mirror of
https://github.com/rcourtman/Pulse.git
synced 2026-10-24 04:33:17 +00:00
b7049ff778
**Stacked on #2675** (TrueNAS disk temperature alerts by disk type). Merge that first; this branch contains its commit. ## Problem A Proxmox physical disk that only the node's own sensors report never raised a temperature alert: - `CheckDiskHealth` judges health and wearout only; - unified evaluation types TrueNAS physical disks, not PVE ones. So Physical Disks could read a disk **Running Hot** under the per-type thresholds while alerts stayed silent. Whether a disk alerted depended on whether a Pulse agent ran on the node: agent-covered disks alert through `CheckHost` at the same thresholds. #1347 shows users look for disk temperature thresholds in the Proxmox tabs. ## Change - **`CheckProxmoxDiskTemperature`** (`internal/alerts/proxmox_disk_temperature.go`) raises a `diskTemperature` metric alert under the disk's existing PVE alert reference. It is judged by the disk temperature policy: the disk type's `DiskTempByType` entry under the agent Disk Temp default, which switches it off for every type. The alert carries the disk's serial, WWN and `diskType`, like the health and wearout alerts. - **One alert per disk.** `mergeHostAgentSMARTIntoDisks` marks a disk that a still-reporting linked agent lists in its SMART report (`AgentSMARTReported`, internal, never serialized). That disk is the agent's: `CheckHost` alerts on it, and an open PVE alert closes with `moved_to_agent`. A lapsed agent owns nothing, so the node's own current readings keep alerting while its agent is silent. - **Holds and clears.** Only a reading collected this poll is judged (`diskinventory.TemperatureCollected`), so a retained value holds the alert. An excluded device, or a switched-off policy, closes it. - **Stability.** A new `proxmox-disk` alert delay defaults to 5s, so warnings wait the same 300s noisy-gauge window as agent and TrueNAS disk temperatures. Critical readings bypass it. - **Config save.** `reevaluateActiveAlertsLocked` re-judges the alert per disk type. Without this it would fall through to guest thresholds, which have no disk temperature, and resolve on every save. An alert without a recorded type uses the lowest per-type trigger. - **History.** `ProxmoxPhysicalDiskAlertIdentifiers` lists the new `<ref>::metric-threshold:diskTemperature` identifier, so resource history owns its rows by recorded hardware identity, as #2646 does for health and wearout. - **Copy.** The Agents "Disk temperature by type" card says it covers agent, TrueNAS and Proxmox disks. ## Evidence Private mock stack (8 PVE nodes) with a local-only overlay pinning PVE disk readings: | Disk | Physical Disks | Alert | |---|---|---| | pve1 NVMe 63°C | Healthy | none | | pve2 SATA 56°C | Running Hot | warning, trigger 55, after the 300s window | | pve3 NVMe 72°C | Running Hot | warning, trigger 70, after the 300s window | | pve3 SAS 63°C | Healthy | none | | pve3 SATA 66°C | Running Hot | critical at once | The alert card reads: "Samsung 870 EVO 1TB (/dev/nvme2) · Temperature · Temperature 66°C, above the 55°C alert level · Clears once it drops to 50°C or lower and stays there for 5 minutes." ## Tests - `internal/alerts/alerts_test.go`: - the policy (per type, raised trigger); - ownership with `moved_to_agent`, the hold without a reading, exclusion, the off switch; - the stability window; - re-judging on save, including the lowest-trigger hold; - history identifiers. - `internal/monitoring/physical_disk_roundtrip_test.go`: the marker for reporting agents only (not a lapsed one), the SMART fallback path, and that `checkPhysicalDiskAlerts` passes collected readings, ownership and exclusion. - `internal/unifiedresources/store_test.go`: a temperature alert row is owned by its disk and still found by a read by its reference. - `internal/models/deepcopy_test.go`: the marker survives cloning and stays out of JSON. - `ThresholdsTable.test.tsx`: the card copy. - Ten wiring points were mutation-checked (marker, lease condition, collected reading, ownership, exclusion, re-judge branch, lowest trigger, resolution, history identifier); each removal fails a test. ## Second opinion - Fixed: an offline agent's retained SMART rows kept ownership, so neither side alerted while the agent was silent. Ownership now needs a reporting lease. - Kept, documented in `alerts.md`: on the first poll after an agent is newly linked to a disk with an open PVE alert, both alerts can be open until the next disk poll. This is the same window as the node-to-agent usage alert handover. ## Not in this PR - Like the health and wearout alerts, a disk that leaves the inventory keeps its temperature alert until the 24-hour stale sweep. - Per-host Disk Temp overrides do not reach PVE-only disks, which have no agent host.