The Proxmox disk wearout alert read "SSD has less than 10% life remaining (7% wearout)". The number is percent life remaining, so "7% wearout" reads as 7% worn and contradicts the first clause, and the Alerts overview shows that text verbatim. It now reads "SSD life remaining is 7%", the wording host-agent SMART wearout alerts already use. The threshold stays in the alert's Threshold field, which the card and notifications show beside the message; spelling it into the sentence as "below 10%" would be false at exactly 10%, which alerts. CheckDiskHealth also logged a failed disk at error and a worn disk at warn on every evaluation, not when the alert opened. The physical disk poll runs every 5 minutes by default, so one failed disk logged an error 288 times a day for as long as it stayed failed, and mock mode repeated it on every alert tick. Both now log at error or warn only on the evaluation that opens the alert and at debug afterwards. The new log test captures through a hook installed in TestMain: assigning log.Logger inside a test would race with managers that earlier tests leave running. The alerts contract also said wearout recovery needs readings of at least 10%; a 10% reading still matches, so recovery needs readings above it.