mirror of
https://github.com/mulgadc/spinifex.git
synced 2026-10-15 17:11:30 +00:00
v1.22.0
62 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
c6841ce1f0 |
feat(oci): separate using an instance principal from creating one (#1157)
* feat(oci): separate using an instance principal from creating one The allocator needs OCI credentials at runtime, and a node with none forms, passes every health check, then refuses every launch wanting a public address. Instance principal is the credential route that puts no key material on a node, but it needs a dynamic group and a policy, and those are tenancy-root resources the compartment-scoped user the rest of the configuration runs as cannot create. enable_instance_principal conflated the two, so the better credential route was only reachable by a tenancy admin. instance_principal now takes off, adopt or create: adopt selects the credential and creates nothing, because the matching rule covers the whole compartment and so names no instance to reference. setup-identity.sh owns the create case, with its own state. validate-topology.sh destroys its state at the end of every run, so holding tenancy resources there would let a teardown delete the tenancy's policy. Also package install-node.sh and smoke-test.sh, so a cluster can be formed from a curl | bash install with no checkout. smoke-test.sh is not optional: formation scp's it from its own directory for the post-formation verification. * feat(oci): take the credential handoff from an operator hook, and widen the workflow name An API-key deployment needs a credential on each node, and nothing in this repository can supply one: a key in user-data is readable from instance metadata for the life of the instance, and this host runs other people's guests. A manual install does not survive either, because a topology destroys itself on success. So the harness calls an operator-owned executable after formation and before the pool, the only window where a node has /etc/spinifex and has not started the allocator. Instance principal needs no handoff, so the hook is skipped there. The workflow is renamed for the vendors it will cover rather than the first one. Nothing is orphaned in the Actions UI: it has never been on the default branch and has never run, so there is no history attached to the old filename. * docs(oci): the API-key path needs the config file, not just the PEM oci_config_file names an ordinary OCI SDK config and nothing creates it, so a node holding only the key forms and then fails every allocation with no stated cause. * fix(ci): the runner context is not available in a job-level env block A workflow referencing it there is rejected before any job starts, which is why the rename produced a failed run attributed to the push. The reference had never been validated: a dispatch-only workflow that is never dispatched is never parsed. * fix(deps): bump containerd to v2.4.1 for GO-2026-6597 The image-pull DoS via crafted OCI index graph amplification is reachable from the ECS agent's containerd puller, so the vulnerability scan fails preflight on v2.4.0. A patch release with no API change. * fix(e2e): probe guest public addresses from outside the cloud's own network A VCN does not reflect its own public addresses back into itself, so a node asking for one gets nothing however well the datapath works. The workbook driver runs on the first node, so every assertion that curls or SSHes a guest's public address failed on OCI against a cluster that was serving those addresses correctly to the internet. The driver now takes E2E_PUBLIC_PROXY, a SOCKS5 proxy used for public addresses only, and validate-topology.sh supplies one with a remote dynamic forward on the connection that launches the driver. Egress is then the host running the validation, which is outside the VCN and is where a customer sits. Unset leaves every other platform on a direct probe, which is already correct there. Also adds --version TAG for a repeatable install, separates the workflow's auth choice from its external-pool choice so an API key can run with the allocator live, and captures allocator diagnostics before the teardown destroys them. * ci: read the Go version from go.mod in the release workflows Both pinned 1.27.0 by hand while every other workflow reads the file, so the toolchain they build with drifts from the one the module declares the day go.mod moves. release.yml was already inconsistent with itself: its second setup-go step reads spinifex/go.mod. * feat: publish the OCI topology results as tables on the run page A green tick on one job with 4,000 lines of log behind it is confidence for whoever wrote the harness and nothing to anybody else. Someone assessing whether Spinifex works on their cloud should be able to see that it formed and served guests on a single VM, on three VMs and on bare metal without opening a log. record now takes <gate> <status> [detail] and writes results.tsv beside the human block, so a gate's status is a field the script sets rather than a regex over prose that reads fine and matches wrong. record_workbooks turns the driver's own go-test-shaped lines into workbooks.tsv, and runs on the failing branch too: which four passed is most of what the fifth failing means. e2e-oci.sh --summary-only renders both tables to stdout and to GITHUB_STEP_SUMMARY, and the workflow calls it under always() before the sweep, because the sweep destroys the state directories the tables are read from. A skipped gate gets its own mark, and a topology that never ran says so: the one way a results table can do real harm is a reader taking an absent row for a passing one. * docs(oci): cut the deploy-by-hand appendix, and validate the config for real The appendix was 444 of 1014 lines restating an install the Terraform already does, which made the document read as though deploying by hand were a normal route. It is not: the configuration builds the VCN, the volumes and both VNICs per node and renders the cloud-init, in the same order every time. What is genuinely OCI-specific is four things, each of which already has a section, so the replacement names those and sends everyone else to the single-node and multi-node install guides. Verify end to end told the reader to ping a guest's public address from the host, which cannot work: a VCN does not route its own public addresses back into itself. That is the finding this branch is built on and the document was asserting the opposite. It now says where to probe from and why, and carries the allocator's `resolved the external VNIC` check, which existed only in the cut appendix and is the one line proving the credentials and compartment are right. `spx config validate` is not a command -- spx has admin, get, service, top and version -- so that line could only ever fail and its output and status were both discarded. It is replaced by parsing the TOML, which is what was wanted: the remap and the pool append are textual edits, and a broken result would otherwise surface as every service failing to start with nothing saying why. The remap now checks its own substitution count for the same reason, since re.sub with no match rewrites the file unchanged and exits 0. Publication of the run-page tables moves to one owner. GITHUB_STEP_SUMMARY is per step, so appending from the run as well as the publish step would have put two copies of every table on the run page. * fix(oci): check the credential hook before building anything The hook is a path from a CI variable, and whether it exists on the runner is knowable before Terraform runs. Checked where it was used, a wrong path cost the apply, the install and the formation first -- forty minutes and a bare-metal bill to be told a file is missing. Nothing about the check depends on the apply, so it moves to the top, where --dry-run reaches it too. * fix(oci): the summary must say what was built and what was not tested The first CI run headed its tables "Published release `latest channel`" over a build of a feature branch, which is the one error in a results table that would mislead a reader who trusted it. The header now states a tree build as a tree build, and names how the allocator authenticated. A run with no external pool says so in the header rather than leaving it to a SKIPPED row further down. Public-address allocation is the claim a green table is most likely to be read as making, and it is exactly the claim such a run cannot support. Both flags are passed to the publish step too, so the summary rendered after a failure describes the same run as the one that failed. Raise the dev prerelease prune from five to twenty. A pinned dev tag is how an external evaluator installs a specific build, and five is about a week of them -- short enough that the tag someone was handed stops resolving while they are still using it. * docs(oci): the workbook table is a snapshot, and the nightly is the current answer It is dated against a build five releases of work ago, and the nightly now runs the same workbooks on all three topologies and publishes its own table. Say which one to read rather than letting a stale table be taken as current. * ci: rename to e2e-cloudvendor.yml so the sidebar entry is registered from a valid file A workflow's displayed name is captured when GitHub first registers it and is not refreshed afterwards. Both OCI entries were registered from a run that could not be parsed -- a job-level env block referencing runner.temp -- so both list as their path, which reads as a missing name: key and is not one. The 2026-10-02 run was green on all three topologies and the entry still read as a path, with updated_at unchanged from the broken first run, so fixing the file is necessary and not sufficient. A new path is a new registration, and its first run reads a valid file. Dropping -nightly is also more honest: there is no schedule: here, because GitHub registers one only from the default branch, so a cron could never run dev and a feature branch as separate nightlies. * Revert "ci: rename to e2e-cloudvendor.yml so the sidebar entry is registered from a valid file" The rename makes the workflow undispatchable. `gh workflow run` resolves a filename against the default branch, and the raw dispatch endpoint returns 404 for a path GitHub has not registered -- checked twice, several minutes apart, so it is not an indexing delay. The old name works only because it is already registered, and an unrunnable workflow is a worse problem than a mislabelled one. The sidebar label needs a fresh registration, which a rename cannot provide from a feature branch. It corrects itself when the file reaches main, where GitHub re-reads it; the alternative is deleting the dead registrations' runs, which is an operator's call. * fix(ci): never publish the credential hook's output as an artifact The hook is the operator's own executable, and the one thing known about it is that it handles a private key. Its stdout and stderr are captured to credential-hook.log, which the artifact's *.log glob was collecting into a downloadable archive with a fourteen-day retention. Excluded rather than trusted to have been quiet. A hook that prints its key once while someone is debugging it should not thereby publish it. * fix(oci): the hairpin probe measured nothing on one node, and claimed too much With a single host, HOSTS[0] and HOSTS[-1] are the same address, so the node connected to itself -- which always succeeds. It reported "present" on vm-single and bm for that reason and not as a measurement. It now needs two nodes and says so otherwise. The claim it carried was also wrong. "A VCN does not reflect its own public addresses back into itself" was read off a workstation run whose node_client_cidr_allow_list was narrowed to one office address, which makes a node's own public address a non-permitted source: the refusal that follows is identical to an absent hairpin. With the committed 0.0.0.0/0 default the probe reports the hairpin present between two nodes, so the original reading was confounded and is retracted. None of this changes the remedy. A customer reaches a guest from outside the VCN, which is where the proxy's egress is, and probing from there is correct whichever of the two causes is in play -- 15 of 15 workbooks pass through it on all three topologies. What changes is what the documentation may assert: the guide now names both causes as indistinguishable rather than stating one as fact. * docs(oci): a reader could not run the first command, because nothing told them to clone The guide's first code block was `cd scripts/terraform/oci-spx`, into a directory no step had obtained. It also never mentioned the SSH keypair the driver refuses to start without, nor that the configuration is not on main or in v1.21.0 yet, so all three had to be inferred from the deploy failing. Restructured so the deploy comes first and reads as four steps and one command: get the configuration, choose one node or three, write the inputs, run it. The credential decision stays before step 4, because it changes an argument there and a node without one forms, looks healthy, and then refuses every launch that wants a public address. Everything else -- why OCI, sizing, the architecture, the IAM policy, quotas, the oci CLI, what Terraform builds, every variable -- moves under Reference, unchanged in substance. Adds what a successful run prints, naming `allocator ready` as the line to look for: every line above it appears on a node that cannot allocate, and that is the one failure the run does not announce. Also drops an empty verdict.txt committed from a local run. The directory the guide now tells customers to work in should not ship one run's artifacts. |
||
|
|
1743b60246 |
feat: publish a dev channel, so cloud contacts can install dev without a release (#1154)
install.mulgadc.com has served a dev channel since it was written -- setup.sh understands INSTALL_SPINIFEX_CHANNEL=dev and the Worker resolves it to the newest GitHub prerelease -- but nothing ever produced one, so /download/dev/amd64 returned 404. This is the producer. A separate workflow rather than conditionals in release.yml. A dev build is a different artifact, not a release with flags off: amd64 only, no ISO, no system images, no bare-metal gate, and nothing on a self-hosted runner. The sibling repositories are taken at dev rather than their default branch, because dev of spinifex against main of the others is a pairing nobody runs. The tag is the describe string plus -dev, which release.yml's own convention already treats as a prerelease, and which makes the commit recoverable from the version alone. The flag is set at creation and then the published state is asserted: a prerelease must never become the latest release, because latest is what an unqualified curl | bash installs. setup.sh gains --channel and --version so the instruction is a flag rather than an environment variable, and the OCI harness gains OCI_CHANNEL so a nightly can test the path the contacts are actually given. |
||
|
|
7163f7d62d |
feat(oci): run Spinifex on Oracle Cloud, and fix the public-address and NAT gateway lifecycle (#1108)
* feat: ship uninstall-spx.sh and fix the OCI bring-up path
Adds scripts/uninstall-spx.sh, the inverse of setup.sh: it removes the
software where node-reset.sh clears state and leaves the node installed. An
operator who installed with `curl ... | bash` had no teardown path at all.
State teardown is delegated to node-reset.sh rather than reimplemented, and
setup.sh now ships both to /usr/local/share/spinifex so they are reachable
without a checkout.
It refuses on a multi-node cluster and --yes does not override that: a flag
meaning "don't ask me" must not also mean "ignore a safety property".
/var/lib/spinifex and every apt package are kept unless asked for, and both
opt-ins confirm separately even under --yes.
Proved by a full uninstall/reinstall round trip on dev-oci, which found two
bugs neither prod nor dev-prod can reach, because both are ISO-installed:
node-reset.sh exited 2, silently, at its last step and after the wipe.
setup.sh creates the spinifex *group* and the spinifex-* service users but
never a *user* named spinifex, so `getent passwd spinifex` exits 2 and
pipefail carried it into set -e.
The uninstaller broke openvswitch-switch on its first run by removing the
socket-perms helper while leaving the drop-in referencing it, failing the
unit at step EXEC with status 203. Fixed on both sides: the uninstaller
removes drop-ins it wrote into other units' namespaces and restarts anything
it failed, and setup-ovn.sh writes ExecStartPost=- so a missing helper can
never stop another package's daemon.
setup-ovn.sh also learns the shape OCI needs: when --wan-bridge names a Linux
bridge it links it to OVS with a veth pair instead of enslaving the NIC, so
the VNIC keeps its MAC identity and netplan keeps owning the addresses. It
now fails on OVS datapath errors instead of reporting success, and the
--management demotion guard keys on /etc/default/ovn-central rather than on
database presence, which the ovn-central package creates on every node.
Tests: scripts/uninstall-spx_test.sh, wired into make test-build-scripts
along with shellcheck over the four scripts that ship to every node.
* feat: allocate external IPs from the Oracle Cloud API
An OCI VNIC drops any packet whose source is not a registered private IP
object on it, so an external pool cannot be range math there — the address
has to be created through the provider before it exists at all. Add
source = "oci" and the allocator behind it.
One allocation is two OCI objects: a secondary private IP that rides the
wire, and a RESERVED public IP attached to it that the internet reaches.
Allocate returns the public address because that is what AWS semantics are
about, and records the pair so the host plumbing and release path can find
the private half.
The OCI objects are created before the binding is written, and dropped
after it on release — both orders chosen so a crash leaves a discoverable
leak rather than a record that lies. Reconcile squares the two on startup
and is required, not optional: a leaked reserved public IP bills and holds
one of the 50 per-region slots with nothing referencing it. It never
touches an object without our display-name prefix, because the reference
host carries operator-created secondaries on the same VNIC.
Resolve the VNIC from an interface name by MAC through IMDS rather than by
Oracle's VNIC ordering, which is not a documented contract.
Generalise ExternalIPAM.EnableDHCP into InstallAllocator so the OCI wiring
is not a second single-purpose installer.
* fix: refuse source = "oci" outside routed mode, and cover the SDK path
An OCI VNIC accepts exactly one MAC, its own, and delivers every inbound
frame to it regardless of which of its addresses the packet is for.
Measured on the reference host: an internet source reaches 10.200.0.144 as
router-MAC to VNIC-MAC, the public address never appears on the wire at
all, and every off-subnet destination resolves to the same next hop.
Pool mode puts a per-VPC gateway LRP MAC and a per-rule external NAT MAC on
the uplink and ARPs for the address, which policy.go:50 justifies with "the
Linux bridge learns the per-rule external MAC on the veth port like any
other MAC". An OCI VNIC does not learn MACs; it accepts one. So a pool-mode
guest's egress is dropped and its ingress never reaches OVN. Routed mode
keeps the address on the host, which already wears the VNIC's MAC.
Pinning every LRP to that MAC does not rescue pool mode: they share one
external logical switch and OVN resolves inbound frames by an L2 lookup on
it, so duplicate MACs work for one VPC and silently misroute past that.
The refusal names the MAC reason, because a refusal that only says "use nat
mode" reads as arbitrary and gets worked around.
Also test the SDK request shapes against a local endpoint. Two of them are
wrong in ways reading does not catch: pagination stopping early reports a
partial VNIC to reconcile, which then drops live bindings, and a nil
privateIpId on detach is omitted from the body entirely, so OCI reads the
update as a no-op, returns 200, and leaves the address attached and billing.
* fix: install host firewall rules where a distro's catch-all reject cannot precede them
Oracle's Ubuntu cloud image ships a catch-all REJECT in both INPUT and FORWARD.
Two Spinifex datapaths were silently dead behind it on any such host.
EnsureNATEgressRules probed with -C and appended with -A, so its ACCEPT rules
landed after the REJECT and never matched: 24113 packets on the reject, 0 on
both accepts, and guests had no egress. The comment named the case it did not
handle, anticipating a FORWARD policy of DROP — which an append does survive —
rather than an explicit REJECT rule, which it cannot. Insert at the head, and
drain existing copies first, because a rule an earlier build appended still
satisfies -C and would otherwise stay stranded across an upgrade.
Nothing opened INPUT for the IMDS endpoints at all. The responder binds .254
and .253 per instance on the ime- devices, so guest requests are locally
delivered and meet INPUT. Requests arrived and no reply ever left; cloud-init
spent 490s timing out and reported the endpoint as disabled. With one wildcarded
accept the same image boots in 18.6s and finds its datasource.
The natuplink e2e check had the same blind spot the code did, asserting -C and
therefore presence but never position. It now asserts the accepts precede the
first reject.
* feat: OCI address pairs, and an IMDS remap so the host keeps its own metadata
An OCI external address is two objects, not one: a RESERVED public IP that
OCI 1:1-NATs upstream and never puts on the wire, and a secondary private IP
on the VNIC that the wire actually carries. Every AWS-facing record holds the
public half; every datapath object must hold the private one.
The mapping goes in policy.natManager and nowhere else. AddEIP, DeleteEIP,
PruneOrphanEIPs and the HostEIPBinder all converge there, and reconcile
rebuilds the rule set from AWS-facing intent on every pass — so a correctly
mapped rule installed further upstream is swept on the next reconcile and
replaced with one matching an address that never arrives. The seam is a
DatapathResolver defaulting to identity, so every non-OCI deployment is
unchanged. A resolve failure is fatal: falling back to the public address
would install a rule that reads correctly in ovn-nbctl and blackholes.
ocinet.Lookup is the OCI side — read-only, KV-backed, no client and no
credentials, because vpcd is a different process from the daemon that owns
the allocator and the bindings record is all either would consult.
Two live bugs the in-memory test store was hiding, both found by making the
fake report ErrNotFound the way the real store does:
- KVStore.Mutate could not create, so every pool failed its own first
allocation after OCI had already created and billed the pair.
- Reconcile treated a missing record as a failure, aborting the one pass
that exists to find an object created before its binding was written.
Guest IMDS must stay on 169.254.169.254, which is also where a cloud host's
own metadata service lives — the first guest launch made it a local address
and took the host's metadata and DNS with it. The datapath is OpenFlow
steered, so the guest-facing addresses stay put and only the host-side
endpoint address moves, with a PREROUTING DNAT on ime-+ translating and
conntrack un-NATing the reply. Off by default; identity when unset.
The IMDS firewall rules move to vpcd. They are wildcarded over every
endpoint rather than per-launch work, and spinifex-daemon holds no iptables
grant and no CAP_NET_ADMIN by design, so attempting them aborted every
launch.
* fix: name the real constructor in the IMDS bind-address error, and mark the NAT datapath test in-package
The error string pointed at DefaultHostBindAddrs, which does not exist — a
caller following it would have looked for a symbol that was never written.
nat_datapath_test.go reuses nat_test.go's in-package fixtures, so it carries
the //test:in-package marker the package check asks for.
* docs: index what each e2e suite proves
Written because a datapath comment was read as an end-to-end behavioural claim
and the suite that already answered it was found only after the wrong answer
had been given. TestVPCEgressPaths/NATBaseline is the authority on private
subnet egress, and nothing pointed at it.
* fix: source-route an EIP's reply out the VNIC that holds it
An EIP's reply carries the EIP as its source. On a host that pins its
uplink with a policy rule, the reply took the main table instead and left
by the wrong interface — which a cloud VNIC drops, because the address is
registered on a different one. Ingress reached the guest and nothing came
back.
Every bind now mirrors the uplink's rule onto the EIP. The selector is the
rule rather than the interface: both OCI VNICs sit in one subnet, so "the
interface owning the EIP's subnet" names two of them, and two candidate
rules is a refusal rather than a guess. A host with no source routing gets
no rule and no change.
* docs: name the setup-ovn recipe routed mode actually needs on OCI
The OCI guide told operators to run `--wan-bridge=br-wan`, which is
mutually exclusive with `--nat-uplink` and deletes the spx-nat transit
veth routed mode runs on. The node then refuses to bring the uplink up,
with an error naming the flag the guide should have used.
Several messages also claimed routed mode is outbound-only with no
public IPs. That stopped being true when the routed EIP path landed, and
it reads as "what you are about to do cannot work" during the one init
the OCI path documents.
* feat: let routed NAT form a multi-node cluster, and carry every pool through formation
Lifts the --nodes >= 2 refusal on --external-mode=nat. The refusal carried no
technical justification -- it was a v1 scope decision -- but routed NAT is the
only datapath a cloud VNIC can carry, so "routed NAT is single-node" had become
"Spinifex on a cloud host is single-node".
It is not fixed by lifting it. Measured on three OCI nodes: the cluster forms,
all chassis register and guest-to-guest traffic runs at 7.1-7.7 Gbit/s, but
every node claims every EIP, nodes disagree on the VPC's gateway LRP, and only
the gateway chassis reaches its own guests. init now says so on stderr rather
than refusing, because the refusal made the defects unreachable and therefore
unfixable. Distributing the EIP datapath is the actual fix.
Lifting it exposed a second defect that stops formation outright. NetworkConfig
held nine flattened Pool* scalars and the init node set PoolName = "wan"
unconditionally; routed NAT renders two pools and the one that matters --
nat-transit, carrying the gateway-LRP range -- was dropped. Each joiner got a
single pool named "wan" holding the transit gateway and the detected WAN prefix,
and the leader re-rendered its own config from the same struct, so all three
nodes were wrong. Pools is now []admin.PoolData in render order, and PoolData
gains json tags because it is on the wire now rather than a template input.
* feat(install-node): add --external-mode so a cluster can be formed in routed NAT
install-node.sh could not express routed NAT at all. It required
--external-pool/--external-gateway/--external-prefix-len and passed
--external-mode=pool to every spx admin init unconditionally, so the only
supported way to form a routed-NAT cluster was by hand.
--external-mode nat refuses the three pool flags rather than ignoring them, and
threads --nat-uplink into setup-ovn.sh -- without it the WAN interface check
rejects a physical NIC during formation, which is correct in pool mode and
wrong in routed mode, where nothing is bridged.
* fix(ocinet): stop each node deleting its peers' OCI addresses on startup
Reconcile compares the binding record against the private IPs on one VNIC. The
record is one key per pool and therefore cluster-wide, so on more than one node
every peer's binding looks exactly like a binding whose objects OCI has lost.
Each node dropped them, and direction 1 on the owning node then collected the
now-unclaimed objects as leaks -- deleting the reserved public IP and private IP
of a running instance.
Observed on the three-node OCI cluster: node2's startup pass logged "collected a
leaked address" for an address it had allocated ten minutes earlier and "dropped
a stale binding" for one living on node3's VNIC.
The damage did not stop at the OCI objects. With the binding gone,
Lookup.DatapathIP returns the public address unchanged, so the OVN
dnat_and_snat row carries the public address instead of the private half. Guest
egress then leaves the VNIC sourced from a reserved public IP, which OCI drops
because it enforces the registered source per VNIC -- and EnsureEIPSourceRoute
no-ops too, since a public address shares no subnet with any host address. One
destroyed binding takes out both directions.
Binding.VNICID already exists for exactly this ("how a node that comes back from
the dead tells mine from moved on without me") and Reconcile never consulted it.
A binding is now only dropped when it names this node's VNIC; one naming no VNIC
cannot be attributed and is left alone rather than guessed at.
* fix(host): find the EIP's source-routing table when the uplink is held as a /32
uplinkSourceRuleFor identified the interface owning an EIP's subnet by finding
a host address configured with a prefix that contains it. On OCI both VNICs sit
in one subnet, so br-wan has to hold its address as a /32 -- a /23 there puts
the subnet's on-link route in the main table at metric 0 and takes the whole
subnet off the primary VNIC. A /32 contains nothing but itself, so no rule was
ever found, no source rule was installed, and the reply left by the primary
VNIC where OCI dropped it for carrying an unregistered source.
The address is not the only record of who owns the subnet. The rule names a
table, and that table holds the on-link route. Consulted as a fallback, only
when the address prefixes matched nobody, so a host that already resolved this
the direct way keeps its existing answer -- prod and dev-prod are unaffected.
Only scope-link routes count. A default route covers every address and would
make every source-routing table an equally good answer.
* docs(oci): correct the multi-node story and name the oci_vnic_id constraint
The nat-mode warning said EIPs and default egress were both broken on more
than one node. Default egress is fine: delete a guest's dnat_and_snat row and
it reaches 1.1.1.1 in 2.3 ms from a guest on any of three nodes. Only the
public-IP path was broken, and the three defects behind it are now fixed.
What remains is not a bug but the shape of the datapath: routed NAT centralises
the EIP path on the VPC's gateway chassis, ext-shared is a localnet so the other
nodes cannot reach it, and OCI drops any frame whose source is not registered on
the VNIC it leaves by. So every node's pool must pin oci_vnic_id to the gateway
chassis's VNIC rather than resolving its own. Say so in §5.3, where an operator
writing the pool will read it, and in §9, where the cost is that a gateway
change kills every public IP until the pools are repointed.
The single-node cap itself is gone from the doc: a three-node cluster has been
formed and measured, and the warning proceeds rather than refusing.
* feat(nat): distribute the routed-NAT EIP path so it works on more than one node
Routed NAT processed every EIP on the VPC's gateway chassis, and ext-shared is
a localnet, so the transit segment a /32 route pointed into existed only on
that one node. Measured on three nodes: all three claimed all three EIPs, the
nodes disagreed on the gateway LRP, and only guests on the gateway chassis were
reachable.
The mechanism to fix it is not new. Pool mode already distributes EIPs by
putting external_mac and logical_port on the dnat_and_snat row and letting
OVN's ARP responder answer for the external IP on the external segment. Routed
mode has an external segment too, the spx-nat veth pair, and it being per node
is the distribution: only the node running the instance can answer ARP on it.
