* feat: add GPU fields to NodeStatus and spx top nodes (mulga-996)
- Add TotalGPUs/AllocGPUs to NodeStatusResponse (zero on non-GPU nodes)
- Populate from gpuManager in handleNodeStatus
- Show GPU (used/total) column in spx top nodes; "-" when no GPUs present
* Fixed GPU passthrough and added test script
* feat: always-probe GPU at startup, surface capability in NodeStatusResponse
- Add gpuProbeResult struct and probeGPU() which runs at daemon startup
regardless of gpu_passthrough config. Checks sysfs for GPUs, IOMMU
groups, and vfio_pci module presence.
- Store gpuProbe on Daemon struct; split NewDaemon into probe (always)
and activate (opt-in) phases.
- Populate GPUCapable, GPUPassthrough, GPUModels on NodeStatusResponse
so operators can see hardware state before enabling passthrough.
- Update 'spx top' GPU column: '-' = no hardware, '0/N*' = capable but
passthrough not active, 'used/total' = passthrough active.
* feat: SIGHUP hot-reload for GPU passthrough config (mulga-1001)
- Export GenerateGPUTypes for use by the reload path
- Add ResourceManager.reloadGPUTypes: mutates instanceTypes map in-place
(preserves references held by instanceService) and updates NATS
subscriptions without full daemon restart
- Separate SIGHUP from SIGTERM/SIGINT: setupReload() listens for SIGHUP
in a context-aware loop; setupShutdown no longer intercepts SIGHUP
- Add reloadConfig() + applyGPUConfig(): re-reads spinifex.toml on signal,
handles false→true (re-probe + activate) and true→false (refuse if
instances running, otherwise deactivate) transitions
* installer grub image fixes
* made gpu-passthrough more user facing
* vpcd fixes to set br-wan to promisc for public IP DHCP processes
* fixed vpcd br-wan promisc and veth pair
* ssh keygen fix
* Fix: AMD GPU edge cases
* script for running 8x instances on SMCI computer
* fix: increase disk space on instances
* feat: multi-GPU passthrough support for g7e.12xlarge (2× MI350X)
- vm.VM: GPUPCIAddress string → GPUPCIAddresses []string for multi-GPU
- instancetypes: add g7e.12xlarge (2 GPUs), GPUCountForType(), AMDmi350x model
- instancetypes/generate: use GPUCountForType for GpuInfo.Count and TotalGpuMemoryInMiB
- gpu/manager: Release() loops all pool entries for instanceID (not just first)
- vm/lifecycle: loop over GPUPCIAddresses, emit gpu0/gpu1/... QEMU devices
- daemon/handlers: claim N GPUs in loop for both RunInstances and StartStoppedInstance
- daemon/vm_adapters: ReclaimByAddress loops GPUPCIAddresses; ReleaseGPU checks len > 0
- scripts/launch-gpu-fleet: fixed fleet — 6× g7e.4xlarge + 1× g7e.12xlarge
* feat: per-instance-type disk size in GPU fleet (300 GB single, 600 GB dual)
* fix: multi-gpu instance types
* fix: kill QEMU synchronously when QMP handshake fails to free VFIO device
When startQEMU succeeds but newQMPClientWithHandshake times out, the
instance has not yet been inserted into the manager map so vmMgr.Delete
in the rollback path is a no-op. QEMU keeps running and holds the VFIO
group open. The GPU pool entry gets freed, the next Claim returns the
same PCI address, and every subsequent QEMU fails with 'device or
resource busy'.
Fix: SIGKILL QEMU and wait for it to exit before returning the QMP
error, ensuring the VFIO device is released before the caller recycles
the GPU pool slot.
* fix: quarantine GPU after QEMU launch failure to prevent re-assignment cascade
When QEMU crashes during startup (e.g. pci_irq_handler assertion on a
specific GPU), the pool Release frees that address and the next NATS
request immediately re-claims the same broken device. Add MarkFailed()
to gpu.Manager which sets Available=false for a PCI address after a
launch failure, preventing re-assignment until the daemon restarts.
Call MarkFailed for each GPU address in both RunInstances and
StartStoppedInstance rollback paths after the Release succeeds.
* fixed instance fleet launch script
* remove known hosts and stagger provisioning
* improvements to launch script
* more upgrades
* single instance gpu instance provisioning
* fixed single instance provision
* smci computer demo dashboard
* fixes to launch script
* updated smci dashboard_server
* fixed demo dashboard
* updated dashboard.py
* feat: GPU Passthrough fixes to passthrough process - builds proper AMD or NVIDA ready images, generalised launch script
* feat: gpu-passthrough updating image builder to include gpu-ready ubuntu images
* fixing image builder process
* fixed image builder to remove /tmp/ file before import to free space
* fix: Updated COMMANDS.md to reflect new GPU management admin commands
* Update docs, update internal launch script to work with new SGs, test tweaks
* Updated Docs, fixed internal launch-gpu.sh script, test tweaks
* fxing CI race due to GPU load
* refactor(daemon): extract Describe instance handlers to service (1b-pre phase 1)
Collapse the Describe family in daemon_handlers_instance.go to thin Pattern A
wrappers over a transport-neutral InstanceServiceImpl. This brings the read
path in line with the rest of the codebase and is the prerequisite for 1b's
local HTTP API (mulga-siv-14, daemon-local-autonomy plan).
Extracted: DescribeInstances, DescribeInstanceTypes, DescribeInstanceAttribute,
DescribeStoppedInstances, DescribeTerminatedInstances. Filter helpers
(instanceMatchesFilters, matchTagKey/Value, DescribeInstancesValidFilters,
IsInstanceVisible) move to the instance package alongside the service methods.
InstanceService gains the new methods and two dep interfaces
(ResourceCapacityProvider, StoppedInstanceStore) so the daemon's ResourceManager
and JetStreamManager can plug in without leaking concrete types. NATSInstanceService
returns a clear error for the fan-out describes (DescribeInstances,
DescribeInstanceTypes) since cluster-wide aggregation lives in the gateway's
scatter-gather helpers, not a single-node NATS request.
Behaviour changes: malformed JSON on DescribeInstanceAttribute now responds
with ValidationError (matching every other Pattern A handler) instead of
ServerInternal. Test updated.
Mutators (RunInstances, ModifyInstanceAttribute, StartStoppedInstance,
TerminateStoppedInstance, sub-handlers) remain Pattern B for now; follow-up
phases of mulga-siv-14 will collapse them.
* feat(daemon): local-first instance state persistence (1a)
Make /var/lib/spinifex/state/instance-state.json the source of truth for a
node's VMs; JetStream KV becomes a best-effort cluster cache. The daemon now
survives KV unavailability without losing instance state.
- New local_state.go: atomic write (tmp+fsync+rename), schema_version gate,
missing-file = fresh install, corrupt = refuse start.
- Daemon.WriteState writes the local file under Instances.Mu, then calls
jsManager.WriteStateBestEffort with a 1s timeout. KV failures log and
continue; clients never see "KV down" during partition.
- Daemon.LoadState reads from the local file only — no KV fallback (a fresh
node has empty KV anyway, so silent fallback would mask bugs).
- restoreInstances now returns error and Start() aborts on corrupt local
state rather than silently starting empty.
- jsManager.WriteState no longer self-locks (caller holds Mu); added
WriteStateBestEffort and shared marshalInstanceState helper.
Reconnect-driven KV resync deferred to siv-16 (1c owns the callback wiring).
