#!/bin/bash
|
|
|
|
# OVN Compute Node Setup for Spinifex VPC Networking
|
|
#
|
|
# This script bootstraps a compute node for OVN-based VPC networking:
|
|
# 1. Installs OVN/OVS packages (if not present)
|
|
# 2. Enables required services (openvswitch-switch, ovn-controller)
|
|
# 3. Creates br-int with secure fail-mode
|
|
# 4. Configures OVS external_ids for OVN chassis identity
|
|
# 5. Applies sysctl tuning for overlay networking
|
|
#
|
|
# Usage:
|
|
# ./scripts/setup-ovn.sh [options]
|
|
#
|
|
# Options:
|
|
# --management Also start OVN central services (NB DB, SB DB, ovn-northd)
|
|
# --external-bridge Create br-external for public subnet WAN uplink
|
|
# --external-iface WAN NIC to add to br-external (default: eth1)
|
|
# --dhcp Obtain gateway IP via DHCP on the external bridge interface
|
|
# --ovn-remote OVN SB DB address (default: tcp:127.0.0.1:6642)
|
|
# --encap-ip Geneve tunnel endpoint IP (default: auto-detect)
|
|
# --chassis-id OVN chassis identifier (default: hostname)
|
|
#
|
|
# Examples:
|
|
# # Single-node development (management + compute on same host):
|
|
# ./scripts/setup-ovn.sh --management
|
|
#
|
|
# # With external bridge (macvlan on WAN NIC — SSH-safe):
|
|
# ./scripts/setup-ovn.sh --management --external-bridge --external-iface=eth0
|
|
#
|
|
# # Compute node joining an existing cluster:
|
|
# ./scripts/setup-ovn.sh --ovn-remote=tcp:10.0.0.1:6642 --encap-ip=10.0.0.2
|
|
#
|
|
# # Multi-node dev cluster (node1 = management):
|
|
# Node 1: ./scripts/setup-ovn.sh --management --encap-ip=127.0.0.1
|
|
# Node 2: ./scripts/setup-ovn.sh --ovn-remote=tcp:127.0.0.1:6642 --encap-ip=127.0.0.2
|
|
# Node 3: ./scripts/setup-ovn.sh --ovn-remote=tcp:127.0.0.1:6642 --encap-ip=127.0.0.3
|
|
|
|
set -e
|
|
|
|
# Defaults
|
|
MANAGEMENT=false
|
|
EXTERNAL_BRIDGE=false
|
|
EXTERNAL_DHCP=false
|
|
EXTERNAL_IFACE="eth1"
|
|
OVN_REMOTE="tcp:127.0.0.1:6642"
|
|
ENCAP_IP=""
|
|
CHASSIS_ID=""
|
|
|
|
# Parse arguments
|
|
for arg in "$@"; do
|
|
case "$arg" in
|
|
--management) MANAGEMENT=true ;;
|
|
--external-bridge) EXTERNAL_BRIDGE=true ;;
|
|
--dhcp) EXTERNAL_DHCP=true ;;
|
|
--external-iface=*) EXTERNAL_IFACE="${arg#*=}" ;;
|
|
--ovn-remote=*) OVN_REMOTE="${arg#*=}" ;;
|
|
--encap-ip=*) ENCAP_IP="${arg#*=}" ;;
|
|
--chassis-id=*) CHASSIS_ID="${arg#*=}" ;;
|
|
--help|-h)
|
|
head -36 "$0" | tail -34
|
|
exit 0
|
|
;;
|
|
*)
|
|
echo "Unknown option: $arg"
|
|
exit 1
|
|
;;
|
|
esac
|
|
done
|
|
|
|
# Auto-detect encap IP if not specified
|
|
if [ -z "$ENCAP_IP" ]; then
|
|
ENCAP_IP=$(ip -4 route get 8.8.8.8 2>/dev/null | awk '/src/{print $7}' | head -1)
|
|
if [ -z "$ENCAP_IP" ]; then
|
|
ENCAP_IP="127.0.0.1"
|
|
fi
|
|
echo "Auto-detected encap IP: $ENCAP_IP"
|
|
fi
|
|
|
|
# Auto-detect chassis ID if not specified
|
|
if [ -z "$CHASSIS_ID" ]; then
|
|
CHASSIS_ID="chassis-$(hostname -s)"
|
|
echo "Auto-detected chassis ID: $CHASSIS_ID"
|
|
fi
|
|
|
|
echo "=== Spinifex OVN Compute Node Setup ==="
|
|
echo " Management node: $MANAGEMENT"
|
|
echo " External bridge: $EXTERNAL_BRIDGE"
|
|
if [ "$EXTERNAL_BRIDGE" = true ]; then
|
|
echo " External iface: $EXTERNAL_IFACE"
|
|
fi
|
|
echo " OVN Remote (SB): $OVN_REMOTE"
|
|
echo " Encap IP: $ENCAP_IP"
|
|
echo " Chassis ID: $CHASSIS_ID"
|
|
echo ""
|
|
|
|
# --- Step 1: Install packages ---
|
|
echo "Step 1: Checking OVN/OVS packages..."