So a routed rule is now distributed on the same terms as a pool one, and its
host route becomes on-link on the transit veth instead of via a gateway LRP
that may be on another chassis. bindHostEIP stops demanding that address for a
distributed rule, which is what previously failed the bind on every node but
one. vpcd plumbs only the ENIs local OVS reports as its own, asked of OVS
rather than the Southbound DB because the question is about this host.
The gateway LRP keeps its transit-pool address. Default egress routes through
it and works across three nodes today, so making it link-local as pool mode
does would break a working path to fix one distribution has already fixed.
Pool and static are unmoved, and a test asserts that against the same input
rather than leaving it to inspection. A rule with no MAC stays centralised, so
a cluster part-way through an upgrade is never in a state neither shape handles.
Beads: mulga-opyl7, mulga-la0pe
* fix(nat): make routed-EIP host plumbing work on every node
Three guests on three OCI nodes, one guest per node: only one was
reachable. Two defects, both invisible on a single node.
The transit veth took a random MAC per node, but OVN holds one MAC
binding for the transit nexthop across the whole cluster — so every
chassis addressed its egress to whichever node seeded the binding, and
the other kernels dropped it at L2. The pair is node-local, so one
locally-administered address everywhere is unambiguous; setup-ovn.sh
pins it at creation and in the netdev unit, and EnsureUplinkPort repairs
a veth made before that.
Host routes and proxy-ARP also rode the leader-gated reconcile pass, so
a node that never won the lease never plumbed its own guests' EIPs.
BindHostEIPs does that half on its own loop on every node; Bind already
leaves alone an EIP whose ENI is elsewhere, so two nodes never contend.
An unresolvable address skips the sweep rather than shrinking it.
Pool and static are untouched: the new pass is a no-op outside routed
mode, and a test asserts it.
Also adds --teardown and --dry-run to setup-ovn.sh, for re-running it on
a node that is already tangled. It deliberately spares the NB/SB
databases, /etc/spinifex, the system-id and the packages, and refuses to
del-br a Linux bridge.
* fix(nat): assert the transit MAC where vpcd actually runs it
EnsureUplinkPort is never called in production — host.Wiring is
constructed nowhere — so the repair landed in a path the deployed
daemon does not take, and three nodes came back with three different
MACs. vpcd re-asserts it beside the NAT egress rules instead, which is
the routed-NAT branch that does run on every start.
* fix(vpcd): make uplink-mode detection say what it saw, and check it
detectBridgeMode logged only the branch it took, so a node detected as
veth when it was wired for nat looked identical to one that was right.
It now reports both probes every time, errors when a node carries both
uplink veths (set up twice, and --teardown is the way out), and errors
when external_mode and the wiring disagree — the datapath follows the
wiring, so the config silently loses that argument. An explicitly
configured bridge_mode gets the same cross-check, since nothing else
ever compared it against the wiring.
The vpc-networking doc now opens nat with "start with pool unless one
of these applies" and gains a section on nat across more than one node;
the admin warning for --external-mode=nat on two or more nodes says
what was verified by hand and what is still uncovered.
* test(nat): prove routed NAT delivers each node's own guests, on a cluster
natuplink ran single-node only, which is exactly where the two defects
that broke three nodes are invisible. It now admits ModeMultinode, and
phase 9 takes a second shape there: a guest per node in a spread
placement group, and for each one — its public IP plumbed by the node
running it and by no other node, the route on-link with proxy-ARP
answered there, a dnat_and_snat row carrying external_mac and
logical_port, a TCP handshake in from another node, and the guest's own
console verdict for egress. Every node's transit veth is checked
against the one cluster-wide MAC before any guest boots.
Single-node phase 9 gains the same row and on-link assertions, so the
shape is held on both topologies.
Two gates come from what three OCI nodes actually do: every node holds
a gateway_chassis row for every VPC (the active one is the highest
priority) and every node installs the VPC ingress route, so only phase
7 needs gating — it runs where the gateway port and the guest are both
local, and logs which one is missing otherwise.
Cell 20 is real-multi x nat with its own nightly step, leaving the
permutation cells' suite set alone.
* test(nat): run the VPC egress paths in nat mode, not pool mode only
The single suite gated TestVPCEgressPaths and TestWANEgressSMTPBlock on
external_mode = "pool", with a comment saying nat clusters have no
EIP/NAT-GW support. They have had EIPs since the routed path landed, so
the gate now asks whether the cluster can allocate public addresses at
all — pool, or nat with a non-transit pool configured.
The nat-single cell runs TestVPCEgressPaths beside natuplink, which is
the only nightly coverage of a private subnet's isolation and its NAT
gateway in routed mode. natuplink never creates a private subnet.
* docs(config): list nat among external_mode values
* fix(ci): renumber the multi-node nat cell off the bare-metal job
Cell 20 is already the bare-metal single-node job, gated on the same
cells input but declared in the workflow rather than e2e-cells.json.
A matrix entry with the same number runs two unrelated jobs under one
name, and naming 20 in a dispatch selects both.
* feat(images): add Oracle Linux 10.1 and 9.8, and pin their catalog digests
Oracle publishes its qcow2 checksums inline on an HTML page and ships no
sums file, so the four new entries carry the expected digest in the catalog
rather than a URL to fetch one from. Images gains ChecksumDigest for that,
and the catalog import path verifies against it and says which of the two
sources it used, so a recorded digest never reads as a fetched sums file.
Pinning is safe here and only here: each URL names an immutable build
(b291, b293, b178, b182) and never moves. aarch64 has a -kvm-cloud- build
alongside the plain -kvm- one; the cloud build is the cloud-init image and
is the one that matches x86_64's -kvm-.
TestImageCatalogReachable HEADs every URL in the catalog from the general
single-node suite. These artifacts live on hosts nobody here controls, so
an upstream that retires a build breaks `spx admin images import` for a
customer and nothing else in the suite would notice. It also asserts that
every entry sets exactly one checksum source, and that no pinned entry
points at a "latest" URL whose bytes would change under it.
* fix(formation): carry bridge_mode onto the leader and every joiner
applyNetworkConfig copied external_mode, external_interface and the pools
out of the formation NetworkConfig but never bridge_mode, so a multi-node
cluster wrote a spinifex.toml without the key while single-node init wrote
it. Every node then fell back to autodetecting a mode that init had pinned.
Nightly cell 30 caught it: TestNATUplink failed at the config phase on a
spinifex.toml that did not contain bridge_mode = "nat". Deriving it from
the mode rather than adding a NetworkConfig field keeps the leader and the
joiners on the same rule single-node init already uses.
* feat(ui): show how to ssh into an instance, and which user to use
An instance detail page gave the addresses and the key pair name but never
the login user, which is the one part of the command nobody can derive. It
belongs to the AMI, not to Spinifex: nothing in the launch path creates or
renames an account, so stock cloud-init applies the distro's own
default_user. Oracle Linux is cloud-user, Debian is debian, Ubuntu is
ubuntu, and guessing from the distro name gets two of those three wrong.
The card resolves the user from the AMI's name and description, and an
unrecognised image yields a placeholder rather than a guess, because a
wrong username in a copy-paste command is worse than an honest gap. A
private-only instance is called out as reachable from inside the VPC only,
rather than presented as a command that will simply time out.
* fix(nat): plumb host state for a NAT gateway's public address
AddNATGateway installed the OVN snat row and stopped there. On a routed-NAT
node the host is what delivers a public address, so an egressing private guest
left with a source the host held no route back to, and the masquerade rule —
which matches the transit 100.127.0.0/24 alone — never saw the packet. The
gateway's address needs the same /32 route into OVN, proxy-ARP and FORWARD
accepts an EIP gets.
hostBindSpecs unions floatingIPSpecs with one deduped spec per NAT gateway
address and feeds BindHostEIPs. It is kept apart from floatingIPSpecs
deliberately: pruneOrphanEIPs and addLive read that set as the complete list of
addresses allowed to hold a dnat_and_snat, and a gateway holds an snat, so
widening it would stop the sweep reclaiming a stale row on an address later
reused as a gateway's.
AddNATGateway also binds directly, on both the create and idempotent-skip
paths, so a fresh gateway is not dark for up to 30s waiting on the host EIP
pass — and so a reboot that keeps the OVN row still replays the volatile half.
Documents NAT gateways in nat mode in vpc-networking, and says at the head of
that section that nat is a supported mode covered by nightly cells 19 and 30.
* docs(oci): document Oracle Linux as a guest image, and that its user is cloud-user
Four catalog entries, all UEFI. The login user is the one that catches
people: opc is the default on the images Oracle publishes into OCI itself,
while these are the generic KVM cloud images from yum.oracle.com, whose
cloud-init default_user is cloud-user. Verified on 10.1 and 9.8 — opc, oracle
and ec2-user are all refused.
Also records why these four pin a checksum digest inline (Oracle ships no sums
file, and each URL names an immutable build), why arm64 takes the -kvm-cloud-
build, and that SELinux ships enforcing.
* fix(reconcile): stop reading an unreadable intent as an empty one
A wedged JetStream KV returned no keys for the ENI bucket while writes were
still landing. loadPorts mapped that to an empty port map, pruneOrphanPorts
read every guest LSP as an orphan against it, and every guest on the node lost
DHCP and IMDS while the API kept answering and the instances stayed "running".
The existing re-read guard did not help: it re-reads through the same path.
Three defences, because no single one covers every shape of the fault.
A failed kv.Get now fails the pass instead of dropping the record. Dropping one
VPC narrows localVPCs, which filters out every ENI in it, which the sweep reads
as permission to delete every guest port in that VPC — one failed read, same
outcome, and it needs no exotic KV state. Unmarshal failures stay skips: that
is a poison record rather than an unhealthy store, and failing on it would
wedge reconcile forever.
The port sweep now asks local OVS which taps are plugged in here and never
deletes a port that has one. A running guest's port cannot be an orphan
whatever intent says, and OVS is the one liveness signal that does not come
through the KV read path the sweep is otherwise entirely driven by. Wired from
vpcd; unwired callers fall back to the guard below. An unreadable OVS skips the
sweep rather than deciding on intent alone.
Each sweep also refuses outright when the keep set it would delete against
holds nothing at all — no ENIs, no SGs, or no ports and no external IPs. That
is the case local taps cannot cover, because the drift sweep is leader-gated
and lists NB cluster-wide, so the leader holds no tap for another node's guest.
The cost is real: a genuinely orphaned row now survives until one live record
of its class exists. Leaking a stale row is the recoverable half.
Three existing prune tests drove their fixtures to a wholly empty intent, which
is now the refusal case; they keep one live record of the class so they still
prove the prune. The Get-failure path has no unit test — there is no
jetstream.JetStream fake in the tree and an embedded server cannot be made to
list a key it will then refuse.
* docs(oci): separate the two address quotas, and the principal that can read them
The regional reserved-public-IP ceiling is tenancy-wide and does not grow with
node count, so a cluster hits it before the per-VNIC 64, which does. Records
the commands that read both, and that a detached reserved public IP still
bills.
Reading limits or usage needs a tenancy-level grant, which cannot be
compartment-scoped the way the node's policy is. That is a second, read-only
principal kept off every node, not an addition to SpinifexOperators.
* docs(oci): give quotas their own troubleshooting section, and say we enforce none
Spinifex hardcodes no address ceiling: it attempts the allocation and maps
OCI's own refusal to InsufficientAddressCapacity. So a quota is raised with
Oracle and nothing here is reconfigured or restarted — which is what an
operator needs to know before it bites, not after.
Separates the two quotas by how they scale: the regional reserved-public-IP
default is tenancy-wide and raisable by ticket, the per-VNIC 64 is per node and
is not.
* fix(oci): follow a guest to its new node when its EIP moves
OCI delivers a public address to whichever VNIC holds the private IP behind
it, and nothing ever moved that private IP. Binding.VNICID was written once at
allocate time, as the VNIC of whichever queue-group daemon happened to serve
the AWS request, and never updated — so an address landed on the right node
only by chance, and a guest that stopped and started elsewhere went dark while
every OVN row, host route and firewall rule on the new node was correct.
ClaimLocalAddresses closes the gap from the node that should hold the address.
Local OVS decides ownership, the same authority the host EIP binder already
trusts for the same question, and UpdatePrivateIp with a new VnicId does the
move in one server-side call. The private IP OCID survives it, so the reserved
public IP attached to it follows without being touched and the customer's
address never changes.
A loop per node, not leader-gated: the question is about this host's guests,
and a node that never wins the reconcile lease would otherwise never claim the
addresses of the instances it is running.
* fix(oci): record which ENI an EIP is associated with
An EIP is allocated bare and attached by a later AssociateAddress, so the OCI
binding written at allocate time named no ENI and nothing ever filled it in.
The address then stayed on whichever node happened to serve the allocation:
the affinity pass could follow an auto-assigned address, which is allocated
with its ENI, but never an EIP — the case customers actually use.
BindOwner is on an optional OwnerTracker interface rather than Allocator,
because only OCI has a notion of an address being delivered to one node. A
static or DHCP address is on the wire everywhere its node can reach, those
allocators do not implement it, and ExternalIPAM treats a pool that does not
as a success with nothing to do.
The same gap made the release owner guard inert for EIPs: it compares against
a binding ENI that was always empty, so a stale teardown could free an address
already handed to another instance.
* fix(ec2): report the address an instance is actually reachable on
Three faults kept DescribeInstances answering with the address launch assigned,
whatever happened afterwards.
The launch-time stamp lives on the stored ec2.Instance, and the stopped path
only declined to add an address rather than removing one, so a stopped instance
went on advertising an address it had released and that may already belong to
someone else. The projection now clears it, and the NIC association with it,
working on its copy so a restart can still report the address.
The running path filled the public address only when it was nil, which the
stamp never is, so an EIP could not be reported however correctly it was
recorded. The runtime address now wins.
And nothing told the rest of the system about an association: AssociateAddress
wrote neither the ENI record, which is what IMDS and the network reconcile
read, nor the instance record, which is what a describe answers from. The ENI
write is direct; the instance write is a fan-out, because the queue-group
worker that serves AssociateAddress is rarely the node running the instance.
* fix(net): take the host EIP plumbing off a node its guest has left
Bind refuses an EIP whose ENI is on another chassis; the prune beside it kept
anything still wanted cluster-wide. A guest that moved therefore left the old
node holding the /32 route into OVN and the proxy-ARP entry on the uplink, with
nothing that would ever remove them. On a shared segment that node goes on
answering ARP for an address another node is now serving.
The two halves now ask the same question by the same authority, in the loop
that already runs per node. An unreadable local OVS is not a yes: tearing down
a live address on a guess would fire everywhere at once, so it keeps the
binding and the next pass tries again. A binder with no chassis test behaves
exactly as before, and a centralised EIP is exempt because it hairpins through
the gateway chassis and every node plumbs it legitimately.
* fix(net): refuse to free an Elastic IP on behalf of a departing interface
Releasing an instance's public address on teardown releases it by address,
scoped to the ENI holding it. Since an association now writes the EIP onto the
instance record, that address is the EIP — so terminating an instance gave a
customer's Elastic IP back to the pool while describe-addresses still reported
it as theirs, free to be handed to another guest.
The existing ownership guard cannot catch this. It only fires when the stored
allocation already names an ENI, and an EIP is allocated bare and associated
later, so the stored ENI is empty and the guard passes straight through.
The distinction that holds is who is asking. ReleaseAddress is the address's own
owner and names no interface; instance teardown names the interface it is tearing
down. So a release that names an owner may free an auto-assigned address and
never an EIP, which is enforced in each of the three allocators.
DHCP needed the scope carried on the wire, since it releases by address and
resolves the lease afterwards. Absent on an older caller, which reads as false
and keeps the previous behaviour.
Worst on the two providers where it is not recoverable: on DHCP the lease is the
only thing holding the address and the server promises nothing about handing it
back, and on OCI the address is a reserved public IP object that the release
destroys outright.
* test(e2e): prove an Elastic IP survives a stop and start
Instance teardown releases the public address by value, and since the
association writes the EIP onto the instance record, that release aims
straight at the customer's Elastic IP. The allocator guards now refuse it,
but nothing end to end proved the address comes back on a restart.
The step goes inside EIPFlip, which already runs last on the shared public
guest for the same reason a stop is safe there: the address the guest
returns on is the allocation's, not the pool's. It runs on the static
cells and the DHCP ones alike, and on DHCP it doubles as the only outside
view of the lease still renewing while the guest is down.
* feat: release an auto-assigned public address on stop, take a new one on start
AWS lends an instance a public address for as long as it runs and gives it a
different one on the next start. Spinifex kept the address across a stop, which
holds a pool slot for a stopped instance and, on a DHCP pool, keeps renewing a
lease nothing is using.
A stop now offers the address back through the instance cleaner, which refuses
anything an Elastic IP is behind — the EIP association record answers that, the
same question an ENI delete already asks — and records on the VM that the start
owes it a new one. A host drain keeps the address: Restore relaunches the guest
on the next boot, and changing its address under it is an outage nobody asked
for.
The start allocates before the launch, so an exhausted pool refuses the start
rather than booting a guest the customer cannot reach, adopts an Elastic IP
associated while the instance was stopped instead of assigning a second address
beside it, and hands the address back if the launch then fails.
e2e: a StopStartAddress stage on the public guest asserts a stopped instance
reports no address and comes back on a different one from a static pool, and a
StopStartKeepsTheEIP step asserts the opposite for an Elastic IP.
* docs: restructure the OCI guide around two deployment paths, with diagrams
The guide had grown into a numbered wall with no shape: no frontmatter, no
contents, and a reader with an OCI account had no way to tell where to start.
It now follows the multi-node install template — overview, prerequisites, then
the deployment path — and splits that path in two: Terraform for one node or
three, which is the preferred route, and a manual single-node walkthrough for
an instance that already exists. Both meet at one shared configuration section
rather than repeating it.
Two ASCII diagrams carry what the prose could not: one OCI instance with the
whole AWS surface inside it, and three nodes with the same surface distributed,
showing which plane each VNIC carries and how an address follows a guest that
moves.
The limits section was materially out of date and said so in the places that
mattered most. Multi-node is no longer experimental, public addresses are no
longer pinned to one node — each allocates on its own VNIC and the affinity
pass moves the private half to wherever the guest is — and an auto-assigned
address is now returned to OCI on stop, so a stopped fleet stops paying for
addresses. What changed is recorded rather than quietly edited.
The Terraform configuration moves in from the monorepo as
scripts/terraform/oci-spx, so the guide points at something in this repository.
Also marks the two new lifecycle test files in-package, with the reason each
one needs to be: both substitute unexported dependencies.
* docs: rework the OCI guide — SVG diagrams, Terraform variables, iSCSI and br-wan
Replaces the two ASCII diagrams with SVGs in the house style, one for a
single node and one for three. Renames the two deployment sections to
Terraform deployment and Manual deployment, documents what the Terraform
builds per node and every variable worth setting, and explains that the
data volume is an iSCSI attachment rather than a disk.
The manual path now covers the iSCSI login, the fstab entry and the
netplan source routing that Terraform writes, and states what br-wan is
for on a routed-NAT node: it names the VNIC for the OCI allocator and
holds the registered addresses, but is never bridged into OVS.
Opens with what Spinifex is and why OCI is worth running it on.
* fix: make gateway convergence work on a multi-node routed-NAT cluster
Three defects each stopped a multi-node cluster from ever attaching an
internet gateway, and all three produced the same uninformative symptom:
`terraform apply` sitting on `aws_internet_gateway.igw: Still creating...`
forever while every service reported healthy.
ovn-northd was given only its local OVSDB socket as a client connection.
A RAFT follower does not forward writes -- it answers "not cluster leader,
trying another server" -- so with one entry in the list, northd stops
translating Northbound intent into Southbound flows the moment database
leadership moves to another node. Measured on the OCI cluster:
SB_Global.nb_cfg seventeen transactions behind NB_Global.nb_cfg, with no
chassisredirect port for any VPC created after leadership moved.
setup-ovn.sh wrote the member list only when the caller passed
--ovn-remote, which only install-node.sh did; it now derives the list from
the live RAFT membership otherwise, and says so when it finds a single
member, because that node needs a second pass once the others join.
The gateway datapath probe ran wherever the reconcile lease landed rather
than on the chassis owning the port. Both probes leave from the local
uplink, and under routed NAT the transit subnet exists identically on every
node, so a remote probe reported a healthy gateway as dead and aimed a
repair at a datapath the node does not own. GatewayPortLocal gates it.
On OCI the probe then ARPed the tenant-visible public IP, which the cloud
NATs and which appears on no interface anywhere. The reconciler now maps
the address through the same DatapathResolver the NAT rules are built from.
Also adds DescribeVpcEndpoints, which the AWS provider calls on every VPC
delete to sweep GuardDuty-managed endpoints; an InvalidAction there failed
the destroy and stranded the VPC.
The OCI guide gains a Terraform section recording which shipped workbooks
were validated against a three-node OCI cluster and which are still open.
* docs: record the validated Terraform workbook results for the three-node OCI cluster
Six of the seven workbooks run against the OCI cluster pass, including the
three the section exists to prove: RDS, ECS and EKS. Records nginx-alb and the
clean eks-quickstart re-run, and names the two lifecycle gaps that bit during
the run so an operator recognises them rather than reading them as a broken
workbook.
* fix: route the NAT gateway's SNAT source through the datapath resolver
AddNATGateway was the one NAT path that did not map its external address to
the one that rides the wire. Where the public half of an allocation is NAT'd by
the cloud it is on no interface anywhere, so every private-subnet guest egressed
with a source that was dropped, while the gateway reported available and DNS
kept working because the VPC resolver is host-local.
The unmapped address also failed the host EIP sweep, which works in resolved
addresses, so the bind was pruned as foreign on the next pass and reinstalled on
the one after. The public half now survives as an external ID instead.
Also restructures the OCI guide around numbered steps through to running
Terraform, and moves the cloud-init and metadata sections into troubleshooting
where they are read when something is wrong rather than followed when it is not.
* fix: place a NAT gateway's OCI address on the node that forwards for it
OCI drops a packet whose source is not a registered private IP on the VNIC it
leaves from, so a NAT gateway's SNAT source has to be on the gateway chassis.
Two independent placements decided those and nothing reconciled them: the
address was created by whichever worker served AllocateAddress, while the
chassis is a fixed ordering the reconcile pass asserts. On a three-node cluster
that made private-subnet egress a coin flip, and the same Terraform passed or
died depending on which node answered.
The affinity pass already solves this for guests, by asking local OVS where the
tap is. A NAT gateway has no tap, and it skipped anything with no ENI — which
is exactly and only this address. The equivalent local fact is the VPC's
chassisredirect binding, so ownership now has two answers rather than one, and
an address that is neither a guest's nor a gateway's is still left alone.
The VPC is recorded from the reconcile pass rather than from CreateNatGateway,
because the answer is the gateway chassis and reconcile is what decides it.
* fix: plumb a NAT gateway's host ingress only on its gateway chassis
A NAT gateway's address has no ENI, so neither the bind's locality test nor
the prune's could ever fire for it and every node installed its /32 route into
OVN. Latent on bare metal, where pool addresses are disjoint from the node
subnet; on a cloud that hands out the address from the nodes' own subnet it
outranks the connected route and swallows node-to-node traffic.
Give that address the same second authority the ocinet affinity pass has: the
VPC's chassisredirect binding, read from the local ovn-controller. An
unanswerable question still leaves the binding alone, so a single node whose
gateway port is not yet claimed behaves exactly as before.
The orphan EIP prune built its live set from ENI and user EIPs alone while also
sweeping host ingress, so every drift pass tore down the ingress of every live
NAT gateway and left it dark until the next host EIP tick.
* fix: ask the gateway chassis only about a NAT gateway's address
gatewayElsewhere skipped the NAT gateway marker it was named for and answered
for every spec, so on a node that is not the VPC's gateway chassis every EIP —
including a guest's, whose locality is its own port — was left unplumbed. Two
of three nodes bound nothing.
* test: assert the two private-subnet EKS workbooks in the tofu harness
eks-https-ingress and eks-gitops-argocd put their workers in private subnets
behind a NAT gateway, so a worker only registers Ready if its egress to the
cluster endpoint and to ECR survives that path. That makes them the workbooks
that catch a NAT gateway fault, and neither had an assertion, so neither could
be run at all — run_workbook calls assert_<name> by construction.
Both share eks-quickstart's readiness check, extracted unchanged. They also
name the worker size node_instance_type rather than instance_type, and tofu
rejects a -var for an undeclared variable outright, so the name is read from
the config instead of kept in a list here.
* test: count agents, not every node, when asserting EKS workers Ready
The control plane is three K3s servers, so an unfiltered node count reaches a
one-worker cluster's desired size before any worker joins — the assertion
passed on exactly the failure it exists to catch, reporting "4/1 workers
Ready". Filtering on the control-plane role label makes it 1/1, which is the
number that says a node-group worker registered.
Matters most for the two private-subnet workbooks, where the worker joining is
the whole proof that egress through the NAT gateway works.
* docs: record the two private-subnet EKS workbooks passing on OCI
|
||
|
|
d65c4f3673 |
fix: family-qualify unscoped firewall accepts to IPv4 (#999)
The public, formation and DNS accept rules carried no address family, so on a node that autoconfigures a global IPv6 from an upstream Router Advertisement they served the console, predastore S3 gate, AWS gateway and DNS on that public address with none of the source scoping applied on IPv4. Qualify them with meta nfproto ipv4 so v6 falls to the default drop; the scoped rules are already v4-only via ip saddr. |
||
|
|
828b5df4aa |
fix: pause a guest on a backend I/O error instead of handing it EIO (#977)
* fix: fail DRAIN when a volume seal failed
shutdownAndUnmount logged the volume unmount error and returned nothing, so
StopAll returned nil and the DRAIN phase ACKed success with vms_stopped set.
The coordinator then advanced to STORAGE and stopped viperblock while the seal
was still in flight, tearing the VBState envelope and leaving the guest unable
to mount its root volume on the next boot. The deploy reported success.
shutdownAndUnmount now returns ErrVolumeSealFailed when the unmount did not
seal; QMP, PID-file, fw_cfg and telemetry cleanup stay best-effort. stopCleanup
and stopOne carry it without aborting the rest of the teardown, since QEMU is
already down by then, and StopAll aggregates the per-VM failures so
handleShutdownDrain ACKs with Error set and never reports vms_stopped.
volumeMounterAdapter.Unmount was the second swallow site: it logged each failed
seal and returned nil unconditionally. It now attempts every volume and returns
the aggregate, which is what the VolumeMounter contract already described.