Bead: mulga-siv-15
Plan: docs/development/feature/daemon-local-state-persistence.md
* fix(daemon): root local state at DataDir not BaseDir
LocalStatePath was falling back to BaseDir when DataDir was empty, putting
the file at /var/lib/spinifex/spinifex/state/instance-state.json (under the
daemon's own subdir) instead of the documented
/var/lib/spinifex/state/instance-state.json (the platform-shared root).
Drop the BaseDir fallback. Empty DataDir resolves to DefaultDataDir
(/var/lib/spinifex). Tests now set DataDir alongside BaseDir on their config
fixtures.
* feat(daemon): graceful NATS disconnect/reconnect handling (1c)
Daemon now flips a `mode` field (cluster|standalone) on NATS
disconnect/reconnect via optional callback hooks added to
utils.ConnectNATS. Reconnect bumps natsRetryCount and triggers 1a's
full local-state push to KV. NATSRequest/NATSScatterGather fail fast
with ErrClusterUnavailable when the connection is down. Gateway
short-circuits NATS-bound requests with a 503 ServiceUnavailable
carrying "cluster unavailable: NATS disconnected — check daemon
/local/status" so AWS clients see the failure mode immediately
instead of hanging on per-call timeouts.
Plan: docs/development/feature/daemon-autonomy-1c-disconnect.md
* fix(gateway): SigV4 middleware short-circuits on NATS disconnect
The 1c gateway.Request() IsConnected check (gateway.go:234) was
unreachable for any authenticated path because SigV4 auth middleware
runs first and calls IAMService.LookupAccessKey over JetStream KV. With
NATS down the lookup hangs ~5s on context.DeadlineExceeded and the
gateway returns 500 InternalError. AWS SDK retries it twice for ~18s of
user-visible latency instead of the <100ms 503 promised by the 1c plan.
Mirror the IsConnected check at the top of SigV4AuthMiddleware (after
credential parse so malformed auth headers still get the right SigV4
error code, before the IAM lookup). The catch-all in gateway.Request()
stays as defence-in-depth for any future unauthed paths.
Coverage debt picked up alongside: 1c utils.NATSRequest /
NATSScatterGather fail-fast paths, daemon Mode/onNATSDisconnect/
onNATSReconnect/localStatePath/Write/LoadState branches, and 1b-pre
InstanceServiceImpl Describe* methods (partial siv-22).
Bead: mulga-siv-23
* feat(daemon): read-only /local/* HTTP API (1b)
Wires GET /local/instances, GET /local/instances/{id}, GET /local/status
onto the existing ClusterManager TLS listener so observers can read this
node's instance state and connectivity mode while NATS is unreachable.
Also fixes a pre-existing race in WriteState: json.Marshal walked shared
*vm.VM pointers from SnapshotMap while concurrent TransitionState calls
mutated VM fields under the manager lock. Marshal now runs inside
vmMgr.View; WriteLocalStateBytes / WriteStateBytesBestEffort accept the
pre-marshalled JSON and commit lock-free. TestTransitionState_Concurrent
Transitions is race-clean across 30 iterations.
Adds Daemon.stateRevision (atomic.Uint64) bumped on every successful
local-state write, surfaced as /local/status.revision so observers can
detect changes without diffing payloads.
* feat(daemon): two-phase startup — survive NATS down (1d)
Split daemon Start() into startLocal() (HTTPS, mgmt bridge, OVS plumber,
OOM, local state load — no NATS) and startCluster() (background, infinite
retry exp backoff cap 60s for NATS connect, then JetStream + services +
restoreInstances + subscribeAll + heartbeat). Daemon never process-exits
on NATS failure; instead it stays up in standalone mode and reconnects in
the background.
Drop ExecStartPre=wait-for-nats.sh from spinifex-daemon.service — local
bootstrap no longer requires NATS to be reachable.
ConnectNATSWithRetry now supports infinite retry (WithMaxWait(0)),
context cancellation (WithContext), per-attempt error callback for the
nats_retry_count operator signal on /local/status, and a configurable
backoff cap (WithMaxRetryDelay).
bead: mulga-siv-17 (closes)
* feat(daemon): Tier 1 invariant guard for cluster-scoped service init (1e-audit)
Make the DDIL §1e-audit invariant explicit: startLocal must not initialise any
NATS-dependent or JetStream-KV-backed handle. Adds assertNoClusterServicesInitialised
as a runtime guard at the end of startLocal that fails fast if a future edit
hoists a cluster-scoped service into Phase 1, plus comment blocks naming the
invariant on both startLocal and startCluster.
Code audit confirms the existing 1d split already keeps every cluster-scoped
bucket out of Phase 1; this change pins the property so it cannot regress
silently. Tier table for the 25 daemon-process KV buckets is finalised in
docs/development/feature/daemon-local-autonomy.md §1e-audit.
bead: mulga-siv-19 (closes)
* feat(daemon): NATS observability hardening (1d-obs)
Closes the residual visibility gap left by the 1d non-blocking startup:
- Extend /local/status with kv_sync_failures, last_kv_sync_at,
last_kv_sync_error so an operator polling the local API sees prolonged
divergence between the local file and JetStream KV.
- Add a KVSyncObserver interface on JetStreamManager so the daemon can
count best-effort write outcomes without coupling the manager to
daemon state.
- Escalate utils.ConnectNATSWithRetry per-attempt log to slog.Error
(rate-limited to once per minute, with disconnected_for context) once
attempt count crosses the natsRetryEscalateAttempt threshold (~30
attempts ≈ ~30 min disconnected at the 60s backoff cap), so a stuck
NATS config surfaces in error logs instead of routine warn noise.
Prometheus metrics export deferred until a system-wide telemetry plan
(likely OTel) lands; the structured /local/status fields plus the
escalated retry log cover the Tier 1 visibility gap.
* feat(daemon): opt-in SPINIFEX_REQUIRE_NATS strict-startup mode (1d-strict)
When SPINIFEX_REQUIRE_NATS=1, startCluster's first NATS connect uses a
bounded ~30s retry and the daemon aborts on timeout. Default behaviour
(env unset) keeps the Tier 1 infinite-retry path so prod / edge nodes
still survive a missing NATS at boot. Restores pre-DDIL fail-fast UX
for dev / test / single-node deploys without flipping the prod default.
mulga-siv-44.
* test(scripts): systemd-level smoke for DDIL phase 1
Bash harness exercising daemon-local-autonomy on a real `make deploy` node:
baseline cluster mode → kill spinifex-nats → assert standalone + retry
counter advance + /local/instances served → restart NATS → assert mode flip
+ KV resync stamp → SPINIFEX_REQUIRE_NATS=1 bounded-exit. Cleanup trap
restores both services. Complements existing unit coverage by validating
real systemd wiring on port 8443.
* fix(test-ddil): daemon ClusterManager binds 4432 not 8443
8443 is predastore. Daemon's HTTPS ClusterManager (where /local/* lives)
binds [nodes.node1.daemon].host = 0.0.0.0:4432 in the deployed config.
Plan doc daemon-local-autonomy.md:112 incorrectly said 8443; actual code
uses d.config.Daemon.Host.
* fix(test-ddil): correct retry-counter site + bypass NATS Wants= for strict test
Two bugs in the v1 script:
1) nats_retry_count assertion ran during disconnect — but the counter
only bumps on disconnect→reconnect *cycles* (daemon.go:321,
onNATSReconnect). Moved assertion to step 3 (restart NATS) where
the reconnect callback fires.
2) Step 4 stopped spinifex-nats then ran 'systemctl restart
spinifex-daemon' — but the daemon unit's Wants=spinifex-nats.service
re-pulled NATS up via the Wants= chain, so the strict-mode 30s
timeout never fired. systemctl mask refuses on /etc-installed
units, and --runtime mask is shadowed by /etc. Block via a runtime
drop-in with ConditionPathExists=! pointing at a sentinel file.
