Commit Graph

39 Commits

Author SHA1 Message Date
Bryn Mailer f6f3956952 feat: enable viperblock at-rest encryption by default on fresh installs (#323)
* feat: enable viperblock at-rest encryption by default on fresh installs

Fresh installs left nodes.<node>.viperblock.encryption_key_file empty, which
viperblockd treats as legacy cleartext mode. The encryption machinery existed
but the install path never generated a key or set the field.

Provision a cluster-wide viperblock master key in all three fresh-install
flows and render its path into spinifex.toml:

- admin init (single node): generate the key locally.
- admin init --multi-node (leader): generate once, save locally, and
  distribute via the formation server (mirrors IAM master key distribution).
- admin join (joiner): receive the shared key from the leader rather than
  minting its own, so volumes sealed on any node open everywhere. Lenient on
  absence — an older leader returns no key, so the joiner warns and stays
  cleartext instead of failing the join.

The key file is omitted from the template when unset, so upgrades with no
existing key keep running cleartext.

* fix: make viperblock encryption key group-readable for both readers

The key is loaded by two services per node — viperblockd (spinifex-viperblock)
and the awsgw EC2 handlers (spinifex-gw), both in the spinifex group — so it
must be group-readable, not owner-only like the per-node predastore key.

The previous commit generated the key but never registered its path with the
deployment ownership machinery, leaving /etc/spinifex/viperblock as root:root
0700 (non-traversable) and the key as root:root 0600. The daemon failed at
startup with "stat ... permission denied".

Mirror master.key: setup.sh creates /etc/spinifex/viperblock (0750), and
SetServiceOwnership chowns the dir to spinifex-viperblock and promotes the key
to root:spinifex 0640.

* fix: read viperblock config.json through StateBody for encrypted volumes

The metadata layer parsed config.json with json.Unmarshal/NewDecoder directly,
which fails on encrypted volumes/AMIs now that viperblock wraps VBState in a
valid-JSON envelope ({"v":1,"payload":...,"authtag":...}). DescribeImages
silently skipped encrypted AMIs (count=0 → "no AMIs available"), bricking the
whole launch path.

Route every config.json read through viperblock.StateBody, which unwraps the
envelope (no key needed — the metadata is authenticated, not encrypted) and is
a no-op for unencrypted volumes:

- image: DescribeImages, getVolumeConfig, amiNameExists, GetAMIConfig
- volume: getVolumeConfigAndEncryption, and mergeVolumeConfig (so the
  refuse-to-merge-encrypted guard sees the real VBState instead of clobbering
  the envelope with a tag-less blob)
- admin: readAMIConfig, readVolumeConfig
2026-06-15 09:31:23 +10:00
Josh Siviour 2ea3e22db6 feat(systemd): cgroup-confine spinifex to a resource-limited slice + host swap (#324)
* feat(systemd): bound spinifex to a resource-limited slice

Add a spinifex.slice parent ceiling (MemoryHigh=80%, MemoryMax=90%,
MemorySwapMax=0) with a spinifex-system.slice child holding the seven
control/infra services, so a runaway hits the slice instead of the host.
A system.slice drop-in (MemoryMin=1G, CPUWeight=300) reserves RAM and CPU
for sshd/journald/the operator, keeping the box reachable when spinifex is
maxed.

The drop-in is generated in setup.sh install_systemd() rather than shipped
as a staged file, since the packaging globs flatten the systemd/ dir; this
mirrors the existing sshd-keygen drop-in pattern. The two .slice files flow
through every staging path unchanged.

Within the single effective cgroup, a slice MemoryMax OOM picks the highest
oom_score victim — guest QEMU (+500) before any service (-500) — so a slice
OOM degrades by killing one guest while the daemon, storage tier, NATS, and
the host all survive.

* feat(setup): provision 8G host swapfile + vm.swappiness=10

Add a setup_swap stage that creates an 8G /swapfile, enables it, persists it
to fstab, and writes vm.swappiness=10 so the kernel only swaps under real
pressure. Backs spinifex.slice MemorySwapMax so the slice can spill to swap
for graceful degradation instead of OOMing a guest. Idempotent; skipped under
ISO_BUILD (firstboot provisions swap on ISO hosts). Reverses the prior swap=0
assumption.
2026-06-09 15:21:13 +10:00
joshsiv-mulga 41f840ee85 fix(setup): grant spinifex-vpcd sudo for ovn-appctl (siv-167)
The W2 inject-garp fix landed in 72a6a59d adds a shellout to
`ovn-appctl -t ovn-controller inject-garp <port>` via the L0
execRunner, which prefixes `sudo` when not running as root.
spinifex-vpcd runs as user spinifex-vpcd, so every emission was
hitting `sudo: a password is required` and silently returning a
WARN that nobody read until W5 diag capture surfaced the journal.

Net: W2 has been a complete no-op since it shipped. Every
recycled-EIP scenario has continued to leave stale upstream ARP.

Evidence: diag bundle from run 26813235295 — 12/12 GARP attempts
denied by sudo, 0 successful emissions; pcap shows runner ARP for
recycled EIP .232 stuck on the prior VPC's gw chassisredirect MAC
(02:75:d9:ef:d8:4b) while OVN NB has handed .232 to a new VPC
with a different gw MAC; pcap also shows runner sending 174 SYNs
to recycled EIP .233 with 0 SYN+ACKs received.

Fix: add /usr/bin/ovn-appctl to the spinifex-vpcd NOPASSWD grant.
Trivial; ovn-appctl is already trusted via the existing NB/SB
read-write grants.

Follow-ups (separate change): tighten host.InjectGARP error
classification so sudo-deny is loud (Error or fatal) rather than
silently warn-and-continue; add a boot-time self-check that
verifies sudo permissions for every host-tool the daemon will
shell out to.
2026-06-02 21:00:20 +10:00
tomnewton-mulga 9d8597317a Feat/mig capable (#271)
* feat(gpu): add NVIDIA MIG multi-instance GPU support

Partitions MIG-capable GPUs (A100, A30, H100) into isolated slices exposed
as mdev devices instead of whole-GPU VFIO passthrough. VMs attach via
-device vfio-pci,sysfsdev=<mdev-path> using the GPUAttachment discriminated
union (PCIAddress for whole-GPU, MdevPath for MIG).

Key changes:
- gpu: new MIGProfile/MIGInstance types, IsMIGCapable model map, mig.go ops
  (EnableMIGMode, DisableMIGMode, CreateInstances, ListInstances,
  DestroyAllInstances, enrichMdevPaths)
- gpu.Manager: Claim() returns (*GPUDevice, *MIGInstance, error); AddMIGInstances,
  ReclaimByMdev for restart recovery; MarkMIGFailed per-slice
- daemon: buildGPUPool helper partitions devices into whole-GPU vs MIG pools;
  MIGProfile config field selects profile per node or per GPU override
- vm.VM: GPUAttachments []gpu.GPUAttachment replaces GPUPCIAddresses []string
- admin CLI: spx admin gpu mig status/enable/disable subcommands with
  admin.SetMIGProfile for spinifex.toml writes
- docs: COMMANDS.md updated with three new MIG management command rows

* test(gpu): unit tests for MIG parsers and pool manager

Cover all pure parsing functions (parseMIGMemory, isCapacityExhaustedError,
extractProfileFields/GIFields, parseMIGProfiles, parseMIGInstances,
parseCreatedGIID/CIID) with realistic nvidia-smi fixture output.

Manager MIG tests cover AddMIGInstances, Claim/Release on mdev-backed entries,
MarkMIGFailed, ReclaimByMdev, and interaction with whole-GPU MarkFailed — all
using fake mdev directories in t.TempDir() so no GPU hardware is required.

* feat(gpu): dynamic MIG profile-per-request with on-demand GI/CI lifecycle

Replaces static config-driven MIG pre-carving with a dynamic model where
the MIG profile is specified per RunInstances call via mig.<profile>
instance type names (e.g. mig.1g.10gb) that mirror nvidia-smi nomenclature
directly.

- Manager.Claim(instanceID, profileName): fast path claims a pre-carved
  slice; slow path dequeues a free MIG GPU, releases the lock, calls
  nvidia-smi mig -cgi/-cci to carve all slices, then reclaims the lock to
  commit and return the first slice
- Manager.Release: last release on a dynamically-carved GPU calls
  DestroyAllInstances and returns the GPU to freeMIGGPUs, allowing a
  different profile on the next claim
- AddMIGGPU(dev): registers a fresh MIG GPU for dynamic allocation;
  AddMIGInstances (restart recovery) keeps its no-destroy semantics
- GenerateMIGTypes: produces mig.<profile> InstanceTypeInfo entries from
  gpu.ListProfiles at daemon startup; IsMIGType/MIGProfileFromType let
  callers inspect these names
- buildGPUPool: calls ListInstances for recovery, AddMIGGPU for fresh
  GPUs, ListProfiles to collect MIG profile specs for type generation;
  removes setupMIGInstances and migProfileForDevice
- GPUClaimer.Claim gains profileName param; daemonGPUClaimer, service_impl
  call sites, and fakeGPUClaimer all updated

* fix(gpu): correct mdev parent detection and make --profile optional for mig enable

enrichMdevPaths was using os.Readlink on "parent_bus_0" (a non-existent
sysfs attribute) and then on ".." (a directory, not a symlink) — both
would fail on real NVIDIA hardware, breaking CreateInstances and
ListInstances on daemon restart recovery. Fix: read the mdev UUID's own
symlink target, which always encodes the parent GPU's PCI address in its
path (e.g. .../0000:01:00.0/<uuid>).

Make basePath injectable in enrichMdevPaths so the fix is covered by a
new set of unit tests using temp-dir symlinks (TestEnrichMdevPaths_*).

Remove the MarkFlagRequired("profile") from "spx admin gpu mig enable":
Phase 2 is fully dynamic — the daemon carves slices on demand at
RunInstances time. Without --profile, the command just enables MIG mode
and destroys any pre-carved slices so the daemon starts with a free GPU.
With --profile, behaviour is unchanged (pre-carve a static pool).

* chore: writeups for smci and arcee

* test: add coverage for MIG exec, manager slow-path, instancetypes and admin

- Add mig_exec_test.go with fake nvidia-smi harness covering Enable/Disable MIGMode,
  IsMIGModeEnabled, DestroyAllInstances, ListProfiles, CreateInstances, ListInstances
- Extend manager_mig_test.go with slow-path Claim/Release tests using fake nvidia-smi
- Add generate_test.go coverage for IsMIGType, MIGProfileFromType, GenerateMIGTypes
- Add admin_test.go coverage for SetMIGProfile (create, update, idempotent, error paths)
- Make mdevBasePath a var to allow sysfs injection in tests
- Add json tags to GPUAttachment fields to satisfy musttag linter

Diff coverage: 75.6% (threshold: 60%).

* fixed gpu passthrough doc

* Revert "fixed gpu passthrough doc"

This reverts commit 1e20f5ab13.

* feat: Added RTX 6000 GPU MIG support and fixed docs

* feat: expose GPU/MIG inventory in GetNodes and GetVMs admin API

Add Manager.Snapshot() for lock-safe pool inspection. Extend
NodeStatusResponse with GPUs []GPUInfo (per-physical-GPU inventory
with per-slice detail for MIG) and VMInfo with GPU *VMGPUInfo
(model, VRAM, profile, mdev path for the attached GPU). Populate
both in handleNodeStatus and handleNodeVMs via buildGPUInventory,
buildPoolLookup, and resolveVMGPU helpers.

* feat: surface GPU info on EC2 instance detail page (mulga-new-03)

Admin users see a GPU card (model, VRAM, attachment type, MIG profile/mdev
path or PCI address) populated from the GetVMs admin API.  Adds formatVRAMMiB
helper and VMGPUInfo/GPUInfo/GPUSliceInfo types to the frontend.

* feat: GPU columns + inventory card on Nodes page (mulga-new-04)

Adds GPU column to VMsTable (model/VRAM or MIG profile) and ResourceTable
(alloc/total GPUs). Section 4 GPU Inventory card shows per-node GPU state with
per-slice MIG drill-down. Also adds total_gpus/alloc_gpus to NodeInfo type.

* feat: grouped GPU-aware instance type picker in Run Instances (mulga-new-05)

Splits the flat instance type dropdown into Standard and GPU-Accelerated groups.
GPU items show total VRAM alongside the type name. Selecting a GPU type surfaces
an info line with GPU name and VRAM.

* testing image builder scripts

* fixed nvidia build script

* more descriptive errors for image build script

* more fixes

* more fixes

* fix: surface PCI address in whole-GPU VMGPUInfo and rebuild frontend dist

Add PCIAddress to VMGPUInfo, populate it in resolveVMGPU for whole-GPU
passthrough, and fix the instance detail page which was incorrectly
showing instance type in the PCI address field. Rebuilt frontend dist
to include GPU UI changes (inventory card, resource columns, GPU-aware
instance type picker).

* fix: improve kernel version detection in nvidia image build script

Fall back to /lib/modules when /boot/vmlinuz-* is absent, and add
diagnostic output to help debug kernel detection failures.

* fixing nvidia image build script

* fix ami name issue

* correct kernel versions

* another fix

* image build works, added docker and nvidia toolkit for QoL

* fix: add gpg

* fixing amd image builder

* add universe

* another fix

* nvm

* fix docker user group issues

* make rocm land where it is supposed to

* fix docker groups

* feat: add Ubuntu 26.04 GPU AMI catalog entries and fix build script parted detection

Add ubuntu-26.04-nvidia-gpu-x86_64 and ubuntu-26.04-amd-gpu-x86_64 to AvailableImages,
hosted on iso.mulgadc.com/system-ami/ with SHA256 checksums. Fix build-system-image.sh
to detect parted in /usr/sbin when not on PATH. Suppress gosec false positives in DHCP
manager (cancel stored in leaseLoop) and promisc ioctl (standard syscall uintptr pattern).

* Updated passthrough doc regarding GPU images

* fix: remove orphaned nolint directives (golangci-lint v2.12.2 no longer flags G115/G118)

* chore: remove stale spinifex@192.168.3.107 directory

Scripts were accidentally committed with a node hostname as the path
prefix during initial testing. Correct copies live in scripts/images/.
2026-06-01 13:48:13 +10:00
Josh Siviour fd3dc6b680 feat(network): ADR-0006 layer redesign + IPsec/OVN hardening (#255)
* refactor(vpcd): remove macvlan bridge mode

Macvlan was a single-NIC SSH-safe hack that predated veth mode and was
never selected by any active config path. Deletion is Phase 0 item 1 of
the network layer redesign (mulga-siv-125.1).

Removed:
- BridgeModeMacvlan const + setMacvlanMAC + ifaceIsMacvlan probe
- Macvlan MAC alignment block in launchService (only fired on dead path)
- Macvlan branch in detectBridgeMode + matching tests
- Macvlan duplicates of IGW/AddNAT centralized-NAT tests (veth versions
  already cover the same path)
- --macvlan flag + macvlan case branch in setup-ovn.sh

Refactored:
- useCentralizedNAT() now == BridgeModeVeth (was != BridgeModeDirect);
  verifyBridgeMode already rejects empty/unknown at startup
- Three IGW-pool tests now explicitly WithBridgeMode(BridgeModeVeth)
  (previously relied on empty-mode defaulting to centralized)

Kept intentionally:
- Deprecation notes in docs/compute/vpc-networking/README.md
- Legacy macvlan-interface cleanup in reset-dev-env.sh + ansible
  teardown role (migration for operator systems with stale spx-ext-*
  interfaces from pre-veth installs)

* feat(vpcd): resolve external CIDR at startup with bounded retry

Block service start until the WAN bridge has an IPv4 address, with a 30s
retry window. Phase 0 item 2 of the network layer redesign
(mulga-siv-125.1). Guards the boot race where vpcd starts before
systemd-networkd finishes DHCP on br-wan, or before netplan applies a
static config.

