* fix: group-scope the OVS/OVN sockets and stop sudoing read-only probes The OVS DB socket and both sets of ctl sockets were chmod 0666 by setup-ovn.sh, with a systemd override re-applying it on every openvswitch-switch restart. Write access to db.sock is full control of the local datapath, so this handed the datapath to any account on the box. Both service users run with Group=spinifex, so the access is now 0660 root:spinifex, /var/run/ovn is 0750, and a shared helper re-applies it from ExecStartPost on openvswitch-switch and ovn-controller alike — the latter is new, and matters because the ovn-controller ctl socket name embeds the pid and is recreated on every start. That also fixes the health probe reporting ovn-controller as not_running on a healthy node. It shelled out to `sudo ovn-appctl`, which only spinifex-vpcd is granted; as spinifex-daemon sudo demanded a password and the swallowed error read as OVN being down. With the ctl socket group-owned the probe needs no privilege, so health.go moves to a non-escalating Runner rather than the alternative of granting the daemon a root-equivalent ovn-appctl rule to read a status. ListIMDSTaps ran `list-ports` plus one `get` per patch port on vpcd's 15s tick, so 1+N sudo invocations every tick, each one logging a pam_limits warning about the core rlimit the unit deliberately pins to 0. It now issues a single JSON query per pass, and the sudoers drop-in disables the PAM session for both service users, which also leaves sudo children inheriting the unit's rlimits. An absent iface-id on a patch port is now skipped with a warning instead of aborting the pass: it is the only record of the full ENI, so such a port cannot join the live set either way, and failing the pass stalled reconcile for every healthy port behind it. A transient query failure still aborts. * fix: group-own the OVS/OVN pidfiles too, and cover the ipsec ctl socket Group-owning the ctl sockets was not enough for `ovn-appctl -t ovn-controller`: it resolves the pid-named socket through the pidfile, and OVS opens that O_RDWR to test the fcntl liveness lock, so a group-readable pidfile still fails the probe with EACCES. The pidfiles now get the same 0660 root:spinifex, which also tightens them from the 0644 they ship with. openvswitch-ipsec joins the override list because setup-ovn.sh restarts it after the sweep runs, leaving its ctl socket as the one file still at the shipped mode. Verified on the dev node: every socket and pidfile is 0660 root:spinifex and survives a restart of all three units, an unprivileged user is refused, and /health reports ovn-controller ok where the sudo probe read not_running. * refactor: stop escalating the OVS/OVN socket clients Now that setup-ovn.sh group-owns the control sockets, ovs-vsctl, ovs-appctl, ovn-nbctl, ovn-sbctl, ovn-appctl and systemctl reach their daemons as the service user. utils.NeedsPrivilege carries that policy and both command builders consult it, so ip, iptables, dhcpcd, sysctl and arping still escalate while the socket clients no longer do. Their sudoers grants are removed: each took unrestricted args and all of them accept --log-file=PATH, so every one was a root-equivalent grant handed out to run a query. ovs-ofctl keeps its grant. It talks to a per-bridge <bridge>.mgmt socket that ovs-vswitchd creates when the bridge appears, including bridges spinifex creates at runtime, so the provisioning sweep cannot group-own it up front. The NB and SB database sockets join the sweep for ovn-nbctl and ovn-sbctl. vpcd carried its own sudoCommand copy that escalated unconditionally, bypassing the policy entirely. It survived only because the grants existed and broke the OVN flows-ready barrier the moment they were removed, so it now delegates to utils.SudoCommand. TestRG10_SudoOnlyThroughThePolicy fails the build if another package reintroduces a local copy. Verified on the dev node: an instance launches, IMDS is served, the flows-ready barrier completes, and no sudo denial appears anywhere in the journal. * refactor: drop every spinifex-vpcd sudoers grant for ambient capabilities vpcd held NOPASSWD grants for ip, iptables, sysctl and arping. The ip grant alone was root-equivalent: sudoers cannot constrain its arguments, so `sudo ip netns exec <ns> /bin/sh` was a root shell for the service account. The unit already grants CAP_NET_ADMIN and CAP_NET_RAW ambiently, and the kernel passes an ambient set to each child on exec, so those tools work as the service user with no escalation at all. Verified on a live node: all sixteen ip subcommands vpcd issues, plus iptables reads and writes, sysctl -w on the net.ipv4.neigh tree, and arping, all succeed under exactly the unit's ambient set. spinifex-vpcd now has no sudoers rules. NeedsPrivilege had to become capability-aware to do this. spx is one binary shared by both service units, and the daemon holds CAP_SYS_ADMIN and CAP_DAC_OVERRIDE but no CAP_NET_ADMIN, so a static tool list cannot express "vpcd runs ip directly, the daemon escalates it". The decision now reads CapAmb from /proc/self/status once and matches it against the capability each invocation needs. sysctl is resolved per key, since CAP_NET_ADMIN covers the net.* trees and nothing else. The dhcpcd grants go too: neither daemon invokes it. Only setup-ovn.sh, which runs as the provisioning user, and the in-guest ecs-agent. TestRG10_VPCDHoldsNoSudoersGrant pins both halves together, so a future grant cannot be re-added without also explaining why the capability stopped working. * chore: restore routeTree.gen.ts swept in by mistake * fix: probe ovn-controller with ovn-appctl, not ovs-appctl checkOVNController's first probe passed a bare -t ovn-controller to ovs-appctl, which resolves it against OVS_RUNDIR — /var/run/openvswitch. ovn-controller's socket and pidfile are in /var/run/ovn, so the probe could never succeed and logged "ovn-controller.pid: open: No such file or directory" on every check. Not a functional break: the next probe globs the full /var/run/ovn path and succeeds, so the function still returned nil. It cost an exec per check and made a healthy node look like it was failing an OVN liveness probe. ovn-appctl defaults OVS_RUNDIR to /var/run/ovn, so the common case now matches first. The glob and systemctl fallbacks stay for older layouts.