Verified: all 5 checks pass on a single-node make deploy box; daemon
exits 32s after restart with SPINIFEX_REQUIRE_NATS=1 + NATS blocked.
* fix(admin): render data_dir into spinifex.toml so non-root nodes write local state
Pseudo-multinode E2E (rootless tf-user, ~/nodeN data roots) hit
"mkdir /var/lib/spinifex/state: permission denied" on every RunInstances:
Config.DataDir was empty because the template never emitted a data_dir
key, and LocalStatePath fell back to DefaultDataDir (/var/lib/spinifex).
Surfaced after 8eb9c5fa dropped the BaseDir fallback in LocalStatePath —
previously SPINIFEX_BASE_DIR=$DATA_DIR/spinifex/ (set by start-dev.sh)
masked the missing data_dir.
ConfigSettings.DataDir is already populated to spxRoot at admin
init/join; render it under [nodes.X] so it actually reaches the daemon.
* feat: add GPU discovery package (mulga-992)
Adds spinifex/gpu package with sysfs-based GPU enumeration, IOMMU group
member lookup, and a PCI device ID model table. Vendor-specific enrichment
via nvidia-smi is attempted opportunistically and falls back to the built-in
table when unavailable. All discovery and IOMMU logic is covered by unit tests
using mock sysfs trees.
* feat: add VFIO bind/unbind and GPU pool manager (mulga-993)
Adds gpu.BindVFIO/UnbindVFIO using sysfs driver_override for per-device
driver switching, and gpu.Manager which owns the claim/release lifecycle
for the GPU pool including full IOMMU group binding, rollback on partial
failure, and marking entries unavailable when rebind fails after VM
termination.
* feat: add G5 instance type generator with GPU model support (mulga-994)
- Add GPUModel type, NVIDIAa10g constant, and GPUModelForVendorDevice lookup
- Add generateGPUTypes to emit g5.* types with GpuInfo populated
- Add IsGPUType helper for consumers filtering GPU-capable types
- Update DetectAndGenerate to accept gpuModels []GPUModel parameter
* feat: integrate GPU passthrough into daemon lifecycle (mulga-995)
- Add gpu_passthrough config flag; discover GPUs and build manager at startup
- Gate g5 instance types on GPU pool availability via canAllocateCount
- Claim GPU (VFIO bind) in LaunchInstance; inject vfio-pci QEMU device
- Release GPU (VFIO unbind, rebind to host driver) in stopInstance
- Re-claim GPU on daemon restart when QEMU process is still alive
- Add UseUEFI / OVMF support for x86_64 VMs (optional, falls back to SeaBIOS)
- Fix Claim to use stored OriginalDriver when device is already vfio-pci bound
* feat: add GPU fields to NodeStatus and spx top nodes (mulga-996)
- Add TotalGPUs/AllocGPUs to NodeStatusResponse (zero on non-GPU nodes)
- Populate from gpuManager in handleNodeStatus
- Show GPU (used/total) column in spx top nodes; "-" when no GPUs present
* feat: Ubuntu 24.04 GPU AMI build pipeline (mulga-997)
Extends build-system-image.sh to support Ubuntu alongside Alpine.
Key differences handled: partition table (parted resizepart p1),
bind mounts for DKMS (/proc /sys /dev), apt vs apk, systemctl vs
rc-update. DISTRO defaults to "alpine" for backward compatibility.
Adds ubuntu-gpu.conf manifest and ubuntu-gpu-setup.sh chroot script
that installs nvidia-headless-550-server with DKMS pre-built against
a pinned linux-image-generic kernel, blacklists nouveau, and prevents
unattended-upgrades from invalidating the pre-built module.
* Fixed GPU passthrough and added test script
* feat: always-probe GPU at startup, surface capability in NodeStatusResponse
- Add gpuProbeResult struct and probeGPU() which runs at daemon startup
regardless of gpu_passthrough config. Checks sysfs for GPUs, IOMMU
groups, and vfio_pci module presence.
- Store gpuProbe on Daemon struct; split NewDaemon into probe (always)
and activate (opt-in) phases.
- Populate GPUCapable, GPUPassthrough, GPUModels on NodeStatusResponse
so operators can see hardware state before enabling passthrough.
- Update 'spx top' GPU column: '-' = no hardware, '0/N*' = capable but
passthrough not active, 'used/total' = passthrough active.
* feat: SIGHUP hot-reload for GPU passthrough config (mulga-1001)
- Export GenerateGPUTypes for use by the reload path
- Add ResourceManager.reloadGPUTypes: mutates instanceTypes map in-place
(preserves references held by instanceService) and updates NATS
subscriptions without full daemon restart
- Separate SIGHUP from SIGTERM/SIGINT: setupReload() listens for SIGHUP
in a context-aware loop; setupShutdown no longer intercepts SIGHUP
- Add reloadConfig() + applyGPUConfig(): re-reads spinifex.toml on signal,
handles false→true (re-probe + activate) and true→false (refuse if
instances running, otherwise deactivate) transitions
* feat: spx admin gpu status/enable/disable commands (mulga-1000)
- admin.SetGPUPassthrough: Go implementation of the idempotent TOML write
(replaces the inline Python heredoc in spx-test-gpu.sh)
- spx admin gpu status: shows GPU hardware, IOMMU/vfio state, passthrough
activation, and advertised g5 instance types via NATS NodeStatusResponse
- spx admin gpu enable: checks prerequisites, writes TOML, sends SIGHUP,
polls until daemon confirms GPUPassthrough=true
- spx admin gpu disable: refuses while GPU instances are running, otherwise
writes TOML, sends SIGHUP, polls until confirmed
- spx-test-gpu.sh: replace Python TOML heredoc with spx admin gpu enable
* fixed admin
* fix: filter Intel iGPU from passthrough pool, use lspci for consumer GPU names
Discover() now skips non-NVIDIA/AMD vendors so Intel iGPUs never enter
the passthrough pool. enrichFromLspci() uses the system PCI ID database
via lspci -vmm to populate the model name for any card not in the
hardcoded table, without needing nvidia-smi or driver tools.
* fix: grant CAP_SYS_ADMIN and vfio device access to spinifex-daemon
GPU passthrough requires writing to /sys/bus/pci/drivers/vfio-pci/unbind
on instance stop. The kernel gates this on CAP_SYS_ADMIN regardless of
file permissions. QEMU subprocesses also need char-vfio rw access to
open /dev/vfio/N for the passed-through device.
* fixing gpu bining permissions
* working state of gpu passthrough on phyiscal box
* installer grub image fixes
* made gpu-passthrough more user facing
* fixed banner
* fixed banner
* banner fix
* gpu passthrough docs
* preflight tweak
* vpcd fixes to set br-wan to promisc for public IP DHCP processes
* fixed vpcd br-wan promisc and veth pair
* ssh keygen fix
* fixes after running /review-branch
* feat: re-wire GPU claim and device injection after vm.Manager refactor
GPU passthrough claim (VFIO bind) and QEMU device injection were lost
when dev's vm.Manager refactor (#185/#186) moved StartInstance/
CreateQMPClient into vm/lifecycle.go. Re-add both in their correct
new homes:
- daemon_handlers_instance.go: claim GPU before vmMgr.Run() in both
RunInstances and StartStoppedInstance handlers; release on failure
- vm/lifecycle.go startQEMU(): inject vfio-pci device with x-vga flag
derived from instance.GPUXVGAEnabled when GPUPCIAddress is set
* fix: Create spinifex user ~/.ssh and keys in firstboot
---------
Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com>
Co-authored-by: Julian Sommer <115516918+juliansommer@users.noreply.github.com>
Playbooks for preflight / teardown / install / reset covering the same
ground as dev-install.sh, dev-setup.sh, reset-dev-env.sh. Existing bash
scripts untouched — decide which to keep after parity testing.