Skipped when ExternalMode is empty (overlay-only deployments).

Forward-compatible with ADR-0006: the new resolveExternalCIDR /
externalCIDRFromBridge helpers become the backing implementation of
HostWiring.ExternalCIDR() once the network/host package lands in Phase 1.
Until then the resolved value is only used to fail-start on missing
uplink.

* fix(vpcd): cover external CIDR startup paths

Extract launchService's CIDR-resolve block to ensureExternalCIDRReady
helper so it's unit-testable, and add direct tests for
externalCIDRFromBridge (loopback + unknown-interface) to exercise the
original literal body. Closes the diff-coverage gap on Phase 0 commit
15b564d which left these paths unreachable from unit tests.

* refactor(network/ovn): extract L1 OVN client to network/ovn package

Move OVNClient interface, LiveOVNClient, ACLSpec, ErrNATNotFound and
namedUUID helper from services/vpcd to a new spinifex/network/ovn
package. The mock relocates to spinifex/network/ovn/mock as a
sub-package. Storage fields on the mock become exported so vpcd tests
can continue to seed/inspect state across the new package boundary.

services/vpcd retains thin type-alias and var-alias shims so existing
callers compile unchanged; Phase 2 removes those shims as vpcd is torn
down.

Adds -coverpkg=./spinifex/... to test-cover so cross-package test
exercise of mock methods continues to count toward coverage now that
the mock lives outside vpcd.

First sub-step of Phase 1 of docs/development/feature/spinifex-network-redesign.md
(bead mulga-siv-125.2). Pure refactor; no functional change. All
existing tests pass; preflight green.

* feat(network/topology): TopologyManager interface + vpcd adapter

Add spinifex/network/topology with Manager interface, VPC/Subnet/Port
specs, and OVN object naming helpers covering the L2 stable contract
(§7 of the redesign plan). Phase 1 keeps existing in-tree OVN names
(rtr-, ext-port-, sg_) and notes the §7.3 targets for a later
reconciliation migration.

TopologyHandler in services/vpcd grows EnsureVPC / DeleteVPC /
EnsureSubnet / DeleteSubnet / EnsurePort / DeletePort /
SetPortSecurityGroups methods that mirror the corresponding NATS
handlers' OVN ops with Spec inputs instead of nats.Msg envelopes,
satisfying topology.Manager via a compile-time check. Existing handlers
are unchanged; the duplication is short-lived (Phase 2 collapses them).

Smoke tests in topology_manager_test.go cover the idempotent create
path, delete cascade, and declarative SG membership move. Deliverable:
TopologyManager.EnsureVPC/Subnet/Port callable; all existing tests
green.

Second sub-step of Phase 1 of docs/development/feature/spinifex-network-redesign.md
(bead mulga-siv-125.2).

* feat(network/host): L0 HostWiring interface + physical/veth impls

Phase 1 deliverable for mulga-siv-125.2. Introduces network/host (L0 of
ADR-0006): UplinkMode enum, Wiring interface, and Physical/Veth
implementations with injectable Runner + InterfaceReader for testability.
Not yet wired into daemon/vpcd — Phase 2 replaces daemon.SetupComputeNode
and vpcd's resolveExternalCIDR with calls through this package.

* feat(network/policy): L3 SecurityGroup/NAT/Route managers

Introduce network/policy as the data-plane policy layer (ADR-0006 L3).
Three managers, all backed by network/ovn:

- SecurityGroupManager: clear+add ACL replacement on an existing port
  group; port group lifecycle stays with L2 (topology.Manager).
- NATManager: bound to one NATMode at construction (derived from
  host.UplinkMode). Distributed sets logical_port/external_mac on EIP
  dnat_and_snat rules; centralised leaves them unset. Per-EIP, NAT GW,
  and IGW-default SNAT entrypoints; all deletes idempotent.
- RouteManager: AddStaticRoute is read-then-decide so retries no longer
  duplicate rows (closing the long-standing non-idempotency bug in
  vpcd/topology.go's IGW default-route path).

ACL priority constants and infrastructure ACL builders move from
vpcd/{security,acl}.go into policy/acl.go with their semantics preserved
(default-deny 900/800 logged, DHCP-allow 1050, tenant 1000). No vpcd
wiring changes here — additive only; the reconciler (bead .3.2) and
network/external (bead .3.4) will consume these managers.

bead: mulga-siv-125.3.1

* feat(network/external): L5 IGW/EIP/NATGW managers

Pure additive — new package, no topology.Manager changes, no rewiring of
existing vpcd handlers. IGWManager builds the external switch + localnet +
gateway LRP + default route + chassis HA, with a flows barrier callers can
inject (production: ovn-nbctl --wait=hv sync). EIP/NATGW are thin L5
wrappers over policy.NATManager. GatewayIPAllocator interface lets the
DHCP-backed allocator stay in vpcd until the DHCP-mgr removal bead lands;
LinkLocalAllocator + StaticRangeAllocator ship here.

* feat(network/reconcile): L6 intent-actual reconciler replaces 5-pass startup

Build spinifex/spinifex/network/reconcile/ package per Phase 2.2 of the
network layer redesign. Reads desired state from NATS KV filtered by
vpc.AZ (with legacy empty-AZ matches-all rule), scans actual state from
OVN NB DB, diffs and applies with VPC → Subnet → Port → SG → IGW →
EIP/NATGW topological ordering.

Atomic port-group join via CreateLogicalSwitchPortInGroups closes the
racy gap the legacy scanENIPortMembership pass used to revive 30s later.
A 5-minute drift goroutine (leader-gated via JetStream KV CAS) replaces
the old 30s ReconcileSGsLoop.

Adds AZ field to VPCRecord stamped at create time. Empty AZ on pre-Phase
2.2 records matches every local AZ, so no migration pass is required.

Replaces and removes the 5-pass startup sequence in services/vpcd:
  - Reconcile + ReconcileFromKV
  - ReconcileSGsOnce + ReconcileSGsLoop
  - RetrofitAllExternalLocalnetOptions
  - RetrofitAllGatewayPortNetworks

IGW fresh-create continues to flow through the legacy NATS handler path
(handleIGWAttach) so the dhcpManager wiring stays intact until Phase
2.3; the reconciler only rebinds gateway-chassis on existing IGW
topology.

Closes mulga-siv-125.3.2.

* refactor(network/topology): promote live Manager impl to network/topology

Move the topology.Manager implementation out of services/vpcd/topology_manager.go
into network/topology/manager_live.go as a standalone liveManager constructed
via NewLiveManager(ovn.Client, opts...). Inputs that varied per-handler
(DNS server resolution from the external pool) are now passed as functional
options (WithDNSServer).

TopologyHandler still satisfies topology.Manager but its methods delegate
to a cached liveManager. The shim stays until the rest of mulga-siv-129
routes NATS subscribers through topology.Manager directly.

Also exports SubnetGatewayCIDR + FormatDNSServerList from network/topology
so the reconciler in network/reconcile can share helpers with the live
manager (audit pass to follow per plan §6).

Test cases ported one-for-one from services/vpcd/topology_manager_test.go
to network/topology/manager_live_test.go; the vpcd-side test file is
deleted. New WithDNSServer test asserts the option propagates into
DHCPOptions rows.

Refs mulga-siv-129 (Phase 2.6 vpcd subscriber migration, Slice 1 of N).

* refactor(vpcd): collapse SG subscribers onto network/{topology,policy} managers

Phase 2.6 / mulga-siv-129 slice 2. Rewrites the vpc.create-sg /
vpc.update-sg / vpc.delete-sg NATS subscribers in services/vpcd as
thin wrappers over topology.Manager (port group lifecycle) and
policy.SecurityGroupManager (ACL programming). Deletes the ~1000
lines of duplicated ACL builder and provisioning logic — its
authoritative copy lives in network/policy.

Surface additions:

- ovn.ErrPortGroupNotFound sentinel; mock + live GetPortGroup wrap
  not-found via fmt.Errorf("%w: ...") so callers can use errors.Is.
- topology.Manager grows EnsureSGPortGroup / DeleteSGPortGroup
  (resolves the apply.go TODO from §2.1 of the redesign plan).
  liveManager implements them with GetPortGroup-then-Create /
  GetPortGroup-then-Clear+Delete idempotency.

Behaviour delta: the old provisionSG rolled back the OVN port group
on AddACLs failure ("all-or-nothing"). The new path lets the port
group survive and relies on network/reconcile to retry EnsureSG on
its next sweep. The all-or-nothing fail-fast test cases are dropped;
ACL emission semantics are covered by network/policy/sg_test.go.

* refactor(vpcd): migrate VPC/Subnet/ENI subscribers to topology.Manager

Phase 2.6 / mulga-siv-129 slice 3. Rewrites vpc.create / vpc.delete /
vpc.create-subnet / vpc.delete-subnet / vpc.create-port /
vpc.delete-port / vpc.update-port-sgs NATS subscribers as thin
wrappers (≤30 lines each) over topology.Manager. Subscriber bodies
now: parse event → translate to spec → delegate to manager.

Deletes:

- vpcd.subnetGateway (and helpers_test.go + topology_test.go's
  TestSubnetGateway block); parity coverage lives in
  network/topology.TestSubnetGatewayCIDR.
- vpcd.reconcilePortSGs (the live manager already exposes the same
  diff-then-transact via reconcilePortSGs on the L2 side).
- vpcd.TopologyHandler.dnsServer; lmDNSServer (passed via
  topology.WithDNSServer to the live manager) is the live path.

Behaviour delta: handlers now strict-parse PrivateIpAddress /
MacAddress / CidrBlock at the NATS boundary and reject malformed
payloads instead of degrading to "no DHCP options". The reconciler
guarantees that field validity is upheld upstream of the publish.

* refactor(network/reconcile): drive SG port groups via topology.Manager

applySGs now calls topology.Manager.EnsureSGPortGroup /
DeleteSGPortGroupByName instead of reaching directly into the OVN client.
Reconcile.Config gains a Topology field (required); the production caller
in services/vpcd passes the TopologyHandler shim, the reconcile package
tests construct a fresh topology.NewLiveManager bound to the mock OVN
client.

DeleteSGPortGroupByName is added to the topology.Manager interface for the
reconciler's orphan-removal path, which iterates raw OVN port-group names
without a groupID round-trip. The existing DeleteSGPortGroup(groupID)
delegates to it.

Resolves the TODO at apply.go:137 carried over from slice 2 of
mulga-siv-129.

* feat(network/policy): add FlowsBarrier option to NATManager

NATManager.AddEIP needs to block on `ovn-nbctl --wait=hv sync` after
writing the dnat_and_snat row so the NATS reply only returns once every
chassis has the rewrite flow. The legacy vpc.add-nat handler does this at
the tail of handleAddNAT; the manager has lacked it since slice 2.1.

NewNATManager grows a functional-options tail (Option / WithFlowsBarrier).
Defaults to a no-op for tests; production wiring in services/vpcd passes
waitForFlowsHV. AddEIP now invokes the barrier after AddNAT, logging at
warn level on failure to match the legacy handler's _ = waitForFlowsHV()
swallowing semantics.

Pre-work for slice 4 of mulga-siv-129 — without the barrier the NAT EIP
subscriber migration would lose the post-write flow-install gate.

* refactor(vpcd): migrate NAT GW subscribers to policy.NATManager

handleAddNATGateway / handleDeleteNATGateway now decode the NATS event
and delegate to policy.NATManager.{AddNATGateway,DeleteNATGateway}. The
manager carries identical OVN logic — same snat type, same ExternalIDs
(spinifex:vpc_id + spinifex:nat_gateway_id) — so existing
TestTopologyHandler_AddNATGateway / DeleteNATGateway suites stay green.

Lazy-constructed NATManager added on TopologyHandler (natmOnce). Mode is
derived from the bridge mode (veth → centralized, direct → distributed)
and the FlowsBarrier is bound to waitForFlowsHV for parity with the
legacy EIP path's tail barrier (used by the next slice, vpc.add-nat).

Slice 4 of mulga-siv-129, sub-step b.

* refactor(vpcd): migrate EIP NAT subscribers to policy.NATManager

handleAddNAT / handleDeleteNAT now decode the NATS event and delegate to
policy.NATManager.{AddEIP,DeleteEIP}. The behavioural contract is
preserved end-to-end:

- Idempotency-skip on a matching dnat_and_snat row (same VPC + LogicalIP,
  plus MAC + LogicalPort under distributed NAT) moves into AddEIP so
  duplicate vpc.add-nat publishes never tear down the rule the previous
  invocation just installed (mulga-siv-124).
- Stale-rule cleanup across every router stays in AddEIP.
- Post-write waitForFlowsHV barrier is now driven by the manager via the
  FlowsBarrier option wired in services/vpcd (slice 4a).
- DeleteEIP returns nil on ErrNATNotFound, matching the handler's
  fire-and-forget "already absent = success" semantic.

The vpcd "errors" import drops out with the inline error-comparison.

Slice 4 of mulga-siv-129, sub-step c.

* refactor(vpcd): migrate IGW subscribers to external.IGWManager (partial)

handleIGWAttach now branches at decode time:
- Centralised NAT + DHCP-sourced pool keeps using attachIGWLegacy because
  the gateway-LRP IP comes from vpc.dhcp.acquire, and that DHCP client is
  the vpcd-local manager that bead mulga-siv-125.3.3 will retire.
- All other shapes (distributed NAT, static-range pool, no pool)
  delegate to external.IGWManager.AttachIGW. The manager mirrors every
  step the legacy handler ran — external switch + localnet port +
  gateway LRP + switch-side router peer + default route + chassis HA +
  waitForFlowsHV tail barrier — so observable behaviour is unchanged.

handleIGWDetach drops its inline OVN walk entirely; both paths exit
through external.IGWManager.DetachIGW followed by releaseGatewayLRPLease.
The lease release stays in vpcd because the upstream client lives in
services/vpcd/dhcp; calling it after every detach is safe because the
upstream server expires unknown leases on its own.

Lazy-constructed IGWManager added on TopologyHandler (igwmOnce). Pool,
allocator (StaticRangeAllocator), chassis, NAT mode, NAT manager, route
manager, and FlowsBarrier are all derived from the existing
TopologyHandler state.

The DHCP-coupled legacy branch retains its full inline OVN logic; it
will disappear in slice-after-125.3.3 follow-on. Slice 4 of
mulga-siv-129, sub-step d.

* feat(ec2/instance): honor AssociatePublicIpAddress per-NIC override

RunInstances --network-interfaces "AssociatePublicIpAddress=true|false"
was silently ignored, only subnet.MapPublicIpOnLaunch gated public IP
assignment. AWS contract is per-NIC override wins.

Extend TestPrepareRunInstances_PublicIPAutoAssigned to table-driven
3 cases: subnet true no-override, subnet false override true, subnet
true override false.

* refactor(config): drop upstream-DHCP config surface (static WAN pool only)

Hard-error in LoadConfig on legacy keys: [network] external_dhcp,
[nodes.<n>.vpcd] dhcp_bind_bridge, and [[network.external_pools]]
source = "dhcp". Add pool range validation (must fit inside the
gateway/prefix_len CIDR; per-cluster non-overlap).