Terminate still tolerates a failed seal — the volumes are deleted next, so an
unsealed block map loses nothing a caller can ask for.
This does not fix the seal itself. It converts silent data loss into a refused
upgrade that an operator can act on.
* test: add the storagefault e2e suite for backend-outage guest survival
Freezes predastore with SIGSTOP to hold connections open while answering
nothing, which is the fault a timeout-free path cannot distinguish from a
slow peer. On one node that is a total outage; on three it freezes every
node but the guest's own, breaking the RS(2,1) shard floor.
The suite writes and flushes a verifiable region before the fault and
churns a separate unverified region during it, so an interrupted write is
never mistaken for lost data. The root-filesystem load runs from the
user's home rather than /tmp, which is tmpfs on this image and would move
no bytes on the root device.
* test: verify the root device is under write pressure, and size the outage
The previous guard matched /^ *vda / against /proc/diskstats, where the
device name is the third field, and read $7 which is ms_reading rather
than sectors_written. It printed empty and asserted nothing, so a green
run could not distinguish a surviving guest from an idle disk. It now
samples sectors_written twice and fails unless it advances.
The outage is sized from viperblock's absorption rather than guessed:
a workload must fill DefaultMaxPendingBytes before backpressure engages
at all, so a short freeze measures the retry budget rather than the fault.
* test: add nbdkit fault injection to the storage-fault e2e suite
The predastore freeze takes the whole storage cluster away from every
guest on it, which is too broad to run beside anything else. Removing a
single volume's NBD server is the same fault at one-volume scope: one
host, one guest, nothing cluster-wide stopped.
Both signals are here because they sit on opposite sides of the defect.
SIGSTOP holds the socket open and answers nothing, so the guest blocks
and no error reaches ext4. SIGKILL closes it, and QEMU's nbd driver at
the default reconnect-delay of 0 fails requests at once, which under
werror=report aborts the journal.
Signalling is guarded: a pid is matched on comm, our plugin and the
volume argument together, and re-confirmed immediately before the
signal, because these hosts run nbdkit for other volumes and pids are
reused.
* fix: pause a guest on a backend I/O error instead of handing it EIO
Every virtio-blk device was created with werror=report,rerror=report, so a
backend outage was delivered to the guest as EIO. ext4 aborts its journal on
that and remounts read-only, and the write that failed is simply gone. Under
werror=stop QEMU pauses the VM and holds the failed request, so a backend that
comes back resumes the guest with nothing lost.
The boot drive, the cold-boot data volume and the hot-plugged data volume all
move to stop. Alongside it the NBD transport gets reconnect-delay=30, which
pauses requests rather than failing them while a storage process restarts on
the same socket; on the legacy -drive form it has to be file.reconnect-delay,
because the bare name reaches the raw format driver, which has no such option.
The QMP heartbeat now recognises run state io-error and issues cont. After ten
attempts the instance is reported impaired and the cadence drops to one attempt
per ten heartbeats, but it never stops: QEMU holds the request for as long as
the guest exists, so a backend that returns an hour later can still be resumed.
The storagefault suite gains the fault this was written for — kill the volume's
own nbdkit, hold, then put it back on the same socket — and it now verifies a
sha256 region across the outage rather than trusting the guest to be reachable.
Three harness defects went with it: the socket-liveness poll ran unprivileged
against a 0770 directory and could never succeed, the relaunched socket was
left 0755 where QEMU needs group write, and the two variants shared one guest
so a fault in the first was diagnosed in the second.
* test: cover the io-error resume policy
* test: stop two parallel tests racing on the terminate backoff variable
* fix: report a guest paused on a backend I/O error as impaired
A guest held by werror=stop kept reporting ok on both status checks. QMP stays
responsive while the guest is paused -- cont is being sent and answered -- so
the QMP failure gate that DescribeInstanceStatus keys on never trips, and the
one state a customer most needs to see looked healthy.
Instance status now reports impaired/failed while the resume budget is
non-zero, timestamped from IOErrorSince so impairedSince is when the guest
paused rather than when it was escalated. System status reports impaired too:
a backend I/O error is an infrastructure fault, not a guest one, and that
distinction is what the two checks exist to draw. The counter is cleared by
the first poll that sees the guest running, so both clear on recovery.
* test: reap the relaunched nbdkit when the fault test ends
relaunchNbdkit detaches the server with setsid so it outlives the SSH session
that started it, and viperblockd never learned it exists. Nothing reaped it, so
every run left an nbdkit holding a socket and a cache for a volume that was
later detached or deleted -- four were found running on dev-prod against two
detached and two deleted volumes.
The PID is resolved from the socket path rather than the volume id, so a
legitimate viperblockd server for the same volume is never the one killed.
* test: prove the backend is serving before a fault is called cleared
Thawing the process a fault stopped is not the same as restoring the service.
The outage test treated SIGCONT as the end of the fault and went straight to
judging the guest, so it passed while the cluster it ran on stayed unable to
serve a single object for the next 35 minutes, and the next test would have
inherited that.
thawPredastore now puts and gets an object through every gate, with a budget,
and fails the test if the backend does not come back.
* fix: do not hand back a mount entry whose export is gone
A volume whose unmount failed kept its entry in MountedVolumes while its nbdkit
was gone. Every later ebs.mount then matched that entry and returned its socket
path, so vmMgr waited for a socket nothing would ever create and the instance
could not be started again — on dev-prod a guest stopped against a frozen
backend was left permanently stopped, four start attempts failing identically
on a socket the node had already removed.
Drop the entry when there is positive evidence the export is dead: the socket
is absent, or the recorded pid is not running. Neither can be true of a live
export, so the double-writer hazard the guard exists to prevent is unaffected.
Also make the durability test's pattern helpers report failures. The read dd sat
in a pipeline, so its exit status was discarded and the harness hashed nothing
and returned the empty-string sha256 as a checksum.
* test: report the guest console when a restart never answers SSH
A restart that reaches running but never comes back is indistinguishable from
a dead root filesystem without the serial console, and the log is gone once
the fixture terminates the instance.
* fix: converge guest port datapaths concurrently, not one deadline after another
Each guest port that misses its SB binding burns the full convergence deadline,
and applyEIPs spent them in series. Three ports belonging to long-stopped
instances therefore held a newly launched guest's EIP dark for the sum of them
before its own probe started.
AddEIP stays serial since it mutates NB. Only the waits fan out, bounded, and
sb-cluster-state-reset is now serialised with a minimum interval so concurrent
probes cannot each fire a cluster-wide resync.
* fix: refuse a stale cross-node start after the owning node is gone
The volume lease already refused a cross-node mount, but it is a liveness
claim: 45s TTL, renewed every 15s. A node that dies holding un-uploaded
writes stops renewing, and 45 seconds later nothing refuses a start elsewhere
that loads a stale backend checkpoint.
A failed seal now writes a durable marker naming the node holding the only
current copy, cleared on a seal that reaches the backend and on delete. The
lease covers a live holder, the marker a dead one.
The refusal also reaches the caller instead of being flattened to
ServerInternal, which told an operator to retry something that cannot succeed
while the holder is down.
* fix: keep the daemon's message when a start is refused
Rebuilding the error from the code alone rendered the generic ErrorLookup
text, so a refusal naming the node holding the volume reached the caller as
boilerplate about attaching volumes.
* fix(ec2): terminate detaches every DeleteOnTermination=false volume
TerminateStoppedInstance skipped the detach for a non-Boot DoT=false volume
on the assumption that Stop's Unmount had already cleared its attachment.
Unmount only clears it when the seal succeeded, so a volume whose seal failed
stayed in-use pointing at an instance that terminate then deleted, leaving it
unreachable with no owner to release it.
The running-instance path already detaches every DoT=false volume; the stopped
path now matches it, and tolerates an already-gone volume the same way.
DeleteVolume also keeps its provider error on the way out. The terminate reaper
retries the delete every two minutes and logged a bare ServerInternal, which
made a blob node being down indistinguishable from a transient fault.
* fix(ec2): DetachVolume --force releases a volume whose instance is gone
The ordinary detach routes to ec2.cmd.{instanceID} for the guest unplug, so a
volume left attached by a part-way teardown could never be detached: the
instance no longer runs anywhere and nothing answers. That also made it
undeletable, since DeleteVolume refuses an attached volume.
ForceDetachVolume already existed for this deadlock but was reachable only from
account teardown. Force now falls back to it when the instance has no responder,
which is the one case where clearing the attachment cannot strand a live guest.
* fix(viperblock): unsealed writes steer placement instead of pinning a volume
The dirty marker refused any mount from a node other than the one holding
unsealed writes. Instance start already forwards to the node that last ran the
instance and falls back after a 30s window, so that refusal turned a working
fallback into a volume that could run nowhere once its owner was gone. It
traded a rare data-loss risk for a permanent availability failure.
The marker is now a record and a warning, not a gate. A takeover logs the
previous holder and why it could not seal, then adopts the marker so the old
node is no longer treated as the better source. Live exclusion is unchanged and
still enforced by the lease.
It is also written on open rather than on seal failure. A node killed mid-write
never reaches its seal, so the old trigger left no trace in exactly the case the
marker exists to describe.
Adds 'spx admin volumes unsealed' to see which volumes would cost something if
started elsewhere.
* fix(viperblock): fence a volume whose lease moved instead of logging it
The lease was checked once, at mount, and never again. A node that lost it
kept its export up and kept writing into a volume another node owned, so
both copies advanced and the backend settled it by arrival order.
Losing a renewal now decides: another holder means tear the export down,
no holder means the entry merely aged out, so reclaim it and leave the
guest running. Fencing never seals — this node's copy is the stale one —
and leaves the dirty marker for the winner to take over.
This is not an epoch fence. It narrows the window from the 45s TTL to one
renewal interval at no write-path cost; the backend still cannot refuse a
stale writer.
* fix(network): advertise EIPs so a recycled address is reachable
The gateway switch port only asked ovn-northd to publish the router's NAT
addresses in centralised and routed modes, so on a distributed cluster nothing
ever announced an elastic IP. OVN still answers ARP for it, which is why a
first-time allocation works and hid this — but no gratuitous ARP is sent when
the address moves to a new ENI, so every host on the segment keeps resolving it
to the previous holder's MAC until its cache ages out. Reusing an address from
the pool then lands on a dead MAC and the instance is unreachable from outside.
Distributed mode needs the option as much as the others: northd scopes each
entry with is_chassis_resident(<vif port>), so the announcement leaves from the
chassis running the instance rather than the gateway, which is what distributed
NAT wants.
Converge on the already-attached path too. AttachIGW returns early once the
gateway port exists and nothing else rewrites it, so without that an existing
VPC would stay silent for its whole life.
Confirmed on dev-prod: setting the option moved three EIPs from unadvertised to
carrying their correct external_mac, each scoped to its own ENI's port.
* fix(viperblock): make the volume fence and its dirty marker ownership-safe
Four corrections to the lease-loss fence, all found in review.
Drop the reacquire path. Losing a lease and finding no successor was treated as
a lapsed entry worth reclaiming, but leases.acquire returns the cached entry —
already flagged lost, with a dead renewal goroutine — so the "reclaimed" lease
renewed nothing and the node went on writing a volume it could not prove it
owned. The two errors are not symmetric: a false fence costs one guest a
restart, a false reclaim leaves two nodes writing one volume. Fence in both
cases, and report which happened through the outcome attribute.
Surrender a lease this node cannot confirm. Renewal only noticed a loss when
the server rejected an update, so a node partitioned from NATS kept its export
up while the TTL expired and another node took the volume. Track the last
confirmed renewal and give the volume up once that ages past the point where
the server may admit another owner. Bound the renewal call too, so a hung
JetStream request cannot hold the goroutine past that point.
Do not act on a kill that did not take. Both the fence and ebs.unmount removed
the mount entry, released the lease and announced the result before knowing
nbdkit had exited — the fence then reported a writer stopped that was still
running, and the unmount sealed into a directory a live process was writing.
Wait for the exit, and on failure leave the volume mounted and say so. An
already-exited process now counts as success, which is what the caller asked.
Give the dirty marker a generation. It recorded an owner and nothing to order
two nodes' claims, so a node returning after a takeover could clear or overwrite
the winner's marker and point placement back at the stale copy. Stamp the lease
generation, refuse a write from an older one, and only clear a marker this node
still owns. A marker that cannot be written now fails the open rather than
leaving writes nothing records.
* test(viperblock): cover the stall surrender and the unmount kill guard
The two ownership cases the fence work left untested.
A holder partitioned from NATS while the winner keeps it never gets an update
rejected, so revision checking cannot see it — it has to give the volume up on
its own clock. Pins that validity sits below the server TTL with room for a
check in between, that a lapsed holder reports the loss as a stall rather than
as a takeover, and that releasing a surrendered lease leaves the entry for
whoever holds it now.
The unmount side of the kill guard: sealing under a live nbdkit writes a state
torn between two writers, so a kill that did not take has to fail the unmount
and leave the entry mounted for a retry.
* fix(e2e): keep the guest private key for as long as the key pair
EnsureKeyPair computed the PEM path from the caller's directory but wrote
the file inside the ensureOnce closure, which runs only on the first call.
Callers passed a per-test artifact dir, and ArtifactDir removes that dir
when the test passes — so the first test's success deleted the only copy
of the private key while the key pair stayed registered, and every later
call returned a path nothing had ever been written to.
Guests after the first were then launched against a public key whose
private half no longer existed, so the harness could never authenticate
and gave up after the full five-minute budget. The guests were healthy
and reachable on tcp/22 throughout, which is why this read as a storage
or network fault for so long.
The directory parameter was the defect, so it is gone: the PEM now lives
in a directory the fixture owns and removes with the key pair, and no
caller can supply one that is shorter-lived.
Also reorder the killed-nbdkit teardown. The reaper registered its own
cleanup after the detach registered one, so LIFO killed the block server
before the platform detached the disk and DetachVolume then failed with
"Node ... is in use". The detach cleanup now reaps once it is done.
* fix: stop leaking an nbdkit export when recovery cannot adopt it
Restart recovery adopts a guest's boot volume, then routinely fails the
-efi volume with "claim lease: context deadline exceeded" -- JetStream is
still catching up at daemon start and the KV claim runs on the client's
5s default. Recovery gave up on the first error and never retried, so the
export stayed live with no registry entry. At terminate the unmount found
nothing to seal, returned NotFound and killed nothing, and the process
outlived its guest holding the volume and socket open. EFI is always the
second volume adopted, which is why it was always the one that leaked.
Two changes, because either alone leaves a hole:
- rebuildMountedVolume retries the build (4 attempts, 3s apart) so a
JetStream that is merely slow no longer orphans an export for the life
of the process.
- unmountVolume reaps a corroborated export for the volume it was asked
to unmount when the registry has no entry for it, so an export orphaned
by any means is still cleaned up. The reap goes through
reapOrphanedNbdkit, which declines anything a live process references:
at unmount the guest's blockdev may not be torn down yet, and killing
the server underneath it strands QEMU.
* test: hold the backend-serving probe and assert predastore readiness
The backend-outage test declared the backend restored on one successful
round trip through each gate. A gate can answer the request that arrives
just after a thaw and then lose its blob peers under the load that
follows, which is a backend that never recovered reported as one that did
-- and that is what happened: the probe reported all three gates serving
minutes before the guest was still taking BLOCK_IO_ERROR on every resume.
The round trip has to hold across three rounds now, and the count restarts
rather than decays when one fails, so a gate that serves and then stops is
the failure the hold is looking for rather than noise it averages out.
It also checks /readyz on each host and reports any failed check by name.
The round trip only proves this workstation can write through a gate; it
says nothing about which blob peers that gate can reach, and a gate one
node short of the write floor serves a small object and fails a guest. A
host that serves no admin listener is logged and skipped, since the port
is optional configuration.
* fix: scope predastore's admin port to the cluster plane in the host policy
predastore's admin listener binds the host's cluster bind_addr and serves
/healthz and /readyz unauthenticated. Readiness now names which blob peers
a gate cannot reach, which is exactly the kind of topology detail 4432 is
peer-scoped for, so 8660 joins it in the peer-scoped rule rather than the
public one.
* fix: keep resuming a paused guest at heartbeat rate after a long outage
Past ten attempts the cont dropped to one per ten heartbeats, so a guest
whose backend had come back could sit paused for another five minutes
before anything retried it. Measured on dev-prod: the backend was proved
serving through all three gates while the guest was still waiting on
attempt 60, five minutes after attempt 50.
The slowdown was there to avoid paying a failed I/O every thirty seconds
on a backend still down. That is nearly free, and five minutes of downtime
after recovery is not, so only the log line is throttled now.
* test: fail the run when a key pair name resolves to more than one pair
A create that lands twice leaves two key pairs with one name and different
material. RunInstances resolves the name to one of them while the harness
holds the private key of the other, and the only symptom is every guest in
the run refusing the key at the SSH gate — five minutes of waiting per
guest, four guests, and nothing anywhere naming the cause. Observed on
dev-prod: two pairs created a millisecond apart, both named
e2e-key-30de10ba.
One DescribeKeyPairs after the create says so outright instead.
* test: tolerate an already-released volume in the detach teardown
Teardown runs DetachVolumeWait after a terminate that releases the volume
itself, so the detach can arrive at a volume already on its way to
available. That is the outcome it wanted, and treating the IncorrectState
refusal as fatal failed a backend-outage run whose assertions had all
passed — the guest came back, every acknowledged write verified, and the
test still went red on the way out.
VolumeInUse is still fatal: that one means the volume is attached
somewhere it should not be.
* test: carry the merged suites onto the reworked key-pair and account-scoped seams
The diskperf suite arrived on dev calling EnsureKeyPair with the artifact dir
this branch removed, and DeleteVolume's metadata lookup is account-scoped now,
so the provider-failure test has to seed and delete under the same account.
* refactor: make the fence outcome a type in one const block
Four separate exported string constants with a paragraph of comment each,
passed to RecordVolumeFence as a bare string. Group them, give them a
FenceOutcome type, and take that type at both call sites so an arbitrary
value can no longer reach the metric attribute.
* refactor: move viperblockd's wire contract into a leaf vbwire package
The daemon imported viperblockd for exactly two symbols -- the fenced
volume subject and its event -- which put the storage service back on the
daemon's dependency graph to name something it only listens for.
vbwire holds the contract instead: the subject and event, the dirty
bucket name and record shape, and the read-only listing an operator tool
needs. It imports nothing from spinifex, so both the daemon and the admin
CLI drop their edge to viperblockd entirely. cmd/service.go keeps its
one, which is genuine: it constructs the service.
* docs: drop a specific host name from the start-refusal comment
Named a real dev-prod host in a comment and in test fixtures. Say what
the name is instead.
* ci: give storagefault a dedicated nightly cell
The suite is eligible for both topologies and runs on the PR gate, but no
nightly cell ran it: the permutation cells run a deliberately narrow
subset and none of the dedicated suite cells named it.
Cell 29, single-node, following eks/ecs/rds. It cannot join a permutation
cell -- it SIGSTOPs a cluster-wide service, so every suite sharing that
environment would report the outage as its own failure.
* ci: run storagefault nightly on three nodes, not one
The previous commit put its dedicated cell on a single-node runner. That was
the wrong topology and the wrong justification: single-node is RS(1,0), where
the shard floor cannot be broken and a cross-node takeover after a failed seal
does not exist, so the two assertions worth having a dedicated cell for were
the two it could not make. Cell 29 is now real-multi on ci-multi.
It also corrects the claim that the PR gate already covers the multi-node case.
The suite is eligible for both topologies, but e2e.yml's default suite list
never names it, so it has never run there. A full pass is ~63 minutes on
dev-prod bare metal, almost all of it deliberate waiting -- one test holds
predastore SIGSTOPped for seven minutes -- which is too long to add to a gate
that currently finishes well inside its budget. Nightly is where it belongs.
Consequences: a per-cell timeout_minutes, defaulting to the previous 50, since
90 minutes of suite cannot run in a 50-minute job; the permutation steps gated
on matrix.suite == '' so the dedicated cells do not also run them; and a Run
Multi Suite E2E step that builds NODES_CSV from the tofu inventory and asserts
the suite against E2E_SUITES_MULTI before running it.
* fix: stop a startup KV race leaving vpcd serving keyless guests
vpcd opens five KV buckets while NATS is still coming up, each attempt
carrying a ~5s JetStream API deadline, and applied three different policies to
the same failure: spinifex-vpc-enis was fatal, while instance-state,
security-groups, subnets and vpcs each degraded silently for the lifetime of
the process. A five-second blip during a cold start therefore decided how a
node served metadata until someone restarted it.
On dev-prod all three nodes hit this after a deploy. Two were saved by
accident: their ENI bucket also timed out, so they exited 1 and systemd
restarted them cleanly. The third's ENI bucket opened in time, so it never
crashed and ran for hours with no instance record loader. With the local state
file unreadable as well, every instance-backed IMDS leaf 404'd, cloud-init's
crawl died on ami-id and fell back to DataSourceNone, and every guest launched
on that node booted with no authorized_keys.
kvstore.OpenWithRetry retries for a bounded window before any policy applies,
logs the cause per attempt and the wait on a late success, wraps the last error
with the bucket name, and returns at once on a cancelled context. All five
opens use it. Failing to open the instance record space is now fatal, matching
the ENI bucket: the dependency whose loss stops guests logging in should not be
treated more leniently than the one whose loss stops ENI resolution.
Also fixes the reason the fallback was load bearing at all. The local state
file was written 0600 and vpcd reads it as a different user in the shared
spinifex group, so the local-first path had never once worked and its
mtime+size cache had never fired. It is 0640 now, set with an explicit Chmod so
an inherited umask cannot undo it.
Closes mulga-gtpzz, mulga-dhqxr. Still open: mulga-mm2oc, IMDS serving an
unresolvable instance as "no key pair" with nothing logged.
* fix: scope the ime-* firewall accept to IMDS and VPC DNS only
The per-tap OVS demux delivers any guest packet addressed to
169.254.169.254 or .253 onto an ime-* host port regardless of L4 port,
and iifname "ime-*" accept then admitted all of it. Every wildcard-bound
host service — sshd, the AWS gateway, northstar, the console — answered
guest packets on those addresses; only asymmetric reply routing kept the
handshake from completing, and a guest could still drive northstar to
recurse unthrottled. Scope the accept to IMDS (.254:80) and VPC DNS
(.253:53), letting everything else fall through to policy drop.
* docs: document the instance-to-host plane and how to protect it without the ISO
The metadata/VPC-DNS link-local plane (169.254.169.254/.253) is served by
host services and is invisible to a NIC-level or cloud firewall, since the
traffic is intra-host on the OVS bridge. Explain that the ISO ships the
scoping rule armed, that the binary installer ships the firewall off, and
that a non-ISO install must enable it with setup.sh --firewall=on or
firewall_enabled=true. Include verification from an instance and the host.
* fix: withhold the IMDS meta-data listing when the instance does not resolve
Every omission from the meta-data root is a positive claim about the instance —
public-keys/ absent means "launched without a key pair", and cloud-init believes
it, writes no authorized_keys and boots the guest keyless. So resolving the
instance was best-effort for a listing whose whole meaning depends on it: a
backend error or a miss shortened the listing instead of failing it, and nothing
anywhere recorded that the answer was a guess.
Withhold the listing with a 500 instead. cloud-init retries a 5xx and cannot
retry a 200 that is merely wrong, so this converts a permanent silent failure
into a transient loud one. servePublicKeys already had this policy for the leaf;
the root is what contradicted it.
A profile lookup that fails still serves the listing minus iam/, and now logs.
The key pair is the field a guest cannot recover from losing, while a missing
role surfaces through the credentials leaf, which reports the miss itself.
Also stops the storagefault cross-node test failing on its own access path. It
tolerates the pattern changing across a takeover, but readPattern needs sudo,
and a volume opened from the backend checkpoint may predate cloud-init writing
its sudoers drop-in — indistinguishable from an unreadable device at the dd call
site. It now checks sudo first, and reads cloud-init's recorded datasource to
tell a rolled-back root filesystem from IMDS never having answered, failing
loudly on the latter rather than accepting it as storage loss.