1176 lines
50 KiB
Bash
Executable File
1176 lines
50 KiB
Bash
Executable File
#!/bin/bash
|
|
|
|
# OVN Compute Node Setup for Spinifex VPC Networking
|
|
#
|
|
# This script bootstraps a compute node for OVN-based VPC networking:
|
|
# 1. Installs OVN/OVS packages (if not present)
|
|
# 2. Enables required services (openvswitch-switch, ovn-controller)
|
|
# 3. Creates br-int with secure fail-mode
|
|
# 4. Configures WAN bridge for public subnet uplink (auto-detected or manual)
|
|
# 5. Configures OVS external_ids for OVN chassis identity
|
|
# 6. Applies sysctl tuning for overlay networking
|
|
#
|
|
# Usage:
|
|
# ./scripts/setup-ovn.sh [options]
|
|
#
|
|
# Options:
|
|
# --management Also start OVN central services (NB DB, SB DB, ovn-northd)
|
|
# --wan-bridge=NAME OVS bridge for WAN traffic (default: auto-detect from default route)
|
|
# --wan-iface=NAME Physical NIC to add to the WAN bridge (use with --wan-bridge)
|
|
# --dhcp Obtain gateway IP via DHCP on the WAN bridge interface
|
|
# --nat-uplink Routed NAT mode: no WAN NIC is bridged. Creates br-ext
|
|
# with a transit veth (spx-nat-host 100.127.0.1/24) and
|
|
# host masquerade rules; VMs get outbound-only WAN over
|
|
# any uplink (ethernet, WiFi, cellular, PPP). Pair with
|
|
# `spx admin init --external-mode=nat`.
|
|
# --mgmt-bridge=NAME OVS bridge for system-instance control plane (default: br-mgmt)
|
|
# --mgmt-cidr=CIDR IPv4 CIDR to assign on the mgmt bridge (default: 10.15.8.1/24)
|
|
# --mgmt-iface=NAME Physical/virtual NIC to enslave to the mgmt bridge (multi-node only)
|
|
# --no-mgmt-bridge Skip mgmt bridge provisioning (for dev-networking hosts)
|
|
# --ovn-remote=ADDR OVN SB DB address; accepts a comma-separated list of
|
|
# SB endpoints for compute nodes pointing at a RAFT
|
|
# cluster (default: tcp:127.0.0.1:6642)
|
|
# --encap-ip=IP Geneve tunnel endpoint IP (default: auto-detect)
|
|
# --db-cluster-local-addr=IP This DB node's own IP for OVSDB RAFT clustering.
|
|
# Enables clustered NB(6643)/SB(6644) DBs (requires
|
|
# --management). Empty --db-cluster-remote-addr ⇒ create
|
|
# the cluster; set ⇒ join it.
|
|
# --db-cluster-remote-addr=IP An existing cluster DB node's IP to join. Omit
|
|
# on the first (init) DB node that forms the cluster.
|
|
#
|
|
# WAN Bridge Auto-Detection:
|
|
# When no --wan-bridge is given, the script checks the default route interface:
|
|
# - If it's an OVS bridge → use it directly for bridge-mappings
|
|
# - If it's a Linux bridge → create OVS br-ext + veth pair to link them
|
|
# (non-destructive, Linux bridge keeps IP/routes, no interruption)
|
|
# - If it's a physical NIC → stop and print guidance (cannot safely move NIC)
|
|
#
|
|
# Examples:
|
|
# # WAN is already on a bridge (tofu-cluster, production):
|
|
# ./scripts/setup-ovn.sh --management
|
|
#
|
|
# # Dedicated WAN NIC (not your SSH NIC — you take responsibility):
|
|
# ./scripts/setup-ovn.sh --management --wan-bridge=br-wan --wan-iface=eth1
|
|
#
|
|
# # Compute node joining an existing cluster:
|
|
# ./scripts/setup-ovn.sh --ovn-remote=tcp:10.0.0.1:6642 --encap-ip=10.0.0.2
|
|
#
|
|
# # DB node 1 — create an OVSDB RAFT cluster (init):
|
|
# ./scripts/setup-ovn.sh --management --db-cluster-local-addr=10.0.0.1
|
|
#
|
|
# # DB nodes 2,3 — join the cluster:
|
|
# ./scripts/setup-ovn.sh --management --db-cluster-local-addr=10.0.0.2 \
|
|
# --db-cluster-remote-addr=10.0.0.1
|
|
#
|
|
# # Compute node pointing at all 3 clustered SB endpoints:
|
|
# ./scripts/setup-ovn.sh --ovn-remote=tcp:10.0.0.1:6642,tcp:10.0.0.2:6642,tcp:10.0.0.3:6642
|
|
#
|
|
# # No WAN bridge (overlay-only, no public subnet):
|
|
# ./scripts/setup-ovn.sh --management --encap-ip=10.0.0.1
|
|
#
|
|
# # Non-bridgeable uplink (WiFi/cellular) — routed NAT, outbound-only VMs:
|
|
# ./scripts/setup-ovn.sh --management --nat-uplink
|
|
|
|
set -e
|
|
|
|
# Defaults
|
|
MANAGEMENT=false
|
|
WAN_BRIDGE=""
|
|
WAN_IFACE=""
|
|
EXTERNAL_DHCP=false
|
|
NAT_UPLINK=false
|
|
MGMT_BRIDGE_ENABLED=true
|
|
MGMT_BRIDGE="br-mgmt"
|
|
MGMT_CIDR="10.15.8.1/24"
|
|
MGMT_IFACE=""
|
|
OVN_REMOTE="tcp:127.0.0.1:6642"
|
|
ENCAP_IP=""
|
|
# OVSDB RAFT clustering. Empty by default ⇒ single, non-clustered ovn-central
|
|
# (dev box, existing single-node clusters). When LOCAL_ADDR is set, the NB/SB
|
|
# DBs run clustered; REMOTE_ADDR empty ⇒ create the cluster, set ⇒ join it.
|
|
DB_CLUSTER_LOCAL_ADDR=""
|
|
DB_CLUSTER_REMOTE_ADDR=""
|
|
# NODE_NAME is left empty by default. The chassis-id pin block at Step 4
|
|
# only runs when --node-name=NAME is explicitly given. Passing nothing
|
|
# preserves whatever system-id already lives in OVS (gold-image UUID,
|
|
# bootstrap-install.sh's pre-written nodeN, manual ansible value, etc.).
|
|
# Bootstrap callers that want IPsec-cert-identity matching pin the
|
|
# system-id themselves before / after invoking setup-ovn.sh — they
|
|
# don't need this script to do it for them.
|
|
NODE_NAME=""
|
|
|
|
# Parse arguments
|
|
for arg in "$@"; do
|
|
case "$arg" in
|
|
--management) MANAGEMENT=true ;;
|
|
--dhcp) EXTERNAL_DHCP=true ;;
|
|
--nat-uplink) NAT_UPLINK=true ;;
|
|
--wan-bridge=*) WAN_BRIDGE="${arg#*=}" ;;
|
|
--wan-iface=*) WAN_IFACE="${arg#*=}" ;;
|
|
--mgmt-bridge=*) MGMT_BRIDGE="${arg#*=}" ;;
|
|
--mgmt-cidr=*) MGMT_CIDR="${arg#*=}" ;;
|
|
--mgmt-iface=*) MGMT_IFACE="${arg#*=}" ;;
|
|
--no-mgmt-bridge) MGMT_BRIDGE_ENABLED=false ;;
|
|
--ovn-remote=*) OVN_REMOTE="${arg#*=}" ;;
|
|
--encap-ip=*) ENCAP_IP="${arg#*=}" ;;
|
|
--db-cluster-local-addr=*) DB_CLUSTER_LOCAL_ADDR="${arg#*=}" ;;
|
|
--db-cluster-remote-addr=*) DB_CLUSTER_REMOTE_ADDR="${arg#*=}" ;;
|
|
--node-name=*) NODE_NAME="${arg#*=}" ;;
|
|
--help|-h)
|
|
sed -n '3,/^set -e/{/^set -e/!p}' "$0"
|
|
exit 0
|
|
;;
|
|
*)
|
|
echo "Unknown option: $arg"
|
|
exit 1
|
|
;;
|
|
esac
|
|
done
|
|
|
|
# OVSDB RAFT clustering runs the NB/SB DBs, so it only applies to management
|
|
# (DB) nodes. A remote addr without a local addr is meaningless (nothing to
|
|
# join with). Fail loudly rather than silently starting a single-node DB.
|
|
if [ -n "$DB_CLUSTER_LOCAL_ADDR" ] && [ "$MANAGEMENT" != true ]; then
|
|
echo "ERROR: --db-cluster-local-addr requires --management (clustered DBs run on management nodes)"
|
|
exit 1
|
|
fi
|
|
if [ -n "$DB_CLUSTER_REMOTE_ADDR" ] && [ -z "$DB_CLUSTER_LOCAL_ADDR" ]; then
|
|
echo "ERROR: --db-cluster-remote-addr requires --db-cluster-local-addr"
|
|
exit 1
|
|
fi
|
|
|
|
# --- WAN bridge auto-detection ---
|
|
# Determine the WAN bridge name and how to set it up.
|
|
WAN_BRIDGE_MODE="" # "existing", "veth", "direct", or ""
|
|
LINUX_BRIDGE="" # Set when WAN_BRIDGE_MODE="veth" — the Linux bridge behind the veth pair
|
|
|
|
detect_wan_bridge() {
|
|
# If --wan-bridge was explicitly given, use it
|
|
if [ -n "$WAN_BRIDGE" ]; then
|
|
if [ -n "$WAN_IFACE" ]; then
|
|
WAN_BRIDGE_MODE="direct"
|
|
elif sudo ovs-vsctl br-exists "$WAN_BRIDGE" 2>/dev/null; then
|
|
WAN_BRIDGE_MODE="existing"
|
|
else
|
|
# Bridge doesn't exist yet and no --wan-iface — create empty OVS bridge
|
|
WAN_BRIDGE_MODE="existing"
|
|
fi
|
|
return
|
|
fi
|
|
|
|
# Auto-detect: find the default route interface
|
|
local default_dev
|
|
default_dev=$(ip -4 route show default 2>/dev/null | awk '{for(i=1;i<=NF;i++) if($i=="dev") print $(i+1)}' | head -1)
|
|
|
|
if [ -z "$default_dev" ]; then
|
|
echo " No default route found — no WAN bridge configured"
|
|
echo " (VMs will not have external connectivity)"
|
|
return
|
|
fi
|
|
|
|
# Check if the default route device is a bridge (Linux or OVS)
|
|
local is_bridge=false
|
|
if ip -d link show "$default_dev" 2>/dev/null | grep -q "bridge"; then
|
|
is_bridge=true
|
|
fi
|
|
if sudo ovs-vsctl br-exists "$default_dev" 2>/dev/null; then
|
|
is_bridge=true
|
|
fi
|
|
|
|
if [ "$is_bridge" = true ]; then
|
|
if sudo ovs-vsctl br-exists "$default_dev" 2>/dev/null; then
|
|
# Already an OVS bridge — use it directly for bridge-mappings
|
|
WAN_BRIDGE="$default_dev"
|
|
WAN_BRIDGE_MODE="existing"
|
|
echo " Auto-detected WAN bridge: $WAN_BRIDGE (OVS bridge, default route)"
|
|
else
|
|
# Linux bridge — link to OVS via veth pair (non-destructive)
|
|
LINUX_BRIDGE="$default_dev"
|
|
WAN_BRIDGE="br-ext"
|
|
WAN_BRIDGE_MODE="veth"
|
|
echo " Auto-detected Linux bridge: $LINUX_BRIDGE (default route)"
|
|
echo " Will create OVS bridge br-ext + veth pair to link them"
|
|
fi
|
|
return
|
|
fi
|
|
|
|
# Default route is a physical NIC — cannot safely move it to OVS
|
|
# because it might be carrying SSH.
|
|
local wan_ip
|
|
wan_ip=$(ip -4 -o addr show "$default_dev" 2>/dev/null | awk '{print $4}' | cut -d/ -f1 | head -1)
|
|
|
|
echo ""
|
|
echo "============================================================"
|
|
echo " WAN interface '$default_dev' ($wan_ip) is a physical NIC."
|
|
echo " Cannot auto-create a bridge — this may drop your connection."