Strip ExternalDHCP from config.NetworkConfig + formation.NetworkConfig
+ admin.ConfigSettings, and DhcpBindBridge from config.VPCDConfig +
admin.ConfigSettings + vpcd.Config. vpcd.ExternalPoolConfig.IsDHCP()
short-circuits to false; the field and downstream DHCP branches in
external_ipam / topology.go remain for Slice C to delete together with
dhcp_manager.

cmd/spinifex/cmd/admin.go: drop useExternalDHCP path and the
detectedDhcpBindBridge helper; require --external-pool when
--external-mode=pool; auto-detect default no longer infers source=dhcp.

service.go's wan_bridge legacy-key rejection now advises removing the
key entirely (vpcd auto-detects br-wan), not renaming to
dhcp_bind_bridge.

Two topology_test cases that exercise the DHCP gateway-LRP path are
skipped — Slice C deletes attachIGWLegacy and these tests together.

* refactor(vpcd): delete dhcp_manager + DHCP gateway-LRP path (Slice C)

Removes upstream-DHCP-client gateway-LRP allocation in favor of static
WAN-pool allocation (StaticRangeAllocator). Part of bead mulga-siv-125.3.3.

- delete services/vpcd/dhcp_manager.go + dhcp/ subpackage (~865 lines)
- delete allocateGatewayLRPIPViaDHCP + releaseGatewayLRPLease paths
- drop ExternalPoolConfig.Source + DhcpBindBridge + IsDHCP() fields
- drop ExternalIPAllocation lease fields (Expiry/ServerID/HWAddr) and
  ExternalIPAMRecord.Source
- drop NewExternalIPAM nc *nats.Conn argument; update all 4 call sites
- rename verifyBridgeMode local dhcpBindBridge -> wanBridge; update error
  strings and tests

Slice D (delete attachIGWLegacy + dispatcher) intentionally deferred.

* refactor(vpcd): delete attachIGWLegacy + IsDHCP stub (Slice D)

Closes mulga-siv-129 slice 4d. Part of bead mulga-siv-125.3.3.

handleIGWAttach now unconditionally delegates to external.IGWManager.
attachIGWLegacy (~207 lines, ~5 OVN write steps + chassis scheduling)
deleted along with its dispatcher branch in handleIGWAttach. The
ExternalPoolConfig.IsDHCP() dead stub is gone.

No code paths or NATS subjects regress: the static-pool / distributed
branches were already going through external.IGWManager since Slice 4d
(6719dc3).

* feat(ipam): Purpose field on every IPAM record (Slice B)

Part of bead mulga-siv-125.3.3.

Adds a Purpose enum (handlers/ec2/vpc/purpose.go) tagging every IP
allocation with its semantic role (eni-primary, eni-public, eip,
igw-lrp, natgw-external, …) so multi-VPC clusters can reclaim/audit
by (owner, purpose).

External IPAM (spinifex-external-ipam, v1→v2):
- ExternalIPAllocation.Type → .Purpose; legacy values mapped via
  LegacyExternalTypeToPurpose (gateway→igw-lrp, auto_assign→eni-public,
  elastic_ip→eip). Unknown legacy values warn and become "unknown".
- AllocateIP / AllocateFromPool / allocateFromPool param rename
  allocType→purpose. All call sites pass Purpose* constants.
- migrate/002_external_ipam_purpose.go: idempotent CAS-retry migration
  with v1/v2-union record shape so partial migrations resume cleanly.

Internal IPAM (spinifex-vpc-ipam, v1→v2):
- IPAMRecord.Allocated []string → []IPEntry{IP, Purpose, OwnerID}.
- AllocateIP gains purpose+ownerID args; ReleaseIP unchanged (still
  keyed on IP).
- AllocatedIPs returns []IPEntry.
- eni.go reorders eniId generation before AllocateIP so the owning
  resource ID lands on the new entry.
- migrate/003_ipam_purpose.go: cross-bucket backfill that reads the
  ENI bucket via the new RunKVWithJetStream path. Orphaned IPs
  (no owning ENI) warn and become Purpose=unknown.

Migrate framework:
- KVContext gains an optional JetStream field; new
  Registry.RunKVWithJetStream method threads it through. RunKV
  signature unchanged — all other callers are unaffected.

Tests:
- ipam_test.go: AllocateIP signature updates; AllocatedIPs now asserts
  IP / Purpose / OwnerID on the returned entries.
- external_ipam_test.go: replaces "auto_assign"/"elastic_ip" literals
  with PurposeENIPublic/PurposeEIP and asserts alloc.Purpose.
- migrate/002 + 003 tests: schema-detect, idempotent rerun,
  no-JetStream fallback, empty bucket.

* refactor(daemon): tombstone obsolete spinifex-dhcp-leases KV bucket

The dhcp_manager removed in Phase 2.3 (bead mulga-siv-125.3.3) owned the
spinifex-dhcp-leases KV bucket. The migrate framework only handles
per-bucket schema version bumps, not bucket deletion, so the obsolete
bucket would linger on upgraded clusters.

Add a one-shot tombstone after initJetStream that deletes the bucket if
present. DeleteKVBucketIfExists treats ErrBucketNotFound and
ErrStreamNotFound as success, so the call is idempotent across restarts.

* feat(config): add network.ipsec_enabled cluster flag (default true)

Add IPSecEnabled to NetworkConfig in both the cluster TOML schema and
the formation handshake payload. Default true so AWS-parity intra-AZ
encryption is on by default. Operators can flip false in
[network] for trusted single-rack lab topologies.

Phase 2.5 (bead mulga-siv-125.3.5) consumes the flag from admin init
(strongSwan provisioning), formation server (propagates to joiners),
and daemon startup (ovs-vsctl ipsec_encapsulation toggle).

* feat(admin): IPsec peer cert generator signed by cluster CA

Add GenerateIPSecPeerCert + IPSecCertPaths in spinifex/admin so admin
init (and the future admin add-node path) can issue per-node IKEv2 peer
credentials signed by the existing cluster CA. The cert carries
id-kp-ipsecIKE (RFC 4945) so strongSwan accepts it as an IKEv2 peer
credential when ovs-monitor-ipsec materialises tunnel configs.

Cluster CA is reused directly — no intermediate strongSwan PKI today;
when intermediate CAs land that becomes a separate workstream.

The cert/key pair lives under {configDir}/ipsec/peer.{pem,key}; the
daemon points OVS Open_vSwitch.other_config (certificate, private_key,
ca_cert) at these paths when network.ipsec_enabled is true.

* feat(admin): wire IPsec peer cert into admin init + join paths

Add --ipsec bool flag (default true) on adminInitCmd. Single-node init
and the multi-node leader path both emit an IPsec peer cert after the
existing CA+server-cert generation. The multi-node formation server
propagates the IPSecEnabled flag to joining nodes via NetworkConfig;
admin join honours it and emits its own peer cert during the same
cert-issuance step that already produces the server cert.

spinifex.toml template gains an unconditional [network] block carrying
ipsec_enabled so the value is visible to operators on every install
regardless of whether external networking is configured. The daemon
reads it via cluster config (NetworkConfig.IPSecEnabled).

Bead mulga-siv-125.3.5.

* build: install openvswitch-ipsec for OVN native IPsec

openvswitch-ipsec provides ovs-monitor-ipsec, which reads the
Open_vSwitch.other_config cert/key/CA pointers and materialises
strongSwan configs for every Geneve tunnel managed by ovn-controller.
Pulls in strongswan + strongswan-pki as transitive deps.

Required by bead mulga-siv-125.3.5.

* feat(daemon): enable OVN native IPsec on intra-AZ Geneve at startup

When network.ipsec_enabled is true (default), the daemon points the
local OVS DB other_config at the per-node IPsec peer cert that admin
init / admin join provisioned (configDir/ipsec/peer.{pem,key} + the
cluster CA at configDir/ca.pem), then sets
other_config:ipsec_encapsulation=true.

ovs-monitor-ipsec (shipped by the openvswitch-ipsec package) consumes
those pointers and materialises strongSwan configs for every Geneve
tunnel ovn-controller programs — including OVN-IC inter-AZ tunnels
when federation lands in Phase 3a.

Missing cert files log a warning and leave Geneve plaintext; operators
upgrading an older cluster reissue certs via spx admin to close the
gap.

Bead mulga-siv-125.3.5.

* test(e2e): multinode IPsec wiring + xfrm SAs + ESP capture

TestMultinodeIPSec asserts:
- OVS DB on every node carries certificate/private_key/ca_cert pointers
  and other_config:ipsec_encapsulation=true (what daemon.enableOVNIPSec
  writes).
- ip xfrm state on every node has at least one AEAD SA in AES-GCM mode
  (rfc4106(gcm(aes)) or gcm(aes)) within 90s.
- tcpdump catches ESP (ip proto 50) on the underlay (best-effort —
  logged only; geneve may be idle during the 5s capture window).

Skips cleanly when the cluster was bootstrapped with --ipsec=false
(no ipsec_encapsulation key on first node).

Read-only over SSH; runs in the parallel bucket alongside the other
non-mutating multinode tests.

* fix(igw): write attachment State="attached" for AWS parity

Reconciler intent loader (network/reconcile/intent.go::loadIGWs) filters
IGW records with `State == "attached"`, but AttachInternetGateway was
writing `State = "available"`. The reconciler therefore never picked up
any attached IGW — `intent_igws=0` on every pass — so the OVN external
switch + gateway LRP + WAN bridge wiring built by IGWManager.AttachIGW
never ran for default-VPC IGWs (whose live `vpc.igw-attach` publish at
daemon bootstrap is lost — vpcd subscriber not yet wired).

Net effect on single-node e2e: every SSH probe to 192.168.x public IPs
timed out (TestSSHProbe, TestModifyInstanceAttribute, TestRebootInstance,
TestNATGateway, TestSGToSGDatapath) because SNAT/DNAT rules on the VPC
router had no path to the external network.

Match AWS InternetGatewayAttachment.State semantics:
 - Attach: State="attached"
 - Detach: State="detached"

Detach value is internal — recordToEC2 gates Attachments on VpcId != "",
so the detached State is never surfaced to API consumers.

Bead: mulga-siv-131

* fix(reconcile): call AttachIGW when IGW topology missing

applyIGWs previously deferred to the NATS handler when an intent IGW
had no external switch in OVN. When the vpc.igw-attach event is lost
(bootstrap-time default-VPC IGW published before vpcd subscriber is
ready), deferral never resolves and VM public-IP traffic dies.

Call IGWManager.AttachIGW directly — it is idempotent (short-circuits
when the external switch already exists), so the reconciler converges
default-VPC IGWs on first pass without duplicating work on subsequent
passes.

Closes mulga-siv-132.

* fix(test): align NewExternalIPAM call with 2-arg signature

Rebase onto dev pulled in daemon_system_instance_test.go which used
the legacy 3-arg NewExternalIPAM(jsNC, js, pools). The feature branch
already narrowed the signature to (js, pools) via the upstream-DHCP
config drop; align the test with the current signature.

* fix(vpcd): EnsureSubnet must EnsureVPC first to avoid NATS race

vpc.create-vpc and vpc.create-subnet are independent NATS events with
no inter-event ordering guarantee. Tenant bootstrap on iam.account.created
publishes both within <1ms, so the subnet handler's
CreateLogicalRouterPort can race the parent VPC's CreateLogicalRouter and
fail with "logical router not found". The cascade fails CreateNetworkInterface
which fails RunInstances which surfaces as InsufficientInstanceCapacity to
the SDK — masking the underlying topology race.

handleSubnetCreate now calls EnsureVPC(VPCID-only) before EnsureSubnet.
EnsureVPC short-circuits on existing LR (idempotent), so the race-winning
vpc.create-vpc handler's full CIDR/VNI ExternalIDs are preserved; if subnet
wins the race the LR is created with bare ExternalIDs (cosmetic) and the
follow-on vpc.create-vpc short-circuits.

Adds TestIntegration_SubnetBeforeVPC regression covering both orderings.

Closes mulga-siv-133.

* feat(ansible): require --external-pool, drop NAT, forward EXTRA_VARS

spx admin init now rejects --external-mode=nat and demands --external-pool
when mode=pool. The ansible init role silently skipped pool flags when the
range was unset, so installs fell over inside the spx validator. Make
targets also swallowed `-e` (make's env-override flag), so operators could
not override pool start/end without editing defaults.yml.

- vars/defaults.yml: rename nat_gateway_ip → external_gateway_ip; add
  spinifex_external_no_external opt-out; document the spx flag contract.
- roles/init/tasks/main.yml: drop NAT branch; assert pool range upfront
  with a fail_msg pointing at EXTRA_VARS / defaults.yml; emit gateway,
  prefix-len, gateway-ip only when explicitly set (let spx auto-detect);
  honour --no-external.
- playbooks/dev-reset.yml: rename captured var; coerce legacy
  external_mode=nat to pool with a warn; tighten gateway regex with \b.
- Makefile: ansible-dev-* targets now forward EXTRA_VARS="key=val ..."
  through --extra-vars so `make` callers can override without editing
  defaults.yml.
- scripts/ansible/README.md: document pool requirement, both invocation
  styles (direct -e vs make EXTRA_VARS), NAT removal.

* fix(ipsec): guard ipsec_encapsulation on ovs-monitor-ipsec liveness

enableOVNIPSec set OVS cert pointers + ipsec_encapsulation=true without
ensuring ovs-monitor-ipsec.service was running. Without that daemon, OVS
holds the cert pointers unused, strongSwan never gets IKE config, and
tunnel traffic ovn-controller marks for encryption gets silently
dropped. TestMultinodeIPSec fails on `node1 xfrm has no AEAD SAs`.

- systemd: spinifex-daemon Wants=/After= ovs-monitor-ipsec.service
- daemon: ensureOVSMonitorIPSecActive — systemctl enable --now +
  is-active poll; refuses to flip ipsec_encapsulation if daemon is dead
- daemon: single-node short-circuit — no peers means no tunnels means
  the flag is at best inert and at worst load-bearing-silent-drop
- ci: capture-net-diag.sh + workflow steps to snapshot OVS/OVN/xfrm
  state on failure, fan out across all 3 multinode nodes

Refs: mulga-siv-136

* test(e2e): sticky-skip downstream SSH tests when probe fails

When TestSSHProbe times out (3 min, typically because of mulga-siv-134
datapath bug), four downstream tests each re-probe SSH on the same
broken datapath and time out identically — single-node job runs ~24 min
instead of ~12 min, with the same error logged five times.

First waitForSSHReady timeout now sets a package-level atomic flag;
subsequent waitForSSHReady / trySSHReady / requireSSHHealthy calls skip
immediately. Preserves the original red signal on TestSSHProbe and on
any test that genuinely needed SSH (Skip ≠ Pass). Bool variant
(trySSHReady) consults but does not set the flag — its caller already
treats False as advisory warning, not fatal.

TestSGToSGDatapath has its own EventuallyErr SSH wait (not via
waitForSSHReady) and needs an explicit requireSSHHealthy(t) gate at
the top of runSGToSGDatapath. TestNATGateway already calls
waitForSSHReady first so the gate fires naturally.

Refs: mulga-siv-137

* fix(ipsec): use Debian unit name openvswitch-ipsec.service

CI artifact shows `Unit ovs-monitor-ipsec.service could not be found`
on every node. Debian's openvswitch-ipsec package ships the unit as
openvswitch-ipsec.service (the binary inside is ovs-monitor-ipsec, but
systemd's name follows the package). The previous commit guarded on
the wrong unit name, so:

- spinifex-daemon.service Wants=/After= silently no-op'd (missing unit)
- enableOVNIPSec's `systemctl enable --now ovs-monitor-ipsec.service`
  failed, daemon logged a warning and continued without flipping
  ipsec_encapsulation=true
- TestMultinodeIPSec skipped with `node1 reports ""` because OVS DB
  never received the cert pointers

Rename across all 5 spots (daemon, systemd unit, test, CI diag script,
workflow journal capture) to match the Debian package layout.

