`spinifex.cluster.shutdown.*` subjects, which every daemon subscribes to as a
|
|
fan-out. The node filter applied only to the replies the stopping node waited
|
|
for, so the other nodes had already drained by the time it was applied.
|
|
Requests now name the node they apply to, and a daemon ignores one addressed
|
|
to another node.
|
|
|
|
Both ends have to be current for this to hold: the node that issues the drain
|
|
sends the target, and the nodes that receive it must be new enough to honour
|
|
it. A cluster mid-upgrade still drains cluster-wide from any node that has not
|
|
yet been updated. **Upgrade every node before relying on single-node
|
|
maintenance**, and until then stop guests deliberately rather than as a side
|
|
effect of stopping a target.
|
|
|
|
To check whether a cluster is exposed, confirm each node's `spx` is current:
|
|
|
|
```bash
|
|
spx version
|
|
```
|
|
|
|
## Why Guests Outlive the Daemon
|
|
|
|
`KillMode=process` is set on `spinifex-daemon.service` and
|
|
`spinifex-viperblock.service`. It tells systemd to signal only the unit's
|
|
main process and leave everything else in its cgroup alone, so guest QEMU
|
|
processes and any nbdkit backend still serving a guest survive a restart of
|
|
the service that spawned them. This is deliberate: a control-plane restart or
|
|
upgrade must never interrupt a customer workload just because the daemon that
|
|
launched it needed to bounce.
|
|
|
|
On the way back up, `Manager.Restore` reconnects to each surviving guest over
|
|
QMP rather than relaunching it, so the guest is never rebooted by a daemon or
|
|
target restart.
|
|
|
|
This is what makes the restart row in the contract table safe, and it holds
|
|
only as long as storage comes back with the daemon — a daemon-only restart
|
|
never takes predastore or viperblock down, and a target restart brings them
|
|
back within seconds. It does not hold for an event that leaves storage down
|
|
indefinitely, which is exactly the deviation described above.
|
|
|
|
## Checking State
|
|
|
|
```bash
|
|
# Service status for the whole stack
|
|
systemctl status spinifex.target
|
|
|
|
# Is systemd mid-shutdown, or just running?
|
|
systemctl is-system-running
|
|
|
|
# Any guest QEMU processes still alive
|
|
ps auxw | grep qemu-system
|
|
|
|
# Guest state as Spinifex sees it (node, status, health)
|
|
spx get vms
|
|
|
|
# EC2-API view of instance state
|
|
aws ec2 describe-instances
|
|
|
|
# Confirm whether the last target stop actually drained guests
|
|
journalctl -u spinifex-shutdown -b
|
|
# Look for: "Host is not shutting down; skipping guest drain."
|
|
```
|
|
|
|
## Maintenance Runbooks
|
|
|
|
### Apply a Config Change
|
|
|
|
1. Edit `/etc/spinifex/spinifex.toml`.
|
|
2. Apply it:
|
|
|
|
```bash
|
|
sudo systemctl restart spinifex.target
|
|
```
|
|
|
|
Guests survive this restart — they are not rebooted, and storage returns
|
|
within seconds. This is the supported way to pick up a config change; see
|
|
the restart row in [The Contract](#the-contract).
|
|
|
|
### Take a Node Down for Hardware Maintenance
|
|
|
|
1. Stop or reboot the host — both drain running guests first:
|
|
|
|
```bash
|
|
sudo systemctl stop spinifex.target # taking the node fully out of service
|
|
sudo reboot # or, for a reboot
|
|
```
|
|
|
|
2. Confirm nothing is left running:
|
|
|
|
```bash
|
|
ps auxw | grep qemu-system
|
|
```
|
|
|
|
The drain is automatic on both paths. Stop the instances yourself first only
|
|
if you want them to stay stopped when the node returns, or if the node still
|
|
runs an older build — see [Older Releases](#older-releases-systemctl-stop-spinifextarget)
|
|
above.
|