Symmetric to the openvswitch-switch ordering: ensures ovn-controller
shutdown waits for spinifex-daemon's instance teardown, the correct
general invariant for VM cleanup since logical port programming
flows through OVN. PR1a flagged this as optional follow-up.
Bead: mulga-siv-20.1
Plan: docs/development/bugs/orphan-tap-on-launch-race.md (PR1a)
systemd reverses After= on shutdown so daemon now runs CleanupTapDevice
while ovsdb-server still answers. Eliminates orphan OVS port left in
conf.db when host reboots — root trigger for "port already exists" on
post-reboot RunInstances. spinifex-vpcd.service already had this; the
daemon unit was missed.
Also pull openvswitch-switch + ovn-controller into spinifex.target Wants
so the platform brings them up explicitly rather than relying on
implicit ordering from spinifex-vpcd alone.
Bead: mulga-siv-20.1
Plan: docs/development/bugs/orphan-tap-on-launch-race.md (PR1a)
setup-ovn.sh's veth branch creates veth-wan-br ↔ veth-wan-ovs but nothing
recreates the kernel interfaces on reboot. OVSDB remembers veth-wan-ovs
as a port on br-ext but the peer is gone — the external path silently
breaks and vpcd falls through to direct mode.
- setup-ovn.sh: write /etc/systemd/network/15-spinifex-veth-wan.{netdev,network}
in the veth branch so systemd-networkd recreates the pair on boot. Add
a single pre-case guard that rips down stale veth persistence + the OVS
port + the kernel veth whenever WAN_BRIDGE_MODE != veth, so mode
transitions are idempotent (D17).
- reset-dev-env.sh: delete the netdev/network units during cleanup so
`make reset` gives a truly clean slate.
- spinifex-vpcd.service: After=systemd-networkd.service openvswitch-switch.service
so vpcd's sanity checks see a populated kernel + OVSDB (D5).
Replaces the sudo-dhcpcd shell-out in ObtainDHCPLease / ReleaseDHCPLease
with NATS request/reply against vpc.dhcp.acquire / vpc.dhcp.release.
The daemon-side IPAM passes its nats.Conn into NewExternalIPAM and
threads hostname (option 12) / vendor-class (option 60) through to
vpcd; ExternalIPAllocation now records LeaseExpiresUnix, DHCPServerID
and HWAddr on DHCP-sourced entries. allocateFromPool is restructured
to acquire the lease once up-front and rely on vpcd's idempotent
Manager for CAS-retry safety; a single release fires only if every
CAS attempt fails. Drops the stdout parser, the per-bridge mutex, and
the parse test.
Systemd: spinifex-daemon loses AF_PACKET, ProtectKernelTunables and
MemoryDenyWriteExecute are restored to =yes; spinifex-vpcd gains
AF_PACKET in RestrictAddressFamilies, AmbientCapabilities=CAP_NET_RAW,
and CAP_NET_ADMIN / CAP_NET_RAW / CAP_NET_BIND_SERVICE in the bounding
set. Net privilege footprint narrows.
See docs/development/bugs/dhcp-allocate-error.md.
Stop ObtainDHCPLease from erroring on hosts where dhcpcd is already
running as a daemon managing br-wan (e.g. server 2). Add -T (test-only
mode) so the invocation does not collide with the host daemon's
control socket on the interface.
Softens ProtectKernelTunables and MemoryDenyWriteExecute in the daemon
unit to accommodate dhcpcd's runtime requirements; both revert when
the in-process Go DHCP client rewrite lands (mulga-989 / mulga-990 /
mulga-991, see docs/development/bugs/dhcp-allocate-error.md).
Interim: leaves the phantom-lease and release-socket-clobber risks
active until the rewrite replaces this path entirely.