|
|
echo ""
|
|
echo " Options:"
|
|
echo ""
|
|
echo " 1. Create a WAN bridge first (e.g. via netplan), then re-run:"
|
|
echo " ./scripts/setup-ovn.sh --management"
|
|
echo ""
|
|
echo " 2. Dedicated WAN NIC (NOT your SSH connection):"
|
|
echo " ./scripts/setup-ovn.sh --management --wan-bridge=br-wan --wan-iface=$default_dev"
|
|
echo ""
|
|
echo " 3. No external networking (overlay-only):"
|
|
echo " ./scripts/setup-ovn.sh --management --encap-ip=$wan_ip"
|
|
echo ""
|
|
echo " 4. Non-bridgeable uplink (WiFi/cellular/PPP) — routed NAT mode"
|
|
echo " (VMs get outbound-only internet, no public IPs):"
|
|
echo " ./scripts/setup-ovn.sh --management --nat-uplink"
|
|
echo " then: spx admin init --external-mode=nat"
|
|
echo "============================================================"
|
|
echo ""
|
|
exit 1
|
|
}
|
|
|
|
if [ "$NAT_UPLINK" = true ]; then
|
|
# Routed NAT: nothing is bridged, so the uplink type is irrelevant.
|
|
if [ -n "$WAN_BRIDGE" ] || [ -n "$WAN_IFACE" ]; then
|
|
echo "ERROR: --nat-uplink does not take --wan-bridge/--wan-iface (no WAN NIC is bridged)"
|
|
exit 1
|
|
fi
|
|
WAN_BRIDGE="br-ext"
|
|
WAN_BRIDGE_MODE="nat"
|
|
echo " Routed NAT uplink: br-ext + transit veth, host masquerade (no WAN bridge)"
|
|
else
|
|
detect_wan_bridge
|
|
fi
|
|
|
|
# Auto-detect encap IP if not specified
|
|
if [ -z "$ENCAP_IP" ]; then
|
|
# Prefer br-vpc IP if it exists (dedicated VPC data plane)
|
|
if ip -4 addr show br-vpc >/dev/null 2>&1; then
|
|
ENCAP_IP=$(ip -4 -o addr show br-vpc 2>/dev/null | awk '{print $4}' | cut -d/ -f1 | head -1)
|
|
if [ -n "$ENCAP_IP" ]; then
|
|
echo "Auto-detected encap IP from br-vpc: $ENCAP_IP"
|
|
fi
|
|
fi
|
|
# Fall back to default route source IP
|
|
if [ -z "$ENCAP_IP" ]; then
|
|
ENCAP_IP=$(ip -4 route get 8.8.8.8 2>/dev/null | awk '/src/{print $7}' | head -1)
|
|
if [ -z "$ENCAP_IP" ]; then
|
|
ENCAP_IP="127.0.0.1"
|
|
fi
|
|
echo "Auto-detected encap IP: $ENCAP_IP"
|
|
fi
|
|
fi
|
|
|
|
echo "=== Spinifex OVN Compute Node Setup ==="
|
|
echo " Management node: $MANAGEMENT"
|
|
if [ -n "$DB_CLUSTER_LOCAL_ADDR" ]; then
|
|
if [ -n "$DB_CLUSTER_REMOTE_ADDR" ]; then
|
|
echo " DB RAFT role: join (local=$DB_CLUSTER_LOCAL_ADDR remote=$DB_CLUSTER_REMOTE_ADDR)"
|
|
else
|
|
echo " DB RAFT role: create (local=$DB_CLUSTER_LOCAL_ADDR)"
|
|
fi
|
|
fi
|
|
if [ -n "$WAN_BRIDGE" ]; then
|
|
echo " WAN bridge: $WAN_BRIDGE ($WAN_BRIDGE_MODE)"
|
|
if [ -n "$LINUX_BRIDGE" ]; then
|
|
echo " Linux bridge: $LINUX_BRIDGE (linked via veth pair)"
|
|
fi
|
|
if [ -n "$WAN_IFACE" ]; then
|
|
echo " WAN interface: $WAN_IFACE"
|
|
fi
|
|
else
|
|
echo " WAN bridge: none (overlay-only)"
|
|
fi
|
|
echo " OVN Remote (SB): $OVN_REMOTE"
|
|
echo " Encap IP: $ENCAP_IP"
|
|
echo ""
|
|
|
|
# Packages (openvswitch-switch, ovn-host, openvswitch-ipsec, strongswan-charon,
|
|
# and ovn-central on management nodes) are baked into the gold image via
|
|
# scripts/tofu-cluster/image-builder/scripts/provision.sh. Runtime apt-get
|
|
# was removed to keep CI off the (flaky) apt-cacher-ng path. If a package is
|
|
# missing, the downstream ovs/ovn commands will fail loudly — the fix is to
|
|
# rebuild the gold image, not to re-add apt-get here.
|
|
|
|
# strongswan-charon ships an AppArmor profile for /usr/lib/ipsec/charon that
|
|
# only allows reading from /etc/ipsec.*, /etc/strongswan.*, and a few other
|
|
# fixed paths. ovs-monitor-ipsec writes the per-tunnel strongSwan config with
|
|
# absolute paths to our peer cert + key under /etc/spinifex/ipsec/ AND to the
|
|
# cluster CA at /etc/spinifex/ca.pem, so charon hits "Permission denied" on
|
|
# both load paths and surfaces as `no trusted RSA public key found for
|
|
# '<peer>'` (CA can't be loaded → can't validate peer cert chain → no SAs).
|
|
# The profile includes a 'local' override file expressly for site additions
|
|
# — grant reads on /etc/spinifex/** (covers ca.pem AND ipsec/peer.{pem,key})
|
|
# and reload.
|
|
if [ -d /etc/apparmor.d/local ]; then
|
|
LOCAL_OVERRIDE=/etc/apparmor.d/local/usr.lib.ipsec.charon
|
|
# Always rewrite — re-runs may have an older, narrower rule (e.g. the
|
|
# initial /etc/spinifex/ipsec/** only) that misses /etc/spinifex/ca.pem.
|
|
echo " Adding AppArmor read grant for /etc/spinifex (cert + CA) to charon profile"
|
|
echo "/etc/spinifex/** r," | sudo tee "$LOCAL_OVERRIDE" >/dev/null
|
|
sudo apparmor_parser -r /etc/apparmor.d/usr.lib.ipsec.charon 2>/dev/null || true
|
|
fi
|
|
|
|
# --- Step 2: Enable services ---
|
|
echo ""
|
|
echo "Step 2: Enabling services..."
|
|
|
|
sudo systemctl enable openvswitch-switch
|
|
sudo systemctl start openvswitch-switch
|
|
echo " openvswitch-switch: started"
|
|
|
|
if [ "$MANAGEMENT" = true ]; then
|
|
sudo systemctl enable ovn-central
|
|
|
|
if [ -n "$DB_CLUSTER_LOCAL_ADDR" ]; then
|
|
# Clustered NB/SB via native OVSDB RAFT. Both per-DB units source one
|
|
# shared OVN_CTL_OPTS from /etc/default/ovn-central; each run_*_ovsdb
|
|
# consumes only its own --db-{nb,sb}-* flags. RAFT ports default to NB
|
|
# 6643 / SB 6644. ovn-ctl creates the cluster when no remote-addr is
|
|
# given (and no existing .db file), joins when one is.
|
|
OVN_CTL_OPTS="--db-nb-cluster-local-addr=$DB_CLUSTER_LOCAL_ADDR --db-sb-cluster-local-addr=$DB_CLUSTER_LOCAL_ADDR"
|
|
if [ -n "$DB_CLUSTER_REMOTE_ADDR" ]; then
|
|
OVN_CTL_OPTS="$OVN_CTL_OPTS --db-nb-cluster-remote-addr=$DB_CLUSTER_REMOTE_ADDR --db-sb-cluster-remote-addr=$DB_CLUSTER_REMOTE_ADDR"
|
|
echo " ovn-central: joining RAFT cluster (local=$DB_CLUSTER_LOCAL_ADDR remote=$DB_CLUSTER_REMOTE_ADDR)"
|
|
else
|
|
echo " ovn-central: creating RAFT cluster (local=$DB_CLUSTER_LOCAL_ADDR)"
|
|
fi
|
|
|
|
# Point ovn-northd's client NB/SB connections at the full RAFT member
|
|
# list so the active northd follows the leader. Without this it dials the
|
|
# local member only and stops advancing SB_Global.nb_cfg once leadership
|
|
# moves off this node, wedging the ovn-nbctl --wait=hv flows barrier.
|
|
# Derived from OVN_REMOTE (the SB list); the NB list is the same hosts on
|
|
# 6641. Skipped when OVN_REMOTE is the localhost default (caller passed no
|
|
# member list) so a lone standalone DB node is unaffected.
|
|
if [ "$OVN_REMOTE" != "tcp:127.0.0.1:6642" ]; then
|
|
OVN_REMOTE_NB="${OVN_REMOTE//:6642/:6641}"
|
|
OVN_CTL_OPTS="$OVN_CTL_OPTS --ovn-northd-nb-db=$OVN_REMOTE_NB --ovn-northd-sb-db=$OVN_REMOTE"
|
|
echo " ovn-northd: NB=$OVN_REMOTE_NB SB=$OVN_REMOTE (RAFT member list)"
|
|
fi
|
|
|
|
echo "OVN_CTL_OPTS=\"$OVN_CTL_OPTS\"" | sudo tee /etc/default/ovn-central >/dev/null
|
|
echo " wrote /etc/default/ovn-central"
|
|
|
|
# The packaged ovn-northd.service ExecStop runs `ovn-ctl stop_northd`
|
|
# without --ovn-manage-ovsdb=no, so restarting northd also tears down the
|
|
# NB/SB ovsdb-server units. With the split clustered units those DBs are
|
|
# owned by their own units, so override ExecStop to leave them alone —
|
|
# otherwise the restart below races and kills the freshly-started DBs.
|
|
sudo mkdir -p /etc/systemd/system/ovn-northd.service.d
|
|
sudo tee /etc/systemd/system/ovn-northd.service.d/no-manage-ovsdb.conf >/dev/null <<'EOF'
|
|
[Service]
|
|
ExecStop=
|
|
ExecStop=/usr/share/ovn/scripts/ovn-ctl stop_northd --no-monitor --ovn-manage-ovsdb=no
