Josh Siviour 9427cdfc2d fix(test): give each predastore fixture its own S3 gate port (#775)
The fixture pinned its S3 gate to 127.0.0.1:18443. Three test binaries import
it and go test runs packages as concurrent processes, so two clusters raced
for the port. The loser did not fail cleanly: waitForReady probed the winner's
gate on the same port and reported healthy, so the setup client talked to
another process's cluster and failed with BucketAlreadyOwnedByYou.

Reserve a port per process instead, and reach the gate only through
Fixture.Host so it cannot be hardcoded again. A Start that fails partway now
drains the cluster before returning; its nodes hold process-wide pipe names
that a later attempt would otherwise collide with.