Three blockers fixed for VPC public subnet E2E on single-node:
1. OVN SB stale data: reset-dev-env.sh now deletes both NB+SB DB files
instead of individual NB cleanup. Eliminates ovn-controller commit
failure loop from stale chassis/port binding entries.
2. Chassis name mismatch: reset-dev-env.sh passes --chassis-id=chassis-node1
to setup-ovn.sh, aligning OVS system-id with vpcd's chassis-{nodeName}.
3. Macvlan unicast filtering: switched to centralized NAT (no external_mac
on DNAT rules), set nat-addresses=router on localnet ports, and vpcd
aligns macvlan MAC with OVN gateway router MAC on startup. Macvlan only
delivers unicast matching its own MAC — this ensures inbound traffic
from the LAN reaches OVS/OVN.
Also fixed: DNS for VMs. admin init auto-detects host DNS servers via
resolvectl, stores them in spinifex.toml dns_servers field, and vpcd
propagates them to OVN DHCP options. Fallback: 8.8.8.8 + 1.1.1.1.
Validated E2E: inbound ping, SSH, outbound ping, DNS, curl, apt update.
The single-nic IP migration path was fragile and caused connectivity
issues during setup. macvlan is now the only bridge strategy — always
creates spx-ext-{nic} on the WAN NIC. Removed --single-nic flag,
SingleNIC config/detection fields, and updated all docs.
When setup-ovn.sh migrates the WAN IP from a physical NIC to
br-external, systemd-resolved loses its DNS association (DNS servers
are per-interface). This breaks hostname resolution for everything
on the host — git, apt, curl, SSH all fail.
Now captures DNS config from the original interface before migration
and re-associates it with br-external via resolvectl. Falls back to
8.8.8.8 if no DNS was configured on the original interface.
When setup-ovn.sh migrates the host's WAN IP to br-external, stopping
openvswitch-switch destroys the bridge and the host loses all network
connectivity — unreachable via SSH, requires console reboot.
Now checks if br-external has an IP before stopping OVS. If it does,
skip the OVS stop and only stop ovn-controller + ovn-central. OVS is
infrastructure — bridges must survive service stop/start cycles.
Discovered during 3-node E2E testing: stop-dev.sh killed all 3 nodes'
WAN connectivity simultaneously.
spx admin init now works with zero external networking flags:
- Auto-detects WAN interface, gateway, prefix from ip route
- Auto-detects single-NIC vs multi-NIC mode
- Defaults to nat mode with DHCP for gateway IP
- Prints detected topology with interface roles
setup-ovn.sh gains --dhcp flag: obtains a DHCP lease on the
macvlan/bridge interface for the OVN gateway SNAT address, then
writes gateway_ip into spinifex.toml. Tested on VM: macvlan gets
separate IP from router DHCP, host keeps its original IP.
Three tiers of external networking:
- Zero flags: auto nat+DHCP (VMs get outbound internet)
- --external-pool=start-end: pool mode (VMs get public IPs)
- --no-external: overlay only (no internet for VMs)
Add --single-nic flag to setup-ovn.sh. When used with --external-bridge,
creates a macvlan sub-interface (spx-ext-{iface}) in bridge mode off the
host's NIC instead of adding the NIC directly to br-external. The host
keeps its IP — no migration, SSH-safe.
Strategy selection:
- Dedicated NIC: --external-iface=eth1 (add directly)
- Single NIC: --external-iface=eth0 --single-nic (macvlan)
- IP migration: --external-iface=eth0 (legacy, no --single-nic)
Add single_nic bool field to VPCDConfig for per-node config. Different
nodes in a cluster can use different strategies. Unit test verifies
single_nic parsing alongside external_interface.
Add external IPAM module (CAS-based IP allocation from admin-defined
pools in NATS KV). Supports multi-pool with region/AZ scoping, pool
fallback logic, gateway IP reservation, and concurrent allocation via
CAS retries. 12 unit tests covering allocation, release, exhaustion,
CAS conflict, multi-pool, fallback, validation, and idempotent init.
Add --external-bridge flag to setup-ovn.sh: creates OVS bridge
br-external, adds WAN NIC, migrates host IP to bridge, and sets
ovn-bridge-mappings=external:br-external for OVN localnet ports.
Add commented [network] section and external_interface to spinifex.toml
config template for discoverability.
Redistribute E2E tests between single-node and multi-node suites, slim
down pseudo multi-node suite, and remove directory creation from
dev-setup.sh so spx admin init is the single source of truth for
~/spinifex/ setup.
The MIN_LOC=100 threshold checked total diff lines, not instrumentable
lines. A commit with many non-instrumentable lines (structs, comments)
but only 1-2 instrumentable lines would unfairly fail at 0% coverage.
Add a minimum instrumentable lines threshold (5) so the check skips
when the sample size is too small to be meaningful.
Extract duplicated respondWithError closures into a single package-level
function. Guard against nil ImageId in handleEC2RunInstances to prevent
panic under race conditions. Fix diff-coverage base ref for main branch.
is_multinode() counted all [nodes.*] TOML subsections (daemon, nats, awsgw,
etc.) instead of just top-level node entries. A single-node config has ~8
such sections, causing the single-node Docker E2E to use coordinated cluster
shutdown and exit with code 254.
Fix grep to match only [nodes.X] (not [nodes.X.Y]) and preserve the original
test exit code in the cleanup trap.