|
|
EOF
|
|
sudo systemctl daemon-reload
|
|
|
|
# The ovn-central aggregator is ExecStart=/bin/true, so restarting it
|
|
# won't restart the children — restart the per-DB units directly to
|
|
# pick up the new OVN_CTL_OPTS.
|
|
sudo systemctl restart ovn-ovsdb-server-nb ovn-ovsdb-server-sb ovn-northd
|
|
echo " ovn-central: started clustered (NB DB + SB DB + ovn-northd)"
|
|
else
|
|
sudo systemctl start ovn-central
|
|
echo " ovn-central: started (NB DB + SB DB + ovn-northd)"
|
|
fi
|
|
|
|
# Wait for OVN NB DB socket to become available
|
|
for i in $(seq 1 15); do
|
|
if sudo ovn-nbctl --timeout=2 get-connection >/dev/null 2>&1; then
|
|
break
|
|
fi
|
|
echo " Waiting for OVN NB DB... ($i/15)"
|
|
sleep 1
|
|
done
|
|
|
|
# Wait for the Southbound DB to be serving before ovn-controller (Step 5)
|
|
# dials it. On a single node ovn-controller races a fresh SB RAFT election
|
|
# with no join step to absorb the window — attaching before the leader is
|
|
# elected (and before northd writes the gateway logical flows) leaves it with
|
|
# a partial datapath that never reconverges. Gate on SB reachable and, when
|
|
# clustered, an elected leader.
|
|
for i in $(seq 1 30); do
|
|
if sudo ovn-sbctl --timeout=2 show >/dev/null 2>&1; then
|
|
if [ -z "$DB_CLUSTER_LOCAL_ADDR" ]; then
|
|
break
|
|
fi
|
|
SB_LEADER=$(sudo ovs-appctl -t /var/run/ovn/ovnsb_db.ctl \
|
|
cluster/status OVN_Southbound 2>/dev/null \
|
|
| awk '/^Leader:/{print $2; exit}')
|
|
if [ -n "$SB_LEADER" ] && [ "$SB_LEADER" != "unknown" ]; then
|
|
break
|
|
fi
|
|
fi
|
|
echo " Waiting for OVN SB DB leader... ($i/30)"
|
|
sleep 1
|
|
done
|
|
|
|
# Set the NB/SB client listen addresses. set-connection writes through RAFT
|
|
# (replicated cluster-wide), so it only runs on the create node — a joining
|
|
# node would redirect to the leader, which the init node already configured.
|
|
if [ -z "$DB_CLUSTER_REMOTE_ADDR" ]; then
|
|
sudo ovn-nbctl set-connection ptcp:6641
|
|
sudo ovn-sbctl set-connection ptcp:6642
|
|
echo " OVN NB DB listening on tcp:6641"
|
|
echo " OVN SB DB listening on tcp:6642"
|
|
fi
|
|
fi
|
|
|
|
# --- Step 3: Create and configure br-int ---
|
|
echo ""
|
|
echo "Step 3: Configuring br-int..."
|
|
|
|
sudo ovs-vsctl --may-exist add-br br-int
|
|
sudo ovs-vsctl set Bridge br-int fail-mode=secure
|
|
sudo ovs-vsctl set Bridge br-int other-config:disable-in-band=true
|
|
sudo ip link set br-int up
|
|
echo " br-int: created, fail-mode=secure, up"
|
|
|
|
# Mark OVS internal netdevs Unmanaged for systemd-networkd. Without this,
|
|
# Trixie's networkd takes ownership of any unconfigured iface and may bring
|
|
# br-int/br-ext admin-down after setup-ovn.sh's `ip link set up` (no Match
|
|
# rule => default management => no carrier => link down). OVS dataplane
|
|
# still forwards, but ovn-controller flow programming and any tooling that
|
|
# probes link state misbehave. Unmanaged=yes keeps OVS in sole control.
|
|
OVS_INTERNAL_NET=/etc/systemd/network/05-spinifex-ovs-internal.network
|
|
if [ ! -f "$OVS_INTERNAL_NET" ]; then
|
|
sudo tee "$OVS_INTERNAL_NET" >/dev/null <<'NETWORK'
|
|
[Match]
|
|
Name=br-int br-ext
|
|
|
|
[Link]
|
|
Unmanaged=yes
|
|
NETWORK
|
|
sudo networkctl reload 2>/dev/null || true
|
|
echo " wrote $OVS_INTERNAL_NET (Unmanaged=yes for br-int br-ext)"
|
|
fi
|
|
|
|
# --- Step 3b: Configure WAN bridge for public subnet uplink ---
|
|
if [ -n "$WAN_BRIDGE" ]; then
|
|
echo ""
|
|
echo "Step 3b: Configuring WAN bridge ($WAN_BRIDGE) for public subnet uplink..."
|
|
|
|
# Rip down any stale veth persistence from a previous veth-mode install
|
|
# when switching to any non-veth mode. Idempotent — each command uses
|
|
# --if-exists / 2>/dev/null to tolerate absence. Without this, the
|
|
# veth pair re-materialises on reboot and fights the current mode's
|
|
# bridge plumbing (Fix 1, mulga-998.b, per D17).
|
|
if [ "$WAN_BRIDGE_MODE" != "veth" ]; then
|
|
sudo rm -f /etc/systemd/network/14-spinifex-br-wan.netdev \
|
|
/etc/systemd/network/15-spinifex-veth-wan.netdev \
|
|
/etc/systemd/network/15-spinifex-veth-wan.network \
|
|
/etc/systemd/network/16-spinifex-veth-wan-ovs.network
|
|
sudo networkctl reload 2>/dev/null || true
|
|
sudo ovs-vsctl --if-exists del-port veth-wan-ovs 2>/dev/null || true
|
|
sudo ip link del veth-wan-br 2>/dev/null || true
|
|
fi
|
|
|
|
# Same ripdown for stale routed-NAT plumbing when switching away from nat.
|
|
if [ "$WAN_BRIDGE_MODE" != "nat" ]; then
|
|
sudo rm -f /etc/systemd/network/17-spinifex-nat.netdev \
|
|
/etc/systemd/network/17-spinifex-nat.network \
|
|
/etc/systemd/network/18-spinifex-nat-ovs.network
|
|
sudo networkctl reload 2>/dev/null || true
|
|
sudo ovs-vsctl --if-exists del-port spx-nat-ovs 2>/dev/null || true
|
|
sudo ip link del spx-nat-host 2>/dev/null || true
|
|
fi
|
|
|
|
case "$WAN_BRIDGE_MODE" in
|
|
existing)
|
|
# Already an OVS bridge (from a previous run or explicit --wan-bridge).
|
|
if ! sudo ovs-vsctl br-exists "$WAN_BRIDGE" 2>/dev/null; then
|
|
sudo ovs-vsctl --may-exist add-br "$WAN_BRIDGE"
|
|
echo " created OVS bridge: $WAN_BRIDGE"
|
|
fi
|
|
sudo ip link set "$WAN_BRIDGE" up
|
|
echo " $WAN_BRIDGE: OVS bridge, up"
|
|
;;
|
|
|
|
veth)
|
|
# Linux bridge detected (e.g. br-wan from cloud-init/netplan).
|
|
# OVN bridge-mappings require an OVS bridge. Rather than converting
|
|
# the Linux bridge (destructive, causes WAN interruption), we create
|
|
# a separate OVS bridge and link them with a veth pair:
|
|
#
|
|
# br-wan (Linux, keeps IP/routes) ←→ veth pair ←→ br-ext (OVS, for OVN)
|
|
#
|
|
# No network interruption. The Linux bridge is untouched.
|
|
|
|
# Create OVS bridge
|
|
if ! sudo ovs-vsctl br-exists "$WAN_BRIDGE" 2>/dev/null; then
|
|
sudo ovs-vsctl --may-exist add-br "$WAN_BRIDGE"
|
|
echo " created OVS bridge: $WAN_BRIDGE"
|
|
fi
|
|
sudo ip link set "$WAN_BRIDGE" up
|
|
|
|
# Create veth pair (idempotent)
|
|
if ! ip link show veth-wan-br >/dev/null 2>&1; then
|
|
sudo ip link add veth-wan-br type veth peer name veth-wan-ovs
|
|
echo " created veth pair: veth-wan-br ↔ veth-wan-ovs"
|
|
else
|
|
echo " veth pair already exists: veth-wan-br ↔ veth-wan-ovs"
|
|
fi
|
|
|
|
# Enslave veth-wan-br to the Linux bridge
|
|
if ! ip link show veth-wan-br 2>/dev/null | grep -q "master $LINUX_BRIDGE"; then
|
|
sudo ip link set veth-wan-br master "$LINUX_BRIDGE"
|
|
echo " veth-wan-br → $LINUX_BRIDGE (Linux bridge)"
|
|
fi
|
|
sudo ip link set veth-wan-br up
|
|
|
|
# Add veth-wan-ovs to the OVS bridge
|
|
if ! sudo ovs-vsctl port-to-br veth-wan-ovs >/dev/null 2>&1; then
|
|
sudo ovs-vsctl --may-exist add-port "$WAN_BRIDGE" veth-wan-ovs
|
|
echo " veth-wan-ovs → $WAN_BRIDGE (OVS bridge)"
|
|
fi
|
|
sudo ip link set veth-wan-ovs up
|
|
|
|
echo " $LINUX_BRIDGE (Linux) ↔ veth pair ↔ $WAN_BRIDGE (OVS)"
|
|
echo " $LINUX_BRIDGE keeps its IP and routes — no interruption"