|
|
|
|
install_packages() {
|
|
local missing=()
|
|
for pkg in openvswitch-switch ovn-host; do
|
|
if ! dpkg -s "$pkg" >/dev/null 2>&1; then
|
|
missing+=("$pkg")
|
|
fi
|
|
done
|
|
if [ "$MANAGEMENT" = true ]; then
|
|
if ! dpkg -s ovn-central >/dev/null 2>&1; then
|
|
missing+=("ovn-central")
|
|
fi
|
|
fi
|
|
|
|
if [ ${#missing[@]} -gt 0 ]; then
|
|
echo " Installing: ${missing[*]}"
|
|
sudo apt-get update -qq
|
|
sudo apt-get install -y -qq "${missing[@]}"
|
|
else
|
|
echo " All packages installed"
|
|
fi
|
|
}
|
|
|
|
install_packages
|
|
|
|
# --- Step 2: Enable services ---
|
|
echo ""
|
|
echo "Step 2: Enabling services..."
|
|
|
|
sudo systemctl enable openvswitch-switch
|
|
sudo systemctl start openvswitch-switch
|
|
echo " openvswitch-switch: started"
|
|
|
|
if [ "$MANAGEMENT" = true ]; then
|
|
sudo systemctl enable ovn-central
|
|
sudo systemctl start ovn-central
|
|
echo " ovn-central: started (NB DB + SB DB + ovn-northd)"
|
|
|
|
# Wait for OVN NB DB socket to become available
|
|
for i in $(seq 1 15); do
|
|
if sudo ovn-nbctl --timeout=2 get-connection >/dev/null 2>&1; then
|
|
break
|
|
fi
|
|
echo " Waiting for OVN NB DB... ($i/15)"
|
|
sleep 1
|
|
done
|
|
|
|
# Allow remote connections to NB and SB databases
|
|
sudo ovn-nbctl set-connection ptcp:6641
|
|
sudo ovn-sbctl set-connection ptcp:6642
|
|
echo " OVN NB DB listening on tcp:6641"
|
|
echo " OVN SB DB listening on tcp:6642"
|
|
fi
|
|
|
|
# --- Step 3: Create and configure br-int ---
|
|
echo ""
|
|
echo "Step 3: Configuring br-int..."
|
|
|
|
sudo ovs-vsctl --may-exist add-br br-int
|
|
sudo ovs-vsctl set Bridge br-int fail-mode=secure
|
|
sudo ovs-vsctl set Bridge br-int other-config:disable-in-band=true
|
|
sudo ip link set br-int up
|
|
echo " br-int: created, fail-mode=secure, up"
|
|
|
|
# --- Step 3b: Create br-external for WAN uplink (optional) ---
|
|
if [ "$EXTERNAL_BRIDGE" = true ]; then
|
|
echo ""
|
|
echo "Step 3b: Configuring br-external for public subnet WAN uplink..."