---------
Co-authored-by: brynmailer-mdc <bdm@mulgadc.com>
|
||
|
|
62c1378b79 |
fix: raise the Ubuntu minimum to 24.04 (mulga-ucvsq)
Ubuntu 22.04 was accepted by detect_os but the runtime apt list has never resolved on jammy, which ships dhcpcd5 rather than dhcpcd-base. No CI cell or E2E matrix installs on it, and the install docs already claim Ubuntu 26.04 and Debian 13 only, so drop the claim instead of carrying a jammy-conditional package branch for an untested suite. |
||
|
|
92c2de0017 |
feat(firewall): scope ssh to an operator allowlist in custom.nft (#881)
The generated policy accepted ssh from any source and setup.sh rewrote spinifex.nft on every run, so there was nowhere to record an allowlist that survived an upgrade. custom.nft is created once, never rewritten, and kept across a node reset. It holds a define rather than rules, so an operator supplies a value and cannot write a rule that fails the ruleset. The default accepts every source, which is what the policy already did. |
||
|
|
42d87d7a5a |
feat: EBS export tunables, plus blob-read fault isolation for ebsmetadata (#799)
* feat(ebs): make nbdkit thread count and per-volume read cache configurable Both numbers that set a volume's export concurrency and memory were hard-coded: nbdkit ran on its own default of 16 threads per connection because no -t was ever passed, and the read cache was a 128 MiB literal in the mount path. Neither could be changed without a recompile, and neither was visible in the logs or the process argv. Add default_threads and cache_size_mb to [nodes.<node>.ebs]. Defaults are unchanged, so a config that does not set them behaves exactly as before. CacheSizeMB is a pointer so an explicit 0 (cache disabled) stays distinguishable from an unset key, matching how ViperblockConfig treats its own toggles. -efi volumes stay uncached regardless. Validation is a range check only. Both are operator tunables applied per nbdkit process, and there is one of those per volume, so the host cost is the value times the volume count -- left for the operator to weigh rather than second-guessed here. * feat(security): arm the firewall by install path and sync the clock at firstboot The host firewall armed itself from a code default, so a curl-to-bash install onto an existing Debian or Ubuntu machine applied a default-deny INPUT policy seconds after bootstrap. Anything the operator was already running that is not on the allow list stopped accepting connections, with nothing logged and no config key to set beforehand — no template writes firewall_enabled, so every install fell through to the default. Arming is now the install path's decision. setup.sh takes --firewall=on|off and records it in /etc/spinifex/firewall/mode, defaulting on under ISO_BUILD and off everywhere else: the ISO is an appliance on hardware we define, a package install is a guest on a machine that was already doing something. firewall_enabled becomes a three-state *bool so "unset" and "explicitly false" stay distinguishable. Flipping the default to false instead would have torn down a working policy on every existing node, because false is an instruction to disable rather than an absence. Resolution is config, then mode file, then on, so a node installed before any of this keeps what it has. The ISO had the opposite problem. setup.sh is the only place that enables spinifex-firewall.service and it returns before that line under ISO_BUILD, with no systemd in the chroot to talk to. Nothing else enabled it, so after a reboot the ruleset — runtime state — was gone, and ReconcileFirewall short-circuited on an unchanged peer file and never put it back. An ISO node was firewalled until its first reboot and open permanently after. firstboot now enables the unit, and the reconcile checks the table is loaded rather than treating an unchanged peer set as proof the policy is applied. Two policy changes: 443 is held for the nginx TLS edge so that rollout needs no per-node firewall change, and the SSH port is read from sshd_config and its Include drop-ins instead of being hardcoded to 22 — a host on Port 2222 was allowed exactly one port that was not the one it uses, and ct state established kept the operator's session alive until they disconnected. 53 stays open on every node, now with a comment saying so: northstar serves public authoritative DNS. Clock: firstboot steps and waits for sync before spx admin init mints credentials, since a certificate issued against a wrong RTC carries a NotBefore that outlives the correction. Bounded to 60s and non-fatal so an air-gapped install still completes, and once is enough because rtcsync writes the corrected time back. A chrony drop-in replaces Debian's makestep 1 3, which stops stepping after three updates and then slews at roughly 7 seconds a day — a node that burned those before the network came up never visibly converged. * fix(security): let a node join a cluster whose firewall is already armed Expanding a single-node ISO install into a cluster could not succeed. Two independent blockers, both from the same root: the peer set is derived from converged cluster state, but the ports needed to reach convergence are gated on that same set. The formation port is peer-scoped, and a node dialling in to join is not a peer yet, so the handshake was dropped rather than refused and the joiner retried in silence until it timed out. It cannot simply move to the public rule: outside formation the same port carries the daemon cluster manager, whose /health and /local/* routes report node topology, service inventory and running instances unauthenticated. So it is opened for the formation window only, by spx admin init, and closed again on every exit path. The reconcile then deadlocked. Holding out for the full chassis list is right on a node with no policy loaded, but on one armed for a smaller cluster the ports a joining node needs in order to register its chassis are exactly the ones the stale set blocks, so the list can never complete. Widen the peer set on the tunnel set already loaded, and report the partial state so the caller retries sooner than the steady-state interval. A converged cluster whose Southbound DB is briefly unreadable is still left untouched. * docs(install): explain the firewall around cluster formation An ISO-installed server is a cluster of one, and its firewall admits internal cluster traffic only from members it recognises. Forming a cluster out of such servers therefore needs the firewall off first: step 3 of the multi-node guide has each server dial node 1's OVN database on the raft ports, and those are peer-scoped like everything else on the cluster plane. Neither guide said so, and the failure is a silent drop that looks like a network fault. Both guides now walk the off / form / on sequence, and the multi-node guide gains a reference section covering which ports are public, how arming differs between the ISO and the binary installer, and how to verify membership landed. Re-enable the boot-time unit whenever the daemon arms the policy. Disabling the firewall to form a cluster also disables that unit, so re-arming used to look complete while leaving the node bare after its next reboot. * fix: make the ISO-to-cluster conversion path work end to end Forming a cluster from four ISO-imaged servers surfaced a run of bugs that share a starting state CI never exercises: the ISO delivers an initialized, armed, running node, while the conversion path was written against the binary installer's unconfigured one. - install-node.sh never disarmed the host firewall, so nodes 2 and 3 could not dial the first node on the OVN raft ports and formation could not proceed. It now owns the whole lifecycle: disarm, form, re-arm, then verify the loaded policy against the expected peer set. - spx admin init left the admin access key and secret empty on the preserve path. The pair cannot be read back, and the IAM store is rebuilt by formation, so the empty strings reached every joiner's bootstrap.json and crash-looped awsgw. It is reissued instead, and IAM seeding now skips an empty admin block rather than taking the gateway down on every restart. - node-reset.sh left /etc/default/ovn-central behind. Raft membership lives in that file, not in the databases the reset deletes, so ovn-central recreated the database as a cluster member dialling a peer that had itself been wiped. - node-reset.sh also destroyed the installed firewall policy, which nothing regenerates. set-peers then failed on every attempt and the node stayed open permanently and silently. The arming mode is read before the wipe and the stage regenerated after it. - spinifex-firewall-apply rejected every verb when the policy file was missing, including disable. Turning the firewall off is the recovery path, so that left a node that could be neither armed nor disarmed. - viperblock exited 0 on a fatal startup error, so Restart=on-failure never fired. During formation its JetStream bucket has no leader yet, so the EBS provider died for good and every volume request failed with no responders. predastore and qemunbd had the same bug. - spx admin images import created image directories at 0700, so the first sudo import locked group members out of a tree deliberately made group-writable. Three of these hid behind checks that cannot succeed: ovn-sbctl show against a clustered database, and the OVN northbound and southbound waits in setup-ovn.sh. All three failed to stderr and let the run continue, so a check that could never pass was indistinguishable from one that was merely slow. The USB install guide claimed the ISO leaves Spinifex unconfigured and told the operator to run spx admin init. firstboot has always done that itself, so the guide now describes what the ISO actually produces and how to start using it. * fix: let spread placement launch across every node A spread placement group reserved four distinct nodes correctly and then failed the launch with ServerInternal, having started only two or three of them. The scheduler was never at fault; two faults downstream stopped the instances following the reservation. vpcd subscribes to vpc.add-nat with QueueSubscribe, which delivers one message at a time, and the handler holds its reply across the OVN flows barrier. The 45s caller deadline was sized against a single 30s barrier, which is right for one instance and wrong for the N a spread launch issues at once — the third request waits behind two full barriers and times out. That one subscription now overlaps its handlers under a bounded semaphore. Each barrier still syncs after its own write, so the guarantee is unchanged while N barriers collapse into roughly one. With the requests overlapping, every barrier still ran to its alarm. install-node.sh computed OVN_REMOTE after building the database nodes and gave it only to compute nodes, so the database nodes were configured without --ovn-remote. setup-ovn.sh writes ovn-northd's NB/SB connections from that list and skips it on the localhost default, and it already documents what follows: a northd dialling only its local member stops advancing nb_cfg once raft leadership moves, wedging ovn-nbctl --wait=hv. The list is knowable before any node is touched, so it is computed first and passed to the database nodes too. Nothing reported an OVN fault while this was happening. Every chassis was registered, ovn-controller and IPsec were up, and the raft cluster was healthy. The only signal was the barrier logging that it had overrun and was continuing without confirmation — which reads like slowness and was a permanent wedge. * feat: sweep block sizes in the disk benchmark and add an iperf3 network benchmark * fix: use iperf 2 with CSV output and report why a remote start failed * fix: stop pkill matching its own shell and verify the iperf server is listening * ci: run the predastore throughput benchmark at the end of the nightly * ci: boot the ISO in the nightly, single-node and three-node * ci: use the existing CI node password secret in the ISO cells * ci: report free space before the benchmark instead of failing inside warp * ci: keep the benchmarks and node disks off tmpfs * ci: export the work directories from RUNNER_TEMP rather than job env * ci: run the ISO and benchmark workloads from the nvme scratch area * perf: run guest NICs on vhost-net with multiqueue Guest-to-guest VPC throughput measured 1.68 Gbit/s single-stream against 21.8 Gbit/s host-to-host on the same underlay, and did not improve with more streams. QEMU's -netdev tap defaults vhost to off, so the whole datapath ran in the main loop thread in userspace: that thread sat at 59-65% CPU while all four vCPU threads idled at ~4%. Every tap netdev now carries vhost=on, and VPC ENIs additionally run multiqueue at min(vCPUs, 8) queue pairs. Multiqueue needs all three of the tap, the netdev and the device to agree, so TapNetDev and NetDevice derive the netdev options and the 2N+2 MSI-X vector count from one queue figure rather than leaving callers to keep them in step. The QMP hot-plug path takes the same options as cold boot, with a test comparing it against the rendered cold-boot strings so the two cannot drift. MMIO machines stay single-queue: they have no MSI-X. * ci: check out the sibling repos the go workspace needs in the ISO cells * ci: skip cell-21 workload cleanup when the workload never ran * ci: size the cell-21 node at 8 GiB and keep its serial log * ci: keep the cell-21 node diagnostics alongside the serial log * fix: let the daemon open /dev/vhost-net and delete multi_queue taps Enabling vhost=on broke instance launch two ways. DevicePolicy=closed gates the cgroup device list before capabilities are consulted, so QEMU's open of /dev/vhost-net returned EPERM despite CAP_DAC_OVERRIDE; add the device to the allow list and bump the unit version. Separately, `ip tuntap del` re-opens the device with TUNSETIFF and fails with EINVAL on a multi_queue tap, leaking it on every teardown; route deletion through `ip link del`, which is flag-agnostic. * perf: default guest NICs to a single queue Multiqueue measured a net loss. Spreading one flow across queue pairs reorders packets and TCP reads that as loss: a 4-vCPU guest fell from 1.76 to 1.50 Gbit/s, with cwnd collapsing on spurious retransmits. The host overlay funnels a node pair onto one softirq core, so the extra queues have no headroom to win back what the reordering costs. Keep the plumbing and its tests behind MultiqueueNICs so re-enabling is one line once that funnel is fixed. vhost-net stays on unconditionally; it moves the datapath off the QEMU main loop, measured at 60% of a core under load against 3% with it. * fix: raise the UDP receive buffer for predastore's QUIC transport Predastore carries blob, meta and raft over QUIC and quic-go asks for a 7MiB receive buffer. Left at the kernel default of 208KiB it silently dropped datagrams under load: the four-node cluster had shed 80k-125k each, which failed shard writes, put raft into repeated elections, and ultimately handed guests an I/O error that cost two of them their root filesystems. Adds a sysctl stage writing /etc/sysctl.d/99-spinifex-net.conf, so the setting lands in the ISO image and on every node push rather than living in a runbook. * ci: give the cell-21 workload an identity the node accepts * feat: tie the guest MTU and NIC multiqueue to ipsec_enabled ESP costs 34 bytes on top of geneve's 58, so a cluster running the overlay in plaintext can advertise 1442 instead of 1408 — worth roughly 10% of guest throughput. Derive it from network.ipsec_enabled rather than hardcoding the conservative figure. Multiqueue moves with the same flag, because its sign depends on it. Behind IPsec it costs ~12%: ESP has no L4 ports, so RSS funnels a node pair onto one core and extra queues only reorder packets, which TCP reads as loss. Without IPsec the sending host's single vhost thread saturates first and queues are worth +54%. IPsec on with multiqueue on is the worst of the four combinations, so it stops being a standalone knob and becomes vm.Deps.MultiqueueNICs. The reconciler only ever created a subnet's DHCPOptions row and never revisited it, so the create-time MTU stuck for the life of the subnet and this change would have applied to new subnets only. Worse in the other direction: turning IPsec back on would have left subnets advertising 1442 over ESP, which drops large segments with no ICMP to recover from. applySubnets now diffs and updates in place. reconcile.Config takes IPSecDisabled rather than IPSecEnabled so the zero value is the conservative MTU — a caller that forgets it is merely slower. * docs: add an install-time performance tuning guide Measured on the four-node cluster rather than inferred: the UDP receive buffer sysctl, what IPsec actually costs and why, the multiqueue sign flip, the overlay MTU budget, and the jumbo-frame check that must precede enabling it. A starter doc — several sections end in an open question rather than a recommendation. * ci: keep the cell-21 node alive for the workload step * ci: collect the cell-21 qemu log and widen its timeout * feat: derive the guest MTU from the fabric, and deepen the virtio NIC config The overlay overhead is passed on to the guest rather than hidden from it. Hiding it means running the fabric far enough above 1500 that a standard guest MTU fits in the headroom, which is what the large public clouds do — but they own the switches. On a fabric we do not control, the honest figure is the one the path can carry, and a jumbo underlay should reach the guest: 9000 gives 8942, or 8908 with IPsec. network.underlay_mtu is the lever; SubnetMTU spends it. Configured rather than probed, because a node's own NIC MTU says nothing about the switch between it and its peers. host_mtu sets VIRTIO_NET_F_MTU so a guest that never takes a DHCP lease — statically addressed, or IPv6-only — still learns the ceiling. rx/tx_queue_size raise the virtio ring from QEMU's default 256. That default is a packet-rate ceiling rather than a memory saving: a vCPU preempted for a fraction of a millisecond fills all 256 slots and the overflow is dropped. ethtool is the only way to read NIC offload, ring and channel state, so a node without it cannot be diagnosed for throughput at all. * ci: give the cell-21 workload its own guest key * fix: set the guest MTU on the tap, not just in the guest The tap was created and brought up without an MTU, so it stayed at the kernel default of 1500 while DHCP and host_mtu told the guest something else. Harmless at 1442; it silently blackholed every large frame on a jumbo underlay, with no ICMP back because the drop is at the first hop. TapSpec.MTU comes from the same guest overlay MTU the DHCP option and host_mtu already use, and is applied in the bring-up call so a size the fabric cannot carry fails the launch instead of degrading quietly. * fix: stop setting tx_queue_size, which QEMU caps at 256 for tap QEMU only honours a tx_queue_size above 256 for vhost-user and vhost-vdpa backends. On a tap it rejects the value outright rather than clamping it, so every launch died with "must be a power of 2 between 256 and 256" and the instance went straight to terminated. rx_queue_size is unaffected and stays at 1024. A test pins the absence of tx_queue_size across machine types and queue counts. * docs: lead the tuning guide with the overlay segmentation finding The guide's headline was a 5.4x that came almost entirely from turning IPsec off, and it treated MTU and the fabric as the main levers. The host reaches 92.6 Gbit/s at MTU 1500 on the same NIC, so the fabric is not the constraint and the encrypted default is not the thing to tune away from. Adds the host-versus-guest comparison up front, documents network.underlay_mtu, and makes the missing segmentation offload the first open question. * ci: stop deselected matrix cells failing in teardown * docs: quantify what disabling overlay IPsec is worth The guide described the trade without the numbers an operator needs to make it. Adds the measured 4.9x, notes that the MTU and multiqueue changes follow ipsec_enabled rather than being separate knobs, and records two transition hazards: a stale wide MTU on running guests, and RunInstances failing while the OVN flows barrier catches up with the new SAs. * ci: collect and retain the e2e benchmark and cluster logs Cells 21 and 22 both copied two paths that only ever exist on the nodes, so the benchmark JSON was never uploaded and cell-22 collected nothing at all. Both now gather what they actually produce, and keep it for 90 days. * fix: quieten spx by installing an explicit CLI logger default spx never set a process logger, so it inherited whatever a linked package left behind — until now a JSON handler at Info on stdout, interleaving library log records with command output and breaking piped use. Execute() claims the default before any command runs: text on stderr, LevelError, so commands report failures through their own stderr writes and libraries stay quiet. --verbose/-v raises to info and SPX_LOG_LEVEL sets an arbitrary level, the flag winning over the environment. Service subcommands still call initTelemetry, which replaces the handler outright. No root --debug flag: viperblock, qemunbd, nats and awsgw each define their own --debug with a service-specific meaning, and a root persistent flag would shadow inconsistently depending on the command. The guard test samples the handler at package-init time rather than inside the test, because tests in this package start services that install their own logger legitimately. * feat: private /admin/CreateAccount for self-service tenant signup Add POST /admin/<Method> to the AWS gateway: SigV4-signed, JSON in and JSON out, callable only by an IAM user in the super-admin account holding spinifex:<Method>. CreateAccount is the one method, so a signup form can provision a tenant without an operator shell. No new service, port, unit or certificate — it mounts inside the gateway's existing authenticated group and inherits its auth, throttling and tracing. Provisioning is resumable rather than transactional, which fits stores that have no transaction. Two CAS creates carry the correctness: the client token admits one in-flight attempt and makes a lost response replayable for 24 hours, and the name reservation makes duplicate account names impossible. Every step after the account exists is create-if-absent, so a retry with the same token finishes the job instead of failing. The CLI and the endpoint share one provisioning helper, which closes a gap on both at once: CreateAccount never checked names, so running `spx admin account create` twice produced two accounts that differed only by ID. The response waits for the account's default VPC over a new ec2.EnsureDefaultVpc request/reply, rather than trusting the existing fire-and-forget iam.account.created publish — credentials for an account that cannot launch anything are worse than a slower call. [signup] max_accounts bounds how many accounts may exist; absent means uncapped, which is what every cluster does today. * fix: stop the awsgw template hardcoding one deployment's console URL console_url shipped as https://console.spx3.com, so every fresh install — including an on-premise cluster that will never run signup — was configured to point new accounts at our console. It is the only deployment-specific domain in any template. It now ships empty, and the gateway warns when it provisions an account without one, since a blank sign-in link is otherwise visible only to the customer who receives it. Extract the remote client from the command body while here. The signing, request shape and error decoding are the part a Cloudflare Worker mirrors, and as a function they are testable against a TLS test server rather than only by hand against a live cluster. * refactor: drop console_url from signup and default max_accounts to 128 The gateway never read console_url — it passed the value straight through to the response, and the idempotency record froze it for 24 hours so a corrected typo still replayed stale. The client that made the request already knows where it wants to send the new tenant. max_accounts is now a pointer in the parsed config so an absent [signup] section takes the 128 default while an explicit 0 still means uncapped. * feat: run the predastore fault-injection harness as cell-24 Cell-23 asks how fast predastore is when every node is healthy; cell-24 asks whether it survives one that is not. It runs after cell-23 rather than beside it: both want a quiet single runner, and a benchmark sharing a machine with a fault injection run measures the wrong thing. The port offset keeps the two clear of each other even so, and the job clears stale nodes on entry and exit, since a run killed before its cleanup trap leaves one holding ports that fail the next run somewhere unrelated. * ci: keep the throughput benchmark's output with its results The run log only existed in the job log, so the artifact it uploaded could not be read without going back to the run that produced it. * ci: keep the fault-injection run log with its results events.txt carries the timeline and the FAIL line, but not the build output or anything Warp wrote before the harness took over, so a failed cell could only be read from the job log it was printed into. * fix: serve the cluster region to the console instead of hardcoding it The console hardcoded ap-southeast-2 as its SigV4 region in seven files, so on any other cluster the credential scope was wrong and the gateway rejected every signed request. The SPA is embedded in the binary, so a build-time value would pin one binary to one region. The UI server now serves GET /api/config with the region, no-store so a proxy fronting several clusters cannot serve one the other's region, and the SPA loads it once before render. The region comes from the serving node's config because awsgw pins signature verification to that same field. Reading the cluster-wide [aws] region instead would let a cluster whose two keys disagree pass review and still fail to authenticate. Also relabels the login card as Spinifex credentials, since the fields are not AWS ones, and hides the CA install banner unless the console is reached directly: behind a proxy with a publicly trusted certificate there is nothing for the cluster CA to fix. * fix: say once when the host firewall will not be maintained Both quiet outcomes of the reconcile — no cluster config, and the policy switched off — return nil without logging, so a node that never arms is indistinguishable in the journal from one that armed on its first pass. * test: arm the host firewall before asserting on its peer set Only the ISO install arms the policy; every other path writes off to the mode file, so the daemon disables the firewall and never writes a peer set. The test read that file as its baseline, which it could never have. It now switches the mode on for its own duration and puts it back, waits for the peer set the way install-node.sh does, and on failure reports the mode, the node count and what the daemon said rather than just the missing file. * test: move the console region test to the external cmd package It was in package cmd, which test-package-check rejects, so preflight failed on the branch. The hook follows the pattern already in export_test.go. * test: make the reboot EIP diagnostic capable of naming the drop The two ofproto/trace probes injected packets with no TTL, so OVN's router killed them at lr_in_ip_input and both traces ended early for a reason that had nothing to do with the failure under investigation. A keyword filter then stripped the table-match lines, hiding where each trace stopped. Traces now carry a TTL and are kept whole, the real datapath megaflows for the guest reply are dumped alongside them, and any drop matching the guest source is resolved from its OpenFlow cookie back to the Southbound logical flow that installed it. * fix: exempt an EIP instance from the subnet drop gate with allow, not reroute A subnet with no route of its own carries a priority-1100 drop policy, and an instance with an external IP is lifted above it by a priority-1200 policy. That policy rerouted to the pool gateway, which in distributed NAT is outside every logical router port subnet, because the gateway LRP is the link-local /30. The static default route survives that by naming an output port; a routing policy has no such field, so ovn-northd discarded all three of them and the drop gate below swallowed everything the instances sent. The effect was that every external IP answered inbound traffic and none of it came back: the SYN reached the guest, the guest replied, and the reply died in the router's policy stage. Guest-initiated egress was lost the same way. The policy only ever needed to lift the gate. The router's default route already points at the gateway, so allow leaves the routing decision intact and gives northd nothing to reject. * test: match the log the firewall quorum gate actually emits The assertion waited for "chassis encap addresses; not writing a partial peer set", which no code has ever logged. The reconcile reports a short chassis list as "OVN reports N of M chassis encap addresses" and the maintain loop carries that into its retry warning, so the wait could only ever time out. Arming the node in the previous commit got the test as far as this assertion for the first time, which is why it surfaced now. The failure also prints the journal tail and the same inputs the earlier wait reports. * fix: stop one unreadable volume document failing every volume listing A single volume document whose shards no longer reconstruct made DescribeVolumes, DescribeVolumeStatus and DescribeVolumesModifications fail for every account, because the listing returned the first fetch error rather than skipping the document. ListVolumes now skips a document it cannot read or decode and logs the skip, mirroring ListAMIs. Callers whose answer would be wrong rather than merely partial take ListVolumesStrict: the orphan scan and the snapshot in-use check both gate destructive work on a complete list. The tolerance covers fetch failures as well as decode failures. An object whose shards no longer join is as unusable as one whose bytes will not parse, and it was the fetch path that took the cluster down. |
||
|
|
91d22d9f12 |
feat(security): add an nftables host firewall scoping cluster ports to peers (#769)