Note: the package itself still must be present on the CI VM image —
that's tracked in the mulga repo (image-builder provision.sh +
bootstrap-install.sh shim).

Refs: mulga-siv-136

* fix(e2e): authorize default SG tcp/22 + icmp in single-node fixture

admin init leaves the default SG closed (AWS parity); the Go single suite
never ported the Phase-5 SG-ingress block that run-e2e.sh has had since day
one, so every test runner SSH/ping probe hits the OVN port-group ACL drop.

- ec2helpers: add AuthorizeICMPIngress + EnsureDefaultSGOpen helpers.
- single/main_test: open default SG once per process in pkgFixOnce.Do.
- witness: extend ensureDefaultSGSSHIngress to authorize ICMP too.
- run-e2e.sh: append matching ICMP authorize next to tcp/22 block.

mulga-siv-134

* fix(network/reconcile): key DHCP_Options lookup by subnet_id not CIDR

Multi-tenant default VPCs share the same subnet CIDR (172.31.0.0/20) per
account. The existing FindDHCPOptionsByCIDR gate at apply.go:107 found
the first account's DHCP_Options row and skipped creation for every
subsequent subnet with the same CIDR. Those subnets' ports then attached
nothing (FindDHCPOptionsByExternalID misses on subnet_id), VMs got no
DHCPv4 lease, and SSH/ICMP into them silently failed even though SG
ACLs and NAT were correct.

Switch the gate to FindDHCPOptionsByExternalID keyed on spinifex:subnet_id
so each subnet owns its own row, matching the attach lookup at line 203.

Verified: account 000000000001 default VPC RunInstances now produces an
LSP with dhcpv4_options populated, VM cloud-init reports a 172.31.0.5/20
lease + default route via 172.31.0.1, and ping + ssh TCP handshake to
the EIP succeed end-to-end. Stale DHCP_Options row for the prior dead
subnet was wiped manually; reconciler recreated the correct row for the
live subnet on its next pass.

* fix(ipsec): enable openvswitch-ipsec at provision time, drop daemon write

Provisioning now runs `systemctl enable --now openvswitch-ipsec.service`
alongside openvswitch-switch and ovn-controller. The spinifex-daemon
process drops its `enable --now` shell-out and only polls is-active.

Sudoers gains one read-only line:
  spinifex-daemon ALL=(root) NOPASSWD: /usr/bin/systemctl is-active openvswitch-ipsec.service

This mirrors the existing vpcd ovn-controller is-active precedent and
removes the daemon's need for systemd-write capability. Aligns with
least-privilege service account pattern: provision enables services,
daemon only reads status.

If the unit is inactive at runtime, the daemon refuses to flip
ipsec_encapsulation=true (silent-drop guard from mulga-siv-136) and
surfaces a clear error pointing at scripts/setup-ovn.sh.

* chore: unblock preflight on feat/network-layer-redesign

Two pre-existing failures blocked preflight on the branch:

- govulncheck flagged golang.org/x/net@v0.54.0 (GO-2026-5026, ASCII Punycode
  rejection bug in idna.ToASCII); reached via utils.DownloadFileWithProgress.
  Bump to v0.55.0; go mod tidy carries x/sys to v0.45.0.
- TestTopologyHandler_SubnetCreate_RouterPortFails asserted subnet create
  fails when the parent VPC router is missing. That contract changed in
  aed7b2e (mulga-siv-133), which made handleSubnetCreate call EnsureVPC
  idempotently before EnsureSubnet to avoid a NATS publish-order race.
  Delete the now-impossible failure case.

* refactor(network/ovn): relocate nbdb model package from services/vpcd

Phase 4 / mulga-siv-125.6 Slice A. Pure import rename, no logic change.

The OVN Northbound DB model (LogicalSwitch, LogicalRouter, DHCPOptions,
etc.) lived under services/vpcd/nbdb/ because that was the original home
of every OVN caller. After Phase 1+2 the L1 client (network/ovn) and all
L3/L5 managers (network/policy, network/external, network/topology,
network/reconcile) became the primary callers — 8 importers in network/*
vs 2 in services/vpcd/. The directory move puts the schema model where
its consumers are, and unblocks deleting services/vpcd/ entirely once
the subscriber/launcher relocations land (Slices B–D).

* refactor(vpcd): delete dead retrofit/reconcileIGW helpers + bridge-mode bleed

Phase 4 / mulga-siv-125.6 Slice B.

Production path no longer touches any of:

- RetrofitAllGatewayPortNetworks / RetrofitAllExternalLocalnetOptions —
  the 5-pass startup leftovers that network/reconcile (Phase 2.2) made
  redundant. Nothing called them outside tests.
- reconcileIGW + its allocateGatewayLRPIP / gwLrpRange helpers + the
  ipv4ToUint32 / uint32ToIPv4 utilities — superseded by
  external.IGWManager (Phase 2.4) which carries its own pool logic.
- ensureLocalnetOptions / ensureGatewayPortNetworks /
  expectedGatewayPortNetwork — read-before-write retrofit shims for the
  same code paths.
- generateMAC — only callers were reconcileIGW + its tests.

useCentralizedNAT (the bridge-mode bleed flagged in plan §2.2) is
replaced by a policy.NATMode value injected via WithNATMode(...). The
mode is resolved once in vpcd.go from host.UplinkMode and threaded into
both the topology-handler lazy managers and the reconciler stack, so
"is this veth?" is no longer a question topology.go can ask. The
TopologyHandler defaults to NATModeDistributed when WithNATMode is
omitted, matching the previous default.

Drops services/vpcd/topology.go from 1220 LOC to 693, deletes ~700 LOC
of obsolete tests (TestGenerateMAC, TestEnsureLocalnetOptions_*,
TestRetrofitAllExternalLocalnetOptions_FixesClearedOptions,
TestReconcileIGW_*, TestGwLrpRange), and frees the nbdb + utils +
net imports in topology.go.

Stale "phase 4 migrates those onto the new managers" comment in vpcd.go
fixed in passing — the subscribers were migrated in Phase 2.6
(mulga-siv-129); only the file-relocation parts of Phase 4 remain.
Stale ensureLocalnetOptions / ensureGatewayPortNetworks references in
network/ovn/{live.go,mock/mock.go} doc comments also cleaned up.

* refactor(network): move NATS VPC subscribers to network/subscribers

Phase 4 Slice C (mulga-siv-125.6). Promotes the NATS event handlers out of
services/vpcd into a new spinifex/network/subscribers package. Subscriber
holds the topology/policy/external managers directly — the lazy *Once
adapter shim (topology_manager.go) is deleted along with vpcd's local
event-struct copies.

launchService now constructs topology.LiveManager eagerly with a DNS
callback derived from external pools (preserving the unscoped-pool lookup
old TopologyHandler.lmDNSServer did), builds every manager up front, then
hands them to subscribers.New + Subscribe. reconcile.New receives
topology.Manager directly instead of through the adapter.

Bridge-mode constants and waitForFlowsHV move into vpcd.go alongside the
launcher; they were left behind as topology.go's last responsibilities.

Handler-layer tests (topology_test.go, security_test.go, integration_test.go)
are dropped: substance is covered by network/topology, network/policy,
network/external manager tests. subscribers/subscribers_test.go adds
focused coverage: missing-dep rejection, topic registration smoke, and
bad-JSON envelope per topic.

services/vpcd is now down to the launcher + the ovn/mock compat aliases
(removed in Slice D when the launcher promotes to cmd/vpcd/).

* refactor(vpcd): relocate services/vpcd → spinifex/vpcd; drop dead aliases

Phase 4 Slice D (mulga-siv-125.6). Final cleanup of the network-redesign
package layout. services/vpcd/ disappears entirely; the launcher remains
an in-process Service impl, just rehomed under spinifex/vpcd/ (no separate
binary — spx vpcd start stays the cobra entrypoint).

- Delete services/vpcd/mock_ovn.go + ovn.go (compat aliases now dead post
  Slice C; only callsite was launchService's NewLiveOVNClient, inlined to
  ovn.NewLiveClient).
- git-rename services/vpcd/vpcd.go + vpcd_test.go to spinifex/vpcd/.
- Retarget three importers (spinifex/service/service.go +
  service_test.go, cmd/spinifex/cmd/service.go) to the new path.
- Fix stale services/vpcd / TopologyHandler comments in network/reconcile/
  + network/external/types.go + spinifex/vpcd/vpcd.go.
- service-interfaces.yaml vpcd path updated.
- Plan doc §13/§14/§16 + §9.2/§19 updated: drop cmd/vpcd/main.go (was
  speculative; never built) in favour of in-process Service impl at
  spinifex/vpcd/vpcd.go. Plan §16 Created list now lists subscribers/.

Phase 4 plan items 1+2 (remove services/vpcd, entrypoint location)
satisfied. Items 3+4 remain blocked on mulga-siv-125.4 + 125.5 (bundled
join token, plan archive).

* fix(ovn): install openvswitch-ipsec + strongswan explicitly

ovs-monitor-ipsec.service fails to start without an IKE daemon. The
openvswitch-ipsec package only Recommends strongswan, so any apt
config that drops Recommends (or a base image with the recommends
already skipped) leaves the service in a Restart loop with 'IKE
daemon is not installed'. Hoist both packages into setup-ovn.sh so
provisioning is the single source of truth — the bootstrap shim in
mulga is no longer needed.

* test(network): pin ADR-0006 invariants to executable suite

Add static-analysis + behavioural tests that bind every safety and
liveness clause in ADR-0006 (S1-S9, L1-L3) to a named Go test. Failure
output quotes the ADR clause verbatim and points at the offending
file:line so future debugging sessions can't quietly bypass a layer
contract to make a test green.

Static-analysis suite (spinifex/network/invariants/):
- S1 layers_test.go: parses `go list -json`; rejects upward layer
  imports and layers pulling from cross-cutter packages
- S2 host_containment_test.go: AST-detects ovs-vsctl / ovn-nbctl /
  ovs-ofctl shell-out outside network/host/
- S3 nat_mode_test.go: rejects .UplinkMode() / NATModeFromUplinkMode()
  calls outside the init-time resolver locations
- S4 names_test.go: AST-detects OVN object name construction (concat,
  fmt.Sprintf, strings.Join) outside topology/names.go
- S5 policy_no_create_test.go: rejects CreateLogical{Switch,Router,...}
  and DeleteLogical{...} calls inside network/policy/
- S6 federation_isolation_test.go: rejects TransitSwitch /
  TransitRouterPort references and ovn-ic literals outside
  network/federation/ (pre-protects the layer before it lands)
- S8 ipsec_test.go: rejects strongswan / xfrm / IKEv2 / libreswan /
  openswan imports anywhere in network/
- S9 reconciler_singleton_test.go: rejects Reconcile…Loop and
  Reconcile…Pass<n> function names anywhere in network/
- S7 nats_subjects_test.go: scans for `vpc.<verb>` subjects missing
  the {azID} segment; calls t.Skip with the gap report so every test
  run prints the work-to-do without breaking CI. Flip to t.Fatalf
  when the cluster-wide subject rename ships.

Behavioural suite (spinifex/network/reconcile/liveness_test.go):
- L1 reconciler converges: scaled-intent (N=1,3,8) double-Reconcile
  property test; asserts second pass is a no-op
- L2 drift bound: structural check that DriftInterval is positive and
  ≤30 min support window; full fake-clock behavioural test deferred
- L3 federation re-enables: t.Skip stub pointing at the missing
  network/federation/ package

Fixes the one production S4 violation the new walker found:
network/external/igw.go was constructing "gw-port-"+vpcID inline.
Adds topology.GatewaySwitchPort(vpcID) helper and retargets both
AttachIGW and DetachIGW callsites through L2.

Plan + per-clause mechanic + phasing in
docs/development/improvements/network-invariants.md.

Refs: mulga-siv-140

* fix(ovn): install strongswan-charon (not strongswan metapackage)

The strongswan metapackage's '\''charon-systemd | strongswan-charon'\''
alternative resolves to charon-systemd by default, which ships
/usr/sbin/charon-systemd but not the legacy /usr/sbin/ipsec helper or
/usr/lib/ipsec/charon binary that ovs-monitor-ipsec --ike-daemon=strongswan
shells out to. Install strongswan-charon explicitly to pull
strongswan-starter (legacy ipsec controller) + the matching charon binary,
matching what openvswitch-ipsec.service expects.

Also reset-failed + restart openvswitch-ipsec.service after enable to
recover from the deb post-install starting the service before its
dependencies finished unpacking.

* chore: add CODEOWNERS — joshsiv-mulga gates network/ + vpcd/

Fall-through reviewer for any change is the maintainer.
network/ and vpcd/ are explicitly listed so the matching branch
protection rule ("Require review from Code Owners") routes those
PRs to joshsiv-mulga. Those trees are governed by ADR-0006
invariant tests (spinifex/network/invariants/); CODEOWNERS adds a
human review gate on top of the mechanical fence.

Refs: mulga-siv-141

* chore: CODEOWNERS fallthrough → @mulgadc/mulgadc-engineers team

Fallthrough reviewer should be the team, not a single maintainer, so
any engineer can approve PRs outside the explicitly-gated paths.
network/ and vpcd/ keep joshsiv-mulga as the required reviewer per
ADR-0006 invariant ownership.

Refs: mulga-siv-141

* feat(ci): add test_run workflow input for -test.run filter

Pass an optional regex through to each suite's '\''go test -test.run'\'' so
dispatches can target a single test (e.g. '\''^TestMultinodeIPSec$'\'') without
running the full multinode suite. Threaded through single, multinode, and
reboot suite invocations; empty input preserves current behaviour.

* fix(daemon): flip NB_Global.ipsec=true on management node

Setting Open_vSwitch.other_config:ipsec_encapsulation=true on each
chassis is necessary but not sufficient for OVN native IPsec — without
NB_Global.ipsec=true, ovn-controller never adds options:remote_name to
the Geneve tunnel ports, so ovs-monitor-ipsec sees no IPsec-enabled
tunnels and the kernel xfrm tables stay empty. After enabling
ipsec_encapsulation locally, also write NB_Global.ipsec=true when the
local ovnnb_db socket is present (management node only); workers skip
silently — one writer is enough for a cluster-wide flag.

Adds a scoped sudoers entry pinning the daemon to that exact ovn-nbctl
invocation so the grant can't be reused for other NB mutations.

* fix(ovn): grant charon AppArmor read on /etc/spinifex/ipsec

The strongswan-charon profile only allows reads from /etc/ipsec.*,
/etc/strongswan.*, and a small fixed allowlist. ovs-monitor-ipsec writes
the per-tunnel strongSwan config with absolute paths to our peer cert +
key under /etc/spinifex/ipsec/, so charon hits 'Permission denied'
loading them (it runs as uid 0 but AppArmor still blocks) and no xfrm
SAs come up. Drop a read grant for /etc/spinifex/ipsec/** into the
profile's local override hook + reload.

* fix(ovn): pin OVS system-id to hostname for IPsec cert identity match

ovs-monitor-ipsec uses chassis-id as the IKEv2 `@<name>` peer identity in
the strongSwan config it generates. Our per-node IPsec peer cert
(admin.GenerateIPSecPeerCert) carries the node name as CN + dnsName SAN.
With chassis-id left at the package-generated UUID, charon validates
`@<UUID>` against a cert with dnsName=<hostname> — mismatch returns
AUTHENTICATION_FAILED and no xfrm SAs are negotiated.