|
|
|
|
# Persist the veth pair across reboot via systemd-networkd. Veths
|
|
# are kernel-only and vanish on reboot; without persistence vpcd
|
|
# starts with the OVS port pointing at a nonexistent peer and
|
|
# silently falls back to direct mode (Fix 1, mulga-998.b).
|
|
#
|
|
# networkd's Bridge= directive requires the target bridge to be a
|
|
# known NetDev. On ISO-installed nodes the installer writes
|
|
# 11-spinifex-br-wan.netdev, which the gate below detects and
|
|
# skips this write. On binary-installed nodes where the operator
|
|
# manages br-wan outside networkd (e.g. cloud-init), this file
|
|
# fills the gap so veth-wan-br resolves its bridge on reboot.
|
|
# `Failed to create netdev: File exists` is harmless — networkd
|
|
# matches the existing kernel bridge by name+kind.
|
|
#
|
|
# Gate: skip the write if any .netdev (installer, cloud-init,
|
|
# netplan, manual) already declares this bridge — don't clobber
|
|
# existing networkd config. networkd searches /etc, /run, /usr/lib;
|
|
# check all three. Our own file is excluded so idempotent re-runs
|
|
# still rewrite when needed.
|
|
BR_WAN_NETDEV="/etc/systemd/network/14-spinifex-br-wan.netdev"
|
|
VETH_NETDEV="/etc/systemd/network/15-spinifex-veth-wan.netdev"
|
|
VETH_NETWORK="/etc/systemd/network/15-spinifex-veth-wan.network"
|
|
VETH_OVS_NETWORK="/etc/systemd/network/16-spinifex-veth-wan-ovs.network"
|
|
EXISTING_BR_NETDEV=$(grep -rls --include="*.netdev" -E "^\s*Name=$LINUX_BRIDGE\s*$" \
|
|
/etc/systemd/network /run/systemd/network /usr/lib/systemd/network 2>/dev/null \
|
|
| grep -v "^$BR_WAN_NETDEV$" || true)
|
|
if [ -n "$EXISTING_BR_NETDEV" ]; then
|
|
echo " skipping $BR_WAN_NETDEV — operator-managed NetDev already declares $LINUX_BRIDGE: $EXISTING_BR_NETDEV"
|
|
else
|
|
sudo tee "$BR_WAN_NETDEV" >/dev/null <<NETDEV
|
|
[NetDev]
|
|
Name=$LINUX_BRIDGE
|
|
Kind=bridge
|
|
NETDEV
|
|
fi
|
|
sudo tee "$VETH_NETDEV" >/dev/null <<NETDEV
|
|
[NetDev]
|
|
Name=veth-wan-br
|
|
Kind=veth
|
|
|
|
[Peer]
|
|
Name=veth-wan-ovs
|
|
NETDEV
|
|
sudo tee "$VETH_NETWORK" >/dev/null <<NETWORK
|
|
[Match]
|
|
Name=veth-wan-br
|
|
|
|
[Network]
|
|
Bridge=$LINUX_BRIDGE
|
|
ConfigureWithoutCarrier=yes
|
|
NETWORK
|
|
# Second unit admin-ups the OVS end of the pair. OVS owns the port
|
|
# (enslaved via ovs-vsctl add-port above) but does not flip admin
|
|
# state on external ports — that's networkd's job. Without this,
|
|
# veth-wan-ovs stays DOWN after reboot, peer goes LOWERLAYERDOWN,
|
|
# br-wan loses carrier (Fix 1 follow-up, mulga-998.b).
|
|
sudo tee "$VETH_OVS_NETWORK" >/dev/null <<NETWORK
|
|
[Match]
|
|
Name=veth-wan-ovs
|
|
|
|
[Link]
|
|
RequiredForOnline=no
|
|
|
|
[Network]
|
|
ConfigureWithoutCarrier=yes
|
|
NETWORK
|
|
sudo networkctl reload 2>/dev/null || true
|
|
echo " wrote $VETH_NETDEV + $VETH_NETWORK + $VETH_OVS_NETWORK (veth persists on reboot)"
|
|
;;
|
|
|
|
direct)
|
|
# Add WAN NIC directly to OVS bridge. The NIC becomes an OVS slave —
|
|
# its IP (if any) is no longer reachable from the host. The user has
|
|
# confirmed this NIC is NOT their SSH connection.
|
|
if ! ip link show "$WAN_IFACE" >/dev/null 2>&1; then
|
|
echo " ERROR: interface $WAN_IFACE does not exist"
|
|
echo " Available interfaces:"
|
|
ip -o link show | awk -F': ' '{print " " $2}'
|
|
exit 1
|
|
fi
|
|
|
|
sudo ovs-vsctl --may-exist add-br "$WAN_BRIDGE"
|
|
sudo ip link set "$WAN_BRIDGE" up
|
|
|
|
if sudo ovs-vsctl port-to-br "$WAN_IFACE" >/dev/null 2>&1; then
|
|
echo " $WAN_IFACE already on $(sudo ovs-vsctl port-to-br "$WAN_IFACE")"
|
|
else
|
|
sudo ovs-vsctl --may-exist add-port "$WAN_BRIDGE" "$WAN_IFACE"
|
|
echo " added $WAN_IFACE directly to $WAN_BRIDGE"
|
|
fi
|
|
sudo ip link set "$WAN_IFACE" up
|
|
echo " $WAN_BRIDGE: direct bridge on $WAN_IFACE"
|
|
echo " NOTE: $WAN_IFACE is now an OVS port — no host IP on this NIC"
|
|
;;
|
|
|
|
nat)
|
|
# Routed NAT: br-ext carries no WAN NIC. A transit veth pair links
|
|
# it to the host stack (spx-nat-host owns 100.127.0.1/24); the host
|
|
# forwards and masquerades the transit /24 out whatever uplink it
|
|
# has. OVN SNATs each VPC CIDR to its gateway LRP transit IP, so
|
|
# the masquerade rule below is the only host-side NAT state.
|
|
NAT_TRANSIT_CIDR="100.127.0.0/24"
|
|
NAT_TRANSIT_GW_CIDR="100.127.0.1/24"
|
|
|
|
if ! sudo ovs-vsctl br-exists "$WAN_BRIDGE" 2>/dev/null; then
|
|
sudo ovs-vsctl --may-exist add-br "$WAN_BRIDGE"
|
|
echo " created OVS bridge: $WAN_BRIDGE"
|
|
fi
|
|
sudo ip link set "$WAN_BRIDGE" up
|
|
|
|
# Create transit veth pair (idempotent)
|
|
if ! ip link show spx-nat-host >/dev/null 2>&1; then
|
|
sudo ip link add spx-nat-host type veth peer name spx-nat-ovs
|
|
echo " created veth pair: spx-nat-host ↔ spx-nat-ovs"
|
|
else
|
|
echo " veth pair already exists: spx-nat-host ↔ spx-nat-ovs"
|
|
fi
|
|
sudo ip addr replace "$NAT_TRANSIT_GW_CIDR" dev spx-nat-host
|
|
|
|
# Add the OVS end to br-ext
|
|
if ! sudo ovs-vsctl port-to-br spx-nat-ovs >/dev/null 2>&1; then
|
|
sudo ovs-vsctl --may-exist add-port "$WAN_BRIDGE" spx-nat-ovs
|
|
echo " spx-nat-ovs → $WAN_BRIDGE (OVS bridge)"
|
|
fi
|
|
sudo ip link set spx-nat-host up
|
|
sudo ip link set spx-nat-ovs up
|
|
echo " host (spx-nat-host $NAT_TRANSIT_GW_CIDR) ↔ veth pair ↔ $WAN_BRIDGE (OVS)"
|
|
|
|
# Persist the veth pair + transit IP across reboot (veths are
|
|
# kernel-only; same rationale as veth mode above).
|
|
NAT_NETDEV="/etc/systemd/network/17-spinifex-nat.netdev"
|
|
NAT_NETWORK="/etc/systemd/network/17-spinifex-nat.network"
|
|
NAT_OVS_NETWORK="/etc/systemd/network/18-spinifex-nat-ovs.network"
|
|
sudo tee "$NAT_NETDEV" >/dev/null <<NETDEV
|
|
[NetDev]
|
|
Name=spx-nat-host
|
|
Kind=veth
|
|
|
|
[Peer]
|
|
Name=spx-nat-ovs
|
|
NETDEV
|
|
sudo tee "$NAT_NETWORK" >/dev/null <<NETWORK
|
|
[Match]
|
|
Name=spx-nat-host
|
|
|
|
[Network]
|
|
Address=$NAT_TRANSIT_GW_CIDR
|
|
ConfigureWithoutCarrier=yes
|
|
NETWORK
|
|
# Admin-up the OVS end after reboot (OVS owns the port but does
|
|
# not flip admin state on external ports — same as veth mode).
|
|
sudo tee "$NAT_OVS_NETWORK" >/dev/null <<NETWORK
|
|
[Match]
|
|
Name=spx-nat-ovs
|
|
|
|
[Link]
|
|
RequiredForOnline=no
|
|
|
|
[Network]
|
|
ConfigureWithoutCarrier=yes
|
|
NETWORK
|
|
sudo networkctl reload 2>/dev/null || true
|
|
echo " wrote $NAT_NETDEV + $NAT_NETWORK + $NAT_OVS_NETWORK (transit veth persists on reboot)"