* feat(security): add an nftables host firewall scoping cluster ports to peers Nodes shipped no host firewall, so every cluster listener — OVN NB/SB, the formation port, NATS, predastore — was reachable from anything that could route to the node. On a single-NIC node the planes collapse onto the public address, which made that the default rather than the exception. setup.sh installs a policy and an apply helper but does not enable them: the peer set is unknown until the cluster's planes resolve, and a drop policy with an empty set would cut the first node that applied it out of its own formation. install-node.sh writes the peers and enables the unit after formation. The policy owns only table inet spinifex_filter and replaces it in one transaction. vpcd writes MASQUERADE and per-EIP FORWARD rules into the ip nat/filter tables and reinstalls them only on start, so a whole-ruleset flush — what Debian's nftables.service does on both start and stop — would break elastic IPs silently. INPUT only, for the same reason: a forward-hook drop here could not be rescued by an accept in the other table. Guest traffic keeps working: IMDS and VPC DNS terminate on ime-* ports in the host netns, and every guest agent reaches its control plane over the AWS gateway rather than NATS, so no cluster port needs to face the guests. * feat: reconcile the host firewall peer set from the daemon The peer set was written by install-node.sh and by cluster-bootstrap.yml. That missed two of the four formation paths (bm-bootstrap.sh and the ISO firstboot), duplicated the same logic in each, and went stale as soon as a node was added or replaced. host.ReconcileFirewall now owns it: every formation path starts the daemon, and it re-runs on each startup. A node's own config names its peers by their wan address only, so a set built from config alone drops every peer's NATS, OVSDB and formation traffic. The lan plane comes from the generated NATS cluster routes and the OVN remote lists, and the vpc plane from the Southbound Encap table; an empty encap answer is an error rather than a narrower set. ProtectSystem=full applies to the sudo child too, so the root helper could not write /etc/spinifex/firewall either — it is now in the daemon's ReadWritePaths, optional so a node installed before the firewall stage still starts. The apply helper gains set-peers and disable verbs, re-validates every address as a dotted quad with in-range octets, and rolls the peer file back if the ruleset will not load. * fix: retry the host firewall reconcile until every chassis registers The peer set is only safe to write once OVN reports an encap address for every node. On a fresh bootstrap the daemon routinely wins the race against ovn-controller, so a single startup attempt saw a partial chassis list and either wrote a set that dropped Geneve from the nodes missing from it, or failed outright and left the node with no policy until a restart. Gate on the full chassis count and schedule the reconcile instead of running it once: back off from 15s to 5m while it fails, then re-run every 5m so a node added or replaced after formation is picked up without a daemon restart. An unchanged peer set short-circuits before the helper runs. * test: cover the firewall chassis quorum gate in the multinode e2e suite A partial chassis list is the normal state early in a bootstrap, and writing a peer set from one produces a firewall that drops Geneve from every node missing from it. The gate that refuses that write had no live coverage: a 5-node bootstrap converges too fast for any daemon to observe a partial list, so the verification run only ever exercised the OVN-unreachable path. Reach the branch by inflating the expected count instead of breaking OVN: a phantom node in one node's config makes the cluster one chassis short, with nothing in the Southbound DB disturbed. Asserts the gate logs, that no peer file is written while it holds, that the loaded ruleset survives, and that the node recovers to a byte-identical peer set once the phantom is removed. |
||
|
|
5c6429bde1 |
fix(ipsec): stop charon on nodes that do not use OVN IPsec (#768)
The daemon only called EnableOVNIPSec when network.ipsec_enabled was true, so the disabled case was never reached and nothing ever turned the host's IPsec services off. Since setup.sh installs openvswitch-ipsec and strongswan-charon unconditionally and the packages enable their units, charon listened on 0.0.0.0:500 and 0.0.0.0:4500 on every node -- including single-node clusters, where EnableOVNIPSec short-circuits and IPsec is never switched on at all. ReconcileOVNIPSec runs on every startup and resolves the state both ways. It self-heals: a single-node box that later joins an IPsec-on cluster gets the services back through the same call, which a static install-time mask could not do because setup.sh runs before the topology is known. The unit changes go through a new fixed-verb root helper rather than systemctl. spinifex-daemon holds three narrow sudo grants and none of them is systemctl, which is deliberate: a NOPASSWD systemctl rule takes an arbitrary unit name and is root-equivalent. The helper takes only on|off and names the units itself, matching the existing spinifex-set-endpoint-sysctl pattern. Only the read-only is-enabled and is-active probes are run directly, and a test pins that. strongswan-starter.service is disabled in both states. ovs-monitor-ipsec execs the strongSwan starter itself rather than going through that unit, so it only ever competes for UDP 500/4500 -- confirmed on a live IPsec-enabled cluster, where charon's parent is /usr/lib/ipsec/starter and the unit is inactive. A nil cluster config leaves the services alone rather than guessing. This is the bind-address half only. On a multi-node cluster charon must run, and it still binds the wildcard; restricting that reach to the encap plane is the host firewall's job. |
||
|
|
2e09461080 | chore: cleanup code comments | ||
|
|
b76aab8b50 | feat(installer): three-plane networking, ZFS root, distributed NAT and multi-node install (#663) | ||
|
|
a2c451128d |
fix: unblock the Ubuntu 26.04 installer (qemu-kvm, sudo-rs) (#665)
setup.sh aborts twice on resolute. qemu-kvm is a virtual package with two providers there, so apt refuses to resolve it; the token was redundant anyway since $QEMU_PACKAGES already installs qemu-system-x86/arm and spinifex execs the qemu-system-* binaries directly. sudo-rs, Ubuntu's default sudo since 25.10, then rejects the sudoers file: it implements no pam_session Defaults setting, and forbids a wildcard inside a command argument. pam_session is now emitted only for classic sudo, and the sysctl grant names a fixed-verb helper instead of a wildcard. The helper is narrower than the rule it replaces: it accepts one interface, a key restricted to rp_filter or accept_local, and a value restricted to 0 or 1, where the old grant permitted any net.ipv4.conf key at any value. Granting sysctl with an unconstrained argument was rejected as root-equivalent. Adds scripts/lint-apt-packages.sh and an Apt Packages workflow so the runtime package list is resolved against each supported suite's real indices in CI. |
||
|
|
dad5d702e1 |
fix: stop lbagent heartbeats on positive LB deletion, and actually enable the JetStream watchdog (#643)
* fix(lbagent): stop heartbeating a load balancer once it is confirmed deleted A LoadBalancerNotFound response is the gateway's positive confirmation that the store has no record for the LB, not a connectivity failure — unlike a dial error, timeout, or 5xx, which leave its existence unknown and must keep retrying. Past the startup registration grace window (or after any prior successful heartbeat), it can no longer be the record's own replication race, so the agent now stops rather than retrying forever and filling the log with heartbeat noise after teardown. * fix(nats): enable the JetStream ENOSPC-latch watchdog timer nats-server disables JetStream process-wide on ENOSPC (server/jetstream.go handleOutOfSpace -> ShutdownJetStream) and never re-enables it itself — that decision is nats-server's own internal state, not spinifex's, so a restart is the only way back. The spinifex-nats-watchdog.timer + service already probe /healthz?js-enabled-only=true and try-restart on a sustained failure, but the timer's WantedBy=timers.target never took effect: neither setup.sh nor firstboot enabled it, so the watchdog shipped inert and a full disk needed a manual restart forever. Enable --now it alongside the rest of the unit set. |
||
|
|
9f5f877e50 |
fix: batched hygiene — slog key, ui pid file, race-scaled timeouts, GPU console capture (#637)
* fix(ec2): rename ambiguous 'code' slog key to firmwarePath The EFI variable store prep log used 'code' for the OVMF firmware path, which reads as an error/status code in log search. Rename to firmwarePath to avoid confusion. * fix(spinifexui): write pid file to a service-owned BaseDir spinifexui.Start() called the legacy utils.WritePidFile, which has no MkdirAll and falls back to $HOME/spinifex. Under the spinifex-ui unit's ProtectHome=yes this directory is neither guaranteed to exist nor writable. Add Config.BaseDir, switch to utils.WritePidFileTo (which does MkdirAll) for Start/Stop/Status, wire it through the CLI as a spinifex-ui-base-dir flag/SPINIFEX_UI_BASE_DIR env var, provision /var/lib/spinifex/spinifex-ui in setup.sh, and add it to the unit's ReadWritePaths. * test(viperblockd): replace fixed sleep with a readiness poll TestEBSConfigQueueGroup_DetachedOpenFails slept 500ms before assuming launchService's ebs.config subscriber was bound, then raced a hardcoded 5s request deadline. Poll with a cheap malformed request (rejected at json.Unmarshal, before the slow S3 path) until the subscriber answers, then issue the real request with room for openVolumeVB's S3 backoff. * fix(e2e): capture GPU worker console log on test failure Wire harness.OnFailure into TestEKSGPUPodExposure to dump the GPU worker's serial console via the established EC2 GetConsoleOutput path, matching lb_test.go's captureLBConsoleOnFailure. A driver or device-plugin hang after boot only ever surfaces on the guest console. |
||
|
|
628fbbc0c3 |
fix: group-scope the OVS/OVN sockets and retire the vpcd sudoers grants (#609)
* fix: group-scope the OVS/OVN sockets and stop sudoing read-only probes The OVS DB socket and both sets of ctl sockets were chmod 0666 by setup-ovn.sh, with a systemd override re-applying it on every openvswitch-switch restart. Write access to db.sock is full control of the local datapath, so this handed the datapath to any account on the box. Both service users run with Group=spinifex, so the access is now 0660 root:spinifex, /var/run/ovn is 0750, and a shared helper re-applies it from ExecStartPost on openvswitch-switch and ovn-controller alike — the latter is new, and matters because the ovn-controller ctl socket name embeds the pid and is recreated on every start. That also fixes the health probe reporting ovn-controller as not_running on a healthy node. It shelled out to `sudo ovn-appctl`, which only spinifex-vpcd is granted; as spinifex-daemon sudo demanded a password and the swallowed error read as OVN being down. With the ctl socket group-owned the probe needs no privilege, so health.go moves to a non-escalating Runner rather than the alternative of granting the daemon a root-equivalent ovn-appctl rule to read a status. ListIMDSTaps ran `list-ports` plus one `get` per patch port on vpcd's 15s tick, so 1+N sudo invocations every tick, each one logging a pam_limits warning about the core rlimit the unit deliberately pins to 0. It now issues a single JSON query per pass, and the sudoers drop-in disables the PAM session for both service users, which also leaves sudo children inheriting the unit's rlimits. An absent iface-id on a patch port is now skipped with a warning instead of aborting the pass: it is the only record of the full ENI, so such a port cannot join the live set either way, and failing the pass stalled reconcile for every healthy port behind it. A transient query failure still aborts. * fix: group-own the OVS/OVN pidfiles too, and cover the ipsec ctl socket Group-owning the ctl sockets was not enough for `ovn-appctl -t ovn-controller`: it resolves the pid-named socket through the pidfile, and OVS opens that O_RDWR to test the fcntl liveness lock, so a group-readable pidfile still fails the probe with EACCES. The pidfiles now get the same 0660 root:spinifex, which also tightens them from the 0644 they ship with. openvswitch-ipsec joins the override list because setup-ovn.sh restarts it after the sweep runs, leaving its ctl socket as the one file still at the shipped mode. Verified on the dev node: every socket and pidfile is 0660 root:spinifex and survives a restart of all three units, an unprivileged user is refused, and /health reports ovn-controller ok where the sudo probe read not_running. * refactor: stop escalating the OVS/OVN socket clients Now that setup-ovn.sh group-owns the control sockets, ovs-vsctl, ovs-appctl, ovn-nbctl, ovn-sbctl, ovn-appctl and systemctl reach their daemons as the service user. utils.NeedsPrivilege carries that policy and both command builders consult it, so ip, iptables, dhcpcd, sysctl and arping still escalate while the socket clients no longer do. Their sudoers grants are removed: each took unrestricted args and all of them accept --log-file=PATH, so every one was a root-equivalent grant handed out to run a query. ovs-ofctl keeps its grant. It talks to a per-bridge <bridge>.mgmt socket that ovs-vswitchd creates when the bridge appears, including bridges spinifex creates at runtime, so the provisioning sweep cannot group-own it up front. The NB and SB database sockets join the sweep for ovn-nbctl and ovn-sbctl. vpcd carried its own sudoCommand copy that escalated unconditionally, bypassing the policy entirely. It survived only because the grants existed and broke the OVN flows-ready barrier the moment they were removed, so it now delegates to utils.SudoCommand. TestRG10_SudoOnlyThroughThePolicy fails the build if another package reintroduces a local copy. Verified on the dev node: an instance launches, IMDS is served, the flows-ready barrier completes, and no sudo denial appears anywhere in the journal. * refactor: drop every spinifex-vpcd sudoers grant for ambient capabilities vpcd held NOPASSWD grants for ip, iptables, sysctl and arping. The ip grant alone was root-equivalent: sudoers cannot constrain its arguments, so `sudo ip netns exec <ns> /bin/sh` was a root shell for the service account. The unit already grants CAP_NET_ADMIN and CAP_NET_RAW ambiently, and the kernel passes an ambient set to each child on exec, so those tools work as the service user with no escalation at all. Verified on a live node: all sixteen ip subcommands vpcd issues, plus iptables reads and writes, sysctl -w on the net.ipv4.neigh tree, and arping, all succeed under exactly the unit's ambient set. spinifex-vpcd now has no sudoers rules. NeedsPrivilege had to become capability-aware to do this. spx is one binary shared by both service units, and the daemon holds CAP_SYS_ADMIN and CAP_DAC_OVERRIDE but no CAP_NET_ADMIN, so a static tool list cannot express "vpcd runs ip directly, the daemon escalates it". The decision now reads CapAmb from /proc/self/status once and matches it against the capability each invocation needs. sysctl is resolved per key, since CAP_NET_ADMIN covers the net.* trees and nothing else. The dhcpcd grants go too: neither daemon invokes it. Only setup-ovn.sh, which runs as the provisioning user, and the in-guest ecs-agent. TestRG10_VPCDHoldsNoSudoersGrant pins both halves together, so a future grant cannot be re-added without also explaining why the capability stopped working. * chore: restore routeTree.gen.ts swept in by mistake * fix: probe ovn-controller with ovn-appctl, not ovs-appctl checkOVNController's first probe passed a bare -t ovn-controller to ovs-appctl, which resolves it against OVS_RUNDIR — /var/run/openvswitch. ovn-controller's socket and pidfile are in /var/run/ovn, so the probe could never succeed and logged "ovn-controller.pid: open: No such file or directory" on every check. Not a functional break: the next probe globs the full /var/run/ovn path and succeeds, so the function still returned nil. It cost an exec per check and made a healthy node look like it was failing an OVN liveness probe. ovn-appctl defaults OVS_RUNDIR to /var/run/ovn, so the common case now matches first. The glob and systemctl fallbacks stay for older layouts. |
||
|
|
e79ca59d4b | fix: configure host DNS from spx admin init/join (#582) | ||
|
|
1d55404a73 |
revert: host DNS setup on resolved/resolvconf hosts (#580)
This reverts commit
|
||
|
|
f9c9f0b38d | fix: configure host DNS for Spinifex zones on resolved and resolvconf hosts (#580) | ||
|
|
28a876d17d | feat(dns): resolvable ALB/NLB + EKS DNS, forwarder hardening, cross-tenant reconcile (#532) | ||
|
|
e1c4f85a36 |
feat: routed-NAT external mode with two-tier ingress (#475)
* feat(network): add routed uplink mode, Routed wiring, and NAT egress rule helper * feat(external): route gateway LRP over transit pool and install VPC SNAT in routed NAT mode * feat(vpcd): support bridge_mode=nat (routed uplink, transit pool, egress rules) * feat(daemon): register EIP handlers unconditionally with disabled-mode stub; seed default subnet per external mode * feat(admin): support --external-mode=nat and suggest it for non-bridgeable uplinks * feat(scripts): add --nat-uplink routed mode to setup-ovn.sh * test(e2e): add routed-NAT single-node natuplink suite Covers the external_mode=nat lane end to end on a nat-initialized node: host transit wiring (veth, br-ext port, ip_forward, iptables egress rules), spinifex.toml contents, disabled EIP surface (empty describe-addresses, UnsupportedOperation on allocate), default subnet MapPublicIpOnLaunch=false, OVN gateway LRP + VPC SNAT on the transit /24, guest outbound egress proven via a serial-console probe (nat mode has no inbound path), and unique transit gateway IPs across VPCs. Suite self-gates on external_mode=nat; registered as e2e-natuplink and in SUITES_BUILD so it compiles in CI. Manifest entry stays commented until CI can provision a nat-mode environment. * feat(ovn): Address_Set CRUD and NAT exempted_ext_ips column Adds the exempted_ext_ips column (optional strong Address_Set ref) to the nbdb NAT model, Address_Set ensure/get with wait-op create semantics, and an in-place SetNATExemptedExtIPs update on the client interface, live client, and mock. Test NB schema gains the column and covers insert-resolves-UUID, converge, clear, and missing-NAT paths. * feat(policy): exempt address set on routed SNAT/EIP rows Adds WithSNATExemptSet so routed mode stamps exempted_ext_ips (the spinifex_nat_exempt Address_Set: transit /24 plus operator extras) on IGW snat and EIP dnat_and_snat rows, keeping VM replies to host-initiated flows un-NATted. AddSNAT gains an idempotency guard keyed on (router, VPC CIDR) with stale-IP replacement, and both AddSNAT and the AddEIP idempotent-skip path patch the ref in place on pre-existing rows. The set is a singleton strong ref and is never deleted. Non-routed modes are unchanged. * feat(host): VPC ingress route primitives for routed-NAT mode EnsureVPCIngressRoute / RemoveVPCIngressRoute manage the host route that sends VPC-CIDR traffic into OVN via the gateway LRP transit IP on the spx-nat veth. Replace/del semantics keep both idempotent; a missing route on removal is not an error. * feat(external): routed ingress leg on IGW attach/detach, reconcile-safe AttachIGW's routed leg now also installs the host VPC ingress route via RoutedIngressHooks, and re-runs on the already-attached path so the reconcile loop restores host routes (and patches legacy SNAT exempt refs) after a reboot — OVN state survives restarts but host routes do not. DetachIGW removes the route alongside the SNAT. vpcd wires the hooks and the spinifex_nat_exempt set (transit /24 + [network] nat_exempt_cidrs, validated nat-mode-only) exclusively in routed-NAT mode; pool/veth/direct pass nil hooks and are unchanged. * test(natuplink): Tier 1 host-ingress phase; docs for jumpbox pattern New Phase 7 asserts the automatic ingress tier: host route to the VPC CIDR via the gateway LRP transit IP, exempted_ext_ips ref on the SNAT row pointing at spinifex_nat_exempt (containing the transit /24), and — after opening the SG from the transit net (default-closed, AWS parity) — ping and an sshd TCP handshake against the instance private IP from the host, which proves the un-SNATted return path. Phase 8 additionally waits for the second VPC's ingress route to appear on IGW attach. vpc-networking README documents the jumpbox pattern, SG note, and nat_exempt_cidrs. * feat(config,admin): public wan pool alongside nat-transit Restructure admin config generation from single-pool scalars to a Pools slice so nat mode can emit both the transit pool and an optional public wan pool. nat mode now accepts --external-pool/--external-source (plus --external-bind-bridge/--gateway-ip when a public pool is requested), validated by the shared resolvePublicPoolFlags helper also used by pool mode. Transit pool always renders first so the IGW allocator picks it. Formation wire format unchanged (nat mode is single-node only). * feat(daemon): enable EIP service and auto-assign in nat mode with public pool External IPAM (and with it the real EIP service, RunInstances public IP auto-assign, and MapPublicIpOnLaunch on default subnets) now activates whenever public pools exist: pool mode as before, plus nat mode when a wan pool rides alongside the transit segment. The transit pool is filtered out of IPAM — its addresses are gateway-LRP plumbing, never allocatable EIPs. Transit-only nat configs keep the disabled EIP stub. * feat(host): per-EIP ingress primitives for routed-NAT mode DetectUplinkFor parses ip route get to find the interface and source IP facing the pool gateway (re-run per ensure: WiFi/cellular uplinks move). EnsureEIPIngress steers an EIP into OVN with a /32 route via the VPC gateway LRP transit IP (src-hinted so host-local traffic still DNATs), answers ARP for the EIP with a proxy neighbor entry (L3 only, same MAC, WiFi-safe), sends gratuitous ARP, and adds per-EIP FORWARD accepts for DROP-policy hosts. RemoveEIPIngress mirrors; missing state tolerated. * feat(policy,vpcd): host EIP binder option on NATManager WithHostEIPBinder injects routed-mode host plumbing hooks. AddEIP binds after priming on both the fresh-add and idempotent-skip paths (host routes and proxy-ARP are volatile even when the OVN row survives, so reconcile re-ensures them after reboot); DeleteEIP unbinds best-effort. The next hop comes from the new gatewayPortIP helper reading the gateway LRP's stamped spinifex:gateway_ip (Networks fallback), with the ext-ID key now an exported policy const shared with the external package. vpcd selects the IGW pool by name instead of index — with two pools in nat mode the gateway allocator must stay on the transit pool — and wires the binder over host.EnsureEIPIngress/RemoveEIPIngress when a public pool is present. EnsureEIPIngress gains an uplink hint so dhcp-sourced pools (gateway unknown until lease) proxy-ARP on their bind bridge. * feat(dhcp): interface-MAC lease variant with MAC-keyed-router detection dhcp_mac = "derived" (default) | "interface" on external pools. The interface variant leases with the bind interface's own MAC — WiFi/WWAN uplinks drop frames with foreign source MACs, so derived chaddr MACs never complete DORA there. Option 61 stays the lease discriminator. UseIfaceMAC threads AllocateRequest → NATS wire → nclient4 → lease and persists through KV so restart re-acquires repeat it. Routers that key leases on MAC and ignore client-id would hand every lease the same IP; the manager detects an ACK matching the interface's own address or another client-id's live lease, releases the colliding lease, and hard-errors advising a static range instead. admin init auto-writes dhcp_mac="interface" for nat-mode public dhcp pools bound to non-bridgeable uplinks (wlan/wwan/ppp). * test(natuplink)+docs: Tier 2 EIP ingress e2e phases and public-pool docs The natuplink suite now detects a public (non-transit) pool in spinifex.toml and switches lanes: Tier-1-only configs keep the EIP-disabled and no-public-IP assertions; public-pool configs assert the EIP surface is enabled, the default subnet has MapPublicIpOnLaunch=true, instances auto-assign public IPs, and a new Phase 9 exercises the full EIP ingress lifecycle — host /32 route via the gateway LRP, proxy-ARP on the uplink, per-EIP FORWARD accepts, exempt-stamped dnat_and_snat, TCP handshake to the EIP, reconcile replay across a vpcd restart, and teardown on disassociate. Docs: vpc-networking README gains a public-pool section for routed-NAT nodes (init flags, dhcp_mac=interface behaviour, host-to-EIP caveat) and an updated mode comparison; COMMANDS.md notes nat-mode EIP support behind a public pool. * fix(setup): whitelist iptables, neigh sysctl, and arping for spinifex-vpcd Routed-NAT mode shells out to iptables for the transit masquerade and per-EIP FORWARD accepts, tunes proxy_delay, and sends gratuitous ARP for host-delivered EIPs. Without these sudoers entries vpcd crash-loops with "command not allowed" on nat-mode nodes. * fix(ovn): scope DeleteStaticRoute prefix match to the target router Every VPC router carries a 0.0.0.0/0 static route, so an unscoped cache match could grab another router's row and fail with a referential integrity violation, wedging IGW attach on multi-VPC nodes. Match only rows referenced by the target router, mirroring FindStaticRoute. Mock updated to the same semantics, with a regression test covering drift replacement across two routers. * fix(reconcile): always replay AttachIGW so host ingress state is re-ensured applyIGWs skipped AttachIGW whenever the gateway switch port existed in actual state, so the already-attached re-ensure path never ran and routed-NAT host ingress routes lost on reboot were never reinstalled. AttachIGW is idempotent; run it unconditionally. * fix(vpcd): resolve duplicate-CIDR host ingress route collisions, bootstrap VPC wins Every account's default VPC shares 172.31.0.0/16, so Tier-1 host routes collide on the single host route table and the last IGW attach silently stole the route (route replace). Pass vpcID and the gateway LRP IP through RoutedIngressHooks; the bootstrap VPC always installs its route, other VPCs only install when the CIDR is free and only remove a route their own gateway IP holds. Adds host.VPCIngressRouteVia to read the current route holder. * ci(e2e): add nightly cell 19 for routed-NAT single-node suite Cell 19 bootstraps with --external-mode=nat plus the CI static pool as the public wan pool and runs the natuplink suite, covering the Tier-1 transit datapath and Tier-2 EIP ingress. The run step exits 0 when natuplink.test is absent from the tests tar so scheduled runs against branches predating the suite stay green. * fix(admin): nat-mode init summary reflects configured public pool The summary printed 'outbound-only — no public IPs/EIPs' even when --external-pool/--external-source configured a public wan pool. Print the pool range (or dhcp bind) and note EIPs are enabled. * fix(eip,vpc): thread ctx through disabled EIP stub and NAT call sites Reconcile the routed-NAT branch with dev's ctx-first service APIs after rebase: DisabledEIPService and its tests take ctx to satisfy the EIPService interface, the vm_adapters public-IP resolver asserts the ctx-signed AssociatedPublicIPForInstance, and the default-subnet mapping test threads ctx into DescribeSubnets. |
||
|
|
e11437cec9 | feat(imds): per-tap responder datapath (#408) | ||
|
|
c22a6f4ffc |
fix: install chrony on host via curl|bash setup path (#366)
The host clock needs an NTP daemon; without one it drifts and SigV4 request signatures fall outside the skew window, kicking the web console back to /login. Mirrors the ISO rootfs (iso-builder packages.list) so both host-install paths ship the same software. Guest VMs track the host via kvm-clock. Bug: mulga-siv-335 |
||
|
|
f6f3956952 |
feat: enable viperblock at-rest encryption by default on fresh installs (#323)
* feat: enable viperblock at-rest encryption by default on fresh installs
Fresh installs left nodes.<node>.viperblock.encryption_key_file empty, which
viperblockd treats as legacy cleartext mode. The encryption machinery existed
but the install path never generated a key or set the field.
Provision a cluster-wide viperblock master key in all three fresh-install
flows and render its path into spinifex.toml:
- admin init (single node): generate the key locally.
- admin init --multi-node (leader): generate once, save locally, and
distribute via the formation server (mirrors IAM master key distribution).
- admin join (joiner): receive the shared key from the leader rather than
minting its own, so volumes sealed on any node open everywhere. Lenient on
absence — an older leader returns no key, so the joiner warns and stays
cleartext instead of failing the join.
The key file is omitted from the template when unset, so upgrades with no
existing key keep running cleartext.
* fix: make viperblock encryption key group-readable for both readers
The key is loaded by two services per node — viperblockd (spinifex-viperblock)
and the awsgw EC2 handlers (spinifex-gw), both in the spinifex group — so it
must be group-readable, not owner-only like the per-node predastore key.
The previous commit generated the key but never registered its path with the
deployment ownership machinery, leaving /etc/spinifex/viperblock as root:root
0700 (non-traversable) and the key as root:root 0600. The daemon failed at
startup with "stat ... permission denied".
Mirror master.key: setup.sh creates /etc/spinifex/viperblock (0750), and
SetServiceOwnership chowns the dir to spinifex-viperblock and promotes the key
to root:spinifex 0640.
* fix: read viperblock config.json through StateBody for encrypted volumes
The metadata layer parsed config.json with json.Unmarshal/NewDecoder directly,
which fails on encrypted volumes/AMIs now that viperblock wraps VBState in a
valid-JSON envelope ({"v":1,"payload":...,"authtag":...}). DescribeImages
silently skipped encrypted AMIs (count=0 → "no AMIs available"), bricking the
whole launch path.
Route every config.json read through viperblock.StateBody, which unwraps the
envelope (no key needed — the metadata is authenticated, not encrypted) and is
a no-op for unencrypted volumes:
- image: DescribeImages, getVolumeConfig, amiNameExists, GetAMIConfig
- volume: getVolumeConfigAndEncryption, and mergeVolumeConfig (so the
refuse-to-merge-encrypted guard sees the real VBState instead of clobbering
the envelope with a tag-less blob)
- admin: readAMIConfig, readVolumeConfig
|
||
|
|
2ea3e22db6 |
feat(systemd): cgroup-confine spinifex to a resource-limited slice + host swap (#324)
* feat(systemd): bound spinifex to a resource-limited slice Add a spinifex.slice parent ceiling (MemoryHigh=80%, MemoryMax=90%, MemorySwapMax=0) with a spinifex-system.slice child holding the seven control/infra services, so a runaway hits the slice instead of the host. A system.slice drop-in (MemoryMin=1G, CPUWeight=300) reserves RAM and CPU for sshd/journald/the operator, keeping the box reachable when spinifex is maxed. The drop-in is generated in setup.sh install_systemd() rather than shipped as a staged file, since the packaging globs flatten the systemd/ dir; this mirrors the existing sshd-keygen drop-in pattern. The two .slice files flow through every staging path unchanged. Within the single effective cgroup, a slice MemoryMax OOM picks the highest oom_score victim — guest QEMU (+500) before any service (-500) — so a slice OOM degrades by killing one guest while the daemon, storage tier, NATS, and the host all survive. * feat(setup): provision 8G host swapfile + vm.swappiness=10 Add a setup_swap stage that creates an 8G /swapfile, enables it, persists it to fstab, and writes vm.swappiness=10 so the kernel only swaps under real pressure. Backs spinifex.slice MemorySwapMax so the slice can spill to swap for graceful degradation instead of OOMing a guest. Idempotent; skipped under ISO_BUILD (firstboot provisions swap on ISO hosts). Reverses the prior swap=0 assumption. |
||
|
|
41f840ee85 |
fix(setup): grant spinifex-vpcd sudo for ovn-appctl (siv-167)
The W2 inject-garp fix landed in
|
||
|
|
9d8597317a |
Feat/mig capable (#271)
* feat(gpu): add NVIDIA MIG multi-instance GPU support
Partitions MIG-capable GPUs (A100, A30, H100) into isolated slices exposed
as mdev devices instead of whole-GPU VFIO passthrough. VMs attach via
-device vfio-pci,sysfsdev=<mdev-path> using the GPUAttachment discriminated
union (PCIAddress for whole-GPU, MdevPath for MIG).