Pin system-id to hostname (which equals the node name on Mulga clusters)
by writing both the on-disk source of truth (/etc/openvswitch/system-id.conf,
read by ovs-ctl on boot) and the running OVS DB value. Writing only one
would drift on the next reboot — the original "do not override" comment
was right about that hazard, just wrong about the resolution.

Cross-link the invariant in admin/ipsec.go: changing the cert identity
without updating setup-ovn.sh (or vice versa) breaks IKE silently.

Refs: mulga-siv-136

* fix(ovn): take --node-name flag so chassis-id matches cluster identity

CI hostnames are bead-themed (env20-casuarina) and don't match the
cluster node name (node1/node2) baked into the IPsec peer cert dnsName
SAN at `spx admin init/join --node NAME`. Pinning system-id to
`hostname -s` produced env20-casuarina; charon then validated
`@node1` against dnsName=env20-casuarina and IKE failed with
AUTHENTICATION_FAILED.

Add a --node-name=NAME flag to setup-ovn.sh, default to hostname for
manual/dev invocations, and update the ansible install role to pass
{{ spinifex_node_name }}. The matching bootstrap-install.sh change
lives in mulga.

Refs: mulga-siv-136

* refactor(daemon): relocate L0 helpers to network/host + widen ADR-0006 S2

Phase 4 Slice E of mulga-siv-125.6. Cleans up spinifex/daemon/network.go
per the audit and widens the S2 invariant to forbid OVS/OVN shell-outs
in spinifex/daemon/ (daemon is an L0 consumer; S2 applies).

Moved to network/host/:
- OVSNetworkPlumber + SetupTap/CleanupTap → host.OVSPlumber (host.NewOVSPlumber)
- GetBridgeIPv4 → host.GetBridgeIPv4
- OVNHealthStatus + CheckOVNHealth → host.OVNHealth + host.HealthStatus
- daemon/ipsec.go OVS/OVN ops → host.SetIPSecCertPaths, host.EnableIPSecEncapsulation, host.SetNBGlobalIPSec

Moved to utils:
- sudoCommand → utils.SudoCommand + utils.SetSudoCommandForTest test seam
  (cross-package reassign would trip the reassign linter; helper keeps
  the indirection inside utils).

Moved to vm:
- generateMgmtMAC → vm.GenerateMgmtMAC (pairs with vm.GenerateDevMAC)

Deleted (dead):
- SetupComputeNode (replaced by network/host/bridges.go:ensureBridges +
  scripts/setup-ovn.sh:572-579)
- EnsureDataRoute
- findInterfaceByIP
- daemon/network.go + dead tests in daemon/network_test.go (duplicates of
  vm package tests retained; mgmt MAC test moved to vm/lifecycle_test.go)

S2 invariant (network/invariants/host_containment_test.go) now walks
both spinifex/network/ and spinifex/daemon/, skipping network/host/.

* fix(ovn): broaden AppArmor read grant to /etc/spinifex (covers CA cert)

The earlier override granted reads on /etc/spinifex/ipsec/** only, which
covers the peer cert + key but NOT the cluster CA at /etc/spinifex/ca.pem.
charon then can't load the CA, can't validate the peer cert chain, and
surfaces the failure as `no trusted RSA public key found for '<peer>'`
even though identity matching now succeeds — IKE_AUTH fails with
AUTHENTICATION_FAILED and no xfrm SAs negotiate.

Grant /etc/spinifex/** instead (covers ca.pem + ipsec/peer.{pem,key})
and always rewrite the override so re-runs replace the older narrower
rule.

Refs: mulga-siv-136

* fix(ipsec): symlink cluster CA into charon's default cacerts dir

ovs-monitor-ipsec writes per-conn `cacert=/etc/spinifex/ca.pem` references
in the strongSwan config, but strongSwan 6.0 only loads CAs declared in
standalone `ca` sections or files placed in /etc/ipsec.d/cacerts at
startup. Without this, charon authenticates the local side fine but
rejects every inbound peer cert as `no trusted RSA public key found for
'<peer>'`, AUTH_FAILED, and no xfrm SAs negotiate.

Do the symlink in admin.GenerateIPSecPeerCert (right after writing the
peer cert) — setup-ovn.sh runs before `spx admin init/join` creates
/etc/spinifex/ca.pem, so the wiring can't live there. Use a stage-and-
rename pattern so concurrent test invocations don't race on the symlink.

/etc/ipsec.d/cacerts is on charon's default AppArmor allowlist so no
profile change needed.

Refs: mulga-siv-136

* chore(setup-ovn): drop apt-get install_packages block

OVS/OVN/openvswitch-ipsec/strongswan-charon are baked into the CI gold
image via mulga's image-builder/scripts/provision.sh (commits 116bb05,
a9b3a9c). Keeping a runtime apt-get install path here pulled CI through
apt-cacher-ng on every bootstrap and tripped on intermittent "Message
has been manipulated" InRelease cache corruption (env21/env20 runs).

Drop the install block. Gold-image rebuild is the canonical place to
add new system packages. If a package is missing, downstream ovs/ovn
commands fail loudly during setup-ovn.sh's later steps — clearer signal
than silently re-installing through a flaky proxy.

setup.sh already supports INSTALL_SPINIFEX_SKIP_APT=1 (passed by mulga's
bootstrap-install.sh:237) so this removes the last runtime apt-get call
on the CI provisioning path.

* fix(ovn): gate system-id pin on explicit --node-name

setup-ovn.sh used to fall back to `hostname -s` when --node-name wasn't
passed, and then unconditionally wrote that value to
/etc/openvswitch/system-id.conf + ovs-vsctl external_ids:system-id.

On CI single-node, the gold image already registered a chassis with
name=<UUID>; setup-ovn.sh then rewrote system-id to the bead-themed
hostname (env10-banksia). vpcd's discoverChassis treats any chassis row
whose name != local system-id but hostname == local hostname as a stale
local chassis and skips it, so vpcd reported "no OVN chassis registered
in SBDB" and refused to start, cascading into the e2e + e2e-go failures
on run 26430839508.

Drop the hostname fallback. If --node-name is given, pin both the
on-disk file and the running OVS DB to it (callers that care about
IPsec cert identity matching still get it). If no --node-name is given,
leave the existing system-id alone — that's always safe whether the
value came from a gold-image UUID, bootstrap-install.sh writing nodeN
before this script runs, or a manual ansible value.

* fix(network/reconcile): skip orphan prune on startup; drift owns GC

The vpcd startup reconcile races against the daemon's EnsureDefaultVPC:
the daemon writes SG KV rows + publishes vpc.create-sg on each node in
parallel with vpcd starting up. The leader-gated reconcile can load
intent before any SG row is visible on its local JetStream replica
while subscribers on peer nodes are concurrently creating port groups
from the same vpc.create-sg events. A startup orphan-port-group sweep
then deletes managed sg_* port groups that intent hasn't caught up to.

CI run 26434124790 trace:
  node2 reconcile/lock: elected holder=env20-bottlebrush
  node2 reconcile: starting intent_sgs=0
  node2 reconcile/apply: removed orphan port group pg=sg_161c70ce23e704a2a
  node2 reconcile/apply: removed orphan port group pg=sg_a0d078650a3150391
  node2 reconcile/apply: removed orphan port group pg=sg_54b564b374e9162bb

Every subsequent RunInstances → vpc.create-port failed with
"port group not found" for ~3 minutes until the 5-minute drift tick
recreated the port groups. Tests give up after 60s; six multinode
suites cascade-fail on InsufficientInstanceCapacity.

Split the reconciler into Reconcile (full prune, drift loop) and
ReconcileApplyOnly (no prune, startup). applySGs takes a pruneOrphans
bool. vpcd startup calls ReconcileApplyOnly; drift loop unchanged.
Legitimate orphans get garbage-collected on the next drift tick — at
worst 5 minutes of lingering rows, no production impact.

Add TestReconcile_ApplyOnlyKeepsOrphanPortGroup to lock the contract.

* fix(ipsec): trigger charon rereadcacerts after CA symlink install

strongSwan scans /etc/ipsec.d/cacerts only at charon startup. The unit
openvswitch-ipsec.service is enabled at provision time and starts before
admin init writes the cluster CA symlink, so charon ends up running with
zero CAs loaded. Every IKE_AUTH then fails with `no trusted RSA public
key found for '<peer>'` and no SAs negotiate — the failure mode exposed
by TestMultinodeIPSec.

Append a stroke rereadcacerts call at the end of
installCAIntoCharonTrustStore so an already-running charon picks up the
freshly-placed CA without a service restart. Failure is swallowed at
debug — a missing/stopped charon at admin-init time is expected and a
later startup will scan cacerts naturally.

* refactor(network/host): move IPSec orchestrator from daemon (ADR-0006 S8)

ADR-0006 S8: "IPSec is OVN-native only. No layer implements custom IKEv2,
XFRM rules, or direct strongSwan management. IPSec SA lifecycle is delegated
entirely to OVN native IPSec and is invisible above L0."

The enableOVNIPSec orchestrator and its ensureOVSMonitorIPSecActive helper
lived in daemon/ipsec.go but composed L0 primitives (SetIPSecCertPaths,
EnableIPSecEncapsulation, SetNBGlobalIPSec) that already lived in
network/host. The orchestrator now lives alongside its callees as
host.EnableOVNIPSec, taking configPath and clusterConfig from the daemon at
the call site. Helper and test-override package vars (systemctlActiveTimeout,
ovnNBSocketPath) move with it; tests are translated to call EnableOVNIPSec
directly rather than via the Daemon struct.

Closes mulga-siv-142

* refactor(daemon): use topology.Port for OVN port names (ADR-0006 S4)

ADR-0006 S4 forbids any layer above L2 from constructing OVN object
names. Three daemon sites formatted "port-" + ENIId inline; route them
through topology.Port instead.

Closes mulga-siv-143

* refactor: use topology.Port for OVN port names in handlers + vm (ADR-0006 S4)

Replace inline "port-"+eniID formatting across five sites (eip, instance x2,
vpc/eni, vm/network_helpers) with topology.Port. OVSIfaceID stays as a thin
wrapper to preserve the OVN binding contract comment and existing call sites.

Closes mulga-siv-144

* test(network/invariants): widen scan roots to daemon/handlers/vm/testutil/utils (ADR-0006)

Widen ADR-0006 invariant scan roots so drift in upstack consumers surfaces
in CI. Backlog of violations in widened roots was drained by
mulga-siv-142/-143/-144; this commit makes the wider scan permanent.

  - S2 (host_containment): add vm/ alongside network/ + daemon/
  - S3 (nat_mode):         add daemon/ alongside network/ + vpcd/
  - S4 (names):            add daemon/, handlers/, vm/ alongside
                           network/ + vpcd/; add narrow AWS-ID exemption
                           (vpc-cidr-assoc-) so AWS resource IDs are not
                           misclassified as OVN object names
  - S6 (federation):       add daemon/, handlers/ alongside network/;
                           convert single-root walk to slice
  - S7 (nats_subjects):    add daemon/, handlers/, testutil/, utils/ —
                           stays t.Skip pending cluster-wide subject
                           rename; gap report now lists 58 subjects

CODEOWNERS: add /spinifex/network/invariants/ rule so widening or
narrowing the scan needs explicit owner review.

Closes mulga-siv-145
Refs: audit-adr-0006.md

* chore(e2e): disable IPsec in pseudo multi-node test

Pseudo multi-node runs three simulated nodes as unprivileged tf-user.
The charon trust-store install in 904b45e writes /etc/ipsec.d/cacerts,
which fails with EACCES under a non-root caller and aborts admin init.

Disable --ipsec for this suite — loopback-only nodes don't exercise
real Geneve encryption anyway. Real-multi-node + single-node e2e
(both run admin init via sudo) continue to cover the IPsec path.

* fix(ovn): atomic Ensure* primitives prevent duplicate logical entities

OVN NB has no unique constraint on Name. The previous
GetLogicalRouter→CreateLogicalRouter sequence in EnsureVPC was a TOCTOU
race: when vpc.create on one node and the defensive vpc.create-subnet
EnsureVPC call on another both observed absence, both inserted, yielding
two routers per VPC. The orphan held DNAT references blocking EIP
detach, and DNAT/flow installation landing on the orphan caused
TestMultinodeGuestSSH SSH timeouts.

Add EnsureLogicalRouter / EnsureLogicalSwitch / EnsurePortGroup to the
libovsdb client. Each builds a single OVSDB transaction combining a
wait-op (Until=equal, Rows=[]) gated on absence of a Name match with the
insert. The server serialises the wait+insert atomically; concurrent
callers see exactly one survivor and the rest fall through to a re-fetch
that returns the canonical row.

Switch all production callers (topology.EnsureVPC / EnsureSubnet /
EnsureSGPortGroup, external.AttachIGW, reconcile.applyVPCs /
applySubnets) to the Ensure* variants. Bare Create* remains available to
the L1 wrapper.

Add invariant test TestS4_OVNNamedCreatesUseEnsure (AST walk) to block
future reintroduction of the bare Create* call sites outside
network/ovn.

Mock implements Ensure* under its existing mutex so the concurrency
tests (50/30/30 goroutines for Router/Switch/PortGroup) prove a single
UUID survives.

Refs: mulga-siv-146

* fix(ovn): wait-op rows must be non-empty; flip to NotEqual predicate

The Ensure* primitives sent a wait-op with `Rows: []ovsdb.Row{}` plus
`Until: ==` (RFC 7047 §5.2.6 absence test). The libovsdb Operation
struct tags Rows as `json:"rows,omitempty"`, so the empty slice was
dropped on the wire and ovsdb-server rejected every transaction with
"Required 'rows' member is missing", breaking reconciler bootstrap and
every downstream create-port lookup ("logical switch X not found").

Flip the predicate to the equivalent `Until: !=` formulation with a
single-row projection containing the Name we want absent:

  no row    → projection []           != [{name}] → predicate holds
  row exists → projection [{name}]    == [{name}] → predicate fails

Same atomic guarantee, JSON now well-formed. Mock tests can't catch
this — only a real ovsdb-server validates the envelope.

* chore: remove generateMAC wrapper

* chore: remove all bead / plan references

* fix(network/policy): wait for chassis flows after AddNATGateway

AddEIP fires m.barrier() to block until ovn-northd compiles NB→SB and every
chassis installs the new dnat_and_snat flows; AddNATGateway returned right
after the NB commit. So `aws ec2 create-route … --nat-gateway-id` would
publish vpc.add-nat-gateway, the SNAT row would land in NB, and the API
call would succeed before the gateway chassis had programmed the SNAT flow
for the private subnet.

Phase 8d's 10×5s=50s ping budget races that flow-install latency on slow
CI hosts (last seen run 26455602615 single-node, identical flake on
unmodified dev run 26434711010 — pre-existing, not introduced by Ensure*).

Mirror AddEIP: call m.barrier() after AddNAT returns. Add unit test
TestNATManager_AddNATGateway_FlowsBarrier_Fires covering the new path.

* chore: remove more plan refs

* chore: remove GenerateIPSecPeerCertIfEnabled

* chore: remove dupliate subnetGatewayCIDR function

* chore(network): trim superfluous comments across network/ tree

Collapse multi-paragraph godocs to 1-2 sentences, drop WHAT-restatement
comments, remove section dividers grouping <10 items, and cut prose
narration in tests. ADR clause references, one-line WHY comments for
non-obvious OVN/OVSDB/AWS/NATS semantics, and exported-symbol godoc are
preserved. No behavioural changes.

Packages: invariants, topology, host, external, ovn, reconcile, policy,
subscribers.

* fix(igw): restore attachment State="available" for AWS parity

AWS InternetGatewayAttachment.State is "available" when an IGW is
attached to a VPC, per the AWS SDK doc ("the state is available when
attached to a VPC; otherwise, this value is not returned"). Commit
b7505f8 wrote "attached"/"detached" to align with the reconciler
filter, which inverted AWS parity.

