mirror of
https://github.com/mulgadc/spinifex.git
synced 2026-10-23 12:47:48 +00:00
261d5d505e9efa07109bbe9495c19db7d057bebe
3 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
cae76ba1b6 |
test: complete the e2e live-vs-mock rebalance (epic mulga-8oyg3) (#566)
* test(volume): assert chunk GC stays wired on in CreateVolume GCEnabled was zero-valued at every viperblock construction site for a long time and no test noticed. It is not part of viperblock.VBState, so it never round-trips through a saved config.json and cannot be observed by reading volume state back. Extract the viperblock.VB assembly out of CreateVolume into buildVBConfig so the GC wiring is assertable directly against the returned config, without a live viperblock or S3 backend. The config is returned by pointer because viperblock.VB carries atomic.Uint64 fields that vet's copylocks check rightly refuses to see copied. * test(e2e): snapshot backend byte accounting before volume purge DeleteVolume purges a volume's entire backend prefix, including any chunks a leak left behind, before anything measures it. That is the same masking that hid the storage-growth leak in production: a passing E2E cannot fail on backend growth when the evidence is deleted first. Snapshot the volume's backend chunk footprint in EnsureVolume's cleanup closure, immediately before DeleteVolume, so every volume the shared teardown path purges is measured rather than silently discarded. The snapshot is always taken and logged; the hard ratio check additionally runs for callers that registered a guest-written-bytes baseline, since most callers never attach or write to the volume they create and so have no baseline to compare against. The tolerance is the RS(2,1) erasure floor widened for per-chunk header and tail-chunk overhead. It is sized to distinguish unbounded growth from a footprint settling at the floor, not to catch bounded residual garbage. The check is non-fatal inside the cleanup callback: t.Fatalf's runtime.Goexit would abort the DeleteVolume call queued behind it and turn a reported leak into a real one. * test(e2e): add memory-constrained concurrent-write durability regression The existing durability tests write one 4MiB sentinel, sequentially, on a comfortably sized guest, which is the exact inverse of the known-open data-loss bug: acked writes read back zero-filled after a cold reread when a guest is memory-starved during concurrent writeback. No happy-path test can reach it, because the fault lives in the intersection of memory pressure, write concurrency and cache-cold reread. Add a suite that encodes those three conditions together: a guest discovered at or below the working set, N parallel large writers launched as background jobs in a single command so they genuinely overlap, swap disabled, then sync and drop_caches before rereading. Assertions are per stream rather than aggregate so a failure names the losing writer instead of leaving whoever reads it to re-derive which of N writers lost data from one combined digest. GuestExec gains a timeout-parameterised variant. Its fixed two-minute default is sized for sub-second payloads, and a multi-gigabyte write to a network-backed volume would exceed it, so the suite would have failed by timeout while looking like it had caught the corruption. The budget scales with the working set, and a deadline is reported distinctly from a data mismatch so the two red states are never confused. The suite is dispatchable but deliberately absent from the default SUITES: the bug it reproduces is still open, so it is expected to fail and must not sit in a merge-gating path. It is registered in the workflow allow-list so it stays discoverable rather than being buried behind a skip. Also record on the live IAM instance-profile test why its assertions were not moved down to the integration tier, so the trace is not repeated. * test(e2e): drop backend byte accounting, assert a node-wide delta instead The accounting helper listed the internal predastore bucket to attribute bytes per volume. That listing is refused unconditionally: predastore authorises bucket access by same-account ownership, and the bucket belongs to the service account, so a test caller gets 403 no matter what it holds. Granting the test a service credential would invert the trust boundary to buy a measurement, which is the wrong trade. Replace it with what the S3 surface actually permits: sample node-wide allocated bytes either side of the write and bound the delta against the bytes the guest wrote. Coarser, but it measures something real rather than depending on a call that cannot succeed. The tolerance moves into the suite that uses it. It encodes RS(2,1)'s 1.5x expansion floor plus headroom; a cluster running the recommended RS(3,2) has a 1.667x floor and only ~12% of margin left, so the constant needs revisiting if the encoding changes. * revert: drop memdurability e2e suite The suite asserted the guest read back what it wrote after a memory-constrained concurrent write, but the assertion could not fail for the reason it claimed: it compared the guest's own read against the guest's own write with the page cache still warm, so it passed whether or not the data reached the backend. A test that is green on a build with a known-open durability bug is worse than no test — it advertises coverage that does not exist. Removes the suite and its Makefile/workflow wiring, plus DiscoverInstanceTypeAtLeastMemory, which had no other caller. GuestExecTimeout stays: GuestExec now delegates to it, and the old two-minute hard cap it replaced was a latent trap for any long guest command. * test(e2e): add partial-block concurrent-write durability suite Replaces the removed memdurability suite, which passed on a build that still carried the bug it claimed to test. The engine reaches its read-modify-write path only for a partial block; a fully covered block takes a full-overwrite branch that reads nothing and can lose nothing. The old workload wrote through ext4 with 1 MiB buffers, which the filesystem coalesced into aligned full-block requests: block-layer tracing recorded zero unaligned and zero sub-4096 requests, so the path under test never ran, and writers 4 MiB apart could not collide on a block even in principle. This suite writes the shape the defect needs. Two writers issue concurrent O_DIRECT writes into disjoint halves of the same 4096-byte blocks on a raw, unformatted device, stamping every half with the round number, then drop the page cache and reread with O_DIRECT asserting every half carries the final round. One half reading back at an earlier round is the signature of the lost update. The old suite also could not fail even had it reached the path: its write phase ended in 'wait; sync; sha256sum' and reported sha256sum's exit status, while bare wait returns 0 unconditionally, so writer errors were invisible and a backend ENOSPC presented as a pass. Here each writer's exit status and exact byte count are asserted before any durability claim is made. Working set is 8 MiB rather than 2048 MiB, and the volume is deleted on teardown; the predecessor left roughly 3 GiB of backend per run and twice drove a node under the nearfull watermark. Dispatchable but not in the default suite list until a green run and a demonstrated fail-first against a pre-fix engine exist. * test(e2e): let the fixture own the working-set volume delete The suite deleted the volume in its own cleanup and the fixture deleted it again on close, so every run ended with an InvalidVolume.NotFound from the second attempt. Detach stays — DeleteVolume against a still attached volume is what leaks volumes on teardown — and the delete is left to the fixture so the volume is released exactly once. * test(e2e): gate merges on the partial-block durability suite Verified on one node with the same test binary and workload, varying only the engine: 1758 of 8192 halves reverted a generation against the pre-fix build, 0 of 8192 against the fixed one. That is the fail-first evidence the suite needed before it could be trusted to gate anything. Adding it to the default suite list rather than leaving it dispatchable is the point. Its predecessor sat outside every path that runs, which is how it survived long enough to be discovered green on a build that still lost data. * test(integration): cover the ECR data plane in the front gate The live ecr/ suite drove docker, crane and skopeo against a real registry, yet none of it boots a guest: it needs a registry, an object store and an HTTP client. The in-process gateway already serves the OCI Distribution v2 surface on an ephemeral port with a memory-backed object store, so these run here in 0.18s instead of behind full provisioning. Covers the three claims the live tests made beyond authorization, which is already down here: a push/pull round trip asserting blobs and manifests read back byte-identical, refusal to auto-create a repository on push, and retagging an existing manifest without disturbing the original tag. Content is compared rather than status codes alone. A registry that stores a blob under the wrong digest, truncates it, or serves a different one answers 200 to every request in the sequence. The capacity/load leg deliberately stays live: it exists to put real parallel pressure on a real predastore, and a memory-backed object store cannot make that claim. * fix(e2e): make volume teardown release the volume before deleting it Fixture cleanups drain LIFO, so a suite that creates its instance before its volume tears the volume down first, while it is still attached. DeleteVolume answered VolumeInUse, nothing retried, and the volume was stranded on the node. Reordering the chain cannot fix this — registration order has no way to express