Files
spinifex/tests/e2e
Josh Siviour 7eff142c34 feat(e2e): bare-metal multi-node cluster support + density-aware guards (#227)
* feat(predastore): support 2-node distributed mode with RS(1,1)

Lower minimum node threshold from 3 to 2. Emit data=1,parity=1 when
exactly 2 nodes configured — effectively mirroring. 3+ nodes continue
to use RS(2,1).

* fix(ec2): route StartInstances back to original node with node-down fallback

ec2.start used a plain queue group, so NATS could route a restart request to
any daemon — including a capacity-constrained NUC that can't fit a second
instance. This caused InsufficientInstanceCapacity in the Phase 10 stop/start
test on 2-node bare-metal clusters where one node has significantly fewer
resources.

Each daemon now also subscribes to ec2.start.{nodeId} (no queue group). The
queue-group handler peeks at the instance ID, looks up LastNode from the
stopped KV, and forwards to ec2.start.{lastNode}. If the original node does
not respond within 5 seconds (down or partitioned), the handler falls back to
starting locally on whichever node picked up the request — preserving the
existing behaviour for node-failure scenarios.

The direct handler (ec2.start.{nodeId}) always starts locally and never
forwards, preventing routing loops.

* fix(ec2): fall back to local start when original node returns InsufficientInstanceCapacity

The forwarding handler was relaying all responses from the targeted node
unconditionally, including InsufficientInstanceCapacity. This meant that if
the NUC (node2) was the LastNode but had no remaining capacity, the error
propagated to the caller rather than falling back to the local node which may
have room.

Now only success and non-capacity errors are relayed; an InsufficientInstance-
Capacity response from the targeted node triggers a local start attempt, giving
any other node in the cluster a chance to absorb the instance.

* test(e2e): make VPC stop/start restart non-fatal on InsufficientInstanceCapacity

Asymmetric hardware (NUC node2) may not have capacity to restart all
VPC instances. IP-persists-while-stopped is still verified and fails
hard; restart verification is skipped with a warning on capacity errors.

* test(e2e): density-aware capacity guard across bare-metal multi-node suite

Sub-3-node bare-metal clusters with asymmetric/undersized nodes (e.g. a
4-vCPU NUC alongside a 16-vCPU box) can fit only one t3.nano on the
smallest node after the daemon's host reserve. Phases that direct or
indirectly land >1 instance on that node hit InsufficientInstanceCapacity
and previously hard-failed the entire suite.

Add is_density_skip helper and skip_test counter, and wrap every
density-sensitive run-instances / start-instances / wait-for-running call
site (phases 3, 5, 7, 10, 11) so capacity exhaustion on sub-3-node
clusters records a SKIP rather than a FAIL. On 3+ node clusters the
guard short-circuits to false, preserving existing failure semantics.

Summary block now prints Skipped count + names so degraded coverage is
visible in CI logs.

Refs: mulga-siv-72

* test(e2e): parameterise lb SSH key + user via PEER_SSH_KEY / PEER_SSH_USER

Allow run-lb-e2e.sh to run against clusters that don't use tf-user with the
tofu-cluster SSH key (e.g. bare-metal nodes which use spinifex@ + bm-ci key).
Defaults preserve existing behaviour on the tofu-cluster CI path.

Refs: mulga-siv-73