|
|
|
|
# Kernel egress: masquerade the transit /24 out any uplink and
|
|
# accept forwarded transit traffic even under FORWARD-policy DROP.
|
|
# vpcd re-ensures these on every start; installing here too means
|
|
# the wiring is testable before services run.
|
|
sudo iptables -t nat -C POSTROUTING -s "$NAT_TRANSIT_CIDR" ! -d "$NAT_TRANSIT_CIDR" \
|
|
-m comment --comment "spinifex-nat-egress" -j MASQUERADE 2>/dev/null || \
|
|
sudo iptables -t nat -A POSTROUTING -s "$NAT_TRANSIT_CIDR" ! -d "$NAT_TRANSIT_CIDR" \
|
|
-m comment --comment "spinifex-nat-egress" -j MASQUERADE
|
|
sudo iptables -C FORWARD -i spx-nat-host -s "$NAT_TRANSIT_CIDR" \
|
|
-m comment --comment "spinifex-nat-egress" -j ACCEPT 2>/dev/null || \
|
|
sudo iptables -A FORWARD -i spx-nat-host -s "$NAT_TRANSIT_CIDR" \
|
|
-m comment --comment "spinifex-nat-egress" -j ACCEPT
|
|
sudo iptables -C FORWARD -o spx-nat-host -m conntrack --ctstate RELATED,ESTABLISHED \
|
|
-m comment --comment "spinifex-nat-egress" -j ACCEPT 2>/dev/null || \
|
|
sudo iptables -A FORWARD -o spx-nat-host -m conntrack --ctstate RELATED,ESTABLISHED \
|
|
-m comment --comment "spinifex-nat-egress" -j ACCEPT
|
|
echo " installed masquerade + forward rules for $NAT_TRANSIT_CIDR (comment: spinifex-nat-egress)"
|
|
;;
|
|
esac
|
|
|
|
# --- DHCP: obtain gateway IP for OVN SNAT ---
|
|
if [ "$EXTERNAL_DHCP" = true ] && [ "$WAN_BRIDGE_MODE" = "nat" ]; then
|
|
echo ""
|
|
echo " Skipping --dhcp: routed NAT mode has a fixed transit gateway (100.127.0.1)"
|
|
elif [ "$EXTERNAL_DHCP" = true ]; then
|
|
echo ""
|
|
echo "Step 3c: Obtaining external gateway IP via DHCP..."
|
|
|
|
# DHCP on the WAN bridge itself (direct/existing/veth).
|
|
DHCP_IFACE="$WAN_BRIDGE"
|
|
|
|
# Run DHCP client to get a lease
|
|
if command -v dhcpcd >/dev/null 2>&1; then
|
|
sudo dhcpcd --waitip=4 --timeout 15 "$DHCP_IFACE" 2>/dev/null || true
|
|
elif command -v dhclient >/dev/null 2>&1; then
|
|
sudo dhclient -1 -timeout 15 "$DHCP_IFACE" 2>/dev/null || true
|
|
else
|
|
echo " WARNING: no DHCP client found (dhcpcd or dhclient)"
|
|
echo " Install dhcpcd-base or isc-dhcp-client, or set gateway_ip manually"
|
|
fi
|
|
|
|
# Read the obtained IP
|
|
DHCP_IP=$(ip -4 addr show dev "$DHCP_IFACE" 2>/dev/null | awk '/inet /{print $2}' | head -1 | cut -d/ -f1)
|
|
if [ -n "$DHCP_IP" ]; then
|
|
echo " DHCP obtained: $DHCP_IP on $DHCP_IFACE"
|
|
|
|
# Write the gateway IP to the spinifex config so vpcd can use it
|
|
CONFIG_DIR="${CONFIG_DIR:-$HOME/spinifex/config}"
|
|
CONFIG_FILE="$CONFIG_DIR/spinifex.toml"
|
|
if [ -f "$CONFIG_FILE" ]; then
|
|
if grep -q "gateway_ip" "$CONFIG_FILE"; then
|
|
sed -i "s/gateway_ip.*/gateway_ip = \"$DHCP_IP\"/" "$CONFIG_FILE"
|
|
else
|
|
sed -i "/^gateway *=.*/a gateway_ip = \"$DHCP_IP\"" "$CONFIG_FILE"
|
|
fi
|
|
echo " Updated $CONFIG_FILE with gateway_ip = $DHCP_IP"
|
|
else
|
|
echo " WARNING: $CONFIG_FILE not found — set gateway_ip manually"
|
|
fi
|
|
else
|
|
echo " WARNING: DHCP failed to obtain IP on $DHCP_IFACE"
|
|
echo " VMs will not have external connectivity until gateway_ip is configured"
|
|
fi
|
|
fi
|
|
fi
|
|
|
|
# --- Step 3d: Management bridge for system-instance control plane ---
|
|
# br-mgmt is an OVS bridge (not L2-learning Linux bridge, not part of OVN
|
|
# overlay). fail-mode=standalone makes it behave like a plain L2 switch
|
|
# without OVN flows; it is excluded from ovn-bridge-mappings so
|
|
# ovn-controller ignores it. System instance TAPs attach via ovs-vsctl
|
|
# add-port (see SetupMgmtTapDevice in daemon/network.go).
|
|
if [ "$MGMT_BRIDGE_ENABLED" = true ]; then
|
|
echo ""
|
|
echo "Step 3d: Configuring management bridge ($MGMT_BRIDGE)..."
|
|
|
|
sudo ovs-vsctl --may-exist add-br "$MGMT_BRIDGE"
|
|
sudo ovs-vsctl set Bridge "$MGMT_BRIDGE" \
|
|
fail-mode=standalone \
|
|
other-config:disable-in-band=true
|
|
sudo ip link set "$MGMT_BRIDGE" up
|
|
echo " $MGMT_BRIDGE: OVS bridge, fail-mode=standalone, up"
|
|
|
|
# Enslave physical/virtual mgmt NIC when provided (multi-node deployments
|
|
# where the node's mgmt subnet spans multiple hosts).
|
|
if [ -n "$MGMT_IFACE" ]; then
|
|
if ! ip link show "$MGMT_IFACE" >/dev/null 2>&1; then
|
|
echo " ERROR: mgmt interface $MGMT_IFACE does not exist"
|
|
ip -o link show | awk -F': ' '{print " " $2}'
|
|
exit 1
|
|
fi
|
|
|
|
# Drop any existing IP on the NIC — IP belongs on the bridge.
|
|
sudo ip addr flush dev "$MGMT_IFACE" || true
|
|
sudo ovs-vsctl --may-exist add-port "$MGMT_BRIDGE" "$MGMT_IFACE"
|
|
sudo ip link set "$MGMT_IFACE" up
|
|
echo " $MGMT_IFACE: port on $MGMT_BRIDGE"
|
|
fi
|
|
|
|
if [ -n "$MGMT_CIDR" ]; then
|
|
sudo ip addr replace "$MGMT_CIDR" dev "$MGMT_BRIDGE"
|
|
echo " $MGMT_BRIDGE: address $MGMT_CIDR"
|
|
|
|
# Persist the IP across reboots via a systemd-networkd drop-in. The
|
|
# OVS bridge definition itself survives in ovsdb; only the L3 IP
|
|
# needs re-applying on boot.
|
|
MGMT_NETD_UNIT="/etc/systemd/network/10-spinifex-mgmt.network"
|
|
sudo tee "$MGMT_NETD_UNIT" >/dev/null <<NETD
|
|
[Match]
|
|
Name=$MGMT_BRIDGE
|
|
|
|
[Network]
|
|
Address=$MGMT_CIDR
|
|
ConfigureWithoutCarrier=yes
|
|
NETD
|
|
echo " wrote $MGMT_NETD_UNIT (IP persists on reboot via systemd-networkd)"
|
|
fi
|
|
fi
|
|
|
|
# --- Step 4: Configure OVN external_ids ---
|
|
echo ""
|
|
echo "Step 4: Setting OVS external_ids for OVN..."
|
|
|
|
if [ -n "$WAN_BRIDGE" ]; then
|
|
BRIDGE_MAPPINGS="external:${WAN_BRIDGE}"
|
|
sudo ovs-vsctl set Open_vSwitch . \
|
|
external_ids:ovn-remote="$OVN_REMOTE" \
|
|
external_ids:ovn-encap-ip="$ENCAP_IP" \
|
|
external_ids:ovn-encap-type="geneve" \
|
|
external_ids:ovn-bridge-mappings="$BRIDGE_MAPPINGS"
|
|
echo " ovn-bridge-mappings: $BRIDGE_MAPPINGS"
|
|
else
|
|
sudo ovs-vsctl set Open_vSwitch . \
|
|
external_ids:ovn-remote="$OVN_REMOTE" \
|
|
external_ids:ovn-encap-ip="$ENCAP_IP" \
|
|
external_ids:ovn-encap-type="geneve"
|
|
fi
|
|
|
|
# Pin OVS system-id (= OVN chassis-id) to NODE_NAME when --node-name was
|
|
# explicitly given. Reasons to pin:
|
|
# 1. IPsec identity: ovs-monitor-ipsec uses chassis-id as the IKEv2
|
|
# `@<name>` peer identity. Our per-node IPsec peer cert
|
|
# (admin.GenerateIPSecPeerCert) carries the cluster node name as CN
|
|
# + dnsName SAN — see spx admin init/join, which take --node NAME and
|
|
# bake NAME into the cert. Leaving chassis-id as the package-generated
|
|
# UUID would cause `received AUTHENTICATION_FAILED` because charon
|
|
# validates `@<UUID>` against a cert dnsName=<NODE_NAME>.
|
|
# 2. Ops legibility: `ovn-sbctl show` lists chassis by name, not UUID.
|
|
#
|
|
# When --node-name is NOT given (CI bootstrap-install.sh today, dev
|
|
# single-node bring-up, ansible roles that don't yet pass it), leave the
|
|
# system-id alone. A hostname fallback used to live here, but on CI
|
|
# single-node it rewrote system-id from the gold-image UUID to a
|
|
# different hostname while the existing SBDB chassis row kept name=UUID;
|
|
# vpcd's discoverChassis then logged "skipping stale local chassis" and
|
|
# refused to start. Preserving the on-disk value is always safe — any
|
|
# caller that needs IPsec cert identity matching pins it themselves.
|
|
if [ -n "$NODE_NAME" ]; then
|
|
echo "$NODE_NAME" | sudo tee /etc/openvswitch/system-id.conf >/dev/null
|
|
sudo ovs-vsctl set Open_vSwitch . external_ids:system-id="$NODE_NAME"
|
|
echo " system-id: $NODE_NAME (pinned via --node-name)"
|
|
else
|
|
CURRENT_ID=$(sudo ovs-vsctl get Open_vSwitch . external_ids:system-id 2>/dev/null | tr -d '"')
|
|
echo " system-id: ${CURRENT_ID:-<unset>} (preserved; no --node-name given)"
|
|
fi
|
|
echo " ovn-remote: $OVN_REMOTE"
|
|
echo " ovn-encap-ip: $ENCAP_IP"
|
|
echo " ovn-encap-type: geneve"
|
|
|
|
# --- Step 5: Start ovn-controller ---
|
|
echo ""
|
|
echo "Step 5: Starting ovn-controller..."
