Phase 11 in run-multinode-e2e.sh:
- Create VPC with public + private subnets + IGW
- Launch bastion in public subnet, verify SSH
- Create spread placement group, launch 3 VMs in private subnet
- Validate spread distribution via spx get vms (3 nodes)
- Verify no internet pre-NAT (ping 8.8.8.8 fails from all 3)
- Create NAT GW + EIP + route, poll for OVN SNAT rule
- Verify internet via NAT GW from all 3 nodes (different physical hosts)
- Full cleanup: NAT GW, instances, placement group, VPC resources
Sends anonymous telemetry to install.mulgadc.com/install during
spx admin init and join. Reports machine_id (/etc/machine-id),
region, az, node count, version, and arch. Fire-and-forget with
5-second timeout — never blocks the user.
Opt out with --no-telemetry flag or SPX_NO_TELEMETRY=1 env var.
In single-node mode, cert E2E discovered all host IPs (WAN, mgmt, VPC)
and tried openssl s_client on each. But awsgw only binds to the
configured host IP, not all interfaces. Management (10.11.x) and VPC
(10.x) IPs have no listener on port 9999, causing false failures.
Split NODE_IPS (all IPs for SAN validation) from SERVICE_IPS (IPs
where awsgw listens) parsed from spinifex.toml. Connection-based
tests (3, 4c, 5, 8) now use SERVICE_IPS.
The NAT GW E2E tests used 2-3 second sleeps before verifying SNAT
rule creation, outbound connectivity, and rule removal. This caused
flaky CI failures when OVN took longer to propagate flows to the
datapath (varies by host load and OVN version).
Replace with retry loops:
- SNAT rule check: poll OVN NB every 1s for up to 30s
- Outbound ping: retry up to 10 attempts with 5s backoff (~50s max)
- SNAT removal: poll up to 15 attempts with 2s backoff (~30s max)
Also dump OVN routes alongside NAT rules on failure for debugging.
Auto-discover all node IPs (WAN, mgmt, VPC) and hostname for server
cert SANs — fixes TLS failures when accessing Spinifex via non-localhost
IPs. Adds CA download endpoint (/api/ca.pem) with install instructions
on the login page. Injects CA cert into guest VM cloud-init so EC2
instances trust Spinifex services without --insecure. Adds 'spx admin
cert renew' command for cert regeneration after IP changes.
Includes certificate validation E2E test suite (run-cert-e2e.sh) with
system trust store, SAN, and in-guest TLS verification across single,
pseudo multi-node, and real multi-node modes.
Closes: mulga-777, mulga-778, mulga-779, mulga-780, mulga-781
Plan: docs/development/feature/cert-manager.md
Previously hardcoded CHASSIS_ID="chassis-node1" which could mismatch
the OVS system-id from prior setup-ovn.sh runs, creating stale chassis
entries in the SBDB. Now defers to setup-ovn.sh's auto-detect
(chassis-$(hostname -s)) so the name is always consistent.
Two stacked bugs prevented SSH to VPC instances:
1. The default route (0.0.0.0/0) was added without OutputPort. For
DHCP-sourced pools the gateway router port uses link-local addressing
(169.254.0.1/30) so OVN northd cannot resolve the nexthop (e.g.
192.168.1.1) to an output port — it silently drops the route from
the southbound DB.
2. discoverChassis returned all chassis from the SBDB including stale
entries from previous OVN setups on the same host. When a stale
chassis got highest gateway priority, the chassisredirect port
stayed unbound (up: false), so no ARP/NAT traffic was processed.
Fix: add OutputPort to static routes in both handleIGWAttach and
reconcileIGW, and filter stale chassis by cross-referencing the local
OVS system-id with SBDB hostnames.
Root cause: when terminating instances, the vpc.delete-nat event was
published with an empty logicalIP. vpcd's DeleteNAT looked for a
dnat_and_snat rule with logicalIP="" — found nothing — and the real
rule was left as a stale entry in OVN.
When the IPAM later recycled that public IP for an EIP/NAT Gateway,
OVN had conflicting rules: stale dnat_and_snat AND new snat, both
using the same external IP.
Fix: extract PrivateIpAddress from instance.Instance before publishing
vpc.delete-nat, in both running and stopped termination paths.
Also adds 14 unit tests for NAT Gateway service.
E2E: associate subnet with route table BEFORE adding the NAT GW route.
CreateRoute publishes SNAT events for associated subnets — if the
association doesn't exist yet, no SNAT rule is created in OVN.
Validated locally: bastion SSH hop works, ping 8.8.8.8 passes with
NAT GW, fails without. All 5 steps confirmed.
reset-dev-env.sh: trust Spinifex CA cert before starting services,
fixing TLS cert verify failures on fresh resets.
The bastion SSH hop failed because the private instance's cloud-init
hadn't completed (SSH daemon not ready). The instance was "running"
from the hypervisor perspective but cloud-init takes ~30-40s.
- Replace 2-attempt retry with 30-attempt poll (5s intervals, 150s max)
- Hard failure with OVN debug output instead of silent skip
- Matches how wait_for_ssh works for public instances