- roles/teardown + teardown catalog README track every known state
source; add a task + row when a leak is reported.
- roles/init gates smoketest on awsgw readiness (describe-regions poll).
- roles/smoketest is dup-tolerant, retry-wrapped, auto-terminates the
launched instance.
- dev-install.yml skips build/install/init when a healthy environment
is already present (4-signal health check), always runs smoketest.
- dev-reset.yml captures region/az/external-mode scalars from the
existing spinifex.toml and replays them into init.
Plan: docs/development/improvements/ansible-dev-lifecycle.md (mulga).
Bead: mulga-siv-9.
* fix(installer): emit kernel cmdline to ttyS0 alongside tty0 (mulga-siv-33)
GRUB_CMDLINE_LINUX in /etc/default/grub only listed console=tty0, so the
installed kernel printed nothing on serial after the GRUB menu. Headless
installs (CI, racks with serial-only IPMI, remote-dev SSH-to-QEMU) saw a
black screen forever and had no path to debug boot failures.
Append console=ttyS0,115200 — the last `console=` on the cmdline becomes
the system console, so ttyS0 wins on serial-only hardware while tty0
still receives output on local displays.
Plan: docs/development/bugs/iso-public-ip-boot-race.md
* fix(ipam): widen vpc.dhcp.acquire retry budget to 60 s (mulga-siv-34)
ObtainDHCPLease retried only 5 attempts × 1 s before returning a hard
error. On a cold ISO boot, NATS comes up well before vpcd's reconcile
leader-election + dhcp.Manager subscribe (typical 5–30 s, pathological
~60 s during full reconcile), so daemon's NewExternalIPAM races vpcd's
dhcp.acquire subscription and fails permanently — d.externalIPAM stays
nil for the daemon's lifetime, daemon_handlers_instance.go silently
skips all auto-public-IP allocation, and instances launch with no
public IP, no dnat_and_snat, and no NAT event ever published.
Bump maxAttempts to 60 with 1 s spacing; expose both as package vars
so tests can shrink the budget for fast timeout-path coverage. Pure
widening of the existing retry loop — no behaviour change on the
success path, only the worst-case wallclock when vpcd never comes up.
The dominant cause of slow vpcd starts (mulga-siv-33: systemd-networkd
not enabled in the ISO → veth pair vanishes on reboot → vpcd
crashloops) is fixed alongside this. A 60 s budget fits comfortably
above all observed healthy-startup times.
Plan: docs/development/bugs/iso-public-ip-boot-race.md
* fix(setup-ovn): declare Linux WAN bridge as NetDev so networkd-managed veth resolves Bridge= on reboot (mulga-siv-33)
The veth-mode reboot persistence drop-ins added in mulga-998.b were
incomplete: setup-ovn.sh wrote `15-spinifex-veth-wan.network` with
`Bridge=br-wan`, but never declared br-wan itself to networkd.
br-wan is created by `networking.service` (ifupdown via
`/etc/network/interfaces`, generated by `install.go writeNetworkConfig`),
not networkd. networkd's `Bridge=` directive requires the target to be a
known NetDev — when it isn't, networkd silently logs
`br-wan NetDev could not be found, ignoring assignment` and the veth
ends up with no master. vpcd's bridge-mode sanity check then fails on
every reboot.
Fix: also write `14-spinifex-br-wan.netdev` declaring br-wan as
`Kind=bridge`. networkd matches the existing kernel bridge by name+kind
(the `Failed to create netdev: File exists` log is harmless), and
`Bridge=br-wan` resolves on next boot. ifupdown still owns DHCP and the
IP — networkd just needs the NetDev declaration to enslave the veth.
The write is gated to avoid clobbering operator-managed networkd config:
if any other `.netdev` under `/etc/systemd/network`,
`/run/systemd/network`, or `/usr/lib/systemd/network` already declares
the WAN bridge by name, the write is skipped with a log line pointing
at the operator file. Cleanup hook also removes the new file when
switching away from veth mode.
Verified end-to-end via QEMU repro: clean install + first boot + reboot,
veth-wan-br master persists across reboots, vpcd starts cleanly.
* fix(vpcd/dhcp): enable AF_PACKET promisc on bridge for DORA (mulga-siv-33)
Real-world DHCP servers commonly ignore the BOOTP BROADCAST flag and
reply with a unicast OFFER addressed to the synthetic per-tenant chaddr
(e.g. 02:f3:...). A Linux bridge floods unknown unicast to slave ports
but does NOT pass it up to the bridge netdev unless IFF_PROMISC is set,
so vpcd's AF_PACKET socket on br-wan misses the OFFER and DORA times
out at 15s ("unable to receive an offer: context deadline exceeded").
Dev/CI didn't hit this:
- CI uses spx_wan_mode=static — no DORA via vpcd.
- QEMU dev DHCP servers (SLIRP/dnsmasq) honor the BROADCAST flag, so
their replies are L2 broadcast which the bridge always passes up.
Replace the three nclient4.New(iface, ...) call sites in Acquire/Renew/
Release with nclient4.NewWithConn(...) wrapping a custom AF_PACKET
DGRAM conn that calls SetPromiscuous(true). Promisc is per-socket
(per-DORA, ~15s) and refcounted by the kernel — auto-clears on close.
* revert(vpcd/dhcp): drop AF_PACKET promisc wrapper, restore nclient4.New
ecfbd4f swapped nclient4.New for openPromiscBridgeConn + NewWithConn to
catch unicast OFFER replies that bypass the bridge netdev. On dev hosts
where upstream honors the BOOTP BROADCAST flag, the wrapper regressed
DORA — public-IP allocation failed where main works. Reverting until
the promisc path is validated against both broadcast- and unicast-OFFER
servers.
* fix(setup-ovn): mark br-int/br-ext Unmanaged for systemd-networkd (mulga-siv-37)
Fresh ISO install on Trixie+systemd-networkd left the OVS internal netdevs
admin-down: networkd has no matching .network so it tags them as unmanaged
but never brings them up. OVS dataplane works but ovn-controller flow
programming and any tooling that probes link state misbehaves.
Drop /etc/systemd/network/05-spinifex-ovs-internal.network with
Unmanaged=yes so OVS itself owns the link state — `ovs-vsctl add-br`
already runs the netdev up at create time.
* fix(vpcd): allocate gateway LRP IP from pool in centralized NAT (mulga-siv-36)
In veth/macvlan modes the gateway LRP carries all egress, so it must hold
a WAN-subnet IP — otherwise the upstream router silently drops ARP for
the WAN nexthop (RFC 826) and the default route never resolves. The
hardcoded 169.254.0.1/30 was correct for distributed NAT but regressed
centralized NAT (introduced under mulga-siv-26).
Add gw_lrp_range_start/end to ExternalPool. In centralized mode at IGW
attach the gateway LRP gets a fresh IP from that range, persisted as
external_ids:spinifex:gateway_ip on the LRP for idempotent reconcile and
retrofit. Direct mode keeps link-local. Per-VM EIP allocator skips the
gw range; ValidatePoolConfig rejects overlap with the EIP range.
Adds TestTopologyHandler_IGWAttach_CentralizedNATAllocatesGwLrpIP and
extends RetrofitAllGatewayPortNetworks to migrate stale link-local LRPs
to allocated pool IPs at startup.