Key changes:
- gpu: new MIGProfile/MIGInstance types, IsMIGCapable model map, mig.go ops
(EnableMIGMode, DisableMIGMode, CreateInstances, ListInstances,
DestroyAllInstances, enrichMdevPaths)
- gpu.Manager: Claim() returns (*GPUDevice, *MIGInstance, error); AddMIGInstances,
ReclaimByMdev for restart recovery; MarkMIGFailed per-slice
- daemon: buildGPUPool helper partitions devices into whole-GPU vs MIG pools;
MIGProfile config field selects profile per node or per GPU override
- vm.VM: GPUAttachments []gpu.GPUAttachment replaces GPUPCIAddresses []string
- admin CLI: spx admin gpu mig status/enable/disable subcommands with
admin.SetMIGProfile for spinifex.toml writes
- docs: COMMANDS.md updated with three new MIG management command rows
* test(gpu): unit tests for MIG parsers and pool manager
Cover all pure parsing functions (parseMIGMemory, isCapacityExhaustedError,
extractProfileFields/GIFields, parseMIGProfiles, parseMIGInstances,
parseCreatedGIID/CIID) with realistic nvidia-smi fixture output.
Manager MIG tests cover AddMIGInstances, Claim/Release on mdev-backed entries,
MarkMIGFailed, ReclaimByMdev, and interaction with whole-GPU MarkFailed — all
using fake mdev directories in t.TempDir() so no GPU hardware is required.
* feat(gpu): dynamic MIG profile-per-request with on-demand GI/CI lifecycle
Replaces static config-driven MIG pre-carving with a dynamic model where
the MIG profile is specified per RunInstances call via mig.<profile>
instance type names (e.g. mig.1g.10gb) that mirror nvidia-smi nomenclature
directly.
- Manager.Claim(instanceID, profileName): fast path claims a pre-carved
slice; slow path dequeues a free MIG GPU, releases the lock, calls
nvidia-smi mig -cgi/-cci to carve all slices, then reclaims the lock to
commit and return the first slice
- Manager.Release: last release on a dynamically-carved GPU calls
DestroyAllInstances and returns the GPU to freeMIGGPUs, allowing a
different profile on the next claim
- AddMIGGPU(dev): registers a fresh MIG GPU for dynamic allocation;
AddMIGInstances (restart recovery) keeps its no-destroy semantics
- GenerateMIGTypes: produces mig.<profile> InstanceTypeInfo entries from
gpu.ListProfiles at daemon startup; IsMIGType/MIGProfileFromType let
callers inspect these names
- buildGPUPool: calls ListInstances for recovery, AddMIGGPU for fresh
GPUs, ListProfiles to collect MIG profile specs for type generation;
removes setupMIGInstances and migProfileForDevice
- GPUClaimer.Claim gains profileName param; daemonGPUClaimer, service_impl
call sites, and fakeGPUClaimer all updated
* fix(gpu): correct mdev parent detection and make --profile optional for mig enable
enrichMdevPaths was using os.Readlink on "parent_bus_0" (a non-existent
sysfs attribute) and then on ".." (a directory, not a symlink) — both
would fail on real NVIDIA hardware, breaking CreateInstances and
ListInstances on daemon restart recovery. Fix: read the mdev UUID's own
symlink target, which always encodes the parent GPU's PCI address in its
path (e.g. .../0000:01:00.0/<uuid>).
Make basePath injectable in enrichMdevPaths so the fix is covered by a
new set of unit tests using temp-dir symlinks (TestEnrichMdevPaths_*).
Remove the MarkFlagRequired("profile") from "spx admin gpu mig enable":
Phase 2 is fully dynamic — the daemon carves slices on demand at
RunInstances time. Without --profile, the command just enables MIG mode
and destroys any pre-carved slices so the daemon starts with a free GPU.
With --profile, behaviour is unchanged (pre-carve a static pool).
* chore: writeups for smci and arcee
* test: add coverage for MIG exec, manager slow-path, instancetypes and admin
- Add mig_exec_test.go with fake nvidia-smi harness covering Enable/Disable MIGMode,
IsMIGModeEnabled, DestroyAllInstances, ListProfiles, CreateInstances, ListInstances
- Extend manager_mig_test.go with slow-path Claim/Release tests using fake nvidia-smi
- Add generate_test.go coverage for IsMIGType, MIGProfileFromType, GenerateMIGTypes
- Add admin_test.go coverage for SetMIGProfile (create, update, idempotent, error paths)
- Make mdevBasePath a var to allow sysfs injection in tests
- Add json tags to GPUAttachment fields to satisfy musttag linter
Diff coverage: 75.6% (threshold: 60%).
* fixed gpu passthrough doc
* Revert "fixed gpu passthrough doc"
This reverts commit
|
||
|
|
fd3dc6b680 |
feat(network): ADR-0006 layer redesign + IPsec/OVN hardening (#255)
* refactor(vpcd): remove macvlan bridge mode
Macvlan was a single-NIC SSH-safe hack that predated veth mode and was
never selected by any active config path. Deletion is Phase 0 item 1 of
the network layer redesign (mulga-siv-125.1).
Removed:
- BridgeModeMacvlan const + setMacvlanMAC + ifaceIsMacvlan probe
- Macvlan MAC alignment block in launchService (only fired on dead path)
- Macvlan branch in detectBridgeMode + matching tests
- Macvlan duplicates of IGW/AddNAT centralized-NAT tests (veth versions
already cover the same path)
- --macvlan flag + macvlan case branch in setup-ovn.sh
Refactored:
- useCentralizedNAT() now == BridgeModeVeth (was != BridgeModeDirect);
verifyBridgeMode already rejects empty/unknown at startup
- Three IGW-pool tests now explicitly WithBridgeMode(BridgeModeVeth)
(previously relied on empty-mode defaulting to centralized)
Kept intentionally:
- Deprecation notes in docs/compute/vpc-networking/README.md
- Legacy macvlan-interface cleanup in reset-dev-env.sh + ansible
teardown role (migration for operator systems with stale spx-ext-*
interfaces from pre-veth installs)
* feat(vpcd): resolve external CIDR at startup with bounded retry
Block service start until the WAN bridge has an IPv4 address, with a 30s
retry window. Phase 0 item 2 of the network layer redesign
(mulga-siv-125.1). Guards the boot race where vpcd starts before
systemd-networkd finishes DHCP on br-wan, or before netplan applies a
static config.
Skipped when ExternalMode is empty (overlay-only deployments).
Forward-compatible with ADR-0006: the new resolveExternalCIDR /
externalCIDRFromBridge helpers become the backing implementation of
HostWiring.ExternalCIDR() once the network/host package lands in Phase 1.
Until then the resolved value is only used to fail-start on missing
uplink.
* fix(vpcd): cover external CIDR startup paths
Extract launchService's CIDR-resolve block to ensureExternalCIDRReady
helper so it's unit-testable, and add direct tests for
externalCIDRFromBridge (loopback + unknown-interface) to exercise the
original literal body. Closes the diff-coverage gap on Phase 0 commit
15b564d which left these paths unreachable from unit tests.
* refactor(network/ovn): extract L1 OVN client to network/ovn package
Move OVNClient interface, LiveOVNClient, ACLSpec, ErrNATNotFound and
namedUUID helper from services/vpcd to a new spinifex/network/ovn
package. The mock relocates to spinifex/network/ovn/mock as a
sub-package. Storage fields on the mock become exported so vpcd tests
can continue to seed/inspect state across the new package boundary.
services/vpcd retains thin type-alias and var-alias shims so existing
callers compile unchanged; Phase 2 removes those shims as vpcd is torn
down.
Adds -coverpkg=./spinifex/... to test-cover so cross-package test
exercise of mock methods continues to count toward coverage now that
the mock lives outside vpcd.
First sub-step of Phase 1 of docs/development/feature/spinifex-network-redesign.md
(bead mulga-siv-125.2). Pure refactor; no functional change. All
existing tests pass; preflight green.
* feat(network/topology): TopologyManager interface + vpcd adapter
Add spinifex/network/topology with Manager interface, VPC/Subnet/Port
specs, and OVN object naming helpers covering the L2 stable contract
(§7 of the redesign plan). Phase 1 keeps existing in-tree OVN names
(rtr-, ext-port-, sg_) and notes the §7.3 targets for a later
reconciliation migration.
TopologyHandler in services/vpcd grows EnsureVPC / DeleteVPC /
EnsureSubnet / DeleteSubnet / EnsurePort / DeletePort /
SetPortSecurityGroups methods that mirror the corresponding NATS
handlers' OVN ops with Spec inputs instead of nats.Msg envelopes,
satisfying topology.Manager via a compile-time check. Existing handlers
are unchanged; the duplication is short-lived (Phase 2 collapses them).
Smoke tests in topology_manager_test.go cover the idempotent create
path, delete cascade, and declarative SG membership move. Deliverable:
TopologyManager.EnsureVPC/Subnet/Port callable; all existing tests
green.
Second sub-step of Phase 1 of docs/development/feature/spinifex-network-redesign.md
(bead mulga-siv-125.2).
* feat(network/host): L0 HostWiring interface + physical/veth impls
Phase 1 deliverable for mulga-siv-125.2. Introduces network/host (L0 of
ADR-0006): UplinkMode enum, Wiring interface, and Physical/Veth
implementations with injectable Runner + InterfaceReader for testability.
Not yet wired into daemon/vpcd — Phase 2 replaces daemon.SetupComputeNode
and vpcd's resolveExternalCIDR with calls through this package.
* feat(network/policy): L3 SecurityGroup/NAT/Route managers
Introduce network/policy as the data-plane policy layer (ADR-0006 L3).
Three managers, all backed by network/ovn:
- SecurityGroupManager: clear+add ACL replacement on an existing port
group; port group lifecycle stays with L2 (topology.Manager).
- NATManager: bound to one NATMode at construction (derived from
host.UplinkMode). Distributed sets logical_port/external_mac on EIP
dnat_and_snat rules; centralised leaves them unset. Per-EIP, NAT GW,
and IGW-default SNAT entrypoints; all deletes idempotent.
- RouteManager: AddStaticRoute is read-then-decide so retries no longer
duplicate rows (closing the long-standing non-idempotency bug in
vpcd/topology.go's IGW default-route path).
ACL priority constants and infrastructure ACL builders move from
vpcd/{security,acl}.go into policy/acl.go with their semantics preserved
(default-deny 900/800 logged, DHCP-allow 1050, tenant 1000). No vpcd
wiring changes here — additive only; the reconciler (bead .3.2) and
network/external (bead .3.4) will consume these managers.
bead: mulga-siv-125.3.1
* feat(network/external): L5 IGW/EIP/NATGW managers
Pure additive — new package, no topology.Manager changes, no rewiring of
existing vpcd handlers. IGWManager builds the external switch + localnet +
gateway LRP + default route + chassis HA, with a flows barrier callers can
inject (production: ovn-nbctl --wait=hv sync). EIP/NATGW are thin L5
wrappers over policy.NATManager. GatewayIPAllocator interface lets the
DHCP-backed allocator stay in vpcd until the DHCP-mgr removal bead lands;
LinkLocalAllocator + StaticRangeAllocator ship here.
* feat(network/reconcile): L6 intent-actual reconciler replaces 5-pass startup
Build spinifex/spinifex/network/reconcile/ package per Phase 2.2 of the
network layer redesign. Reads desired state from NATS KV filtered by
vpc.AZ (with legacy empty-AZ matches-all rule), scans actual state from
OVN NB DB, diffs and applies with VPC → Subnet → Port → SG → IGW →
EIP/NATGW topological ordering.
Atomic port-group join via CreateLogicalSwitchPortInGroups closes the
racy gap the legacy scanENIPortMembership pass used to revive 30s later.
A 5-minute drift goroutine (leader-gated via JetStream KV CAS) replaces
the old 30s ReconcileSGsLoop.
Adds AZ field to VPCRecord stamped at create time. Empty AZ on pre-Phase
2.2 records matches every local AZ, so no migration pass is required.
Replaces and removes the 5-pass startup sequence in services/vpcd:
- Reconcile + ReconcileFromKV
- ReconcileSGsOnce + ReconcileSGsLoop
- RetrofitAllExternalLocalnetOptions
- RetrofitAllGatewayPortNetworks
IGW fresh-create continues to flow through the legacy NATS handler path
(handleIGWAttach) so the dhcpManager wiring stays intact until Phase
2.3; the reconciler only rebinds gateway-chassis on existing IGW
topology.
Closes mulga-siv-125.3.2.
* refactor(network/topology): promote live Manager impl to network/topology
Move the topology.Manager implementation out of services/vpcd/topology_manager.go
into network/topology/manager_live.go as a standalone liveManager constructed
via NewLiveManager(ovn.Client, opts...). Inputs that varied per-handler
(DNS server resolution from the external pool) are now passed as functional
options (WithDNSServer).
TopologyHandler still satisfies topology.Manager but its methods delegate
to a cached liveManager. The shim stays until the rest of mulga-siv-129
routes NATS subscribers through topology.Manager directly.
Also exports SubnetGatewayCIDR + FormatDNSServerList from network/topology
so the reconciler in network/reconcile can share helpers with the live
manager (audit pass to follow per plan §6).
Test cases ported one-for-one from services/vpcd/topology_manager_test.go
to network/topology/manager_live_test.go; the vpcd-side test file is
deleted. New WithDNSServer test asserts the option propagates into
DHCPOptions rows.
Refs mulga-siv-129 (Phase 2.6 vpcd subscriber migration, Slice 1 of N).
* refactor(vpcd): collapse SG subscribers onto network/{topology,policy} managers
Phase 2.6 / mulga-siv-129 slice 2. Rewrites the vpc.create-sg /
vpc.update-sg / vpc.delete-sg NATS subscribers in services/vpcd as
thin wrappers over topology.Manager (port group lifecycle) and
policy.SecurityGroupManager (ACL programming). Deletes the ~1000
lines of duplicated ACL builder and provisioning logic — its
authoritative copy lives in network/policy.
Surface additions:
- ovn.ErrPortGroupNotFound sentinel; mock + live GetPortGroup wrap
not-found via fmt.Errorf("%w: ...") so callers can use errors.Is.
- topology.Manager grows EnsureSGPortGroup / DeleteSGPortGroup
(resolves the apply.go TODO from §2.1 of the redesign plan).
liveManager implements them with GetPortGroup-then-Create /
GetPortGroup-then-Clear+Delete idempotency.
Behaviour delta: the old provisionSG rolled back the OVN port group
on AddACLs failure ("all-or-nothing"). The new path lets the port
group survive and relies on network/reconcile to retry EnsureSG on
its next sweep. The all-or-nothing fail-fast test cases are dropped;
ACL emission semantics are covered by network/policy/sg_test.go.
* refactor(vpcd): migrate VPC/Subnet/ENI subscribers to topology.Manager
Phase 2.6 / mulga-siv-129 slice 3. Rewrites vpc.create / vpc.delete /
vpc.create-subnet / vpc.delete-subnet / vpc.create-port /
vpc.delete-port / vpc.update-port-sgs NATS subscribers as thin
wrappers (≤30 lines each) over topology.Manager. Subscriber bodies
now: parse event → translate to spec → delegate to manager.
Deletes:
- vpcd.subnetGateway (and helpers_test.go + topology_test.go's
TestSubnetGateway block); parity coverage lives in
network/topology.TestSubnetGatewayCIDR.
- vpcd.reconcilePortSGs (the live manager already exposes the same
diff-then-transact via reconcilePortSGs on the L2 side).
- vpcd.TopologyHandler.dnsServer; lmDNSServer (passed via
topology.WithDNSServer to the live manager) is the live path.
Behaviour delta: handlers now strict-parse PrivateIpAddress /
MacAddress / CidrBlock at the NATS boundary and reject malformed
payloads instead of degrading to "no DHCP options". The reconciler
guarantees that field validity is upheld upstream of the publish.
* refactor(network/reconcile): drive SG port groups via topology.Manager
applySGs now calls topology.Manager.EnsureSGPortGroup /
DeleteSGPortGroupByName instead of reaching directly into the OVN client.
Reconcile.Config gains a Topology field (required); the production caller
in services/vpcd passes the TopologyHandler shim, the reconcile package
tests construct a fresh topology.NewLiveManager bound to the mock OVN
client.
DeleteSGPortGroupByName is added to the topology.Manager interface for the
reconciler's orphan-removal path, which iterates raw OVN port-group names
without a groupID round-trip. The existing DeleteSGPortGroup(groupID)
delegates to it.
Resolves the TODO at apply.go:137 carried over from slice 2 of
mulga-siv-129.
* feat(network/policy): add FlowsBarrier option to NATManager
NATManager.AddEIP needs to block on `ovn-nbctl --wait=hv sync` after
writing the dnat_and_snat row so the NATS reply only returns once every
chassis has the rewrite flow. The legacy vpc.add-nat handler does this at
the tail of handleAddNAT; the manager has lacked it since slice 2.1.
NewNATManager grows a functional-options tail (Option / WithFlowsBarrier).
Defaults to a no-op for tests; production wiring in services/vpcd passes
waitForFlowsHV. AddEIP now invokes the barrier after AddNAT, logging at
warn level on failure to match the legacy handler's _ = waitForFlowsHV()
swallowing semantics.
Pre-work for slice 4 of mulga-siv-129 — without the barrier the NAT EIP
subscriber migration would lose the post-write flow-install gate.
* refactor(vpcd): migrate NAT GW subscribers to policy.NATManager
handleAddNATGateway / handleDeleteNATGateway now decode the NATS event
and delegate to policy.NATManager.{AddNATGateway,DeleteNATGateway}. The
manager carries identical OVN logic — same snat type, same ExternalIDs
(spinifex:vpc_id + spinifex:nat_gateway_id) — so existing
TestTopologyHandler_AddNATGateway / DeleteNATGateway suites stay green.
Lazy-constructed NATManager added on TopologyHandler (natmOnce). Mode is
derived from the bridge mode (veth → centralized, direct → distributed)
and the FlowsBarrier is bound to waitForFlowsHV for parity with the
legacy EIP path's tail barrier (used by the next slice, vpc.add-nat).
Slice 4 of mulga-siv-129, sub-step b.
* refactor(vpcd): migrate EIP NAT subscribers to policy.NATManager
handleAddNAT / handleDeleteNAT now decode the NATS event and delegate to
policy.NATManager.{AddEIP,DeleteEIP}. The behavioural contract is
preserved end-to-end:
- Idempotency-skip on a matching dnat_and_snat row (same VPC + LogicalIP,
plus MAC + LogicalPort under distributed NAT) moves into AddEIP so
duplicate vpc.add-nat publishes never tear down the rule the previous
invocation just installed (mulga-siv-124).
- Stale-rule cleanup across every router stays in AddEIP.
- Post-write waitForFlowsHV barrier is now driven by the manager via the
FlowsBarrier option wired in services/vpcd (slice 4a).
- DeleteEIP returns nil on ErrNATNotFound, matching the handler's
fire-and-forget "already absent = success" semantic.
The vpcd "errors" import drops out with the inline error-comparison.
Slice 4 of mulga-siv-129, sub-step c.
* refactor(vpcd): migrate IGW subscribers to external.IGWManager (partial)
handleIGWAttach now branches at decode time:
- Centralised NAT + DHCP-sourced pool keeps using attachIGWLegacy because
the gateway-LRP IP comes from vpc.dhcp.acquire, and that DHCP client is
the vpcd-local manager that bead mulga-siv-125.3.3 will retire.
- All other shapes (distributed NAT, static-range pool, no pool)
delegate to external.IGWManager.AttachIGW. The manager mirrors every
step the legacy handler ran — external switch + localnet port +
gateway LRP + switch-side router peer + default route + chassis HA +
waitForFlowsHV tail barrier — so observable behaviour is unchanged.
handleIGWDetach drops its inline OVN walk entirely; both paths exit
through external.IGWManager.DetachIGW followed by releaseGatewayLRPLease.
The lease release stays in vpcd because the upstream client lives in
services/vpcd/dhcp; calling it after every detach is safe because the
upstream server expires unknown leases on its own.
Lazy-constructed IGWManager added on TopologyHandler (igwmOnce). Pool,
allocator (StaticRangeAllocator), chassis, NAT mode, NAT manager, route
manager, and FlowsBarrier are all derived from the existing
TopologyHandler state.
The DHCP-coupled legacy branch retains its full inline OVN logic; it
will disappear in slice-after-125.3.3 follow-on. Slice 4 of
mulga-siv-129, sub-step d.
* feat(ec2/instance): honor AssociatePublicIpAddress per-NIC override
RunInstances --network-interfaces "AssociatePublicIpAddress=true|false"
was silently ignored, only subnet.MapPublicIpOnLaunch gated public IP
assignment. AWS contract is per-NIC override wins.
Extend TestPrepareRunInstances_PublicIPAutoAssigned to table-driven
3 cases: subnet true no-override, subnet false override true, subnet
true override false.
* refactor(config): drop upstream-DHCP config surface (static WAN pool only)
Hard-error in LoadConfig on legacy keys: [network] external_dhcp,
[nodes.<n>.vpcd] dhcp_bind_bridge, and [[network.external_pools]]
source = "dhcp". Add pool range validation (must fit inside the
gateway/prefix_len CIDR; per-cluster non-overlap).
Strip ExternalDHCP from config.NetworkConfig + formation.NetworkConfig
+ admin.ConfigSettings, and DhcpBindBridge from config.VPCDConfig +
admin.ConfigSettings + vpcd.Config. vpcd.ExternalPoolConfig.IsDHCP()
short-circuits to false; the field and downstream DHCP branches in
external_ipam / topology.go remain for Slice C to delete together with
dhcp_manager.
cmd/spinifex/cmd/admin.go: drop useExternalDHCP path and the
detectedDhcpBindBridge helper; require --external-pool when
--external-mode=pool; auto-detect default no longer infers source=dhcp.
service.go's wan_bridge legacy-key rejection now advises removing the
key entirely (vpcd auto-detects br-wan), not renaming to
dhcp_bind_bridge.
Two topology_test cases that exercise the DHCP gateway-LRP path are
skipped — Slice C deletes attachIGWLegacy and these tests together.
* refactor(vpcd): delete dhcp_manager + DHCP gateway-LRP path (Slice C)
Removes upstream-DHCP-client gateway-LRP allocation in favor of static
WAN-pool allocation (StaticRangeAllocator). Part of bead mulga-siv-125.3.3.
- delete services/vpcd/dhcp_manager.go + dhcp/ subpackage (~865 lines)
- delete allocateGatewayLRPIPViaDHCP + releaseGatewayLRPLease paths
- drop ExternalPoolConfig.Source + DhcpBindBridge + IsDHCP() fields
- drop ExternalIPAllocation lease fields (Expiry/ServerID/HWAddr) and
ExternalIPAMRecord.Source
- drop NewExternalIPAM nc *nats.Conn argument; update all 4 call sites
- rename verifyBridgeMode local dhcpBindBridge -> wanBridge; update error
strings and tests
Slice D (delete attachIGWLegacy + dispatcher) intentionally deferred.
* refactor(vpcd): delete attachIGWLegacy + IsDHCP stub (Slice D)
Closes mulga-siv-129 slice 4d. Part of bead mulga-siv-125.3.3.
handleIGWAttach now unconditionally delegates to external.IGWManager.
attachIGWLegacy (~207 lines, ~5 OVN write steps + chassis scheduling)
deleted along with its dispatcher branch in handleIGWAttach. The
ExternalPoolConfig.IsDHCP() dead stub is gone.
No code paths or NATS subjects regress: the static-pool / distributed
branches were already going through external.IGWManager since Slice 4d
(6719dc3).
* feat(ipam): Purpose field on every IPAM record (Slice B)
Part of bead mulga-siv-125.3.3.
Adds a Purpose enum (handlers/ec2/vpc/purpose.go) tagging every IP
allocation with its semantic role (eni-primary, eni-public, eip,
igw-lrp, natgw-external, …) so multi-VPC clusters can reclaim/audit
by (owner, purpose).
External IPAM (spinifex-external-ipam, v1→v2):
- ExternalIPAllocation.Type → .Purpose; legacy values mapped via
LegacyExternalTypeToPurpose (gateway→igw-lrp, auto_assign→eni-public,
elastic_ip→eip). Unknown legacy values warn and become "unknown".
- AllocateIP / AllocateFromPool / allocateFromPool param rename
allocType→purpose. All call sites pass Purpose* constants.
- migrate/002_external_ipam_purpose.go: idempotent CAS-retry migration
with v1/v2-union record shape so partial migrations resume cleanly.
Internal IPAM (spinifex-vpc-ipam, v1→v2):
- IPAMRecord.Allocated []string → []IPEntry{IP, Purpose, OwnerID}.
- AllocateIP gains purpose+ownerID args; ReleaseIP unchanged (still
keyed on IP).
- AllocatedIPs returns []IPEntry.
- eni.go reorders eniId generation before AllocateIP so the owning
resource ID lands on the new entry.
- migrate/003_ipam_purpose.go: cross-bucket backfill that reads the
ENI bucket via the new RunKVWithJetStream path. Orphaned IPs
(no owning ENI) warn and become Purpose=unknown.
Migrate framework:
- KVContext gains an optional JetStream field; new
Registry.RunKVWithJetStream method threads it through. RunKV
signature unchanged — all other callers are unaffected.