|
|
|
|
# Verify the WAN NIC exists
|
|
if ! ip link show "$EXTERNAL_IFACE" >/dev/null 2>&1; then
|
|
echo " ERROR: interface $EXTERNAL_IFACE does not exist"
|
|
echo " Available interfaces:"
|
|
ip -o link show | awk -F': ' '{print " " $2}'
|
|
exit 1
|
|
fi
|
|
|
|
# Create br-external
|
|
sudo ovs-vsctl --may-exist add-br br-external
|
|
sudo ip link set br-external up
|
|
|
|
# macvlan strategy: create a macvlan sub-interface in bridge mode off the
|
|
# WAN NIC. The host keeps its IP on the parent NIC — SSH-safe. OVN localnet
|
|
# traffic flows through the macvlan to the physical wire.
|
|
MACVLAN_NAME="spx-ext-${EXTERNAL_IFACE}"
|
|
|
|
if ip link show "$MACVLAN_NAME" >/dev/null 2>&1; then
|
|
echo " macvlan $MACVLAN_NAME already exists"
|
|
else
|
|
sudo ip link add "$MACVLAN_NAME" link "$EXTERNAL_IFACE" type macvlan mode bridge
|
|
echo " created macvlan: $MACVLAN_NAME (bridge mode) on $EXTERNAL_IFACE"
|
|
fi
|
|
|
|
sudo ip link set "$MACVLAN_NAME" up
|
|
sudo ovs-vsctl --may-exist add-port br-external "$MACVLAN_NAME"
|
|
echo " br-external: created with macvlan port $MACVLAN_NAME"
|
|
echo " NOTE: host keeps its IP on $EXTERNAL_IFACE (no migration)"
|
|
echo " QUIRK: host cannot reach VMs at their public IPs (macvlan isolation)"
|
|
|
|
# --- DHCP: obtain gateway IP for OVN SNAT ---
|
|
if [ "$EXTERNAL_DHCP" = true ]; then
|
|
echo ""
|
|
echo "Step 3c: Obtaining external gateway IP via DHCP..."
|
|
|
|
# DHCP on the macvlan interface (it has L2 access to the WAN)
|
|
DHCP_IFACE="spx-ext-${EXTERNAL_IFACE}"
|
|
|
|
# Run DHCP client to get a lease
|
|
if command -v dhcpcd >/dev/null 2>&1; then
|
|
sudo dhcpcd --waitip=4 --timeout 15 "$DHCP_IFACE" 2>/dev/null || true
|
|
elif command -v dhclient >/dev/null 2>&1; then
|
|
sudo dhclient -1 -timeout 15 "$DHCP_IFACE" 2>/dev/null || true
|
|
else
|
|
echo " WARNING: no DHCP client found (dhcpcd or dhclient)"
|
|
echo " Install dhcpcd-base or isc-dhcp-client, or set gateway_ip manually"
|
|
fi
|
|
|
|
# Read the obtained IP
|
|
DHCP_IP=$(ip -4 addr show dev "$DHCP_IFACE" 2>/dev/null | awk '/inet /{print $2}' | head -1 | cut -d/ -f1)
|
|
if [ -n "$DHCP_IP" ]; then
|
|
echo " DHCP obtained: $DHCP_IP on $DHCP_IFACE"
|
|
|
|
# Write the gateway IP to the spinifex config so vpcd can use it
|
|
CONFIG_DIR="${CONFIG_DIR:-$HOME/spinifex/config}"
|
|
CONFIG_FILE="$CONFIG_DIR/spinifex.toml"
|
|
if [ -f "$CONFIG_FILE" ]; then
|
|
# Update gateway_ip in the config
|
|
if grep -q "gateway_ip" "$CONFIG_FILE"; then
|
|
sed -i "s/gateway_ip.*/gateway_ip = \"$DHCP_IP\"/" "$CONFIG_FILE"
|
|
else
|
|
# Insert gateway_ip after the gateway line in the pool section
|
|
sed -i "/^gateway *=.*/a gateway_ip = \"$DHCP_IP\"" "$CONFIG_FILE"
|
|
fi
|
|
echo " Updated $CONFIG_FILE with gateway_ip = $DHCP_IP"
|
|
else
|
|
echo " WARNING: $CONFIG_FILE not found — set gateway_ip manually"
|
|
fi
|
|
else
|
|
echo " WARNING: DHCP failed to obtain IP on $DHCP_IFACE"
|
|
echo " VMs will not have external connectivity until gateway_ip is configured"
|
|
fi
|
|
fi
|
|
fi
|
|
|
|
# --- Step 4: Configure OVN external_ids ---
|
|
echo ""
|
|
echo "Step 4: Setting OVS external_ids for OVN..."