* fix(vpcd): drop link-local fallback, auto-derive gw_lrp_range (mulga-siv-36)
In centralized NAT (veth/macvlan) the gateway LRP must hold a WAN-subnet
IP — link-local cannot ARP-resolve the upstream nexthop, so the upstream
router silently drops egress. Hardware deployment confirmed the previous
fallback to 169.254.0.1/30 was always reached when gw_lrp_range was not
explicitly configured.
Auto-derive a 16-IP range at the top of the WAN subnet (broadcast - 16
.. broadcast - 1) when gw_lrp_range is unset; shift below RangeStart on
overlap with the per-VM EIP range; clamp inside the subnet; guard the
upstream gateway IP. IGW attach now errors out instead of falling back
to link-local when allocation fails — surfaces misconfiguration loudly.
Adds focused unit tests for gwLrpRange, ValidatePoolConfig and
nextAvailableExternalIP gw-lrp skip; updates the multi-VPC and
PoolWithGatewayIP regression tests.
* feat(vpcd): DHCP-acquire gateway LRP IPs (mulga-siv-38)
Per-VPC OVN gateway LRPs now obtain their WAN-subnet IP via vpc.dhcp.acquire
when the pool is source="dhcp", instead of carving from a static gw_lrp_range.
The upstream DHCP server becomes the single arbiter of LAN address space; a
cluster grows by N nodes without operator-side range carving in spinifex.toml.
- Consolidate ObtainDHCPLease/ReleaseDHCPLease into the dhcp package as
RequestAcquire/RequestRelease so vpcd and the daemon-side ExternalIPAM
share one helper. handlers/ec2/vpc keeps its existing ENI/EIP DHCP path.
- TopologyHandler dispatches by pool source: DHCP pools call DHCPManager
via NATS (client-id "gw-lrp-<vpcId>", idempotent on retry); static pools
keep the siv-36 gw_lrp_range / auto-derive allocator. Direct mode and
no-pool deployments still use link-local.
- IGW detach issues vpc.dhcp.release so the upstream server reclaims the
IP. Best-effort — server-side expiry is the safety net.
- Tests: TestTopologyHandler_IGWAttach_DHCPGwLrpIP (3 VPCs share one DHCP
pool, distinct IPs, idempotent attach, release on detach),
IGWAttach_DHCPAcquireFailureAborts (no link-local fallback when DHCP
errors), TestPrefixFromMask. Existing static / auto-derive tests
preserved.
* fix(vpcd): subscribe DHCPManager before reconcile to fix boot race (mulga-siv-38)
DHCPManager.Subscribe ran AFTER ReconcileFromKV / RetrofitAllGatewayPortNetworks,
so retrofit's vpc.dhcp.acquire requests for existing IGWs hit "no responders" and
burned the 60-attempt × 1 s cold-boot retry budget per VPC before failing. On a
dev box with one bootstrap VPC the symptom is a 60 s vpcd startup hang followed
by "allocate gw LRP IP failed", and the bootstrap IGW topology missing from OVN
until the next reconcile pass.
Move dhcpManager.Subscribe ahead of the two reconcile passes so the subscription
is live before any topology code can fan out an acquire.
* fix(vpcd): also subscribe DHCPManager before bootstrap reconcile pass
Previous fix moved DHCPManager.Subscribe ahead of ReconcileFromKV but
missed Pass 1 (the bootstrap-config Reconcile that runs even earlier).
On a dev box with a source="dhcp" pool and a bootstrap IGW, that earlier
pass still hit "no responders" and burned the 60-retry cold-boot budget
before the Manager came up. Move both reconcile passes after Subscribe.
* fix(vpcd): RFC 2131 §4.1 DORA exponential backoff (mulga-siv-39)
DHCPManager.Acquire previously did one DISCOVER and gave up after 15s
because the outer ctx.WithTimeout matched the per-attempt timeout —
nclient4's WithRetry(3) could never fire. Real DHCP servers (consumer
routers, ISC dhcpd, dnsmasq) silently drop OFFERs under load; the spec
mandates retransmission with exponential backoff, and a single lost
DISCOVER was killing legitimate boots.
Move retransmission into DHCPManager.acquireWithBackoff with a
4s/8s/16s/32s schedule (±1s jitter, ~60s worst case). NClient4Client
becomes single-attempt; manager owns retry policy. Default
acquireTimeout lifts from 15s to 90s (sum of schedule + slack).
* fix(vpcd): retry NewDHCPManager on JetStream-not-ready (mulga-siv-40)
NewDHCPManager creates the spinifex-dhcp-leases KV bucket via
utils.GetOrCreateKVBucket → js.CreateKeyValue with no retry. After the
mulga-siv-38 launchService reorder, this runs before any other JetStream
user, so on multi-node cold-boot vpcd hits "JetStream system temporarily
unavailable" and exits before cluster quorum forms. Pseudo-multinode CI
calls start_node_services sequentially, so node2's vpcd failure aborts
the script before node3 ever launches and quorum then never forms.
Wrap NewDHCPManager in newDHCPManagerWithRetry (500ms→10s, 5 min cap,
ctx-cancellable) mirroring daemon.initJetStream so vpcd waits as
patiently as the daemon for the cluster to come up.
* fix(daemon): idempotent DetachVolume QMP path (mulga-siv-41)
DetachVolume's QMP sequence was not retry-safe. First call: device_del
succeeds, blockdev-del fails with "Node nbd-vol-X is in use" because NBD
client teardown / in-flight I/O still hold the block node. Handler bails
ServerInternal "leaving volume state intact" but the guest device is
actually gone. AWS-CLI retries: device_del returns DeviceNotFound,
handler bails again. After 2 retries aws cli exits 254 — Single-Node
Phase 8 Step 3 reproducibly fails this way.
Phase 1: treat DeviceNotFound on device_del as already-detached, log and
continue. Detach is now idempotent across retries.
Phase 2: tryBlockdevDel polls blockdev-del up to 20×detachDelay on "in
use" errors so the I/O drain can complete instead of failing the whole
detach. Other QMP errors fall through immediately as before.
- workflows: add 'dev' to push/PR triggers (spinifex.yml, ui.yml, e2e.yml)
- workflows: drop "Resolve Mulga Branch" fallback step; mulga is single-branch
so checkout@v6 uses the default branch implicitly
- dependabot: route gomod/github-actions/npm PRs to dev
- diff-coverage.sh: pick origin/dev as base for feat branches, origin/main for dev
- iac/proxmox-template: default git_branch to dev for cluster builds
Refs docs/development/improvements/reintroduce-dev-branch.md
bc33c72 added the mask but placed it after the SKIP_APT early-return.
CI bootstrap runs setup.sh with INSTALL_SPINIFEX_SKIP_APT=1 against
runners that already have dhcpcd-base, so the mask never ran. On
Debian-13 the auto-enabled dhcpcd.service kept binding br-wan and
racing vpcd's nclient4, reproducing the mulga-siv-32 DORA timeout
on the public-IP allocation path. Lift the disable+mask out of the
apt branch so it runs unconditionally.
* preflight tweak
* fix: pin gateway LRP to link-local, end intra-cluster ARP collision
Every VPC's IGW gateway-LRP claimed pool.GatewayIP || pool.RangeStart on
attach. Multi-VPC clusters all GARP'd the same .160 with three different
deterministic MACs on the shared br-ext localnet, flapping the upstream
ARP cache and dropping 100% of inbound traffic to dnat_and_snat external
IPs (mulga-siv-26).
handleIGWAttach and reconcileIGW now unconditionally set the gateway
router port to 169.254.0.1/30. The default route's OutputPort already
pins the LRP, so the WAN nexthop need not be on-subnet. Pool IPs stay
allocated only for per-VM dnat_and_snat external addresses, which are
unique by construction.