Fix the producer to write "available" again and update the consumer:
 - handlers/ec2/igw: AttachInternetGateway and DetachInternetGateway
   both persist State="available"; IGWRecord comment narrowed.
 - network/reconcile/intent.loadIGWs: filter accepts "available" (was
   "attached"); attachment is identified by VpcId != "".
 - tests updated: igw service_impl_test, routetable service_impl_test
   fixture, reconcile intent_test fixture.

* Update spinifex.toml

* refactor(subscribers): route EIP/NATGW through L5 wrappers (ADR-0006 §S1)

Subscriber previously called policy.NATManager directly for EIP and NAT
Gateway operations, bypassing the L5 wrappers (EIPManager, NATGWManager)
that existed on paper. ADR-0006 §S1 requires every cross-layer call to
pass through the immediate lower neighbor's typed interface; IGW already
followed this pattern.

Wire EIPManager and NATGWManager into the Subscriber struct, construct
them in vpcd alongside IGWManager, and swap the four direct-L3 call
sites (AddEIP, DeleteEIP, AddNATGateway, DeleteNATGateway) onto the
L5 surface (AttachEIP, DetachEIP, AttachNATGateway, DetachNATGateway).
AttachEIP now fires the flows-barrier, giving callers the same
"reachable on return" guarantee IGW already had.

The reconciler still calls policy.NATManager directly; that's a
cross-cutter and a separate concern.

* test(reboot): port 8MB WAL pad workaround from bash run-reboot-e2e.sh

App VMs' user-data writes (unit file + index.html) sit in the on-host
WAL until WriteWALToChunk crosses the 4MB threshold. Host reboot before
that loses them — systemd then refuses to load the zero-byte unit and
the responder never starts. Mirror the bash driver's dd+sync pad so the
WAL flushes pre-reboot. Drop when the upstream WAL fix lands.

* test(e2e): dump OVN/OVS/SG state on Phase 8d NATGW failure

Phase 8d's existing failure path only prints lr-nat-list and
lr-route-list. CI artifacts are not uploaded when run-e2e.sh exits
nonzero, so debugging the NATGW regression requires inline diagnostics
in the journal. Expand the dump to include nb/sb show, chassis bindings,
port_group ACLs, br-int flows filtered to the NATGW IP/private subnet,
host routes, and the private VM's own ip/route/neigh state.

* fix(ovn,reconcile): scope NAT deletes to router; NATGW snat per associated subnet

Two compounding bugs caused Phase 8d NATGW E2E flake (~60% CI failure):

1. ovn.DeleteNAT/DeleteNATByExternalIP searched all NAT rows globally and
   only mutated the named router afterwards. With AWS subnet CIDRs repeating
   across VPCs, (type, logicalIP/externalIP) is not globally unique — the
   delete picked a NAT row owned by a different router, the mutate was a
   no-op, and the row delete failed with "remaining reference(s)", leaving
   the original router's NAT orphaned. Both calls now resolve the LR first
   and filter NAT lookups to lr.NAT UUIDs. Mock client mirrors the scoping.

2. reconcile.loadNATGWs used the NATGW's home (public) subnet CIDR as
   SubnetCIDR, producing an snat for the wrong CIDR that collided with the
   correct event-published snat. loadNATGWs now walks route tables and
   emits one NATGWSpec per (NATGW, associated private subnet) pair,
   mirroring publishNatGatewayEventsForAssociation. Intent map keyed by
   natgwID|subnetCIDR so multi-subnet NATGWs produce distinct specs.

Tests:
- nat_test.go: cross-router same-logicalIP isolation for DeleteEIP and
  DeleteNATGateway
- intent_test.go: NATGW snat uses associated private subnet CIDR, not the
  NATGW home subnet; NATGW with no associations produces no spec

---------

Co-authored-by: Julian Sommer <115516918+juliansommer@users.noreply.github.com>
2026-05-27 21:05:01 +10:00
Julian Sommer 20a8a39608 feat: flip images to UEFI default (#237) 2026-05-20 12:34:51 +10:00
Josh Siviour 4ae2a4ac53 feat(elbv2): QEMU microvm direct-boot for LB system instances (#228)
* feat(vm): direct-boot foundations + config/input extensions + image build pipeline

vm package (mulga-siv-62):
- Add KernelImage, Initrd, KernelCmdline, FwCfg/FwCfgEntry to vm.Config
- Emit -kernel/-initrd/-append/-fw_cfg args when fields set
- Relax drive invariant: accept kernel image in place of drives
- Add devices.go: IsMMIO predicate, NetDevice/BlkDevice/RngDevice helpers
- Refactor lifecycle.go + network_helpers.go call sites to use helpers
- shutdown.go: os.Remove fw_cfg tmpfiles after QEMU exits
- Add devices_test.go, microvm_test.go; extend vm_test.go

config/input extensions (mulga-siv-63):
- Add MicrovmConfig{ELBv2Enabled, ImagePath} to DaemonConfig
- ImagePath falls back to /usr/share/spinifex/microvm when empty
- Add commented [microvm] section to spinifex.toml template
- Add DirectBoot bool + NICs []NICConfig to SystemInstanceInput

image build pipeline (mulga-siv-64):
- scripts/build-microvm-image.sh: Alpine chroot build producing vmlinuz + initramfs.cpio.gz
- build/microvm/init.sh: fw_cfg-driven PID 1 init (mounts, modprobe, NIC config, lb-agent-env, ca-cert)
- build/microvm/inittab: BusyBox init with lb-agent respawn
- make build-microvm-image target
- setup.sh: install microvm/* to /usr/share/spinifex/microvm/
- .gitignore: exclude built vmlinuz + initramfs.cpio.gz artifacts

* feat(daemon): direct-boot launch path for microvm system instances

When SystemInstanceInput.DirectBoot=true:
- Skip GetAMIConfig and GenerateVolumes
- Build vm.Config directly (no buildBaseVMConfig, no PCIe root ports)
- MachineType=microvm,x-option-roms=off,pic=off,pit=off,rtc=on,acpi=on,isa-serial=on
- Resolve kernel/initrd from Microvm.ImagePath config field
- Serialise NICs to three fw_cfg tmpfiles (netcfg, lb-agent-env, ca-cert)
- Validate exactly one NICConfig.IsDefault=true before writing netcfg blob
- Shutdown path cleans up tmpfiles via existing Config.FwCfg iteration

PC-machine path (DirectBoot=false) unchanged.

Closes mulga-siv-65

* feat(elbv2): wire microvm.elbv2_enabled flag into ELBv2 service

When ELBv2Enabled=true:
- Drop lbVMUserData cloud-config; emit KEY=value LBAgentEnv blob instead
- Set SystemInstanceInput.DirectBoot=true; omit ImageID
- Populate NICs []NICConfig (index 0=primary ENI IsDefault, 1=mgmt, 2+=extra ENIs)
- Validate exactly one IsDefault NIC at service layer

When ELBv2Enabled=false: existing PC-machine path unchanged.

Adds buildLBAgentEnv, buildMicrovmNICs, subnetCIDRForIP, subnetGatewayIP helpers.
Tests in arn_test.go cover both flag-on and flag-off paths.

Closes mulga-siv-66

* test(daemon,vm): add unit tests for direct-boot helpers to meet diff coverage threshold

* feat(daemon): Phase 1 perf instrumentation + e2e runner microvm flag

- Log t1→t2 boot timing via slog on the direct-boot path
- measureQEMURSSMiB helper reads /proc/<pid>/status (tested)
- Gate constants: phase1BootGateMs=500, phase1RSSGateMiB=25
- run-lb-e2e.sh: --microvm flag, dual-path CI annotation, density test note

Closes mulga-siv-67

* fix(build): remove busybox-initscripts — not in Alpine 3.20, not needed

* fix(microvm): end-to-end fixes for direct-boot LB path

Serial output was silent (x-option-roms=off suppresses BIOS serial init);
fixed by removing it from the machine string and using -serial chardev:console0
to attach to the machine-created ISA serial device instead of adding a
duplicate isa-serial device (which would create ttyS1 while kernel uses ttyS0).

virtio-net interfaces were invisible to the kernel because QEMU's
auto-kernel-cmdline does not append virtio_mmio.device= params when -append
is used. Fixed by generating explicit virtio_mmio.device=0x200@0xfebNNNNN:N
params for each NIC in KernelCmdline, and modprobing virtio_mmio + virtio_net
in init.sh.

sys.micro bumped to 512 MiB — 128 MiB caused kernel OOM during initramfs
decompression (~68 MiB uncompressed).

BusyBox init ::respawn: entries do not source or export env files; fixed
inittab to use set -a; . /etc/conf.d/lb-agent; set +a before exec.

wireLBAgentConfig was documented as reading the CA cert but never set
elbv2Service.CACert; lb-agent TLS handshakes to AWSGW failed with
x509: certificate signed by unknown authority. Fixed by reading
d.config.NATS.CACert (same local CA that signs the AWSGW server cert)
and assigning to elbv2Service.CACert so writeFwCfgBlobs writes a
non-empty cacert blob into fw_cfg.

Adds vm_test TestExecute_MicrovmFileChardev and updates lifecycle_test
to assert SerialSocket is intentionally empty on direct-boot VMs.

* fix(build): auto-detect docker/podman when apk unavailable for microvm image build

* fix(build): create /dev/console and /dev/null as proper device nodes in initramfs

tar extraction without root silently demotes device files to 0-byte regular
files (mknod requires CAP_MKNOD). The kernel opens /dev/console when wiring
init's stdio to the serial console; a regular file there causes all init output
to be silently discarded to RAM — the VM appears stuck at 'Run /init as init
process' with no subsequent console output and lb-agent never heartbeats.

Fix: after rootfs population, wipe /dev and recreate console (c 5 1) and
null (c 1 3) via sudo mknod. devtmpfs provides all other devices at runtime
once init.sh mounts it.

* fix(microvm): fix mgmt NIC routing for all LB schemes

Two bugs prevented lb-agent from reaching the AWSGW via the mgmt interface:

1. RouteDst/RouteVia swapped — resolveMgmtRoute returns (gateway, target) but
   buildMicrovmNICs assigned them as (Dst=gateway, Via=target), producing
   'ip route add 10.15.8.1 via 192.168.1.33' instead of the correct
   'ip route add 192.168.1.33 via 10.15.8.1'.

2. NIC[1] MAC and CIDR never filled — the daemon allocates mgmt IP/MAC
   after buildMicrovmNICs returns, but didn't inject them into input.NICs[1]
   before calling writeFwCfgBlobs, leaving NIC1_MAC= empty in the netcfg
   blob and skipping interface setup in init.sh entirely.

Also extends mgmt routing to internet-facing scheme in the microvm path:
VPC SNAT is not reliable across all VPC topologies for control-plane
heartbeats; mgmt is always a direct L2 path to the host.

* feat(microvm): Phase 2 kernel stripping + boot optimisation

- cpu: switch to host,-pmu (disable PMU — not needed in microvm guest)
- machine type: make isa-serial configurable via microvm.isa_serial config
  field; default true (on) preserves console log path
- build: strip unused kernel modules (USB, IDE, ATA, GPU, media, input,
  HID, bluetooth, staging, sound, wireless) from initramfs before cpio
- build: add Phase 2 artifact size gate — fail if vmlinuz + initramfs.cpio.gz
  exceeds MICROVM_ARTIFACT_MAX_MiB (default 50 MiB); override via env var
  during development
- perf: add phase2BootGateMs=300 and phase2ArtifactGateMiB=50 constants
  with canary tests to catch unintentional gate changes
- tests: cover buildMicrovmNICs nil-VPC and extra-ENI paths
- tests: cover microvmMachineType nil/true/false branches

* fix(build): use find-based virtio+fw_cfg module keep-list in initramfs strip

The directory-only keep-list (drivers/virtio, drivers/firmware) missed
virtio_net.ko which lives in drivers/net/, virtio_blk in drivers/block/,
and virtio-rng in drivers/char/hw_random/. Switch to find-based approach:
collect all virtio*.ko* and *fw_cfg*.ko* regardless of subdirectory, then
restore them into their original relative paths under kernel/.

Artifacts now: 42 MiB (vmlinuz 11 MiB + initramfs 31 MiB), gate passes.

* fix(build): keep failover modules in initramfs strip

virtio_net depends on net_failover/failover for live-migration support.
Stripping them left virtio_net with unresolved symbols
(net_failover_create/destroy), so the module failed to load and the
guest came up with only lo. init.sh then skipped every NIC ("no
interface found for MAC ..."), leaving lb-agent with no network path
to AWSGW and the LB stuck in provisioning.

Add *failover*.ko* to the keep-list. Image size unchanged at 42 MiB
(under the 50 MiB Phase 2 gate). ELBv2 e2e now reaches active and
2/2 targets healthy for both ALB and NLB internal LBs.

* fix(daemon): restore slog default after viperblock.New mutates it

viperblock.New unconditionally calls vb.SetDebug, which calls
slog.SetDefault with a TextHandler at LevelError — globally silencing
every slog.Info and slog.Warn in the caller process for the rest of
its life. Discovered while validating microvm Phase 2 (mulga-siv-68):
the daemon stopped emitting Info logs the moment the first customer
VM with volumes launched, hiding direct-boot timing,
LaunchSystemInstance completed, and CreateLoadBalancer completed
lines that we need for boot-time tuning.

Workaround in newViperblock: re-install an Info-level TextHandler on
os.Stderr after each viperblock.New call. Also drop the three explicit
vb.SetDebug(false) calls in prepareRootVolume / prepareEFIVolume /
prepareCloudInitVolume — they were no-ops (viperblock.New already
runs SetDebug internally) and each one re-triggered the global
mutation we are trying to undo.

Proper fix is in viperblock itself — tracked as mulga-siv-70: SetDebug
should not call slog.SetDefault. Until then, this restore call is the
shortest path to getting the daemon's observability back so we can
measure t1_to_t2_ms and tune Phase 2.

Preflight note: golangci-lint not available on this dev host, so the
project preflight target cannot run end-to-end. Verified with
go vet ./spinifex/handlers/ec2/instance/... (clean) and
go test ./spinifex/handlers/ec2/instance/... (pass).

* perf(microvm): hit Phase 2 boot/memory gates

t1→t2 hypervisor: 3224 ms → 264 ms (12×). 128 MiB guest now boots
cleanly without OOM, reverting the temporary 512 MiB bump.

Root causes:

1. build-microvm-image.sh staged the entire chroot into the cpio
   without dropping /boot, embedding a duplicate vmlinuz, Alpine's
   stock initramfs-virt, System.map, and a "boot → ." symlink loop
   (~25 MiB). Decompression peak exceeded 128 MiB. Strip /boot after
   the kernel is copied out, before the cpio. Initramfs drops from
   31 MiB → 11 MiB (53 MiB → 28 MiB uncompressed); total artifact
   42 MiB → 22 MiB.

2. vm/lifecycle.go burned 3 s of fixed sleep on every direct-boot
   launch: 2 s nbdkit pre-exec wait (no nbdkit on direct-boot) and
   1 s post-fork settle (QEMU binds QMP within ~10 ms when there is
   no firmware, ROM, or block layer). Both extracted to
   directBoot-aware helpers — nbdkitPreExecWait collapses to 0, and
   qemuStartSettleWait to 50 ms.

3. KernelCmdline only carried `console=ttyS0 virtio_mmio.device=…`.
   Added boot-time perf flags: quiet loglevel=3 (silence printk over
   115200-baud isa-serial), mitigations=off (KVM guest on trusted
   host, single-tenant LB workload), tsc=reliable, no_timer_check,
   reboot=t, i8042.{nopnp,noaux,nokbd} (microvm has no PS/2).

