Move TrueNAS re-judge tests clear of the cleanup tests
#2672 added its node cleanup tests right after TestCleanupAlertsForNodes, where this branch had added its TrueNAS disk temperature re-judge tests, so the branch no longer merged with main. Place the TrueNAS tests just before TestCleanupAlertsForNodes instead; no test changes.
This commit is contained in:
@@ -12300,6 +12300,65 @@ func TestCheckEscalations(t *testing.T) {
|
||||
})
|
||||
}
|
||||
|
||||
// A config save re-judges open TrueNAS disk temperature alerts against the
|
||||
// threshold the next evaluation applies to each disk's type.
|
||||
func TestTrueNASDiskTemperatureAlertsReevaluatePerDiskType(t *testing.T) {
|
||||
m := newTestManager(t)
|
||||
cfg := unifiedEvalBaseConfig()
|
||||
cfg.TrueNASDiskDefaults = ThresholdConfig{}
|
||||
configureUnifiedEvalManager(t, m, cfg)
|
||||
|
||||
nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 72)
|
||||
sata := trueNASTemperatureDisk("sda", "sata", 57)
|
||||
checkTrueNASTemperatureDisk(t, m, nvme)
|
||||
checkTrueNASTemperatureDisk(t, m, sata)
|
||||
for _, disk := range []unifiedresources.Resource{nvme, sata} {
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, disk); !firing {
|
||||
t.Fatalf("%s did not fire before the save: %v", disk.ID, alertKeys(m))
|
||||
}
|
||||
}
|
||||
|
||||
// Raising only the NVMe trigger resolves the NVMe alert and leaves the
|
||||
// SATA alert, still over its own trigger, open.
|
||||
m.mu.Lock()
|
||||
m.config.DiskTempByType["nvme"] = HysteresisThreshold{Trigger: 75, Clear: 70}
|
||||
m.reevaluateActiveAlertsLocked()
|
||||
m.mu.Unlock()
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); firing {
|
||||
t.Fatalf("NVMe alert at 72C stayed open under a 75C NVMe trigger")
|
||||
}
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, sata); !firing {
|
||||
t.Fatalf("SATA alert at 57C resolved under its unchanged 55C trigger")
|
||||
}
|
||||
}
|
||||
|
||||
// An alert raised before it recorded its disk type is held to the lowest
|
||||
// per-type trigger, so a save never resolves an alert the next evaluation
|
||||
// raises again.
|
||||
func TestTrueNASDiskTemperatureAlertWithoutDiskTypeHeldAtLowestTrigger(t *testing.T) {
|
||||
m := newTestManager(t)
|
||||
cfg := unifiedEvalBaseConfig()
|
||||
cfg.TrueNASDiskDefaults = ThresholdConfig{}
|
||||
cfg.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 70, Clear: 65}
|
||||
cfg.DiskTempByType = map[string]HysteresisThreshold{"nvme": {Trigger: 60, Clear: 55}}
|
||||
configureUnifiedEvalManager(t, m, cfg)
|
||||
|
||||
nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 66)
|
||||
checkTrueNASTemperatureDisk(t, m, nvme)
|
||||
alert, firing := trueNASDiskTemperatureAlert(t, m, nvme)
|
||||
if !firing {
|
||||
t.Fatalf("NVMe at 66C did not fire under a 60C NVMe trigger: %v", alertKeys(m))
|
||||
}
|
||||
|
||||
m.mu.Lock()
|
||||
delete(alert.Metadata, "diskType")
|
||||
m.reevaluateActiveAlertsLocked()
|
||||
m.mu.Unlock()
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); !firing {
|
||||
t.Fatalf("an alert without a disk type was resolved by the 70C agent default although its NVMe trigger is 60C")
|
||||
}
|
||||
}
|
||||
|
||||
func TestCleanupAlertsForNodes(t *testing.T) {
|
||||
// t.Parallel()
|
||||
|
||||
@@ -12628,65 +12687,6 @@ func TestCleanupAlertsForNodes(t *testing.T) {
|
||||
})
|
||||
}
|
||||
|
||||
// A config save re-judges open TrueNAS disk temperature alerts against the
|
||||
// threshold the next evaluation applies to each disk's type.
|
||||
func TestTrueNASDiskTemperatureAlertsReevaluatePerDiskType(t *testing.T) {
|
||||
m := newTestManager(t)
|
||||
cfg := unifiedEvalBaseConfig()
|
||||
cfg.TrueNASDiskDefaults = ThresholdConfig{}
|
||||
configureUnifiedEvalManager(t, m, cfg)
|
||||
|
||||
nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 72)
|
||||
sata := trueNASTemperatureDisk("sda", "sata", 57)
|
||||
checkTrueNASTemperatureDisk(t, m, nvme)
|
||||
checkTrueNASTemperatureDisk(t, m, sata)
|
||||
for _, disk := range []unifiedresources.Resource{nvme, sata} {
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, disk); !firing {
|
||||
t.Fatalf("%s did not fire before the save: %v", disk.ID, alertKeys(m))
|
||||
}
|
||||
}
|
||||
|
||||
// Raising only the NVMe trigger resolves the NVMe alert and leaves the
|
||||
// SATA alert, still over its own trigger, open.
|
||||
m.mu.Lock()
|
||||
m.config.DiskTempByType["nvme"] = HysteresisThreshold{Trigger: 75, Clear: 70}
|
||||
m.reevaluateActiveAlertsLocked()
|
||||
m.mu.Unlock()
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); firing {
|
||||
t.Fatalf("NVMe alert at 72C stayed open under a 75C NVMe trigger")
|
||||
}
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, sata); !firing {
|
||||
t.Fatalf("SATA alert at 57C resolved under its unchanged 55C trigger")
|
||||
}
|
||||
}
|
||||
|
||||
// An alert raised before it recorded its disk type is held to the lowest
|
||||
// per-type trigger, so a save never resolves an alert the next evaluation
|
||||
// raises again.
|
||||
func TestTrueNASDiskTemperatureAlertWithoutDiskTypeHeldAtLowestTrigger(t *testing.T) {
|
||||
m := newTestManager(t)
|
||||
cfg := unifiedEvalBaseConfig()
|
||||
cfg.TrueNASDiskDefaults = ThresholdConfig{}
|
||||
cfg.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 70, Clear: 65}
|
||||
cfg.DiskTempByType = map[string]HysteresisThreshold{"nvme": {Trigger: 60, Clear: 55}}
|
||||
configureUnifiedEvalManager(t, m, cfg)
|
||||
|
||||
nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 66)
|
||||
checkTrueNASTemperatureDisk(t, m, nvme)
|
||||
alert, firing := trueNASDiskTemperatureAlert(t, m, nvme)
|
||||
if !firing {
|
||||
t.Fatalf("NVMe at 66C did not fire under a 60C NVMe trigger: %v", alertKeys(m))
|
||||
}
|
||||
|
||||
m.mu.Lock()
|
||||
delete(alert.Metadata, "diskType")
|
||||
m.reevaluateActiveAlertsLocked()
|
||||
m.mu.Unlock()
|
||||
if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); !firing {
|
||||
t.Fatalf("an alert without a disk type was resolved by the 70C agent default although its NVMe trigger is 60C")
|
||||
}
|
||||
}
|
||||
|
||||
func TestCheckZFSPoolHealth(t *testing.T) {
|
||||
// t.Parallel()
|
||||
poolStateAlertID := buildCanonicalStateID("local-zfs/zfs-pool:rpool", "local-zfs/zfs-pool:rpool-state")
|
||||
|
||||
Reference in New Issue