Tests:
- ipam_test.go: AllocateIP signature updates; AllocatedIPs now asserts
IP / Purpose / OwnerID on the returned entries.
- external_ipam_test.go: replaces "auto_assign"/"elastic_ip" literals
with PurposeENIPublic/PurposeEIP and asserts alloc.Purpose.
- migrate/002 + 003 tests: schema-detect, idempotent rerun,
no-JetStream fallback, empty bucket.
* refactor(daemon): tombstone obsolete spinifex-dhcp-leases KV bucket
The dhcp_manager removed in Phase 2.3 (bead mulga-siv-125.3.3) owned the
spinifex-dhcp-leases KV bucket. The migrate framework only handles
per-bucket schema version bumps, not bucket deletion, so the obsolete
bucket would linger on upgraded clusters.
Add a one-shot tombstone after initJetStream that deletes the bucket if
present. DeleteKVBucketIfExists treats ErrBucketNotFound and
ErrStreamNotFound as success, so the call is idempotent across restarts.
* feat(config): add network.ipsec_enabled cluster flag (default true)
Add IPSecEnabled to NetworkConfig in both the cluster TOML schema and
the formation handshake payload. Default true so AWS-parity intra-AZ
encryption is on by default. Operators can flip false in
[network] for trusted single-rack lab topologies.
Phase 2.5 (bead mulga-siv-125.3.5) consumes the flag from admin init
(strongSwan provisioning), formation server (propagates to joiners),
and daemon startup (ovs-vsctl ipsec_encapsulation toggle).
* feat(admin): IPsec peer cert generator signed by cluster CA
Add GenerateIPSecPeerCert + IPSecCertPaths in spinifex/admin so admin
init (and the future admin add-node path) can issue per-node IKEv2 peer
credentials signed by the existing cluster CA. The cert carries
id-kp-ipsecIKE (RFC 4945) so strongSwan accepts it as an IKEv2 peer
credential when ovs-monitor-ipsec materialises tunnel configs.
Cluster CA is reused directly — no intermediate strongSwan PKI today;
when intermediate CAs land that becomes a separate workstream.
The cert/key pair lives under {configDir}/ipsec/peer.{pem,key}; the
daemon points OVS Open_vSwitch.other_config (certificate, private_key,
ca_cert) at these paths when network.ipsec_enabled is true.
* feat(admin): wire IPsec peer cert into admin init + join paths
Add --ipsec bool flag (default true) on adminInitCmd. Single-node init
and the multi-node leader path both emit an IPsec peer cert after the
existing CA+server-cert generation. The multi-node formation server
propagates the IPSecEnabled flag to joining nodes via NetworkConfig;
admin join honours it and emits its own peer cert during the same
cert-issuance step that already produces the server cert.
spinifex.toml template gains an unconditional [network] block carrying
ipsec_enabled so the value is visible to operators on every install
regardless of whether external networking is configured. The daemon
reads it via cluster config (NetworkConfig.IPSecEnabled).
Bead mulga-siv-125.3.5.
* build: install openvswitch-ipsec for OVN native IPsec
openvswitch-ipsec provides ovs-monitor-ipsec, which reads the
Open_vSwitch.other_config cert/key/CA pointers and materialises
strongSwan configs for every Geneve tunnel managed by ovn-controller.
Pulls in strongswan + strongswan-pki as transitive deps.
Required by bead mulga-siv-125.3.5.
* feat(daemon): enable OVN native IPsec on intra-AZ Geneve at startup
When network.ipsec_enabled is true (default), the daemon points the
local OVS DB other_config at the per-node IPsec peer cert that admin
init / admin join provisioned (configDir/ipsec/peer.{pem,key} + the
cluster CA at configDir/ca.pem), then sets
other_config:ipsec_encapsulation=true.
ovs-monitor-ipsec (shipped by the openvswitch-ipsec package) consumes
those pointers and materialises strongSwan configs for every Geneve
tunnel ovn-controller programs — including OVN-IC inter-AZ tunnels
when federation lands in Phase 3a.
Missing cert files log a warning and leave Geneve plaintext; operators
upgrading an older cluster reissue certs via spx admin to close the
gap.
Bead mulga-siv-125.3.5.
* test(e2e): multinode IPsec wiring + xfrm SAs + ESP capture
TestMultinodeIPSec asserts:
- OVS DB on every node carries certificate/private_key/ca_cert pointers
and other_config:ipsec_encapsulation=true (what daemon.enableOVNIPSec
writes).
- ip xfrm state on every node has at least one AEAD SA in AES-GCM mode
(rfc4106(gcm(aes)) or gcm(aes)) within 90s.
- tcpdump catches ESP (ip proto 50) on the underlay (best-effort —
logged only; geneve may be idle during the 5s capture window).
Skips cleanly when the cluster was bootstrapped with --ipsec=false
(no ipsec_encapsulation key on first node).
Read-only over SSH; runs in the parallel bucket alongside the other
non-mutating multinode tests.
* fix(igw): write attachment State="attached" for AWS parity
Reconciler intent loader (network/reconcile/intent.go::loadIGWs) filters
IGW records with `State == "attached"`, but AttachInternetGateway was
writing `State = "available"`. The reconciler therefore never picked up
any attached IGW — `intent_igws=0` on every pass — so the OVN external
switch + gateway LRP + WAN bridge wiring built by IGWManager.AttachIGW
never ran for default-VPC IGWs (whose live `vpc.igw-attach` publish at
daemon bootstrap is lost — vpcd subscriber not yet wired).
Net effect on single-node e2e: every SSH probe to 192.168.x public IPs
timed out (TestSSHProbe, TestModifyInstanceAttribute, TestRebootInstance,
TestNATGateway, TestSGToSGDatapath) because SNAT/DNAT rules on the VPC
router had no path to the external network.
Match AWS InternetGatewayAttachment.State semantics:
- Attach: State="attached"
- Detach: State="detached"
Detach value is internal — recordToEC2 gates Attachments on VpcId != "",
so the detached State is never surfaced to API consumers.
Bead: mulga-siv-131
* fix(reconcile): call AttachIGW when IGW topology missing
applyIGWs previously deferred to the NATS handler when an intent IGW
had no external switch in OVN. When the vpc.igw-attach event is lost
(bootstrap-time default-VPC IGW published before vpcd subscriber is
ready), deferral never resolves and VM public-IP traffic dies.
Call IGWManager.AttachIGW directly — it is idempotent (short-circuits
when the external switch already exists), so the reconciler converges
default-VPC IGWs on first pass without duplicating work on subsequent
passes.
Closes mulga-siv-132.
* fix(test): align NewExternalIPAM call with 2-arg signature
Rebase onto dev pulled in daemon_system_instance_test.go which used
the legacy 3-arg NewExternalIPAM(jsNC, js, pools). The feature branch
already narrowed the signature to (js, pools) via the upstream-DHCP
config drop; align the test with the current signature.
* fix(vpcd): EnsureSubnet must EnsureVPC first to avoid NATS race
vpc.create-vpc and vpc.create-subnet are independent NATS events with
no inter-event ordering guarantee. Tenant bootstrap on iam.account.created
publishes both within <1ms, so the subnet handler's
CreateLogicalRouterPort can race the parent VPC's CreateLogicalRouter and
fail with "logical router not found". The cascade fails CreateNetworkInterface
which fails RunInstances which surfaces as InsufficientInstanceCapacity to
the SDK — masking the underlying topology race.
handleSubnetCreate now calls EnsureVPC(VPCID-only) before EnsureSubnet.
EnsureVPC short-circuits on existing LR (idempotent), so the race-winning
vpc.create-vpc handler's full CIDR/VNI ExternalIDs are preserved; if subnet
wins the race the LR is created with bare ExternalIDs (cosmetic) and the
follow-on vpc.create-vpc short-circuits.
Adds TestIntegration_SubnetBeforeVPC regression covering both orderings.
Closes mulga-siv-133.
* feat(ansible): require --external-pool, drop NAT, forward EXTRA_VARS
spx admin init now rejects --external-mode=nat and demands --external-pool
when mode=pool. The ansible init role silently skipped pool flags when the
range was unset, so installs fell over inside the spx validator. Make
targets also swallowed `-e` (make's env-override flag), so operators could
not override pool start/end without editing defaults.yml.
- vars/defaults.yml: rename nat_gateway_ip → external_gateway_ip; add
spinifex_external_no_external opt-out; document the spx flag contract.
- roles/init/tasks/main.yml: drop NAT branch; assert pool range upfront
with a fail_msg pointing at EXTRA_VARS / defaults.yml; emit gateway,
prefix-len, gateway-ip only when explicitly set (let spx auto-detect);
honour --no-external.
- playbooks/dev-reset.yml: rename captured var; coerce legacy
external_mode=nat to pool with a warn; tighten gateway regex with \b.
- Makefile: ansible-dev-* targets now forward EXTRA_VARS="key=val ..."
through --extra-vars so `make` callers can override without editing
defaults.yml.
- scripts/ansible/README.md: document pool requirement, both invocation
styles (direct -e vs make EXTRA_VARS), NAT removal.
* fix(ipsec): guard ipsec_encapsulation on ovs-monitor-ipsec liveness
enableOVNIPSec set OVS cert pointers + ipsec_encapsulation=true without
ensuring ovs-monitor-ipsec.service was running. Without that daemon, OVS
holds the cert pointers unused, strongSwan never gets IKE config, and
tunnel traffic ovn-controller marks for encryption gets silently
dropped. TestMultinodeIPSec fails on `node1 xfrm has no AEAD SAs`.
- systemd: spinifex-daemon Wants=/After= ovs-monitor-ipsec.service
- daemon: ensureOVSMonitorIPSecActive — systemctl enable --now +
is-active poll; refuses to flip ipsec_encapsulation if daemon is dead
- daemon: single-node short-circuit — no peers means no tunnels means
the flag is at best inert and at worst load-bearing-silent-drop
- ci: capture-net-diag.sh + workflow steps to snapshot OVS/OVN/xfrm
state on failure, fan out across all 3 multinode nodes
Refs: mulga-siv-136
* test(e2e): sticky-skip downstream SSH tests when probe fails
When TestSSHProbe times out (3 min, typically because of mulga-siv-134
datapath bug), four downstream tests each re-probe SSH on the same
broken datapath and time out identically — single-node job runs ~24 min
instead of ~12 min, with the same error logged five times.
First waitForSSHReady timeout now sets a package-level atomic flag;
subsequent waitForSSHReady / trySSHReady / requireSSHHealthy calls skip
immediately. Preserves the original red signal on TestSSHProbe and on
any test that genuinely needed SSH (Skip ≠ Pass). Bool variant
(trySSHReady) consults but does not set the flag — its caller already
treats False as advisory warning, not fatal.
TestSGToSGDatapath has its own EventuallyErr SSH wait (not via
waitForSSHReady) and needs an explicit requireSSHHealthy(t) gate at
the top of runSGToSGDatapath. TestNATGateway already calls
waitForSSHReady first so the gate fires naturally.
Refs: mulga-siv-137
* fix(ipsec): use Debian unit name openvswitch-ipsec.service
CI artifact shows `Unit ovs-monitor-ipsec.service could not be found`
on every node. Debian's openvswitch-ipsec package ships the unit as
openvswitch-ipsec.service (the binary inside is ovs-monitor-ipsec, but
systemd's name follows the package). The previous commit guarded on
the wrong unit name, so:
- spinifex-daemon.service Wants=/After= silently no-op'd (missing unit)
- enableOVNIPSec's `systemctl enable --now ovs-monitor-ipsec.service`
failed, daemon logged a warning and continued without flipping
ipsec_encapsulation=true
- TestMultinodeIPSec skipped with `node1 reports ""` because OVS DB
never received the cert pointers
Rename across all 5 spots (daemon, systemd unit, test, CI diag script,
workflow journal capture) to match the Debian package layout.
Note: the package itself still must be present on the CI VM image —
that's tracked in the mulga repo (image-builder provision.sh +
bootstrap-install.sh shim).
Refs: mulga-siv-136
* fix(e2e): authorize default SG tcp/22 + icmp in single-node fixture
admin init leaves the default SG closed (AWS parity); the Go single suite
never ported the Phase-5 SG-ingress block that run-e2e.sh has had since day
one, so every test runner SSH/ping probe hits the OVN port-group ACL drop.
- ec2helpers: add AuthorizeICMPIngress + EnsureDefaultSGOpen helpers.
- single/main_test: open default SG once per process in pkgFixOnce.Do.
- witness: extend ensureDefaultSGSSHIngress to authorize ICMP too.
- run-e2e.sh: append matching ICMP authorize next to tcp/22 block.
mulga-siv-134
* fix(network/reconcile): key DHCP_Options lookup by subnet_id not CIDR
Multi-tenant default VPCs share the same subnet CIDR (172.31.0.0/20) per
account. The existing FindDHCPOptionsByCIDR gate at apply.go:107 found
the first account's DHCP_Options row and skipped creation for every
subsequent subnet with the same CIDR. Those subnets' ports then attached
nothing (FindDHCPOptionsByExternalID misses on subnet_id), VMs got no
DHCPv4 lease, and SSH/ICMP into them silently failed even though SG
ACLs and NAT were correct.
Switch the gate to FindDHCPOptionsByExternalID keyed on spinifex:subnet_id
so each subnet owns its own row, matching the attach lookup at line 203.
Verified: account 000000000001 default VPC RunInstances now produces an
LSP with dhcpv4_options populated, VM cloud-init reports a 172.31.0.5/20
lease + default route via 172.31.0.1, and ping + ssh TCP handshake to
the EIP succeed end-to-end. Stale DHCP_Options row for the prior dead
subnet was wiped manually; reconciler recreated the correct row for the
live subnet on its next pass.
* fix(ipsec): enable openvswitch-ipsec at provision time, drop daemon write
Provisioning now runs `systemctl enable --now openvswitch-ipsec.service`
alongside openvswitch-switch and ovn-controller. The spinifex-daemon
process drops its `enable --now` shell-out and only polls is-active.
Sudoers gains one read-only line:
spinifex-daemon ALL=(root) NOPASSWD: /usr/bin/systemctl is-active openvswitch-ipsec.service
This mirrors the existing vpcd ovn-controller is-active precedent and
removes the daemon's need for systemd-write capability. Aligns with
least-privilege service account pattern: provision enables services,
daemon only reads status.
If the unit is inactive at runtime, the daemon refuses to flip
ipsec_encapsulation=true (silent-drop guard from mulga-siv-136) and
surfaces a clear error pointing at scripts/setup-ovn.sh.
* chore: unblock preflight on feat/network-layer-redesign
Two pre-existing failures blocked preflight on the branch:
- govulncheck flagged golang.org/x/net@v0.54.0 (GO-2026-5026, ASCII Punycode
rejection bug in idna.ToASCII); reached via utils.DownloadFileWithProgress.
Bump to v0.55.0; go mod tidy carries x/sys to v0.45.0.
- TestTopologyHandler_SubnetCreate_RouterPortFails asserted subnet create
fails when the parent VPC router is missing. That contract changed in
|
||
|
|
20a8a39608 | feat: flip images to UEFI default (#237) | ||
|
|
4ae2a4ac53 |
feat(elbv2): QEMU microvm direct-boot for LB system instances (#228)
* feat(vm): direct-boot foundations + config/input extensions + image build pipeline
vm package (mulga-siv-62):
- Add KernelImage, Initrd, KernelCmdline, FwCfg/FwCfgEntry to vm.Config
- Emit -kernel/-initrd/-append/-fw_cfg args when fields set
- Relax drive invariant: accept kernel image in place of drives
- Add devices.go: IsMMIO predicate, NetDevice/BlkDevice/RngDevice helpers
- Refactor lifecycle.go + network_helpers.go call sites to use helpers
- shutdown.go: os.Remove fw_cfg tmpfiles after QEMU exits
- Add devices_test.go, microvm_test.go; extend vm_test.go
config/input extensions (mulga-siv-63):
- Add MicrovmConfig{ELBv2Enabled, ImagePath} to DaemonConfig
- ImagePath falls back to /usr/share/spinifex/microvm when empty
- Add commented [microvm] section to spinifex.toml template
- Add DirectBoot bool + NICs []NICConfig to SystemInstanceInput
image build pipeline (mulga-siv-64):
- scripts/build-microvm-image.sh: Alpine chroot build producing vmlinuz + initramfs.cpio.gz
- build/microvm/init.sh: fw_cfg-driven PID 1 init (mounts, modprobe, NIC config, lb-agent-env, ca-cert)
- build/microvm/inittab: BusyBox init with lb-agent respawn
- make build-microvm-image target
- setup.sh: install microvm/* to /usr/share/spinifex/microvm/
- .gitignore: exclude built vmlinuz + initramfs.cpio.gz artifacts
* feat(daemon): direct-boot launch path for microvm system instances
When SystemInstanceInput.DirectBoot=true:
- Skip GetAMIConfig and GenerateVolumes
- Build vm.Config directly (no buildBaseVMConfig, no PCIe root ports)
- MachineType=microvm,x-option-roms=off,pic=off,pit=off,rtc=on,acpi=on,isa-serial=on
- Resolve kernel/initrd from Microvm.ImagePath config field
- Serialise NICs to three fw_cfg tmpfiles (netcfg, lb-agent-env, ca-cert)
- Validate exactly one NICConfig.IsDefault=true before writing netcfg blob
- Shutdown path cleans up tmpfiles via existing Config.FwCfg iteration
PC-machine path (DirectBoot=false) unchanged.
Closes mulga-siv-65
* feat(elbv2): wire microvm.elbv2_enabled flag into ELBv2 service
When ELBv2Enabled=true:
- Drop lbVMUserData cloud-config; emit KEY=value LBAgentEnv blob instead
- Set SystemInstanceInput.DirectBoot=true; omit ImageID
- Populate NICs []NICConfig (index 0=primary ENI IsDefault, 1=mgmt, 2+=extra ENIs)
- Validate exactly one IsDefault NIC at service layer
When ELBv2Enabled=false: existing PC-machine path unchanged.
Adds buildLBAgentEnv, buildMicrovmNICs, subnetCIDRForIP, subnetGatewayIP helpers.
Tests in arn_test.go cover both flag-on and flag-off paths.
Closes mulga-siv-66
* test(daemon,vm): add unit tests for direct-boot helpers to meet diff coverage threshold
* feat(daemon): Phase 1 perf instrumentation + e2e runner microvm flag
- Log t1→t2 boot timing via slog on the direct-boot path
- measureQEMURSSMiB helper reads /proc/<pid>/status (tested)
- Gate constants: phase1BootGateMs=500, phase1RSSGateMiB=25
- run-lb-e2e.sh: --microvm flag, dual-path CI annotation, density test note
Closes mulga-siv-67
* fix(build): remove busybox-initscripts — not in Alpine 3.20, not needed
* fix(microvm): end-to-end fixes for direct-boot LB path
Serial output was silent (x-option-roms=off suppresses BIOS serial init);
fixed by removing it from the machine string and using -serial chardev:console0
to attach to the machine-created ISA serial device instead of adding a
duplicate isa-serial device (which would create ttyS1 while kernel uses ttyS0).
virtio-net interfaces were invisible to the kernel because QEMU's
auto-kernel-cmdline does not append virtio_mmio.device= params when -append
is used. Fixed by generating explicit virtio_mmio.device=0x200@0xfebNNNNN:N
params for each NIC in KernelCmdline, and modprobing virtio_mmio + virtio_net
in init.sh.
sys.micro bumped to 512 MiB — 128 MiB caused kernel OOM during initramfs
decompression (~68 MiB uncompressed).
BusyBox init ::respawn: entries do not source or export env files; fixed
inittab to use set -a; . /etc/conf.d/lb-agent; set +a before exec.
wireLBAgentConfig was documented as reading the CA cert but never set
elbv2Service.CACert; lb-agent TLS handshakes to AWSGW failed with
x509: certificate signed by unknown authority. Fixed by reading
d.config.NATS.CACert (same local CA that signs the AWSGW server cert)
and assigning to elbv2Service.CACert so writeFwCfgBlobs writes a
non-empty cacert blob into fw_cfg.
Adds vm_test TestExecute_MicrovmFileChardev and updates lifecycle_test
to assert SerialSocket is intentionally empty on direct-boot VMs.
* fix(build): auto-detect docker/podman when apk unavailable for microvm image build
* fix(build): create /dev/console and /dev/null as proper device nodes in initramfs
tar extraction without root silently demotes device files to 0-byte regular
files (mknod requires CAP_MKNOD). The kernel opens /dev/console when wiring
init's stdio to the serial console; a regular file there causes all init output
to be silently discarded to RAM — the VM appears stuck at 'Run /init as init
process' with no subsequent console output and lb-agent never heartbeats.
Fix: after rootfs population, wipe /dev and recreate console (c 5 1) and
null (c 1 3) via sudo mknod. devtmpfs provides all other devices at runtime
once init.sh mounts it.
* fix(microvm): fix mgmt NIC routing for all LB schemes
Two bugs prevented lb-agent from reaching the AWSGW via the mgmt interface:
1. RouteDst/RouteVia swapped — resolveMgmtRoute returns (gateway, target) but
buildMicrovmNICs assigned them as (Dst=gateway, Via=target), producing
'ip route add 10.15.8.1 via 192.168.1.33' instead of the correct
'ip route add 192.168.1.33 via 10.15.8.1'.
2. NIC[1] MAC and CIDR never filled — the daemon allocates mgmt IP/MAC
after buildMicrovmNICs returns, but didn't inject them into input.NICs[1]
before calling writeFwCfgBlobs, leaving NIC1_MAC= empty in the netcfg
blob and skipping interface setup in init.sh entirely.
Also extends mgmt routing to internet-facing scheme in the microvm path:
VPC SNAT is not reliable across all VPC topologies for control-plane
heartbeats; mgmt is always a direct L2 path to the host.
* feat(microvm): Phase 2 kernel stripping + boot optimisation
- cpu: switch to host,-pmu (disable PMU — not needed in microvm guest)
- machine type: make isa-serial configurable via microvm.isa_serial config
field; default true (on) preserves console log path
- build: strip unused kernel modules (USB, IDE, ATA, GPU, media, input,
HID, bluetooth, staging, sound, wireless) from initramfs before cpio
- build: add Phase 2 artifact size gate — fail if vmlinuz + initramfs.cpio.gz
exceeds MICROVM_ARTIFACT_MAX_MiB (default 50 MiB); override via env var
during development
- perf: add phase2BootGateMs=300 and phase2ArtifactGateMiB=50 constants
with canary tests to catch unintentional gate changes
- tests: cover buildMicrovmNICs nil-VPC and extra-ENI paths
- tests: cover microvmMachineType nil/true/false branches
* fix(build): use find-based virtio+fw_cfg module keep-list in initramfs strip
The directory-only keep-list (drivers/virtio, drivers/firmware) missed
virtio_net.ko which lives in drivers/net/, virtio_blk in drivers/block/,
and virtio-rng in drivers/char/hw_random/. Switch to find-based approach:
collect all virtio*.ko* and *fw_cfg*.ko* regardless of subdirectory, then
restore them into their original relative paths under kernel/.
Artifacts now: 42 MiB (vmlinuz 11 MiB + initramfs 31 MiB), gate passes.
* fix(build): keep failover modules in initramfs strip
virtio_net depends on net_failover/failover for live-migration support.
Stripping them left virtio_net with unresolved symbols
(net_failover_create/destroy), so the module failed to load and the
guest came up with only lo. init.sh then skipped every NIC ("no
interface found for MAC ..."), leaving lb-agent with no network path
to AWSGW and the LB stuck in provisioning.
Add *failover*.ko* to the keep-list. Image size unchanged at 42 MiB
(under the 50 MiB Phase 2 gate). ELBv2 e2e now reaches active and
2/2 targets healthy for both ALB and NLB internal LBs.
* fix(daemon): restore slog default after viperblock.New mutates it
viperblock.New unconditionally calls vb.SetDebug, which calls
slog.SetDefault with a TextHandler at LevelError — globally silencing
every slog.Info and slog.Warn in the caller process for the rest of
its life. Discovered while validating microvm Phase 2 (mulga-siv-68):
the daemon stopped emitting Info logs the moment the first customer
VM with volumes launched, hiding direct-boot timing,
LaunchSystemInstance completed, and CreateLoadBalancer completed
lines that we need for boot-time tuning.
Workaround in newViperblock: re-install an Info-level TextHandler on
os.Stderr after each viperblock.New call. Also drop the three explicit
vb.SetDebug(false) calls in prepareRootVolume / prepareEFIVolume /
prepareCloudInitVolume — they were no-ops (viperblock.New already
runs SetDebug internally) and each one re-triggered the global
mutation we are trying to undo.
Proper fix is in viperblock itself — tracked as mulga-siv-70: SetDebug
should not call slog.SetDefault. Until then, this restore call is the
shortest path to getting the daemon's observability back so we can
measure t1_to_t2_ms and tune Phase 2.
Preflight note: golangci-lint not available on this dev host, so the
project preflight target cannot run end-to-end. Verified with
go vet ./spinifex/handlers/ec2/instance/... (clean) and
go test ./spinifex/handlers/ec2/instance/... (pass).
* perf(microvm): hit Phase 2 boot/memory gates
t1→t2 hypervisor: 3224 ms → 264 ms (12×). 128 MiB guest now boots
cleanly without OOM, reverting the temporary 512 MiB bump.
Root causes:
1. build-microvm-image.sh staged the entire chroot into the cpio
without dropping /boot, embedding a duplicate vmlinuz, Alpine's
stock initramfs-virt, System.map, and a "boot → ." symlink loop
(~25 MiB). Decompression peak exceeded 128 MiB. Strip /boot after
the kernel is copied out, before the cpio. Initramfs drops from
31 MiB → 11 MiB (53 MiB → 28 MiB uncompressed); total artifact
42 MiB → 22 MiB.
2. vm/lifecycle.go burned 3 s of fixed sleep on every direct-boot
launch: 2 s nbdkit pre-exec wait (no nbdkit on direct-boot) and
1 s post-fork settle (QEMU binds QMP within ~10 ms when there is
no firmware, ROM, or block layer). Both extracted to
directBoot-aware helpers — nbdkitPreExecWait collapses to 0, and
qemuStartSettleWait to 50 ms.