|
|
|
|
BRIDGE_MAPPINGS="external:br-external"
|
|
if [ "$EXTERNAL_BRIDGE" = true ]; then
|
|
sudo ovs-vsctl set Open_vSwitch . \
|
|
external_ids:system-id="$CHASSIS_ID" \
|
|
external_ids:ovn-remote="$OVN_REMOTE" \
|
|
external_ids:ovn-encap-ip="$ENCAP_IP" \
|
|
external_ids:ovn-encap-type="geneve" \
|
|
external_ids:ovn-bridge-mappings="$BRIDGE_MAPPINGS"
|
|
echo " ovn-bridge-mappings: $BRIDGE_MAPPINGS"
|
|
else
|
|
sudo ovs-vsctl set Open_vSwitch . \
|
|
external_ids:system-id="$CHASSIS_ID" \
|
|
external_ids:ovn-remote="$OVN_REMOTE" \
|
|
external_ids:ovn-encap-ip="$ENCAP_IP" \
|
|
external_ids:ovn-encap-type="geneve"
|
|
fi
|
|
|
|
echo " system-id: $CHASSIS_ID"
|
|
echo " ovn-remote: $OVN_REMOTE"
|
|
echo " ovn-encap-ip: $ENCAP_IP"
|
|
echo " ovn-encap-type: geneve"
|
|
|
|
# --- Step 5: Start ovn-controller ---
|
|
echo ""
|
|
echo "Step 5: Starting ovn-controller..."
|
|
|
|
sudo systemctl start ovn-controller
|
|
echo " ovn-controller: started"
|
|
|
|
# --- Step 6: Sysctl tuning ---
|
|
echo ""
|
|
echo "Step 6: Applying sysctl for overlay networking..."
|
|
|
|
sudo tee /etc/sysctl.d/99-spinifex-vpc.conf >/dev/null <<'SYSCTL'
|
|
# Spinifex VPC networking: enable IP forwarding and disable rp_filter
|
|
# for Geneve overlay traffic on OVS bridges.
|
|
net.ipv4.ip_forward=1
|
|
net.ipv4.conf.all.rp_filter=0
|
|
net.ipv4.conf.default.rp_filter=0
|
|
SYSCTL
|
|
sudo sysctl --system -q
|
|
echo " ip_forward=1, rp_filter=0"
|
|
|
|
# --- Step 6b: Ensure data NIC routing for Geneve tunnels ---
|
|
echo ""
|
|
echo "Step 6b: Configuring data NIC routing for Geneve tunnels..."
|
|
|
|
# When management and data NICs share the same subnet (e.g. both on 10.1.0.0/16),
|
|
# the kernel may route Geneve tunnel traffic through the management NIC with the
|
|
# wrong source IP. This causes remote OVS nodes to drop incoming tunnel packets
|
|
# because the source IP doesn't match the configured tunnel remote_ip.
|
|
# Fix: lower the route metric on the data NIC so it's preferred.
|
|
DATA_IFACE=$(ip -o -4 addr show | awk -v ip="$ENCAP_IP" '$0 ~ ip"/" {print $2}')
|
|
if [ -n "$DATA_IFACE" ]; then
|
|
SUBNET=$(ip -o -4 route show dev "$DATA_IFACE" proto kernel scope link | awk '{print $1}' | head -1)
|
|
if [ -n "$SUBNET" ]; then
|
|
sudo ip route replace "$SUBNET" dev "$DATA_IFACE" src "$ENCAP_IP" metric 50
|
|
echo " data route: $SUBNET via $DATA_IFACE src $ENCAP_IP (metric 50)"
|
|
else
|
|
echo " skipped: no kernel route found for $DATA_IFACE"
|
|
fi
|
|
else
|
|
echo " skipped: could not find interface for $ENCAP_IP"
|
|
fi
|
|
|
|
# --- Step 7: Verify Geneve kernel support ---
|
|
echo ""
|
|
echo "Step 7: Verifying Geneve kernel module..."