4. init.sh dropped modprobe virtio_mmio (built-in:
   CONFIG_VIRTIO_MMIO=y) and tightened polling: fw_cfg/iface waits go
   from 10 × 200 ms (up to 2 s) to 5 × 20 ms (up to 100 ms).

Phase 2 gates:
  - t1→t2 ≤ 300 ms       ✅ 264 ms / 281 ms
  - artifact ≤ 50 MiB    ✅ 22 MiB (gate already in build script)
  - ELBv2 e2e green      ✅ 32/33 (pre-existing client-VM failure,
                                   unrelated to microvm path)

* build(microvm): wire build into deploy + distro + release pipeline

Adds install-microvm Makefile target (with grouped-target staleness
detection on vmlinuz/initramfs.cpio.gz), wires it into dev-install.sh
and reset-dev-env.sh, makes 'make deploy' reinstall artifacts when
present, and makes 'make distro-amd64' stage build/microvm/* into the
release tarball staging dir. arm64 distro stays unchanged (no aarch64
microvm artifact yet — Phase 4).

Release workflow gains a setup-go step and a 'make build-microvm-image'
step before 'make distro-amd64' on the amd64 runner so the resulting
tarball includes the kernel + initramfs without a manual copy.

Precursor for the Phase 3 PC-machine LB removal (mulga-siv-69).
Closes mulga-siv-71.

* build(ansible): include microvm artifacts in build role tarball

Adds a build-microvm-image task to the ansible build role and stages
build/microvm/* into the role's release tarball so the install role's
setup.sh run picks them up via INSTALL_SPINIFEX_TARBALL. Skipped
gracefully when the build script is absent (older branches without
direct-boot LB wiring).

* feat(config): enable microvm direct-boot LB path by default

Uncomments the [nodes.<node>.daemon.microvm] section in the generated
spinifex.toml template and sets elbv2_enabled = true so all new
clusters bring up ELBv2 LBs via the direct-boot microvm path. Operators
can opt back to the legacy PC-machine path by flipping the flag to
false in the rendered config.

Required for end-to-end CI on this branch to exercise the direct-boot
path. Existing clusters' configs are unchanged (the template only
affects fresh 'spx admin init' renders).

* fix(microvm): bootstrap apk.static when no host rootfs tool exists

Self-hosted CI runners and the GitHub-hosted ubuntu-24.04 image often
have none of apk, docker, or podman installed. apk-tools is not in the
Debian 13 (trixie) repositories. Without one of these the rootfs build
fails up front with 'no rootfs build tool available'.

When all three are absent, fetch apk-tools-static from the configured
Alpine mirror, extract it to a tempdir, and prepend it to PATH so the
existing native-apk strategy below picks it up transparently. Requires
only curl + tar, both of which are present on every CI runner that can
already check out source.

No-op when apk, docker, or podman is already present.

Unblocks https://github.com/mulgadc/spinifex/actions/runs/25988830244

* revert: drop apk.static bootstrap in build-microvm-image

Reverts 0bd76b7. Self-hosted runners will get docker.io installed
out of band; existing Strategy 2 (docker run alpine:3.20) handles
the rootfs build without host sudo or unsigned package install.

* docs(workbook): drop lb-alpine import for microvm direct-boot LB

LBs now launch via direct-boot QEMU microvm using kernel + initramfs
bundled at /usr/share/spinifex/microvm/, so the legacy lb-alpine system
AMI import is no longer required.

* fix(daemon): own tap devices by daemon user so QEMU can attach without CAP_NET_ADMIN

When the daemon runs non-root (production: User=spinifex-daemon), child
QEMU processes inherit that uid but lack CAP_NET_ADMIN. The kernel's tun
attach check then requires the tap owner uid to match the caller's euid.
Without the `user` flag, `ip tuntap add` defaults to root:root and qemu's
TUNSETIFF fails with EPERM ("could not configure /dev/net/tun: Operation
not permitted").

Surfaced by the e2e-nightly cell-17 microvm LB launch on the ci-pseudo
runner where the kernel enforces strictly; legacy EC2 launches on
ci-single runners happened to attach successfully despite the same code
path. Adding `user $current group $gid` to `ip tuntap add` ensures the
tap is owned by whatever uid the daemon (and its qemu children) run as.
Root daemons skip the flag — they have CAP_NET_ADMIN ambient.

* fix(e2e): redirect lb probe chatter to stderr so stalls are visible

test_http_from / test_tcp_from echoed progress to stdout, which the
callers captured into *_OK vars via $(...). Result: 6+ minute retry
loops ran silently in CI, and the "$ok" comparison never matched
"true" because the captured value contained the full multi-line
chatter. Reachability pass/fail counters were also lost in the
subshell.

Redirect helper output to stderr, leave only the true/false flag on
stdout, and move pass/fail to the caller so they actually count.

* fix(microvm): don't /32 AdvertiseIP via mgmt for internet-facing single-node

buildMicrovmNICs overrode resolveMgmtRoute's deliberate empty return
for the single-node internet-facing case by falling back to
(MgmtBridgeIP, AdvertiseIP). That installed a /32 route to AdvertiseIP
via the mgmt NIC inside the LB microvm. On single-node where the
AWSGW host IP equals the WAN client IP, the /32 also catches reply
traffic for inbound HTTP/TCP to the LB's floating IP — replies leave
via the mgmt NIC with src=data-NIC IP, the host kernel drops the
asymmetric flow, and same-chassis ingress hangs.

resolveMgmtRoute already encodes the correct policy:
  - multi-node any scheme        → explicit MgmtRoute{Gateway,Target}
  - single-node internal         → fallback to (MgmtBridgeIP, AdvertiseIP)
  - single-node internet-facing  → empty (reach AWSGW via VPC SNAT)

Honor it. Matches the legacy lbVMUserData path, whose own comment
flagged the stolen-WAN-return-path symptom this introduced.

Test covers all three branches.

* feat(ansible): dev-deploy playbook for in-place artifact swap

Fills the gap between ansible-dev-install (skips when already installed)
and ansible-dev-reset (full teardown + reinstall + smoketest). Mirrors
Makefile `deploy` target: rebuild + replace binaries and microvm
artifacts on a running node, restart spinifex.target, wait for awsgw.

Skips setup.sh (no user/dir/systemd-unit changes) and smoketest so
iteration is fast. Use ansible-dev-reset when changing systemd units,
helper scripts, logrotate, or setup.sh itself.

Adds:
- roles/deploy/tasks/main.yml — install spx + nbdkit plugin + microvm
  artifacts, with plugindir auto-detection via `nbdkit --dump-config`.
- playbooks/dev-deploy.yml — chains build + deploy roles.
- Makefile ansible-dev-deploy target.
- README playbook table + "when to use which" guidance.

* chore(microvm): remove legacy LB Alpine image build pipeline

Phase 3 microvm removal — strip the PC-machine LB image build
artifacts that direct-boot no longer needs. The microvm initramfs
already carries lb-agent + HAProxy via build-microvm-image, so the
lb.conf manifest, lb-setup.sh chroot script, build-lb-image target,
dev-install / reset-dev-env import steps, and ansible LB-image tasks
all become dead.

build-system-image stays — other manifests (e.g. GPU images) still
use it.

* refactor(microvm): remove legacy PC-machine LB boot path

Phase 3 — direct-boot becomes the only ELBv2 LB launch path.

- Drop SystemInstanceInput.DirectBoot / ImageID / UserData (every LB
  caller set DirectBoot=true; legacy cloud-init userdata is gone).
- Drop ELBv2ServiceImpl.lbVMUserData, systemAMI* fields, SetSystemAMIFunc,
  getSystemAMI, and the lazy-AMI wiring in daemon.startCluster.
- Collapse CreateLoadBalancer to a single direct-boot launch input.
- Collapse daemon.LaunchSystemInstance: drop AMI validation, ImageID
  on RunInstancesInput, UserData base64 encode, GenerateVolumes branch.
  buildDirectBootConfig hardcodes /usr/share/spinifex/microvm and
  isa-serial=on (microvmMachineType no longer takes a flag).
- Drop MicrovmConfig from config.DaemonConfig and the
  [daemon.microvm] section from the spinifex.toml template.
- Prune dead tests (lbVMUserData_*, PCMachine_Unchanged, AMI resolver
  paths) and refresh stale comments that still mentioned lbVMUserData.

ARM hosts have no LB launch path until Phase 4 adds direct-boot on
virt — CreateLoadBalancer on aarch64 fails naturally at QEMU exec.

* docs: drop lb-alpine catalog entry from cluster setup guide

LB system instances no longer use an AMI — direct-boot microvm
artifacts ship in the spinifex package.

* feat(ui): remove LB image import banner + LB-AMI gating

Direct-boot microvm artifacts ship in the spinifex package, so the
LB system AMI no longer exists — the "Load balancer image not imported"
banner and the Create-button disable on the LB list / wizard pages
can never fire. Strip:

- lb-image-missing-banner.tsx component
- hasLbImage / isLbImage / LB_IMAGE_NAME / LB_MANAGED_BY_VALUE from
  system-managed.ts (isSystemManagedImage stays — still used by the
  EC2 Images pages to hide system AMIs)
- Banner gating + ec2ImagesQueryOptions imports from the LB list and
  wizard pages
- The corresponding tests that asserted the banner appears

* revert: restore lb.conf + lb-setup.sh for mulga install pipeline

Phase 3 microvm removal (commit 6313d74) deleted these too early — the
mulga install/iso artifact builders (scripts/tofu-cluster/build-install
-artifacts.sh, scripts/tofu-iso/build-iso-artifacts.sh) still invoke
scripts/build-system-image.sh scripts/images/lb.conf, breaking e2e with
"ERROR: Manifest not found: scripts/images/lb.conf".

Restore both files verbatim so the legacy pipeline keeps building until
the mulga-side migration to microvm-only artifacts lands post-merge.
2026-05-18 15:48:04 +10:00
joshsiv-mulga 26c2c9fa49 fix(setup): replace /dev/stdin in tmpfiles.d write to work without /dev mount in chroot 2026-05-14 15:01:14 +10:00
tomnewton-mulga 28ca689130 feat: VFIO GPU passthrough (#188)
* feat: add GPU discovery package (mulga-992)

Adds spinifex/gpu package with sysfs-based GPU enumeration, IOMMU group
member lookup, and a PCI device ID model table. Vendor-specific enrichment
via nvidia-smi is attempted opportunistically and falls back to the built-in
table when unavailable. All discovery and IOMMU logic is covered by unit tests
using mock sysfs trees.

* feat: add VFIO bind/unbind and GPU pool manager (mulga-993)

Adds gpu.BindVFIO/UnbindVFIO using sysfs driver_override for per-device
driver switching, and gpu.Manager which owns the claim/release lifecycle
for the GPU pool including full IOMMU group binding, rollback on partial
failure, and marking entries unavailable when rebind fails after VM
termination.

* feat: add G5 instance type generator with GPU model support (mulga-994)

- Add GPUModel type, NVIDIAa10g constant, and GPUModelForVendorDevice lookup
- Add generateGPUTypes to emit g5.* types with GpuInfo populated
- Add IsGPUType helper for consumers filtering GPU-capable types
- Update DetectAndGenerate to accept gpuModels []GPUModel parameter

* feat: integrate GPU passthrough into daemon lifecycle (mulga-995)

- Add gpu_passthrough config flag; discover GPUs and build manager at startup
- Gate g5 instance types on GPU pool availability via canAllocateCount
- Claim GPU (VFIO bind) in LaunchInstance; inject vfio-pci QEMU device
- Release GPU (VFIO unbind, rebind to host driver) in stopInstance
- Re-claim GPU on daemon restart when QEMU process is still alive
- Add UseUEFI / OVMF support for x86_64 VMs (optional, falls back to SeaBIOS)
- Fix Claim to use stored OriginalDriver when device is already vfio-pci bound

* feat: add GPU fields to NodeStatus and spx top nodes (mulga-996)

- Add TotalGPUs/AllocGPUs to NodeStatusResponse (zero on non-GPU nodes)
- Populate from gpuManager in handleNodeStatus
- Show GPU (used/total) column in spx top nodes; "-" when no GPUs present

* feat: Ubuntu 24.04 GPU AMI build pipeline (mulga-997)

Extends build-system-image.sh to support Ubuntu alongside Alpine.
Key differences handled: partition table (parted resizepart p1),
bind mounts for DKMS (/proc /sys /dev), apt vs apk, systemctl vs
rc-update. DISTRO defaults to "alpine" for backward compatibility.

Adds ubuntu-gpu.conf manifest and ubuntu-gpu-setup.sh chroot script
that installs nvidia-headless-550-server with DKMS pre-built against
a pinned linux-image-generic kernel, blacklists nouveau, and prevents
unattended-upgrades from invalidating the pre-built module.

* Fixed GPU passthrough and added test script

* feat: always-probe GPU at startup, surface capability in NodeStatusResponse

- Add gpuProbeResult struct and probeGPU() which runs at daemon startup
  regardless of gpu_passthrough config. Checks sysfs for GPUs, IOMMU
  groups, and vfio_pci module presence.
- Store gpuProbe on Daemon struct; split NewDaemon into probe (always)
  and activate (opt-in) phases.
- Populate GPUCapable, GPUPassthrough, GPUModels on NodeStatusResponse
  so operators can see hardware state before enabling passthrough.
- Update 'spx top' GPU column: '-' = no hardware, '0/N*' = capable but
  passthrough not active, 'used/total' = passthrough active.

* feat: SIGHUP hot-reload for GPU passthrough config (mulga-1001)

- Export GenerateGPUTypes for use by the reload path
- Add ResourceManager.reloadGPUTypes: mutates instanceTypes map in-place
  (preserves references held by instanceService) and updates NATS
  subscriptions without full daemon restart
- Separate SIGHUP from SIGTERM/SIGINT: setupReload() listens for SIGHUP
  in a context-aware loop; setupShutdown no longer intercepts SIGHUP
- Add reloadConfig() + applyGPUConfig(): re-reads spinifex.toml on signal,
  handles false→true (re-probe + activate) and true→false (refuse if
  instances running, otherwise deactivate) transitions

* feat: spx admin gpu status/enable/disable commands (mulga-1000)

- admin.SetGPUPassthrough: Go implementation of the idempotent TOML write
  (replaces the inline Python heredoc in spx-test-gpu.sh)
- spx admin gpu status: shows GPU hardware, IOMMU/vfio state, passthrough
  activation, and advertised g5 instance types via NATS NodeStatusResponse
- spx admin gpu enable: checks prerequisites, writes TOML, sends SIGHUP,
  polls until daemon confirms GPUPassthrough=true
- spx admin gpu disable: refuses while GPU instances are running, otherwise
  writes TOML, sends SIGHUP, polls until confirmed
- spx-test-gpu.sh: replace Python TOML heredoc with spx admin gpu enable

* fixed admin

* fix: filter Intel iGPU from passthrough pool, use lspci for consumer GPU names

Discover() now skips non-NVIDIA/AMD vendors so Intel iGPUs never enter
the passthrough pool. enrichFromLspci() uses the system PCI ID database
via lspci -vmm to populate the model name for any card not in the
hardcoded table, without needing nvidia-smi or driver tools.

* fix: grant CAP_SYS_ADMIN and vfio device access to spinifex-daemon

GPU passthrough requires writing to /sys/bus/pci/drivers/vfio-pci/unbind
on instance stop. The kernel gates this on CAP_SYS_ADMIN regardless of
file permissions. QEMU subprocesses also need char-vfio rw access to
open /dev/vfio/N for the passed-through device.