|
|
|
|
# Set ovn-controller file log level to WARN so it doesn't spam the log with
|
|
# connection-retry INFO messages ("OVNSB commit failed") when the SB DB
|
|
# isn't running. Uses a systemd ExecStartPost so it persists across restarts.
|
|
OVN_CTRL_OVERRIDE="/etc/systemd/system/ovn-controller.service.d/log-level.conf"
|
|
sudo mkdir -p "$(dirname "$OVN_CTRL_OVERRIDE")"
|
|
sudo tee "$OVN_CTRL_OVERRIDE" >/dev/null <<'OVERRIDE'
|
|
[Service]
|
|
ExecStartPost=/bin/sh -c 'OVS_RUNDIR=/var/run/ovn exec /usr/bin/ovs-appctl -t ovn-controller vlog/set file:warn'
|
|
OVERRIDE
|
|
sudo systemctl daemon-reload
|
|
echo " ovn-controller log level: file:warn (via systemd drop-in)"
|
|
|
|
sudo systemctl restart ovn-controller
|
|
echo " ovn-controller: started"
|
|
|
|
# Force a full datapath recompute once ovn-controller has connected to the SB.
|
|
# On a fresh single-node RAFT the controller can attach mid-election and program
|
|
# a partial datapath (SNAT ct-commit without output/delivery), then never
|
|
# reconverge. Recomputing after the SB connection is up rebuilds all OpenFlow
|
|
# from the converged Southbound. Compute nodes race a remote SB too, so this
|
|
# runs on every node.
|
|
for i in $(seq 1 30); do
|
|
CTRL_STATUS=$(sudo OVS_RUNDIR=/var/run/ovn ovs-appctl -t ovn-controller \
|
|
connection-status 2>/dev/null)
|
|
if [ "$CTRL_STATUS" = "connected" ]; then
|
|
break
|
|
fi
|
|
echo " Waiting for ovn-controller SB connection... ($i/30)"
|
|
sleep 1
|
|
done
|
|
sudo OVS_RUNDIR=/var/run/ovn ovs-appctl -t ovn-controller inc-engine/recompute \
|
|
2>/dev/null || true
|
|
echo " ovn-controller: forced datapath recompute"
|
|
|
|
# --- Step 6: Sysctl tuning ---
|
|
echo ""
|
|
echo "Step 6: Applying sysctl for overlay networking..."
|
|
|
|
sudo tee /etc/sysctl.d/99-spinifex-vpc.conf >/dev/null <<'SYSCTL'
|
|
# Spinifex VPC networking: enable IP forwarding and disable rp_filter
|
|
# for Geneve overlay traffic on OVS bridges.
|
|
net.ipv4.ip_forward=1
|
|
net.ipv4.conf.all.rp_filter=0
|
|
net.ipv4.conf.default.rp_filter=0
|
|
SYSCTL
|
|
sudo sysctl --system -q
|
|
echo " ip_forward=1, rp_filter=0"
|
|
|
|
# --- Step 6b: Ensure data NIC routing for Geneve tunnels ---
|
|
echo ""
|
|
echo "Step 6b: Configuring data NIC routing for Geneve tunnels..."
|
|
|
|
# When management and data NICs share the same subnet (e.g. both on 10.1.0.0/16),
|
|
# the kernel may route Geneve tunnel traffic through the management NIC with the
|
|
# wrong source IP. This causes remote OVS nodes to drop incoming tunnel packets
|
|
# because the source IP doesn't match the configured tunnel remote_ip.
|
|
# Fix: lower the route metric on the data NIC so it's preferred.
|
|
DATA_IFACE=$(ip -o -4 addr show | awk -v ip="$ENCAP_IP" '$0 ~ ip"/" {print $2}')
|
|
if [ -n "$DATA_IFACE" ]; then
|
|
SUBNET=$(ip -o -4 route show dev "$DATA_IFACE" proto kernel scope link | awk '{print $1}' | head -1)
|
|
if [ -n "$SUBNET" ]; then
|
|
sudo ip route replace "$SUBNET" dev "$DATA_IFACE" src "$ENCAP_IP" metric 50
|
|
echo " data route: $SUBNET via $DATA_IFACE src $ENCAP_IP (metric 50)"
|
|
else
|
|
echo " skipped: no kernel route found for $DATA_IFACE"
|
|
fi
|
|
else
|
|
echo " skipped: could not find interface for $ENCAP_IP"
|
|
fi
|
|
|
|
# --- Step 7: Verify Geneve kernel support ---
|
|
echo ""
|
|
echo "Step 7: Verifying Geneve kernel module..."
|
|
|
|
if sudo modprobe geneve 2>/dev/null; then
|
|
echo " geneve module: loaded"
|
|
else
|
|
echo " WARNING: geneve module not available (tunnels may not work)"
|
|
fi
|
|
|
|
# --- Step 8: Grant the spinifex service users access to OVS/OVN ---
|
|
echo ""
|
|
echo "Step 8: Configuring service-user access..."
|
|
|
|
# Group-scoped, never world. spinifex-daemon and spinifex-vpcd both run with
|
|
# Group=spinifex, so 0660 root:spinifex is exactly the reach they need. A
|
|
# world-writable db.sock hands the local datapath — bridges, ports, ovn-remote —
|
|
# to any account on the box, and a world-writable ctl socket lets any account
|
|
# run `ovn-appctl exit`.
|
|
PERMS_HELPER="/usr/local/lib/spinifex/ovs-socket-perms.sh"
|
|
sudo mkdir -p "$(dirname "$PERMS_HELPER")"
|
|
sudo tee "$PERMS_HELPER" >/dev/null <<'HELPER'
|
|
#!/bin/sh
|
|
# Group-own the OVS/OVN control sockets to `spinifex` so the service users reach
|
|
# them without sudo. Driven from ExecStartPost on both openvswitch-switch and
|
|
# ovn-controller: each recreates its own sockets on start, and the ovn-controller
|
|
# ctl socket name embeds the pid, so it is a new file every time.
|
|
#
|
|
# $1 is an optional glob for the caller's own socket, waited on before the sweep.
|
|
set -eu
|
|
GROUP=spinifex
|
|
WAIT_FOR="${1:-}"
|
|
|
|
if ! getent group "$GROUP" >/dev/null 2>&1; then
|
|
exit 0
|
|
fi
|
|
|
|
# Unquoted so the caller's pattern globs. A caller passing nothing sweeps at once.
|
|
wait_target_present() {
|
|
if [ -z "$WAIT_FOR" ]; then
|
|
return 0
|
|
fi
|
|
for s in $WAIT_FOR; do
|
|
if [ -S "$s" ]; then
|
|
return 0
|
|
fi
|
|
done
|
|
return 1
|
|
}
|
|
|
|
# ExecStartPost can outrun socket creation, so poll briefly rather than miss the
|
|
# socket and leave the health probe unable to read connection-status.
|
|
i=0
|
|
while [ "$i" -lt 25 ]; do
|
|
if wait_target_present; then
|
|
break
|
|
fi
|
|
i=$((i + 1))