|
|
|
|
if sudo modprobe geneve 2>/dev/null; then
|
|
echo " geneve module: loaded"
|
|
else
|
|
echo " WARNING: geneve module not available (tunnels may not work)"
|
|
fi
|
|
|
|
# --- Step 8: Grant non-root access to OVS/OVN ---
|
|
echo ""
|
|
echo "Step 8: Configuring non-root access..."
|
|
|
|
# Open OVS DB socket so non-root processes can use ovs-vsctl
|
|
OVS_SOCK="/var/run/openvswitch/db.sock"
|
|
if [ -S "$OVS_SOCK" ]; then
|
|
sudo chmod 0666 "$OVS_SOCK"
|
|
echo " OVS DB socket: opened ($OVS_SOCK)"
|
|
fi
|
|
|
|
# Open OVN runtime directory and ctl sockets for ovs-appctl access
|
|
if [ -d "/var/run/ovn" ]; then
|
|
sudo chmod 0755 /var/run/ovn
|
|
sudo chmod 0666 /var/run/ovn/*.ctl 2>/dev/null || true
|
|
echo " OVN ctl sockets: opened (/var/run/ovn/)"
|
|
fi
|
|
if [ -d "/var/run/openvswitch" ]; then
|
|
sudo chmod 0666 /var/run/openvswitch/*.ctl 2>/dev/null || true
|
|
fi
|
|
|
|
# Create persistent systemd override so permissions survive OVS restarts
|
|
OVERRIDE_DIR="/etc/systemd/system/openvswitch-switch.service.d"
|
|
if [ ! -f "$OVERRIDE_DIR/spinifex-perms.conf" ]; then
|
|
sudo mkdir -p "$OVERRIDE_DIR"
|
|
sudo tee "$OVERRIDE_DIR/spinifex-perms.conf" >/dev/null <<'OVERRIDE'
|
|
[Service]
|
|
ExecStartPost=/bin/chmod 0666 /var/run/openvswitch/db.sock
|
|
OVERRIDE
|
|
sudo systemctl daemon-reload
|
|
echo " systemd override: created (db.sock permissions persist across restarts)"
|
|
else
|
|
echo " systemd override: already exists"
|
|
fi
|
|
|
|
# Create sudoers rule for network commands that always need root
|
|
# (ip tuntap, ip link set — NET_ADMIN operations)
|
|
SUDOERS_FILE="/etc/sudoers.d/spinifex-network"
|
|
if [ ! -f "$SUDOERS_FILE" ]; then
|
|
CURRENT_USER=$(whoami)
|
|
sudo tee "$SUDOERS_FILE" >/dev/null <<EOF
|
|
# Spinifex VPC networking: allow non-root daemon to manage tap devices and OVS
|
|
$CURRENT_USER ALL=(root) NOPASSWD: /sbin/ip, /usr/sbin/ip
|
|
$CURRENT_USER ALL=(root) NOPASSWD: /usr/bin/ovs-vsctl, /usr/bin/ovs-appctl
|
|
$CURRENT_USER ALL=(root) NOPASSWD: /usr/bin/ovn-nbctl, /usr/bin/ovn-sbctl
|
|
EOF
|
|
sudo chmod 0440 "$SUDOERS_FILE"
|
|
echo " sudoers rule: created ($SUDOERS_FILE)"
|
|
else
|
|
echo " sudoers rule: already exists"
|
|
fi
|
|
|
|
# --- Step 9: Configure OVN log rotation ---
|
|
# OVN has built-in rotation that renames foo.log → foo.log.log. A previous
|
|
# logrotate config used a *.log glob that caught those .log.log files too,
|
|
# creating .log.log.1 files that accumulated to 27GB. Fix: use explicit
|
|
# filenames so logrotate only touches the primary logs, not OVN's backups.
|
|
echo ""
|
|
echo "Step 9: Configuring OVN log rotation..."