* fixing gpu bining permissions

* working state of gpu passthrough on phyiscal box

* installer grub image fixes

* made gpu-passthrough more user facing

* fixed banner

* fixed banner

* banner fix

* gpu passthrough docs

* preflight tweak

* vpcd fixes to set br-wan to promisc for public IP DHCP processes

* fixed vpcd br-wan promisc and veth pair

* ssh keygen fix

* fixes after running /review-branch

* feat: re-wire GPU claim and device injection after vm.Manager refactor

GPU passthrough claim (VFIO bind) and QEMU device injection were lost
when dev's vm.Manager refactor (#185/#186) moved StartInstance/
CreateQMPClient into vm/lifecycle.go. Re-add both in their correct
new homes:

- daemon_handlers_instance.go: claim GPU before vmMgr.Run() in both
  RunInstances and StartStoppedInstance handlers; release on failure
- vm/lifecycle.go startQEMU(): inject vfio-pci device with x-vga flag
  derived from instance.GPUXVGAEnabled when GPUPCIAddress is set

* fix: Create spinifex user ~/.ssh and keys in firstboot

---------

Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com>
Co-authored-by: Julian Sommer <115516918+juliansommer@users.noreply.github.com>
2026-05-06 09:52:23 +10:00
joshsiv-mulga 9b9bcc5b8f fix(setup): mask dhcpcd.service even when apt install skipped
bc33c72 added the mask but placed it after the SKIP_APT early-return.
CI bootstrap runs setup.sh with INSTALL_SPINIFEX_SKIP_APT=1 against
runners that already have dhcpcd-base, so the mask never ran. On
Debian-13 the auto-enabled dhcpcd.service kept binding br-wan and
racing vpcd's nclient4, reproducing the mulga-siv-32 DORA timeout
on the public-IP allocation path. Lift the disable+mask out of the
apt branch so it runs unconditionally.
2026-04-29 16:10:59 +10:00
Josh Siviour 04f63ad8c6 feat(iso-installer): DHCP race fix + vpcd reconcile gate + ELB mgmt route + HashMAC + diagnostics (#172)
* preflight tweak

* fix: pin gateway LRP to link-local, end intra-cluster ARP collision

Every VPC's IGW gateway-LRP claimed pool.GatewayIP || pool.RangeStart on
attach. Multi-VPC clusters all GARP'd the same .160 with three different
deterministic MACs on the shared br-ext localnet, flapping the upstream
ARP cache and dropping 100% of inbound traffic to dnat_and_snat external
IPs (mulga-siv-26).

handleIGWAttach and reconcileIGW now unconditionally set the gateway
router port to 169.254.0.1/30. The default route's OutputPort already
pins the LRP, so the WAN nexthop need not be on-subnet. Pool IPs stay
allocated only for per-VM dnat_and_snat external addresses, which are
unique by construction.

Self-heal: RetrofitAllGatewayPortNetworks runs at startup and rewrites
stale Networks in place via the new UpdateLogicalRouterPort path. Needed
because Reconcile gates IGW work on "ext switch missing", so a cluster
shipped with the buggy CIDR never re-enters reconcileIGW.

Regression guards: TestTopologyHandler_IGWAttach_MultiVPC_NoIPCollision
and TestReconcileIGW_RewritesStaleGatewayPortNetworks. Existing tests
updated to assert link-local and OutputPort=&gwPortName. Log field
gateway_ip renamed to lrp_network to signal the semantic shift.

* fix: rewrite utils.HashMAC to SHA-256 / 46-bit output

The old 24-bit rolling hash with literal class prefix had birthday-paradox
collision probability of 1% at ~580 ids and 50% at 4096 — well within the
range of a single deployment's resource population (LRPs, ENIs, dev/mgmt
NICs). On a shared L2 segment, two clusters could trivially produce
duplicate MACs, breaking neighbour discovery and DHCP.

Switch HashMAC to SHA-256 across the entire input, taking the low 6 bytes
and forcing the IEEE 802 reserved bits (bit0=0 unicast, bit1=1 LAA) on the
first octet. Output entropy goes from 24 bits to 46 bits — 1% collision
boundary moves from ~580 to ~1.2M ids.

Drop the redundant prefix arg: it was no longer the literal output prefix
under the new scheme, just folded into the hash input. Class disambiguation
moves to the caller, where it's explicit. Three of four callers had nothing
to disambiguate (eni-, subnet-, gw-vpc- ids are already unique); dev and
mgmt NICs share instance.ID and now compose "dev:" / "mgmt:" tags.

Also consolidate vpcd.generateMAC, which was a local duplicate of the
broken algorithm rather than a HashMAC wrapper, into a HashMAC delegation.

Plan: docs/development/bugs/vpcd-mac-collisions-shared-l2.md
Bead: mulga-siv-27

* fix: pin HashMAC first octet to 0x02

Previous impl forced only the IEEE 802 reserved bits (bit0=0 unicast,
bit1=1 LAA) on the first octet, leaving the upper 6 bits hash-derived.
Technically valid LAA unicast, but produced MACs like 4a:.. and fe:..
that visually encroach on vendor OUI space and tripped CI/ops checks
expecting all generated MACs to start with 02:.

Pin byte 0 to literal 0x02; hash bytes 1-5 from sha256[0:5]. Output
entropy drops from 46 to 40 bits — birthday-paradox 1% collision at
~150k ids, still 256x the old 24-bit bound (~580).

* chore(e2e): dump cross-chassis OVN state on guest SSH failure

Adds chassis registrations, port_binding claims, gateway_chassis rows,
ovs-vsctl topology, Geneve tunnel state, and br-int tunnel flows to
dump_guest_ssh_diagnostics so we can pinpoint where the cross-chassis
dataplane stalls (cr-gw chassis vs remote chassis with the VM bound).

* fix: gate vpcd startup reconcile behind NATS KV leader election

N vpcds in a multi-node cluster all hit Get-then-Create on Logical_Router
with no atomicity, producing duplicate rows that ovn-nbctl rejects with
"Multiple logical routers named '...'. Use a UUID."

Add AcquireReconcileLeader using NATS KV CAS (kv.Create on a single key
in spinifex-vpcd-reconcile bucket). Only the elected vpcd runs Reconcile,
ReconcileFromKV, and the two retrofit passes — others Subscribe and rely
on the vpcd-workers queue group for runtime events. MaxAge=60s on the
bucket caps recovery time when a leader crashes mid-reconcile.

Falls through (elected=true) when KV is unavailable so first-boot does
not deadlock on a missing JetStream.

mulga-siv-29

* fix(elbv2): force mgmt host route for internal-scheme LBs (mulga-siv-30)

Single-node CI e2e Phase 3b ALB internal hangs in 'provisioning' for 270s
because the lb-agent inside the ALB VM has no return path to AWSGW.

The gateway-URL decision tree in daemon.wireLBAgentConfig picks advertiseIP
for single-node and deliberately skips adding the /32 mgmt host route — the
WAN-return-path concern in the comment is real but applies only to
internet-facing LBs, which have an EIP and an OVN dnat_and_snat pair that
gives reply traffic a way home. Internal LBs have no EIP / no SNAT, so when
the agent dials advertiseIP the reply targets the VM's private subnet IP from
the host's WAN with no route back.

Make lbVMUserData scheme-aware. New helper resolveMgmtRoute returns the
existing (MgmtRouteGateway, MgmtRouteTarget) when set (multi-node case) and
falls back to (MgmtBridgeIP, AdvertiseIP) when scheme is internal — only
internal LBs need the /32 route, so internet-facing single-node still gets
no bootcmd and the host-initiated WAN path stays clean.

Daemon now exposes MgmtBridgeIP and AdvertiseIP unconditionally so the
fallback has the inputs it needs.

* fix(daemon): stub sudoCommand in TestSetupComputeNode_ValidatesArgs (mulga-siv-31)

The test was calling real SetupComputeNode("chassis-test", ...) which shelled
out via sudoCommand to set external_ids:system-id=chassis-test on the host's
live OVS. On a dev box with OVS installed this overwrote the persistent UUID
(owned by openvswitch-switch and re-applied only on reboot), so vpcd's
discoverChassis filtered out the legitimate SBDB chassis row as 'stale local'
and crashlooped — taking out all VPC ops including ALB ENI provisioning.

Bind sudoCommand to a var so tests can swap it. Stub it in the test to return
exec.Command("/bin/false") and assert SetupComputeNode returns an error. The
test's intent (signature + error-path coverage) is preserved; nothing on the
host is touched.

* chore(vpcd): log DHCP Acquire concurrency + duration (mulga-siv-32)

Diagnostics-only change to surface whether nightly e2e cell-3 / cell-8
DORA timeouts correlate with concurrent Acquire calls on the same
bridge. Tracks per-bridge in-flight count and wallclock duration of each
Acquire; logs WARN on failure with both fields, DEBUG on success.

No behavioural change.

* ci(e2e-nightly): dump cluster journals on failure (mulga-siv-32)

run-multinode-e2e.sh dumps node journals via its own EXIT trap, but
run-cert-e2e.sh / run-lb-e2e.sh / reboot-e2e do not. When those scripts
fail the cluster is destroyed in Teardown without surfacing any daemon
logs, blocking root-cause analysis.

Add a workflow step that runs after the test scripts but before
Teardown when a previous step failed, ssh'ing to each node and pulling
the last 200 lines of every spinifex-* unit. Best-effort: skips
gracefully when inventory or nodes are unreachable.

Diagnostic-only; no behavioural change to the test path.

* fix(setup): mask dhcpcd.service to stop it racing vpcd's DHCP client (mulga-siv-32)

Debian 13 (Trixie) auto-enables a standalone dhcpcd.service when
dhcpcd-base is installed. It binds br-wan and races vpcd's in-process
nclient4 client for upstream OFFERs, draining the lab DHCP pool with
duplicate leases and causing intermittent DORA timeouts in the e2e
public-IP path (worst on cell-8 real-multi/dhcp/debian-13).

The ISO installer already masks the unit at install time
(cmd/installer/install/install.go:316). The binary install path used by
e2e nightly missed it, so debian hosts installed via setup.sh ran with
both DHCP clients live. Mirror the ISO mask here.

Ubuntu hosts are unaffected (dhcpcd-base does not auto-enable
dhcpcd.service on Noble).

* ci(e2e-nightly): also dump dhcpcd.service state on failure (mulga-siv-32)

Confirms or rules out the dhcpcd-vs-vpcd race hypothesis. Pulls the
dhcpcd.service journal alongside the spinifex-* units, plus
systemctl is-enabled / is-active and the DHCP client port (UDP 68)
listener so we can see directly whether dhcpcd is running and bound
to br-wan when an Acquire times out.

---------

Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com>
2026-04-29 14:38:29 +10:00
Ben Duncan 27d7fdd12b Latest changes re ISO and binary install path 2026-04-20 15:14:32 +10:00
Ben Duncan b591c04880 firstboot tweaks 2026-04-20 11:27:49 +10:00
Ben Duncan a64ee2b2da ISO tweaks 2026-04-17 14:22:34 +10:00
Ben Duncan 402a04e1b9 Merge branch 'feat/iso-installer' of github.com:mulgadc/spinifex into feat/iso-installer 2026-04-16 09:29:15 +10:00
Ben Duncan 25d02707d0 ISO tweaks 2026-04-16 09:29:00 +10:00
Julian Sommer 7d6e0780b5 feat: action rate limiting (#140) 2026-04-15 12:19:30 +10:00
Julian Sommer 1ad03bb518 feat(gateway): per-IP auth failure rate limiting (#138) 2026-04-15 09:56:04 +10:00
Julian Sommer a4ae813e38 fix: recursive chmod on shared data dirs so existing image files are group-readable
chmod 0770 without -R only affected the top directory; pre-existing files
(e.g. images imported while owned by another user at mode 0600) stayed
unreadable to the spinifex group, breaking image import on upgrade paths.
2026-04-14 11:05:01 +10:00
Julian Sommer e0118975d1 fix: setup.sh 2026-04-14 10:17:01 +10:00
Julian Sommer 36e3481ca3 fix: enable spinifex.target so services autostart on boot 2026-04-14 10:14:09 +10:00
Julian Sommer 515c313e07 fix: setup.sh newgrp 2026-04-14 10:07:59 +10:00
Julian Sommer 48c90b795a feat: migration framework (#127) 2026-04-10 14:34:15 +10:00
Julian Sommer e27d909e8d feat: move NBD sockets to /run/spinifex/nbd/ and enable PrivateTmp (#119) 2026-04-09 11:11:54 +10:00
Julian Sommer 9a7e914d28 feat: awsgw directory (#117) 2026-04-08 15:19:29 +10:00
Julian Sommer a56a2baf1f feat: privilege separation (#114) 2026-04-07 16:22:19 +10:00
Ben Duncan e5b6204875 Fix service helper sequence 2026-04-02 13:53:29 +10:00
Ben Duncan 21aa1296c9 systemd tweaks for binary install to correctly function 2026-04-02 13:35:52 +10:00
Julian Sommer c51ea0c29d fix: make download checksum verification mandatory 2026-04-02 09:56:57 +10:00
Julian Sommer b76953bfb4 doc tweaks 2026-03-31 13:02:21 +10:00
Julian Sommer 216842cc1b fix: enable ovn on boot 2026-03-27 09:41:23 +10:00
Ben Duncan edcc53b947 Merge commit '820f620e34006699de1105859301146aaf491ca5' into vpc-public-subnet
# Conflicts:
#	cmd/spinifex/cmd/admin.go
#	docs/installing-spinifex/README.md
#	scripts/setup.sh
#	spinifex/admin/admin.go
#	spinifex/admin/network_detect.go
#	spinifex/handlers/iam/service_impl.go
2026-03-25 14:16:47 +10:00
Ben Duncan 3d73dd180b fix: add dhcpcd-base to system dependencies for DHCP pool mode
DHCP pool mode requires dhcpcd-base (/usr/sbin/dhcpcd) to obtain
leases from the router. Added to Makefile install-system, setup.sh
binary installer, and source-install docs.

Closes: mulga-753
2026-03-25 12:05:21 +10:00
Julian Sommer bdf0522895 feat: admin init auto install cert 2026-03-25 09:06:50 +10:00
Ben Duncan 78bc0d989d docs: update install guides + setup.sh for new setup-ovn.sh flags
- All guides: OVN setup before admin init (consistent ordering)
- Single-node + source-install: Replace --external-bridge/--external-iface
  with auto-detection + --wan-bridge/--wan-iface/--macvlan options
- Multi-node: Simplify examples (auto-detect WAN bridge), show override
  options in prose
- setup.sh: Update "next steps" to match single-node guide, add
  --wan-bridge/--macvlan guidance for physical NIC setups

Part of mulga-742.
2026-03-24 16:17:35 +10:00
Julian Sommer 7d43d0f782 hopefully last rename 2026-03-18 13:24:45 +10:00
Ben Duncan 5d93786995 refactor: rename hive to spinifex in all shell scripts
- Update scripts/: start-dev, stop-dev, dev-setup, setup, setup-ovn, etc.
- Update tests/e2e/: all E2E test scripts
- Update scripts/iac/: rename hive-test.sh → spinifex-test.sh, update TF files
- Update config/: rename hive.service and install script
- Binary refs use spx, env vars use SPINIFEX_, paths use spinifex
2026-03-18 01:04:12 +00:00
Ben Duncan 4c4683ba0c installer tweaks for sudo 2026-03-16 12:04:06 +00:00
Ben Duncan a458a28406 new binary mode and systemd process 2026-03-16 11:57:52 +00:00