Self-heal: RetrofitAllGatewayPortNetworks runs at startup and rewrites
stale Networks in place via the new UpdateLogicalRouterPort path. Needed
because Reconcile gates IGW work on "ext switch missing", so a cluster
shipped with the buggy CIDR never re-enters reconcileIGW.
Regression guards: TestTopologyHandler_IGWAttach_MultiVPC_NoIPCollision
and TestReconcileIGW_RewritesStaleGatewayPortNetworks. Existing tests
updated to assert link-local and OutputPort=&gwPortName. Log field
gateway_ip renamed to lrp_network to signal the semantic shift.
* fix: rewrite utils.HashMAC to SHA-256 / 46-bit output
The old 24-bit rolling hash with literal class prefix had birthday-paradox
collision probability of 1% at ~580 ids and 50% at 4096 — well within the
range of a single deployment's resource population (LRPs, ENIs, dev/mgmt
NICs). On a shared L2 segment, two clusters could trivially produce
duplicate MACs, breaking neighbour discovery and DHCP.
Switch HashMAC to SHA-256 across the entire input, taking the low 6 bytes
and forcing the IEEE 802 reserved bits (bit0=0 unicast, bit1=1 LAA) on the
first octet. Output entropy goes from 24 bits to 46 bits — 1% collision
boundary moves from ~580 to ~1.2M ids.
Drop the redundant prefix arg: it was no longer the literal output prefix
under the new scheme, just folded into the hash input. Class disambiguation
moves to the caller, where it's explicit. Three of four callers had nothing
to disambiguate (eni-, subnet-, gw-vpc- ids are already unique); dev and
mgmt NICs share instance.ID and now compose "dev:" / "mgmt:" tags.
Also consolidate vpcd.generateMAC, which was a local duplicate of the
broken algorithm rather than a HashMAC wrapper, into a HashMAC delegation.
Plan: docs/development/bugs/vpcd-mac-collisions-shared-l2.md
Bead: mulga-siv-27
* fix: pin HashMAC first octet to 0x02
Previous impl forced only the IEEE 802 reserved bits (bit0=0 unicast,
bit1=1 LAA) on the first octet, leaving the upper 6 bits hash-derived.
Technically valid LAA unicast, but produced MACs like 4a:.. and fe:..
that visually encroach on vendor OUI space and tripped CI/ops checks
expecting all generated MACs to start with 02:.
Pin byte 0 to literal 0x02; hash bytes 1-5 from sha256[0:5]. Output
entropy drops from 46 to 40 bits — birthday-paradox 1% collision at
~150k ids, still 256x the old 24-bit bound (~580).
* chore(e2e): dump cross-chassis OVN state on guest SSH failure
Adds chassis registrations, port_binding claims, gateway_chassis rows,
ovs-vsctl topology, Geneve tunnel state, and br-int tunnel flows to
dump_guest_ssh_diagnostics so we can pinpoint where the cross-chassis
dataplane stalls (cr-gw chassis vs remote chassis with the VM bound).
* fix: gate vpcd startup reconcile behind NATS KV leader election
N vpcds in a multi-node cluster all hit Get-then-Create on Logical_Router
with no atomicity, producing duplicate rows that ovn-nbctl rejects with
"Multiple logical routers named '...'. Use a UUID."
Add AcquireReconcileLeader using NATS KV CAS (kv.Create on a single key
in spinifex-vpcd-reconcile bucket). Only the elected vpcd runs Reconcile,
ReconcileFromKV, and the two retrofit passes — others Subscribe and rely
on the vpcd-workers queue group for runtime events. MaxAge=60s on the
bucket caps recovery time when a leader crashes mid-reconcile.
Falls through (elected=true) when KV is unavailable so first-boot does
not deadlock on a missing JetStream.
mulga-siv-29
* fix(elbv2): force mgmt host route for internal-scheme LBs (mulga-siv-30)
Single-node CI e2e Phase 3b ALB internal hangs in 'provisioning' for 270s
because the lb-agent inside the ALB VM has no return path to AWSGW.
The gateway-URL decision tree in daemon.wireLBAgentConfig picks advertiseIP
for single-node and deliberately skips adding the /32 mgmt host route — the
WAN-return-path concern in the comment is real but applies only to
internet-facing LBs, which have an EIP and an OVN dnat_and_snat pair that
gives reply traffic a way home. Internal LBs have no EIP / no SNAT, so when
the agent dials advertiseIP the reply targets the VM's private subnet IP from
the host's WAN with no route back.
Make lbVMUserData scheme-aware. New helper resolveMgmtRoute returns the
existing (MgmtRouteGateway, MgmtRouteTarget) when set (multi-node case) and
falls back to (MgmtBridgeIP, AdvertiseIP) when scheme is internal — only
internal LBs need the /32 route, so internet-facing single-node still gets
no bootcmd and the host-initiated WAN path stays clean.
Daemon now exposes MgmtBridgeIP and AdvertiseIP unconditionally so the
fallback has the inputs it needs.
* fix(daemon): stub sudoCommand in TestSetupComputeNode_ValidatesArgs (mulga-siv-31)
The test was calling real SetupComputeNode("chassis-test", ...) which shelled
out via sudoCommand to set external_ids:system-id=chassis-test on the host's
live OVS. On a dev box with OVS installed this overwrote the persistent UUID
(owned by openvswitch-switch and re-applied only on reboot), so vpcd's
discoverChassis filtered out the legitimate SBDB chassis row as 'stale local'
and crashlooped — taking out all VPC ops including ALB ENI provisioning.
Bind sudoCommand to a var so tests can swap it. Stub it in the test to return
exec.Command("/bin/false") and assert SetupComputeNode returns an error. The
test's intent (signature + error-path coverage) is preserved; nothing on the
host is touched.
* chore(vpcd): log DHCP Acquire concurrency + duration (mulga-siv-32)
Diagnostics-only change to surface whether nightly e2e cell-3 / cell-8
DORA timeouts correlate with concurrent Acquire calls on the same
bridge. Tracks per-bridge in-flight count and wallclock duration of each
Acquire; logs WARN on failure with both fields, DEBUG on success.
No behavioural change.
* ci(e2e-nightly): dump cluster journals on failure (mulga-siv-32)
run-multinode-e2e.sh dumps node journals via its own EXIT trap, but
run-cert-e2e.sh / run-lb-e2e.sh / reboot-e2e do not. When those scripts
fail the cluster is destroyed in Teardown without surfacing any daemon
logs, blocking root-cause analysis.
Add a workflow step that runs after the test scripts but before
Teardown when a previous step failed, ssh'ing to each node and pulling
the last 200 lines of every spinifex-* unit. Best-effort: skips
gracefully when inventory or nodes are unreachable.
Diagnostic-only; no behavioural change to the test path.
* fix(setup): mask dhcpcd.service to stop it racing vpcd's DHCP client (mulga-siv-32)
Debian 13 (Trixie) auto-enables a standalone dhcpcd.service when
dhcpcd-base is installed. It binds br-wan and races vpcd's in-process
nclient4 client for upstream OFFERs, draining the lab DHCP pool with
duplicate leases and causing intermittent DORA timeouts in the e2e
public-IP path (worst on cell-8 real-multi/dhcp/debian-13).
The ISO installer already masks the unit at install time
(cmd/installer/install/install.go:316). The binary install path used by
e2e nightly missed it, so debian hosts installed via setup.sh ran with
both DHCP clients live. Mirror the ISO mask here.
Ubuntu hosts are unaffected (dhcpcd-base does not auto-enable
dhcpcd.service on Noble).