|
|
|
|
# Clean up stale .log.log files from the old double-rotation bug
|
|
if ls /var/log/ovn/*.log.log* 1>/dev/null 2>&1; then
|
|
sudo rm -f /var/log/ovn/*.log.log*
|
|
echo " cleaned up stale .log.log files"
|
|
fi
|
|
|
|
LOGROTATE_FILE="/etc/logrotate.d/ovn-spinifex"
|
|
sudo tee "$LOGROTATE_FILE" >/dev/null <<'LOGROTATE'
|
|
/var/log/ovn/ovn-controller.log
|
|
/var/log/ovn/ovn-northd.log
|
|
/var/log/ovn/ovsdb-server-nb.log
|
|
/var/log/ovn/ovsdb-server-sb.log
|
|
{
|
|
daily
|
|
rotate 3
|
|
maxsize 100M
|
|
compress
|
|
missingok
|
|
notifempty
|
|
copytruncate
|
|
}
|
|
LOGROTATE
|
|
echo " logrotate config: $LOGROTATE_FILE (daily, 100M max, 3 rotations, explicit filenames)"
|
|
|
|
# --- Step 10: Disable auto-start on boot ---
|
|
# start-dev.sh / stop-dev.sh manage the OVN lifecycle. Without spinifex services
|
|
# running, ovn-controller spins in a tight reconnect loop burning CPU.
|
|
echo ""
|
|
echo "Step 10: Disabling OVN auto-start on boot (start-dev.sh will manage lifecycle)..."
|
|
sudo systemctl disable openvswitch-switch 2>/dev/null || true
|
|
sudo systemctl disable ovn-controller 2>/dev/null || true
|
|
echo " openvswitch-switch: disabled on boot"
|
|
echo " ovn-controller: disabled on boot"
|
|
|
|
# --- Step 11: Health check ---
|
|
echo ""
|
|
echo "Step 11: Verifying setup..."
|
|
|
|
OK=true
|
|
|
|
# Check br-int
|
|
if sudo ovs-vsctl br-exists br-int; then
|
|
echo " br-int: OK"
|
|
else
|
|
echo " br-int: FAILED"
|
|
OK=false
|
|
fi
|
|
|
|
# Check br-external (only if --external-bridge was used)
|
|
if [ "$EXTERNAL_BRIDGE" = true ]; then
|
|
if sudo ovs-vsctl br-exists br-external; then
|
|
echo " br-external: OK"
|
|
MACVLAN_NAME="spx-ext-${EXTERNAL_IFACE}"
|
|
if ip link show "$MACVLAN_NAME" >/dev/null 2>&1; then
|
|
echo " macvlan: OK ($MACVLAN_NAME)"
|
|
else
|
|
echo " macvlan: FAILED ($MACVLAN_NAME not found)"
|
|
OK=false
|
|
fi
|
|
else
|
|
echo " br-external: FAILED"
|
|
OK=false
|
|
fi
|
|
fi
|
|
|
|
# Check ovn-controller
|
|
if sudo ovs-appctl -t ovn-controller version >/dev/null 2>&1 || systemctl is-active --quiet ovn-controller 2>/dev/null; then
|
|
echo " ovn-controller: OK"
|
|
else
|
|
echo " ovn-controller: FAILED (may still be starting)"
|
|
OK=false
|
|
fi
|
|
|
|
# Check chassis registration (may take a moment)
|
|
if [ "$MANAGEMENT" = true ]; then
|
|
sleep 2
|
|
CHASSIS_COUNT=$(sudo ovn-sbctl show 2>/dev/null | grep -c "Chassis" || true)
|
|
echo " chassis count: $CHASSIS_COUNT"
|
|
fi
|
|
|
|
echo ""
|
|
if [ "$OK" = true ]; then
|
|
echo "=== OVN compute node setup complete ==="
|
|
else
|
|
echo "=== Setup completed with warnings (check above) ==="
|
|
fi
|