3. KernelCmdline only carried `console=ttyS0 virtio_mmio.device=…`.
Added boot-time perf flags: quiet loglevel=3 (silence printk over
115200-baud isa-serial), mitigations=off (KVM guest on trusted
host, single-tenant LB workload), tsc=reliable, no_timer_check,
reboot=t, i8042.{nopnp,noaux,nokbd} (microvm has no PS/2).
4. init.sh dropped modprobe virtio_mmio (built-in:
CONFIG_VIRTIO_MMIO=y) and tightened polling: fw_cfg/iface waits go
from 10 × 200 ms (up to 2 s) to 5 × 20 ms (up to 100 ms).
Phase 2 gates:
- t1→t2 ≤ 300 ms ✅ 264 ms / 281 ms
- artifact ≤ 50 MiB ✅ 22 MiB (gate already in build script)
- ELBv2 e2e green ✅ 32/33 (pre-existing client-VM failure,
unrelated to microvm path)
* build(microvm): wire build into deploy + distro + release pipeline
Adds install-microvm Makefile target (with grouped-target staleness
detection on vmlinuz/initramfs.cpio.gz), wires it into dev-install.sh
and reset-dev-env.sh, makes 'make deploy' reinstall artifacts when
present, and makes 'make distro-amd64' stage build/microvm/* into the
release tarball staging dir. arm64 distro stays unchanged (no aarch64
microvm artifact yet — Phase 4).
Release workflow gains a setup-go step and a 'make build-microvm-image'
step before 'make distro-amd64' on the amd64 runner so the resulting
tarball includes the kernel + initramfs without a manual copy.
Precursor for the Phase 3 PC-machine LB removal (mulga-siv-69).
Closes mulga-siv-71.
* build(ansible): include microvm artifacts in build role tarball
Adds a build-microvm-image task to the ansible build role and stages
build/microvm/* into the role's release tarball so the install role's
setup.sh run picks them up via INSTALL_SPINIFEX_TARBALL. Skipped
gracefully when the build script is absent (older branches without
direct-boot LB wiring).
* feat(config): enable microvm direct-boot LB path by default
Uncomments the [nodes.<node>.daemon.microvm] section in the generated
spinifex.toml template and sets elbv2_enabled = true so all new
clusters bring up ELBv2 LBs via the direct-boot microvm path. Operators
can opt back to the legacy PC-machine path by flipping the flag to
false in the rendered config.
Required for end-to-end CI on this branch to exercise the direct-boot
path. Existing clusters' configs are unchanged (the template only
affects fresh 'spx admin init' renders).
* fix(microvm): bootstrap apk.static when no host rootfs tool exists
Self-hosted CI runners and the GitHub-hosted ubuntu-24.04 image often
have none of apk, docker, or podman installed. apk-tools is not in the
Debian 13 (trixie) repositories. Without one of these the rootfs build
fails up front with 'no rootfs build tool available'.
When all three are absent, fetch apk-tools-static from the configured
Alpine mirror, extract it to a tempdir, and prepend it to PATH so the
existing native-apk strategy below picks it up transparently. Requires
only curl + tar, both of which are present on every CI runner that can
already check out source.
No-op when apk, docker, or podman is already present.
Unblocks https://github.com/mulgadc/spinifex/actions/runs/25988830244
* revert: drop apk.static bootstrap in build-microvm-image
Reverts 0bd76b7. Self-hosted runners will get docker.io installed
out of band; existing Strategy 2 (docker run alpine:3.20) handles
the rootfs build without host sudo or unsigned package install.
* docs(workbook): drop lb-alpine import for microvm direct-boot LB
LBs now launch via direct-boot QEMU microvm using kernel + initramfs
bundled at /usr/share/spinifex/microvm/, so the legacy lb-alpine system
AMI import is no longer required.
* fix(daemon): own tap devices by daemon user so QEMU can attach without CAP_NET_ADMIN
When the daemon runs non-root (production: User=spinifex-daemon), child
QEMU processes inherit that uid but lack CAP_NET_ADMIN. The kernel's tun
attach check then requires the tap owner uid to match the caller's euid.
Without the `user` flag, `ip tuntap add` defaults to root:root and qemu's
TUNSETIFF fails with EPERM ("could not configure /dev/net/tun: Operation
not permitted").
Surfaced by the e2e-nightly cell-17 microvm LB launch on the ci-pseudo
runner where the kernel enforces strictly; legacy EC2 launches on
ci-single runners happened to attach successfully despite the same code
path. Adding `user $current group $gid` to `ip tuntap add` ensures the
tap is owned by whatever uid the daemon (and its qemu children) run as.
Root daemons skip the flag — they have CAP_NET_ADMIN ambient.
* fix(e2e): redirect lb probe chatter to stderr so stalls are visible
test_http_from / test_tcp_from echoed progress to stdout, which the
callers captured into *_OK vars via $(...). Result: 6+ minute retry
loops ran silently in CI, and the "$ok" comparison never matched
"true" because the captured value contained the full multi-line
chatter. Reachability pass/fail counters were also lost in the
subshell.
Redirect helper output to stderr, leave only the true/false flag on
stdout, and move pass/fail to the caller so they actually count.
* fix(microvm): don't /32 AdvertiseIP via mgmt for internet-facing single-node
buildMicrovmNICs overrode resolveMgmtRoute's deliberate empty return
for the single-node internet-facing case by falling back to
(MgmtBridgeIP, AdvertiseIP). That installed a /32 route to AdvertiseIP
via the mgmt NIC inside the LB microvm. On single-node where the
AWSGW host IP equals the WAN client IP, the /32 also catches reply
traffic for inbound HTTP/TCP to the LB's floating IP — replies leave
via the mgmt NIC with src=data-NIC IP, the host kernel drops the
asymmetric flow, and same-chassis ingress hangs.
resolveMgmtRoute already encodes the correct policy:
- multi-node any scheme → explicit MgmtRoute{Gateway,Target}
- single-node internal → fallback to (MgmtBridgeIP, AdvertiseIP)
- single-node internet-facing → empty (reach AWSGW via VPC SNAT)
Honor it. Matches the legacy lbVMUserData path, whose own comment
flagged the stolen-WAN-return-path symptom this introduced.
Test covers all three branches.
* feat(ansible): dev-deploy playbook for in-place artifact swap
Fills the gap between ansible-dev-install (skips when already installed)
and ansible-dev-reset (full teardown + reinstall + smoketest). Mirrors
Makefile `deploy` target: rebuild + replace binaries and microvm
artifacts on a running node, restart spinifex.target, wait for awsgw.
Skips setup.sh (no user/dir/systemd-unit changes) and smoketest so
iteration is fast. Use ansible-dev-reset when changing systemd units,
helper scripts, logrotate, or setup.sh itself.
Adds:
- roles/deploy/tasks/main.yml — install spx + nbdkit plugin + microvm
artifacts, with plugindir auto-detection via `nbdkit --dump-config`.
- playbooks/dev-deploy.yml — chains build + deploy roles.
- Makefile ansible-dev-deploy target.
- README playbook table + "when to use which" guidance.
* chore(microvm): remove legacy LB Alpine image build pipeline
Phase 3 microvm removal — strip the PC-machine LB image build
artifacts that direct-boot no longer needs. The microvm initramfs
already carries lb-agent + HAProxy via build-microvm-image, so the
lb.conf manifest, lb-setup.sh chroot script, build-lb-image target,
dev-install / reset-dev-env import steps, and ansible LB-image tasks
all become dead.
build-system-image stays — other manifests (e.g. GPU images) still
use it.
* refactor(microvm): remove legacy PC-machine LB boot path
Phase 3 — direct-boot becomes the only ELBv2 LB launch path.
- Drop SystemInstanceInput.DirectBoot / ImageID / UserData (every LB
caller set DirectBoot=true; legacy cloud-init userdata is gone).
- Drop ELBv2ServiceImpl.lbVMUserData, systemAMI* fields, SetSystemAMIFunc,
getSystemAMI, and the lazy-AMI wiring in daemon.startCluster.
- Collapse CreateLoadBalancer to a single direct-boot launch input.
- Collapse daemon.LaunchSystemInstance: drop AMI validation, ImageID
on RunInstancesInput, UserData base64 encode, GenerateVolumes branch.
buildDirectBootConfig hardcodes /usr/share/spinifex/microvm and
isa-serial=on (microvmMachineType no longer takes a flag).
- Drop MicrovmConfig from config.DaemonConfig and the
[daemon.microvm] section from the spinifex.toml template.
- Prune dead tests (lbVMUserData_*, PCMachine_Unchanged, AMI resolver
paths) and refresh stale comments that still mentioned lbVMUserData.
ARM hosts have no LB launch path until Phase 4 adds direct-boot on
virt — CreateLoadBalancer on aarch64 fails naturally at QEMU exec.
* docs: drop lb-alpine catalog entry from cluster setup guide
LB system instances no longer use an AMI — direct-boot microvm
artifacts ship in the spinifex package.
* feat(ui): remove LB image import banner + LB-AMI gating
Direct-boot microvm artifacts ship in the spinifex package, so the
LB system AMI no longer exists — the "Load balancer image not imported"
banner and the Create-button disable on the LB list / wizard pages
can never fire. Strip:
- lb-image-missing-banner.tsx component
- hasLbImage / isLbImage / LB_IMAGE_NAME / LB_MANAGED_BY_VALUE from
system-managed.ts (isSystemManagedImage stays — still used by the
EC2 Images pages to hide system AMIs)
- Banner gating + ec2ImagesQueryOptions imports from the LB list and
wizard pages
- The corresponding tests that asserted the banner appears
* revert: restore lb.conf + lb-setup.sh for mulga install pipeline
Phase 3 microvm removal (commit
|
||
|
|
26c2c9fa49 | fix(setup): replace /dev/stdin in tmpfiles.d write to work without /dev mount in chroot | ||
|
|
28ca689130 |
feat: VFIO GPU passthrough (#188)
* feat: add GPU discovery package (mulga-992) Adds spinifex/gpu package with sysfs-based GPU enumeration, IOMMU group member lookup, and a PCI device ID model table. Vendor-specific enrichment via nvidia-smi is attempted opportunistically and falls back to the built-in table when unavailable. All discovery and IOMMU logic is covered by unit tests using mock sysfs trees. * feat: add VFIO bind/unbind and GPU pool manager (mulga-993) Adds gpu.BindVFIO/UnbindVFIO using sysfs driver_override for per-device driver switching, and gpu.Manager which owns the claim/release lifecycle for the GPU pool including full IOMMU group binding, rollback on partial failure, and marking entries unavailable when rebind fails after VM termination. * feat: add G5 instance type generator with GPU model support (mulga-994) - Add GPUModel type, NVIDIAa10g constant, and GPUModelForVendorDevice lookup - Add generateGPUTypes to emit g5.* types with GpuInfo populated - Add IsGPUType helper for consumers filtering GPU-capable types - Update DetectAndGenerate to accept gpuModels []GPUModel parameter * feat: integrate GPU passthrough into daemon lifecycle (mulga-995) - Add gpu_passthrough config flag; discover GPUs and build manager at startup - Gate g5 instance types on GPU pool availability via canAllocateCount - Claim GPU (VFIO bind) in LaunchInstance; inject vfio-pci QEMU device - Release GPU (VFIO unbind, rebind to host driver) in stopInstance - Re-claim GPU on daemon restart when QEMU process is still alive - Add UseUEFI / OVMF support for x86_64 VMs (optional, falls back to SeaBIOS) - Fix Claim to use stored OriginalDriver when device is already vfio-pci bound * feat: add GPU fields to NodeStatus and spx top nodes (mulga-996) - Add TotalGPUs/AllocGPUs to NodeStatusResponse (zero on non-GPU nodes) - Populate from gpuManager in handleNodeStatus - Show GPU (used/total) column in spx top nodes; "-" when no GPUs present * feat: Ubuntu 24.04 GPU AMI build pipeline (mulga-997) Extends build-system-image.sh to support Ubuntu alongside Alpine. Key differences handled: partition table (parted resizepart p1), bind mounts for DKMS (/proc /sys /dev), apt vs apk, systemctl vs rc-update. DISTRO defaults to "alpine" for backward compatibility. Adds ubuntu-gpu.conf manifest and ubuntu-gpu-setup.sh chroot script that installs nvidia-headless-550-server with DKMS pre-built against a pinned linux-image-generic kernel, blacklists nouveau, and prevents unattended-upgrades from invalidating the pre-built module. * Fixed GPU passthrough and added test script * feat: always-probe GPU at startup, surface capability in NodeStatusResponse - Add gpuProbeResult struct and probeGPU() which runs at daemon startup regardless of gpu_passthrough config. Checks sysfs for GPUs, IOMMU groups, and vfio_pci module presence. - Store gpuProbe on Daemon struct; split NewDaemon into probe (always) and activate (opt-in) phases. - Populate GPUCapable, GPUPassthrough, GPUModels on NodeStatusResponse so operators can see hardware state before enabling passthrough. - Update 'spx top' GPU column: '-' = no hardware, '0/N*' = capable but passthrough not active, 'used/total' = passthrough active. * feat: SIGHUP hot-reload for GPU passthrough config (mulga-1001) - Export GenerateGPUTypes for use by the reload path - Add ResourceManager.reloadGPUTypes: mutates instanceTypes map in-place (preserves references held by instanceService) and updates NATS subscriptions without full daemon restart - Separate SIGHUP from SIGTERM/SIGINT: setupReload() listens for SIGHUP in a context-aware loop; setupShutdown no longer intercepts SIGHUP - Add reloadConfig() + applyGPUConfig(): re-reads spinifex.toml on signal, handles false→true (re-probe + activate) and true→false (refuse if instances running, otherwise deactivate) transitions * feat: spx admin gpu status/enable/disable commands (mulga-1000) - admin.SetGPUPassthrough: Go implementation of the idempotent TOML write (replaces the inline Python heredoc in spx-test-gpu.sh) - spx admin gpu status: shows GPU hardware, IOMMU/vfio state, passthrough activation, and advertised g5 instance types via NATS NodeStatusResponse - spx admin gpu enable: checks prerequisites, writes TOML, sends SIGHUP, polls until daemon confirms GPUPassthrough=true - spx admin gpu disable: refuses while GPU instances are running, otherwise writes TOML, sends SIGHUP, polls until confirmed - spx-test-gpu.sh: replace Python TOML heredoc with spx admin gpu enable * fixed admin * fix: filter Intel iGPU from passthrough pool, use lspci for consumer GPU names Discover() now skips non-NVIDIA/AMD vendors so Intel iGPUs never enter the passthrough pool. enrichFromLspci() uses the system PCI ID database via lspci -vmm to populate the model name for any card not in the hardcoded table, without needing nvidia-smi or driver tools. * fix: grant CAP_SYS_ADMIN and vfio device access to spinifex-daemon GPU passthrough requires writing to /sys/bus/pci/drivers/vfio-pci/unbind on instance stop. The kernel gates this on CAP_SYS_ADMIN regardless of file permissions. QEMU subprocesses also need char-vfio rw access to open /dev/vfio/N for the passed-through device. * fixing gpu bining permissions * working state of gpu passthrough on phyiscal box * installer grub image fixes * made gpu-passthrough more user facing * fixed banner * fixed banner * banner fix * gpu passthrough docs * preflight tweak * vpcd fixes to set br-wan to promisc for public IP DHCP processes * fixed vpcd br-wan promisc and veth pair * ssh keygen fix * fixes after running /review-branch * feat: re-wire GPU claim and device injection after vm.Manager refactor GPU passthrough claim (VFIO bind) and QEMU device injection were lost when dev's vm.Manager refactor (#185/#186) moved StartInstance/ CreateQMPClient into vm/lifecycle.go. Re-add both in their correct new homes: - daemon_handlers_instance.go: claim GPU before vmMgr.Run() in both RunInstances and StartStoppedInstance handlers; release on failure - vm/lifecycle.go startQEMU(): inject vfio-pci device with x-vga flag derived from instance.GPUXVGAEnabled when GPUPCIAddress is set * fix: Create spinifex user ~/.ssh and keys in firstboot --------- Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com> Co-authored-by: Julian Sommer <115516918+juliansommer@users.noreply.github.com> |
||
|
|
9b9bcc5b8f |
fix(setup): mask dhcpcd.service even when apt install skipped
|
||
|
|
04f63ad8c6 |
feat(iso-installer): DHCP race fix + vpcd reconcile gate + ELB mgmt route + HashMAC + diagnostics (#172)
* preflight tweak
* fix: pin gateway LRP to link-local, end intra-cluster ARP collision
Every VPC's IGW gateway-LRP claimed pool.GatewayIP || pool.RangeStart on
attach. Multi-VPC clusters all GARP'd the same .160 with three different
deterministic MACs on the shared br-ext localnet, flapping the upstream
ARP cache and dropping 100% of inbound traffic to dnat_and_snat external
IPs (mulga-siv-26).
handleIGWAttach and reconcileIGW now unconditionally set the gateway
router port to 169.254.0.1/30. The default route's OutputPort already
pins the LRP, so the WAN nexthop need not be on-subnet. Pool IPs stay
allocated only for per-VM dnat_and_snat external addresses, which are
unique by construction.
Self-heal: RetrofitAllGatewayPortNetworks runs at startup and rewrites
stale Networks in place via the new UpdateLogicalRouterPort path. Needed
because Reconcile gates IGW work on "ext switch missing", so a cluster
shipped with the buggy CIDR never re-enters reconcileIGW.
Regression guards: TestTopologyHandler_IGWAttach_MultiVPC_NoIPCollision
and TestReconcileIGW_RewritesStaleGatewayPortNetworks. Existing tests
updated to assert link-local and OutputPort=&gwPortName. Log field
gateway_ip renamed to lrp_network to signal the semantic shift.
* fix: rewrite utils.HashMAC to SHA-256 / 46-bit output
The old 24-bit rolling hash with literal class prefix had birthday-paradox
collision probability of 1% at ~580 ids and 50% at 4096 — well within the
range of a single deployment's resource population (LRPs, ENIs, dev/mgmt
NICs). On a shared L2 segment, two clusters could trivially produce
duplicate MACs, breaking neighbour discovery and DHCP.
Switch HashMAC to SHA-256 across the entire input, taking the low 6 bytes
and forcing the IEEE 802 reserved bits (bit0=0 unicast, bit1=1 LAA) on the
first octet. Output entropy goes from 24 bits to 46 bits — 1% collision
boundary moves from ~580 to ~1.2M ids.
Drop the redundant prefix arg: it was no longer the literal output prefix
under the new scheme, just folded into the hash input. Class disambiguation
moves to the caller, where it's explicit. Three of four callers had nothing
to disambiguate (eni-, subnet-, gw-vpc- ids are already unique); dev and
mgmt NICs share instance.ID and now compose "dev:" / "mgmt:" tags.
Also consolidate vpcd.generateMAC, which was a local duplicate of the
broken algorithm rather than a HashMAC wrapper, into a HashMAC delegation.
Plan: docs/development/bugs/vpcd-mac-collisions-shared-l2.md
Bead: mulga-siv-27
* fix: pin HashMAC first octet to 0x02
Previous impl forced only the IEEE 802 reserved bits (bit0=0 unicast,
bit1=1 LAA) on the first octet, leaving the upper 6 bits hash-derived.
Technically valid LAA unicast, but produced MACs like 4a:.. and fe:..
that visually encroach on vendor OUI space and tripped CI/ops checks
expecting all generated MACs to start with 02:.
Pin byte 0 to literal 0x02; hash bytes 1-5 from sha256[0:5]. Output
entropy drops from 46 to 40 bits — birthday-paradox 1% collision at
~150k ids, still 256x the old 24-bit bound (~580).
* chore(e2e): dump cross-chassis OVN state on guest SSH failure
Adds chassis registrations, port_binding claims, gateway_chassis rows,
ovs-vsctl topology, Geneve tunnel state, and br-int tunnel flows to
dump_guest_ssh_diagnostics so we can pinpoint where the cross-chassis
dataplane stalls (cr-gw chassis vs remote chassis with the VM bound).
* fix: gate vpcd startup reconcile behind NATS KV leader election
N vpcds in a multi-node cluster all hit Get-then-Create on Logical_Router
with no atomicity, producing duplicate rows that ovn-nbctl rejects with
"Multiple logical routers named '...'. Use a UUID."
Add AcquireReconcileLeader using NATS KV CAS (kv.Create on a single key
in spinifex-vpcd-reconcile bucket). Only the elected vpcd runs Reconcile,
ReconcileFromKV, and the two retrofit passes — others Subscribe and rely
on the vpcd-workers queue group for runtime events. MaxAge=60s on the
bucket caps recovery time when a leader crashes mid-reconcile.
Falls through (elected=true) when KV is unavailable so first-boot does
not deadlock on a missing JetStream.
mulga-siv-29
* fix(elbv2): force mgmt host route for internal-scheme LBs (mulga-siv-30)
Single-node CI e2e Phase 3b ALB internal hangs in 'provisioning' for 270s
because the lb-agent inside the ALB VM has no return path to AWSGW.
The gateway-URL decision tree in daemon.wireLBAgentConfig picks advertiseIP
for single-node and deliberately skips adding the /32 mgmt host route — the
WAN-return-path concern in the comment is real but applies only to
internet-facing LBs, which have an EIP and an OVN dnat_and_snat pair that
gives reply traffic a way home. Internal LBs have no EIP / no SNAT, so when
the agent dials advertiseIP the reply targets the VM's private subnet IP from
the host's WAN with no route back.
Make lbVMUserData scheme-aware. New helper resolveMgmtRoute returns the
existing (MgmtRouteGateway, MgmtRouteTarget) when set (multi-node case) and
falls back to (MgmtBridgeIP, AdvertiseIP) when scheme is internal — only
internal LBs need the /32 route, so internet-facing single-node still gets
no bootcmd and the host-initiated WAN path stays clean.
Daemon now exposes MgmtBridgeIP and AdvertiseIP unconditionally so the
fallback has the inputs it needs.
* fix(daemon): stub sudoCommand in TestSetupComputeNode_ValidatesArgs (mulga-siv-31)
The test was calling real SetupComputeNode("chassis-test", ...) which shelled
out via sudoCommand to set external_ids:system-id=chassis-test on the host's
live OVS. On a dev box with OVS installed this overwrote the persistent UUID
(owned by openvswitch-switch and re-applied only on reboot), so vpcd's
discoverChassis filtered out the legitimate SBDB chassis row as 'stale local'
and crashlooped — taking out all VPC ops including ALB ENI provisioning.
Bind sudoCommand to a var so tests can swap it. Stub it in the test to return
exec.Command("/bin/false") and assert SetupComputeNode returns an error. The
test's intent (signature + error-path coverage) is preserved; nothing on the
host is touched.
* chore(vpcd): log DHCP Acquire concurrency + duration (mulga-siv-32)
Diagnostics-only change to surface whether nightly e2e cell-3 / cell-8
DORA timeouts correlate with concurrent Acquire calls on the same
bridge. Tracks per-bridge in-flight count and wallclock duration of each
Acquire; logs WARN on failure with both fields, DEBUG on success.
No behavioural change.
* ci(e2e-nightly): dump cluster journals on failure (mulga-siv-32)
run-multinode-e2e.sh dumps node journals via its own EXIT trap, but
run-cert-e2e.sh / run-lb-e2e.sh / reboot-e2e do not. When those scripts
fail the cluster is destroyed in Teardown without surfacing any daemon
logs, blocking root-cause analysis.
Add a workflow step that runs after the test scripts but before
Teardown when a previous step failed, ssh'ing to each node and pulling
the last 200 lines of every spinifex-* unit. Best-effort: skips
gracefully when inventory or nodes are unreachable.
Diagnostic-only; no behavioural change to the test path.
* fix(setup): mask dhcpcd.service to stop it racing vpcd's DHCP client (mulga-siv-32)
Debian 13 (Trixie) auto-enables a standalone dhcpcd.service when
dhcpcd-base is installed. It binds br-wan and races vpcd's in-process
nclient4 client for upstream OFFERs, draining the lab DHCP pool with
duplicate leases and causing intermittent DORA timeouts in the e2e
public-IP path (worst on cell-8 real-multi/dhcp/debian-13).
The ISO installer already masks the unit at install time
(cmd/installer/install/install.go:316). The binary install path used by
e2e nightly missed it, so debian hosts installed via setup.sh ran with
both DHCP clients live. Mirror the ISO mask here.
Ubuntu hosts are unaffected (dhcpcd-base does not auto-enable
dhcpcd.service on Noble).
* ci(e2e-nightly): also dump dhcpcd.service state on failure (mulga-siv-32)
Confirms or rules out the dhcpcd-vs-vpcd race hypothesis. Pulls the
dhcpcd.service journal alongside the spinifex-* units, plus
systemctl is-enabled / is-active and the DHCP client port (UDP 68)
listener so we can see directly whether dhcpcd is running and bound
to br-wan when an Acquire times out.
---------
Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com>
|
||
|
|
27d7fdd12b | Latest changes re ISO and binary install path | ||
|
|
b591c04880 | firstboot tweaks | ||
|
|
a64ee2b2da | ISO tweaks | ||
|
|
402a04e1b9 | Merge branch 'feat/iso-installer' of github.com:mulgadc/spinifex into feat/iso-installer | ||
|
|
25d02707d0 | ISO tweaks | ||
|
|
7d6e0780b5 | feat: action rate limiting (#140) | ||
|
|
1ad03bb518 | feat(gateway): per-IP auth failure rate limiting (#138) | ||
|
|
a4ae813e38 |
fix: recursive chmod on shared data dirs so existing image files are group-readable
chmod 0770 without -R only affected the top directory; pre-existing files (e.g. images imported while owned by another user at mode 0600) stayed unreadable to the spinifex group, breaking image import on upgrade paths. |
||
|
|
e0118975d1 | fix: setup.sh | ||
|
|
36e3481ca3 | fix: enable spinifex.target so services autostart on boot | ||
|
|
515c313e07 | fix: setup.sh newgrp | ||
|
|
48c90b795a | feat: migration framework (#127) | ||
|
|
e27d909e8d | feat: move NBD sockets to /run/spinifex/nbd/ and enable PrivateTmp (#119) | ||
|
|
9a7e914d28 | feat: awsgw directory (#117) | ||
|
|
a56a2baf1f | feat: privilege separation (#114) | ||
|
|
e5b6204875 | Fix service helper sequence |