* ci(e2e-nightly): also dump dhcpcd.service state on failure (mulga-siv-32)
Confirms or rules out the dhcpcd-vs-vpcd race hypothesis. Pulls the
dhcpcd.service journal alongside the spinifex-* units, plus
systemctl is-enabled / is-active and the DHCP client port (UDP 68)
listener so we can see directly whether dhcpcd is running and bound
to br-wan when an Acquire times out.
---------
Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com>
Three minimal edits to close the orphan-OVS-port failure mode that
survives PR1a's systemd ordering fix (host crash, OOM-kill of ovsdb,
operator manually stopping OVS on a live host) and the
terminate-during-pending race that leaks taps when a user aborts a
slow launch.
1. SetupTapDevice (network.go): unconditional `ovs-vsctl --if-exists
del-port br-int <tap>` + separately-gated kernel `ip tuntap del`.
The previous kernel-side-gated cleanup missed orphan OVS ports
because OVS conf.db survives reboot while kernel taps don't.
Rejected `--may-exist add-port`: it would silently keep stale
external_ids:iface-id/attached-mac from a prior launch.
2. stopInstance mgmt-tap branch (daemon.go) + CleanupMgmtTapDevice
(network.go): derive the mgmt tap name from instance.ID rather
than reading instance.MgmtTap, since that field is set only after
SetupMgmtTapDevice returns and a terminate racing mid-launch
would skip cleanup. CleanupMgmtTapDevice gains a kernel-presence
short-circuit so unconditional invocation doesn't log spurious
"Device does not exist" errors for instances that never reached
SetupMgmtTapDevice.
3. LaunchInstance (daemon.go): `launchStillValid` helper re-checks
instance status before StartInstance and TransitionState, in
addition to the entry guard. On detection of shutting-down /
terminated, log Info and return nil — the concurrent terminate
goroutine owns cleanup; this is an expected race outcome, not an
error. Removes the spurious "Failed to transition instance to
running" ERROR that surfaced on every legitimate
terminate-during-pending. Plus the entry path now returns nil
instead of an error for the same reason.
Also lands `scripts/start-then-terminate-pending.sh` (added during
investigation) which reproduces the runtime race for manual
verification.
Bead: mulga-siv-20.2
Plan: docs/development/bugs/orphan-tap-on-launch-race.md (PR1b)
Fix 1 persisted the veth pair across reboot via
15-spinifex-veth-wan.{netdev,network}, but only configured
veth-wan-br. Its peer veth-wan-ovs had no .network unit, so
networkd left it unmanaged and admin-DOWN after reboot. That
cascades: peer goes LOWERLAYERDOWN, br-wan loses carrier,
external DHCP/NAT path broken — despite vpcd correctly
detecting mode=veth and the sanity check passing.
OVS does not admin-up external (non-internal) ports — that's
networkd's job. Pre-reboot the setup-ovn.sh 'ip link set
veth-wan-ovs up' made it work, but that doesn't persist.
Write a second unit 16-spinifex-veth-wan-ovs.network with
ConfigureWithoutCarrier=yes so networkd flips admin state
without taking ownership of bridge/address assignment (OVS
retains that). Cleanup paths in the non-veth branch of
setup-ovn.sh and reset-dev-env.sh updated to remove the new
unit too.
Verified live via 'networkctl reload': veth-wan-ovs and
veth-wan-br both UP, br-wan LOWER_UP. Reboot drill per
docs/development/bugs/dhcp-vpcd-issues.md 'Live drill 1'
still required to confirm persistence.
setup-ovn.sh's veth branch creates veth-wan-br ↔ veth-wan-ovs but nothing
recreates the kernel interfaces on reboot. OVSDB remembers veth-wan-ovs
as a port on br-ext but the peer is gone — the external path silently
breaks and vpcd falls through to direct mode.
- setup-ovn.sh: write /etc/systemd/network/15-spinifex-veth-wan.{netdev,network}
in the veth branch so systemd-networkd recreates the pair on boot. Add
a single pre-case guard that rips down stale veth persistence + the OVS
port + the kernel veth whenever WAN_BRIDGE_MODE != veth, so mode
transitions are idempotent (D17).
- reset-dev-env.sh: delete the netdev/network units during cleanup so
`make reset` gives a truly clean slate.
- spinifex-vpcd.service: After=systemd-networkd.service openvswitch-switch.service
so vpcd's sanity checks see a populated kernel + OVSDB (D5).
* fix: provision br-mgmt as OVS bridge + loopback guard for LB gateway
Convert br-mgmt from an externally-provisioned Linux bridge to an OVS
bridge owned by scripts/setup-ovn.sh, giving every deployment type
(tofu-cluster, production single-node, production multi-node) a single
provisioning path.
setup-ovn.sh grows --mgmt-bridge / --mgmt-cidr / --mgmt-iface /
--no-mgmt-bridge flags. Default creates br-mgmt with fail-mode=standalone
(excluded from ovn-bridge-mappings so ovn-controller ignores it) and
assigns the mgmt IP via a systemd-networkd drop-in so it survives reboot.
SetupMgmtTapDevice / CleanupMgmtTapDevice switch from `ip link master`
to `ovs-vsctl add-port` / `del-port` to match the new bridge type.
Add a loopback guard to wireLBAgentConfig's fallback branch: on a
production single-node with awsgw bound to 127.0.0.1 and no mgmt bridge,
the fallback previously injected 127.0.0.1 into LB VM cloud-init —
silently unreachable because the VM's loopback is its own. The guard
leaves GatewayURL empty and the existing "LB agent gateway URL not
configured" error fires instead. Regression covered in
daemon_wire_lb_test.go.
* fix: auto-detect primary IP for admin init --bind default
Bare `spx admin init` used a 127.0.0.1 default that kept awsgw on loopback
only, so system VMs on br-mgmt could never reach it. Auto-detect the
default-route source IPv4 instead, which keeps TLS cert SANs specific
(still not a wildcard). Dev-install scripts now pass --bind 127.0.0.1
explicitly to preserve loopback-only behavior on laptops.
Closes mulga-siv-7.
* test: refresh wire lb loopback-bind comment for siv-7
* fix: dev-install scripts should let admin init auto-detect --bind
Pinning --bind to 127.0.0.1 on dev installs left awsgw loopback-only while
setup-ovn.sh still provisions br-mgmt, so LB VMs hit 10.15.8.1:9999 with
no listener. Drop the explicit --bind so auto-detect picks the primary IP
and the siv-6 mgmtRouteVia path routes LB traffic to a real listener.
* fix: bind awsgw and predastore on 0.0.0.0 in spinifex.toml template
PR #144 (nats TLS) made every service listen on --bind's specific IP. For
awsgw and predastore this broke localhost-reachability that the UI proxy
(spinifexui/spinifexui.go:193-194) and AWS CLI spinifex profile rely on —
latent since #144, surfaced by siv-7's auto-detect default on dev installs
(502 from the UI).
Hardcode awsgw and predastore host fields to 0.0.0.0 so both listen
wildcard; loopback clients (UI proxy, spinifex AWS CLI profile, same-host
daemon → predastore) keep working, LAN clients still reach them via the
LAN-IP SAN on the cert. daemon.host and nats.host stay as {{.BindIP}}
because peer-advertised values must not resolve to 0.0.0.0/loopback.
predastore.host normalization at config.go:207 rewrites 0.0.0.0 → 127.0.0.1
for local-node consumers, so existing callers see a usable connect address.
* revert: siv-7 --bind auto-detect + siv-6 loopback guard (prep mulga-siv-8)
Clears the deck before layering the listen-vs-advertise split
(mulga-siv-8). The plan restores --bind=0.0.0.0 as the single-node
default and introduces an explicit --advertise flag for off-host dial
targets; the reverted approach (auto-detect a specific IP at init,
hardcode 0.0.0.0 in the template, guard against loopback in
wireLBAgentConfig) becomes redundant once that lands.
