# Hetzner Robot node setup (dual NVMe)
|
||
|
||
Goal: Ubuntu on **one** NVMe with `/dev/kvm`, and a **second raw NVMe** for the
|
||
`kfd` (kata-firecracker-devmapper) LVM thin-pool.
|
||
|
||
> The older PDF next to this file
|
||
> ([`k7_hetzner_node_setup.pdf`](k7_hetzner_node_setup.pdf)) assumed you could
|
||
> order a **third** empty NVMe and leave it unformatted. Hetzner often ships
|
||
> dual-NVMe boxes now **without** an add-on disk option, and the default
|
||
> `installimage` layout puts the OS on **software RAID across both drives**.
|
||
> Use this guide instead.
|
||
|
||
> **Automated alternative:** if you have Hetzner Robot API credentials
|
||
> (`ROBOT_USER`/`ROBOT_PASS`) and your SSH key registered in Robot,
|
||
> `TWO_DISK=1 HOSTNAME_VALUE=<name> utils/reset_robot_node.sh <server-number> <ip>`
|
||
> automates steps 2–3 end-to-end: rescue boot, wipe of **both** NVMes,
|
||
> single-disk installimage (`SWRAID 0`), reboot into Ubuntu. Because it
|
||
> pre-wipes the spare disk in rescue, step 3 below can be skipped. See
|
||
> `editor-config/skills/hetzner-k7-node-reset/SKILL.md` for details.
|
||
|
||
## 1. Pick a dedicated (Robot) server
|
||
|
||
- Must expose hardware virtualization: `ls /dev/kvm` after install.
|
||
- Robot dedicated only (not Cloud CX/CPX VPS).
|
||
- Prefer Intel/AMD x86 with **2× NVMe** included (e.g. AX/EX matrix).
|
||
- You do **not** need a third drive slot if the box already has two NVMes.
|
||
|
||
## 2. Rescue → installimage on a single disk
|
||
|
||
1. In [Robot](https://robot.hetzner.com): **Rescue** → Linux 64-bit → activate → reboot.
|
||
2. SSH into rescue and check disks:
|
||
|
||
```bash
|
||
lsblk -d -o NAME,SIZE,MODEL,TRAN
|
||
```
|
||
|
||
3. Run `installimage`, pick Ubuntu 24.04 (Noble), then edit the config so only
|
||
**one** drive is used and software RAID is off:
|
||
|
||
```text
|
||
DRIVE1 /dev/nvme0n1
|
||
# DRIVE2 /dev/nvme1n1 # omit / keep commented — thin-pool disk
|
||
|
||
SWRAID 0
|
||
SWRAIDLEVEL 0
|
||
|
||
BOOTLOADER grub
|
||
HOSTNAME k7-node
|
||
|
||
PART /boot ext4 1024M
|
||
PART swap swap 8G
|
||
PART / ext4 all
|
||
|
||
IMAGE /root/images/Ubuntu-2404-noble-amd64-base.tar.gz
|
||
```
|
||
|
||
Adjust `DRIVE1` / image path to match what `installimage` shows. Save, quit,
|
||
confirm the wipe, wait for install, then `reboot`.
|
||
|
||
## 3. Wipe leftover RAID metadata on the spare disk
|
||
|
||
After first boot, the unused NVMe often still has old `md` / LVM signatures
|
||
from a previous RAID layout. Wipe it **before** `k7 install`:
|
||
|
||
```bash
|
||
lsblk -f
|
||
# example: spare is /dev/nvme1n1
|
||
sudo mdadm --stop --scan || true
|
||
sudo ./utils/wipe-disk.sh /dev/nvme1n1
|
||
lsblk -f # spare should show no FSTYPE / no RAID members
|
||
```
|
||
|
||
`wipe-disk.sh` is destructive — only point it at the spare disk.
|
||
|
||
## 4. Install k7 and point at the raw disk
|
||
|
||
```bash
|
||
sudo add-apt-repository ppa:katakate.org/k7
|
||
sudo apt update
|
||
sudo apt install k7
|
||
k7 -V # 0.4.0
|
||
|
||
# dual-NVMe box: let the playbook auto-detect the raw spare disk.
|
||
# Run from a checkout of this repo (or Katakate/k7) so k7-api:local can build.
|
||
sudo k7 install --backend kfd,kql,k7d,k7d-fc
|
||
```
|
||
|
||
`k7 install` provisions the LVM thin-pool on that disk for the `kfd` backend.
|
||
Other backends (`kql`, `k7d`) do not need this spare disk, but keeping one raw
|
||
NVMe lets you compare all backends on the same node.
|
||
|
||
Two-node (one server + one agent, no `--ha`) is the same idea: write an
|
||
inventory with `k7_backends=kfd,kql,k7d,k7d-fc` on both hosts, omit
|
||
`k7_devmapper_disk`, and run **one** `k7 install -i inventory.ini --k7d-version 0.7.0`
|
||
from the first master. See `src/k7/deploy/inventory.ini.example`.
|
||
|
||
> **Do NOT pin the disk on dual-NVMe boxes.** NVMe enumeration
|
||
> (`nvme0n1` vs `nvme1n1`) is **not stable across reboots**, so a hardcoded
|
||
> `--disk /dev/nvme1n1` (or `k7_devmapper_disk` in a multi-node inventory)
|
||
> can point at the OS disk after a reboot. The playbook auto-detects the
|
||
> empty non-root whole disk, which is enumeration-proof. Pin a device only
|
||
> when a node has several spare disks and you must pick a specific one.
|
||
> The same applies to multi-node installs — see the dual-NVMe note in
|
||
> `src/k7/deploy/inventory.ini.example`.
|
||
>
|
||
> Sizing: only the first `kata_thinpool_pv_size` (default 100G) of the spare
|
||
> disk is used for the kfd thin-pool, and the k7d volume pool defaults to a
|
||
> 32G sparse image (`k7d_disks_image_size`). Override both per node in the
|
||
> inventory — see "Disk pool sizing" in `docs/BACKENDS.md`.
|
||
|
||
## Checklist
|
||
|
||
- [ ] `ls /dev/kvm` exists
|
||
- [ ] OS root is on a single disk (`findmnt /` → `/dev/nvme0n1p…`, not `/dev/md…`)
|
||
- [ ] Spare disk has no filesystem (`lsblk -f` empty FSTYPE)
|
||
- [ ] `k7 install --backend kfd,kql,k7d,k7d-fc --k7d-version 0.7.0` succeeds (auto-detects the spare disk — do not pin `--disk` on dual-NVMe)
|
||
- [ ] `k7 create --backend kfd …` can start a sandbox
|