|
|
sleep 0.2
|
|
done
|
|
|
|
# The dir must be traversable by the group before the sockets inside it matter.
|
|
# Only the group changes; the owner keeps full access whoever it is.
|
|
if [ -d /var/run/ovn ]; then
|
|
chgrp "$GROUP" /var/run/ovn 2>/dev/null || true
|
|
chmod 0750 /var/run/ovn 2>/dev/null || true
|
|
fi
|
|
|
|
# ovn??_db.sock are the NB/SB databases themselves, which ovn-nbctl and
|
|
# ovn-sbctl connect to. Bridge <name>.mgmt sockets are deliberately NOT here:
|
|
# ovs-vswitchd creates one whenever a bridge appears, including bridges spinifex
|
|
# creates at runtime, so ovs-ofctl keeps its sudo grant.
|
|
for s in /var/run/openvswitch/db.sock /var/run/openvswitch/*.ctl \
|
|
/var/run/ovn/*.ctl /var/run/ovn/ovnnb_db.sock /var/run/ovn/ovnsb_db.sock; do
|
|
if [ -S "$s" ]; then
|
|
chgrp "$GROUP" "$s" 2>/dev/null || true
|
|
chmod 0660 "$s" 2>/dev/null || true
|
|
fi
|
|
done
|
|
|
|
# Group-WRITE on the pidfiles, not just read: `ovn-appctl -t <daemon>` resolves
|
|
# the pid-named ctl socket through the pidfile, and OVS opens it O_RDWR to test
|
|
# the fcntl liveness lock. Read-only fails the probe with EACCES. This also
|
|
# tightens them from the 0644 they ship with.
|
|
for p in /var/run/openvswitch/*.pid /var/run/ovn/*.pid; do
|
|
if [ -f "$p" ]; then
|
|
chgrp "$GROUP" "$p" 2>/dev/null || true
|
|
chmod 0660 "$p" 2>/dev/null || true
|
|
fi
|
|
done
|
|
HELPER
|
|
sudo chmod 0755 "$PERMS_HELPER"
|
|
sudo "$PERMS_HELPER"
|
|
echo " OVS/OVN sockets: 0660 root:spinifex (group-scoped, no world access)"
|
|
|
|
# Persist across restarts of both daemons. Rewritten unconditionally: an existing
|
|
# file is the old 0666 override, and skipping would leave that exposure in place.
|
|
# openvswitch-ipsec is included because Step 10 restarts it after this sweep,
|
|
# so its ctl socket would otherwise be the one file left at the shipped mode.
|
|
for unit in openvswitch-switch:/var/run/openvswitch/db.sock \
|
|
"ovn-controller:/var/run/ovn/*.ctl" \
|
|
"openvswitch-ipsec:/var/run/openvswitch/ovs-monitor-ipsec.*.ctl"; do
|
|
UNIT="${unit%%:*}"
|
|
WAIT_GLOB="${unit#*:}"
|
|
OVERRIDE_DIR="/etc/systemd/system/${UNIT}.service.d"
|
|
sudo mkdir -p "$OVERRIDE_DIR"
|
|
sudo tee "$OVERRIDE_DIR/spinifex-perms.conf" >/dev/null <<OVERRIDE
|
|
[Service]
|
|
ExecStartPost=$PERMS_HELPER "$WAIT_GLOB"
|
|
OVERRIDE
|
|
echo " systemd override: ${UNIT}.service.d/spinifex-perms.conf"
|
|
done
|
|
sudo systemctl daemon-reload
|
|
|
|
# Sudoers rules for spinifex-daemon and spinifex-vpcd are managed by setup.sh
|
|
# (install_sudoers). Skip writing here to avoid conflicts.
|
|
SUDOERS_FILE="/etc/sudoers.d/spinifex-network"
|
|
if [ -f "$SUDOERS_FILE" ]; then
|
|
echo " sudoers rule: already exists ($SUDOERS_FILE, managed by setup.sh)"
|
|
else
|
|
echo " sudoers rule: not found — run setup.sh first, or install manually"
|
|
fi
|
|
|
|
# --- Step 9: Configure OVN log rotation ---
|
|
# The ovn-common package provides /etc/logrotate.d/ovn-common which handles
|
|
# rotation and vlog/reopen. We just add maxsize + rotate to cap disk usage.
|
|
echo ""
|
|
echo "Step 9: Configuring OVN log rotation..."
|
|
|
|
OVN_LOGROTATE="/etc/logrotate.d/ovn-common"
|
|
if [ -f "$OVN_LOGROTATE" ]; then
|
|
if ! grep -q 'maxsize' "$OVN_LOGROTATE"; then
|
|
sudo sed -i '/^\/var\/log\/ovn\/\*\.log {/a\ rotate 5\n maxsize 100M' "$OVN_LOGROTATE"
|
|
echo " added maxsize 100M + rotate 5 to $OVN_LOGROTATE"
|
|
else
|
|
echo " $OVN_LOGROTATE already has maxsize configured"
|
|
fi
|
|
else
|
|
echo " WARNING: $OVN_LOGROTATE not found — install ovn-common package"
|
|
fi
|
|
|
|
# Remove our old custom config if present (superseded by patching ovn-common)
|
|
if [ -f /etc/logrotate.d/ovn-spinifex ]; then
|
|
sudo rm -f /etc/logrotate.d/ovn-spinifex
|
|
echo " removed obsolete /etc/logrotate.d/ovn-spinifex"
|
|
fi
|
|
|
|
# --- Step 10: Enable auto-start on boot ---
|
|
# OVN services should start with the system in production. ovn-controller
|
|
# retries when the SB DB isn't ready; file log level is set to WARN (Step 5)
|
|
# to prevent log spam during those retries.
|
|
echo ""
|
|
echo "Step 10: Enabling OVN auto-start on boot..."
|
|
sudo systemctl enable openvswitch-switch 2>/dev/null || true
|
|
sudo systemctl enable ovn-controller 2>/dev/null || true
|
|
# ovs-monitor-ipsec drives strongSwan from OVS DB cert pointers. The daemon's
|
|
# enableOVNIPSec() flips ipsec_encapsulation=true at runtime and silently drops
|
|
# tunnel traffic if this unit isn't already up — enable at provision time so
|
|
# daemon never needs systemd-write capability (only is-active read).
|
|
sudo systemctl enable openvswitch-ipsec.service 2>/dev/null || true
|
|
# When openvswitch-ipsec is installed before strongswan-starter, the deb
|
|
# post-install starts the service against a missing /usr/sbin/ipsec and
|
|
# leaves it in 'failed' state. Clear the failure and restart unconditionally
|
|
# now that strongswan-starter is present.
|
|
sudo systemctl reset-failed openvswitch-ipsec.service 2>/dev/null || true
|
|
sudo systemctl restart openvswitch-ipsec.service 2>/dev/null || true
|
|
echo " openvswitch-switch: enabled on boot"
|
|
echo " ovn-controller: enabled on boot"
|
|
echo " openvswitch-ipsec: enabled on boot"
|
|
|
|
# --- Step 11: Health check ---
|
|
echo ""
|
|
echo "Step 11: Verifying setup..."
|
|
|
|
OK=true
|
|
|
|
# Check br-int
|
|
if sudo ovs-vsctl br-exists br-int; then
|
|
echo " br-int: OK"
|
|
else
|
|
echo " br-int: FAILED"
|
|
OK=false
|
|
fi
|
|
|
|
# Check WAN bridge (only if configured)
|
|
if [ -n "$WAN_BRIDGE" ]; then
|
|
if sudo ovs-vsctl br-exists "$WAN_BRIDGE"; then
|
|
echo " $WAN_BRIDGE:$(printf '%*s' $((15 - ${#WAN_BRIDGE})) '') OK"
|
|
if [ "$WAN_BRIDGE_MODE" = "veth" ]; then
|
|
if ip link show veth-wan-br >/dev/null 2>&1 && ip link show veth-wan-ovs >/dev/null 2>&1; then
|
|
echo " veth pair: OK (veth-wan-br ↔ veth-wan-ovs)"
|
|
echo " linux bridge: $LINUX_BRIDGE (untouched)"
|
|
else
|
|
echo " veth pair: FAILED (veth-wan-br/veth-wan-ovs not found)"
|
|
OK=false
|
|
fi
|
|
elif [ "$WAN_BRIDGE_MODE" = "direct" ]; then
|
|
if sudo ovs-vsctl port-to-br "$WAN_IFACE" >/dev/null 2>&1; then
|
|
echo " direct bridge: OK ($WAN_IFACE on $WAN_BRIDGE)"
|
|
else
|
|
echo " direct bridge: FAILED ($WAN_IFACE not on $WAN_BRIDGE)"
|
|
OK=false
|
|
fi
|
|
fi
|
|
else
|
|
echo " $WAN_BRIDGE:$(printf '%*s' $((15 - ${#WAN_BRIDGE})) '') FAILED"
|
|
OK=false
|
|
fi
|
|
fi
|
|
|
|
# Check mgmt bridge (only if enabled)
|
|
if [ "$MGMT_BRIDGE_ENABLED" = true ]; then
|
|
if sudo ovs-vsctl br-exists "$MGMT_BRIDGE"; then
|
|
MGMT_IP_ACTUAL=$(ip -4 -o addr show dev "$MGMT_BRIDGE" 2>/dev/null | awk '{print $4}' | head -1)
|
|
echo " $MGMT_BRIDGE:$(printf '%*s' $((15 - ${#MGMT_BRIDGE})) '') OK (${MGMT_IP_ACTUAL:-no IP})"
|
|
else
|
|
echo " $MGMT_BRIDGE:$(printf '%*s' $((15 - ${#MGMT_BRIDGE})) '') FAILED"
|
|
OK=false
|
|
fi
|
|
fi
|
|
|
|
# Check ovn-controller
|
|
if sudo ovs-appctl -t ovn-controller version >/dev/null 2>&1 || systemctl is-active --quiet ovn-controller 2>/dev/null; then
|
|
echo " ovn-controller: OK"
|
|
else
|
|
echo " ovn-controller: FAILED (may still be starting)"
|
|
OK=false
|
|
fi
|
|
|
|
# Check chassis registration (may take a moment)
|
|
if [ "$MANAGEMENT" = true ]; then
|
|
sleep 2
|
|
CHASSIS_COUNT=$(sudo ovn-sbctl show 2>/dev/null | grep -c "Chassis" || true)
|
|
echo " chassis count: $CHASSIS_COUNT"
|
|
fi
|
|
|
|
echo ""
|
|
if [ "$OK" = true ]; then
|
|
echo "=== OVN compute node setup complete ==="
|
|
else
|
|
echo "=== Setup completed with warnings (check above) ==="
|
|
fi
|