Reverts:
- bb0ad3a fix: bind awsgw and predastore on 0.0.0.0 in spinifex.toml template
- f20a47b fix: dev-install scripts should let admin init auto-detect --bind
- 49b0b4e test: refresh wire lb loopback-bind comment for siv-7
- b88dfdf fix: auto-detect primary IP for admin init --bind default
Also drops the loopback guard from siv-6 (74b6e2d) wireLBAgentConfig
fallback and its regression test — subsumed by the GatewayURL
precedence rework in mulga-siv-8.5 (br-mgmt → AdvertiseIP → error,
no silent empty-string fallthrough). The br-mgmt OVS provisioning
from 74b6e2d is retained.
Plan: docs/development/bugs/spx-admin-init-bind.md
* feat: admin.DialTarget + AdvertiseHost helpers (mulga-siv-8.2)
Introduce the two small address-resolution helpers the listen-vs-
advertise split needs, with full unit coverage. No callers yet —
dial-site migration lands in mulga-siv-8.5.
- DialTarget(listenAddr): rewrites wildcard listen addresses
(0.0.0.0:N, [::]:N, :N) to their loopback equivalents so in-process
clients dial a target the daemon's cert already has in its SANs.
Specific IPs, loopback, hostnames, and malformed input pass through.
- AdvertiseHost(listenAddr, advertiseIP): picks the host off-host
clients should dial. Wildcard listen → advertiseIP; specific host →
that host. Port is dropped so callers append the protocol-appropriate
port.
Plan: docs/development/bugs/spx-admin-init-bind.md §Proposed Changes/1
* feat: plumb AdvertiseIP through config/formation (mulga-siv-8.3)
Pure data-model change. Add AdvertiseIP to:
- admin.ConfigSettings (local node, populated by init).
- config.Config (per-node; mapstructure "advertise").
- formation.NodeInfo (json "advertise_ip,omitempty") so the join handshake
carries it between peers.
buildRemoteNodes now prefers n.AdvertiseIP and falls back to n.BindIP so
joined nodes from older clusters / pre-siv-8 joiners keep working.
No behaviour change yet — templates, CLI flag, and dial-site migration
land in siv-8.4 and siv-8.5.
* feat: --advertise flag + resolveAdvertiseIP + templates (mulga-siv-8.4)
Introduce the listen-vs-advertise split at the CLI boundary.
admin init/join:
- --bind default for init is 0.0.0.0 (was 127.0.0.1 under siv-7 revert).
- New --advertise <IP> flag on both init and join; optional, auto-detected
from DetectNetwork().WAN.IP when --bind is wildcard or loopback.
- resolveAdvertiseIP(bindIP, advertiseFlag, detected) implements
precedence: flag > specific bindIP > WAN auto-detect > 127.0.0.1 +
warning.
- Join resolves advertise before building the JoinRequest so peers record
a reachable dial target (not 0.0.0.0).
- isMultiNode: trigger on --nodes >= 2 regardless of bind literal; operator
can now run "init --nodes 3" without typing a specific --bind.
- Init success message prints bind / advertise / loopback three-way split.
Templates:
- spinifex.toml: [nodes.X] gains advertise = "{{.AdvertiseIP}}" rendered
only when AdvertiseIP is set.
- predastore-multinode.toml: iam.nats_url host wrapped in the same
{{if eq .BindIP "0.0.0.0"}}localhost{{...}}{{end}} shim that
predastore.toml already uses, so co-resident predastore dials its local
NATS via loopback instead of 0.0.0.0.
Tests cover the resolveAdvertiseIP matrix, the template advertise field
(present + omitted), and the predastore nats_url loopback shim.
Dial-site migration and GatewayURL rework land in siv-8.5.
* feat: dial-site migration + GatewayURL AdvertiseIP fallback (mulga-siv-8.5)
Switch every in-process dial site to admin.DialTarget so the wildcard
listen address (0.0.0.0) is rewritten to loopback before Dial(): daemon
→ NATS and → predastore (boot, reconnect, status probe, S3 store, service
manifest write), awsgw → NATS. The TLS cert already SANs 127.0.0.1, so
loopback-dial a wildcard-listen service is always valid; the old
0.0.0.0 literal was tripping TLS SAN verification.
Rework wireLBAgentConfig GatewayURL precedence (spinifex/daemon/daemon.go):
1. AWSGW on specific WAN IP + br-mgmt present → WAN IP (unchanged)
2. br-mgmt present, AWSGW on 0.0.0.0 → br-mgmt IP (unchanged)
3. d.config.AdvertiseIP (single-node default install) → AdvertiseIP (NEW)
4. DevNetworking shim → 10.0.2.2 (unchanged)
5. AWSGW on specific IP, no bridge → that IP (unchanged)
6. Else → log error, skip assignment
Kills the pre-siv-8 silent empty-URL failure mode that made
CreateLoadBalancer fail with 'missing system credentials: gatewayURL='
on every fresh single-node install. Supersedes siv-6's loopback guard.
Extend SetupAWSCredentials with a wanIP parameter (reserved for a
future --operator-endpoint flag) and thread AdvertiseIP through
finalizeNodeSetup's three call sites (single-node init, multi-node
init, join). Print 'Bind / Advertise / Loopback' on multi-node init
and join completion to match the single-node summary.
Plan: docs/development/bugs/spx-admin-init-bind.md §2, §3
Reset now targets /etc/spinifex, /var/lib/spinifex, /var/log/spinifex,
/run/spinifex (the privilege-separated layout installed by setup.sh) and
drives re-install from a source build via dev-install.sh instead of the
legacy in-tree $HOME/spinifex + start-dev.sh flow.
Capture region, AZ, external_mode, pool range, gateway, and prefix from
the existing spinifex.toml before the wipe so the reset restores the
current topology rather than applying defaults. Fresh boxes fall back to
ap-southeast-2 and a pool derived from the WAN subnet.
Drop the macvlan branch entirely — bridge-only from here on. Operators
on single-NIC hosts must run reset from the console (documented in the
script header).
dev-install.sh gains DEV_INSTALL_SKIP_INIT so reset can own the post-
setup.sh steps (setup-ovn, spx admin init with preserved args, CA
trust, service start, LB image import). Also honors SPINIFEX_REGION /
SPINIFEX_AZ for non-reset callers, and scopes systemctl reset-failed
to spinifex-* so unrelated failed units aren't silently cleared.
Closes mulga-983.
Replace fragile image-name substring match (-lb-/-alb-) with a
DescribeImages tag filter on spinifex:managed-by=elbv2. Remove the
silent fallback that picks the first image in the store when no LB
image exists — CreateLoadBalancer now returns ServerInternal with a
remediation hint instead of persisting a record in StateFailed.
- daemon: tag filter + error return from the resolver closure
- service_impl: resolver signature is func() (string, error); caches
only successful results so the next call retries after an error
- CreateLoadBalancer gate now requires launcher + networking; AMI is
resolved inside the gate and failures short-circuit before persist
- admin images import: add --name+--file combo (catalog metadata with
a local file source) and a --tag key=value flag for explicit tagging
of file-only imports
- build-system-image.sh + lb.conf: propagate SYSTEM_TAG via --tag so
locally built system AMIs get the right tag even when the catalog
is bypassed
Closes mulga-969
chmod 0770 without -R only affected the top directory; pre-existing files
(e.g. images imported while owned by another user at mode 0600) stayed
unreadable to the spinifex group, breaking image import on upgrade paths.