rcourtman b7049ff778 Raise Proxmox disk temperature alerts under the per-type policy (#2680)
**Stacked on #2675** (TrueNAS disk temperature alerts by disk type).
Merge that first; this branch contains its commit.

## Problem

A Proxmox physical disk that only the node's own sensors report never
raised a temperature alert:

- `CheckDiskHealth` judges health and wearout only;
- unified evaluation types TrueNAS physical disks, not PVE ones.

So Physical Disks could read a disk **Running Hot** under the per-type
thresholds while alerts stayed silent. Whether a disk alerted depended
on whether a Pulse agent ran on the node: agent-covered disks alert
through `CheckHost` at the same thresholds. #1347 shows users look for
disk temperature thresholds in the Proxmox tabs.

## Change

- **`CheckProxmoxDiskTemperature`**
(`internal/alerts/proxmox_disk_temperature.go`) raises a
`diskTemperature` metric alert under the disk's existing PVE alert
reference. It is judged by the disk temperature policy: the disk type's
`DiskTempByType` entry under the agent Disk Temp default, which switches
it off for every type. The alert carries the disk's serial, WWN and
`diskType`, like the health and wearout alerts.
- **One alert per disk.** `mergeHostAgentSMARTIntoDisks` marks a disk
that a still-reporting linked agent lists in its SMART report
(`AgentSMARTReported`, internal, never serialized). That disk is the
agent's: `CheckHost` alerts on it, and an open PVE alert closes with
`moved_to_agent`. A lapsed agent owns nothing, so the node's own current
readings keep alerting while its agent is silent.
- **Holds and clears.** Only a reading collected this poll is judged
(`diskinventory.TemperatureCollected`), so a retained value holds the
alert. An excluded device, or a switched-off policy, closes it.
- **Stability.** A new `proxmox-disk` alert delay defaults to 5s, so
warnings wait the same 300s noisy-gauge window as agent and TrueNAS disk
temperatures. Critical readings bypass it.
- **Config save.** `reevaluateActiveAlertsLocked` re-judges the alert
per disk type. Without this it would fall through to guest thresholds,
which have no disk temperature, and resolve on every save. An alert
without a recorded type uses the lowest per-type trigger.
- **History.** `ProxmoxPhysicalDiskAlertIdentifiers` lists the new
`<ref>::metric-threshold:diskTemperature` identifier, so resource
history owns its rows by recorded hardware identity, as #2646 does for
health and wearout.
- **Copy.** The Agents "Disk temperature by type" card says it covers
agent, TrueNAS and Proxmox disks.

## Evidence

Private mock stack (8 PVE nodes) with a local-only overlay pinning PVE
disk readings:

| Disk | Physical Disks | Alert |
|---|---|---|
| pve1 NVMe 63°C | Healthy | none |
| pve2 SATA 56°C | Running Hot | warning, trigger 55, after the 300s
window |
| pve3 NVMe 72°C | Running Hot | warning, trigger 70, after the 300s
window |
| pve3 SAS 63°C | Healthy | none |
| pve3 SATA 66°C | Running Hot | critical at once |

The alert card reads: "Samsung 870 EVO 1TB (/dev/nvme2) · Temperature ·
Temperature 66°C, above the 55°C alert level · Clears once it drops to
50°C or lower and stays there for 5 minutes."

## Tests

- `internal/alerts/alerts_test.go`:
  - the policy (per type, raised trigger);
- ownership with `moved_to_agent`, the hold without a reading,
exclusion, the off switch;
  - the stability window;
  - re-judging on save, including the lowest-trigger hold;
  - history identifiers.
- `internal/monitoring/physical_disk_roundtrip_test.go`: the marker for
reporting agents only (not a lapsed one), the SMART fallback path, and
that `checkPhysicalDiskAlerts` passes collected readings, ownership and
exclusion.
- `internal/unifiedresources/store_test.go`: a temperature alert row is
owned by its disk and still found by a read by its reference.
- `internal/models/deepcopy_test.go`: the marker survives cloning and
stays out of JSON.
- `ThresholdsTable.test.tsx`: the card copy.
- Ten wiring points were mutation-checked (marker, lease condition,
collected reading, ownership, exclusion, re-judge branch, lowest
trigger, resolution, history identifier); each removal fails a test.

## Second opinion

- Fixed: an offline agent's retained SMART rows kept ownership, so
neither side alerted while the agent was silent. Ownership now needs a
reporting lease.
- Kept, documented in `alerts.md`: on the first poll after an agent is
newly linked to a disk with an open PVE alert, both alerts can be open
until the next disk poll. This is the same window as the node-to-agent
usage alert handover.

## Not in this PR

- Like the health and wearout alerts, a disk that leaves the inventory
keeps its temperature alert until the 24-hour stale sweep.
- Per-host Disk Temp overrides do not reach PVE-only disks, which have
no agent host.
2026-10-07 21:59:39 +01:00
..
2026-10-05 21:53:41 +01:00
…
2026-10-05 21:53:41 +01:00
2026-10-05 21:53:41 +01:00

Pulse documentation

Start here for installation, platform setup, security, operations, and Pulse Intelligence. Commands, configuration keys, image names, API fields, and product identifiers remain untranslated in localized guides.

Start here

  • Install Pulse — signed Proxmox/Linux installation, Docker, Docker Compose, Kubernetes, and first-run setup.
  • Production deployment and security — least-privilege Proxmox setup, root-agent boundaries, discovery, supply-chain verification, plan limits, scale evidence, and a rollout checklist.
  • Upgrade from Pulse v5 — migration prerequisites, rollback, agent continuity, and post-upgrade checks.
  • Releases and update channels: choosing Stable or Preview, beta and RC expectations, and how releases are tested and promoted.
  • Configure Pulse — authentication, notifications, discovery, retention, and system settings.
  • Deployment models — data locations, lifecycle, and differences between supported deployment paths.
  • Troubleshooting and FAQ — common failures, diagnostics, and operator questions.

Localized getting started guides: Deutsch · Español

Platforms and agents

VMware vSphere support is early access. Current builds expose dedicated vSphere inventory and recovery context, but operators should validate the integration against their own vCenter before production use.

Monitoring and operations

Pulse Intelligence

Patrol watch-only analysis is available on Community with a local model or the operator's own provider. Investigation and governed fixes require the relevant Pulse Pro capabilities.

Security, privacy, and access

Plans and managed access

Pulse Cloud is not generally available. Ordinary self-hosted Pulse remains the primary installation path; MSP and Enterprise access are explicit commercial paths rather than defaults in self-hosted setup.

Development and reference

Detailed design notes and dated migration specifications may remain in this directory for maintainers, but they are not operator setup guides unless they are linked from the sections above.

Previous versions and migrations

Found a bug? Use the issue forms. For setup questions, use GitHub Discussions.