the instance/volume dependency. Instead teardown is now self-sufficient for any creation order: it force-detaches, waits for the volume to reach available, and only then deletes. Instance teardown waits for terminated for the same reason, since TerminateInstances returns as soon as the request is accepted. Two things kept the leak invisible. A failing cleanup was logged and forgotten, so a run stayed green with resources left behind; failures are now reported as leaks, failing the bound test or surfacing through Close() for TestMain to fail the run. And a panic in one cleanup aborted the whole chain, stranding every resource behind it; each callback is now isolated. RegisterVolumeTeardown and the fixture had grown separate teardown paths, only one of which detached. Both now share it. |
||
|
|
92b775951b |
fix(network): poll second-VPC transit SNAT in natuplink + log AddSNAT install (#541)
Phase 8 of TestNATUplink checked the second VPC router's lr-nat-list with a single non-polling assert; the igw-default-snat row commits a beat after the gateway LRP appears, so the read raced the OVN commit and intermittently saw an empty list (flaky CI red). Wrap it in EventuallyErr, matching the sibling LRP and host-route polls in the same phase. AddSNAT logged only on the idempotent-skip path, so the first install was silent and RCA could not tell a late SNAT from a missing one. Emit an install log keyed by router + vpc_cidr + external_ip. |
||
|
|
e1c4f85a36 |
feat: routed-NAT external mode with two-tier ingress (#475)
* feat(network): add routed uplink mode, Routed wiring, and NAT egress rule helper * feat(external): route gateway LRP over transit pool and install VPC SNAT in routed NAT mode * feat(vpcd): support bridge_mode=nat (routed uplink, transit pool, egress rules) * feat(daemon): register EIP handlers unconditionally with disabled-mode stub; seed default subnet per external mode * feat(admin): support --external-mode=nat and suggest it for non-bridgeable uplinks * feat(scripts): add --nat-uplink routed mode to setup-ovn.sh * test(e2e): add routed-NAT single-node natuplink suite Covers the external_mode=nat lane end to end on a nat-initialized node: host transit wiring (veth, br-ext port, ip_forward, iptables egress rules), spinifex.toml contents, disabled EIP surface (empty describe-addresses, UnsupportedOperation on allocate), default subnet MapPublicIpOnLaunch=false, OVN gateway LRP + VPC SNAT on the transit /24, guest outbound egress proven via a serial-console probe (nat mode has no inbound path), and unique transit gateway IPs across VPCs. Suite self-gates on external_mode=nat; registered as e2e-natuplink and in SUITES_BUILD so it compiles in CI. Manifest entry stays commented until CI can provision a nat-mode environment. * feat(ovn): Address_Set CRUD and NAT exempted_ext_ips column Adds the exempted_ext_ips column (optional strong Address_Set ref) to the nbdb NAT model, Address_Set ensure/get with wait-op create semantics, and an in-place SetNATExemptedExtIPs update on the client interface, live client, and mock. Test NB schema gains the column and covers insert-resolves-UUID, converge, clear, and missing-NAT paths. * feat(policy): exempt address set on routed SNAT/EIP rows Adds WithSNATExemptSet so routed mode stamps exempted_ext_ips (the spinifex_nat_exempt Address_Set: transit /24 plus operator extras) on IGW snat and EIP dnat_and_snat rows, keeping VM replies to host-initiated flows un-NATted. AddSNAT gains an idempotency guard keyed on (router, VPC CIDR) with stale-IP replacement, and both AddSNAT and the AddEIP idempotent-skip path patch the ref in place on pre-existing rows. The set is a singleton strong ref and is never deleted. Non-routed modes are unchanged. * feat(host): VPC ingress route primitives for routed-NAT mode EnsureVPCIngressRoute / RemoveVPCIngressRoute manage the host route that sends VPC-CIDR traffic into OVN via the gateway LRP transit IP on the spx-nat veth. Replace/del semantics keep both idempotent; a missing route on removal is not an error. * feat(external): routed ingress leg on IGW attach/detach, reconcile-safe AttachIGW's routed leg now also installs the host VPC ingress route via RoutedIngressHooks, and re-runs on the already-attached path so the reconcile loop restores host routes (and patches legacy SNAT exempt refs) after a reboot — OVN state survives restarts but host routes do not. DetachIGW removes the route alongside the SNAT. vpcd wires the hooks and the spinifex_nat_exempt set (transit /24 + [network] nat_exempt_cidrs, validated nat-mode-only) exclusively in routed-NAT mode; pool/veth/direct pass nil hooks and are unchanged. * test(natuplink): Tier 1 host-ingress phase; docs for jumpbox pattern New Phase 7 asserts the automatic ingress tier: host route to the VPC CIDR via the gateway LRP transit IP, exempted_ext_ips ref on the SNAT row pointing at spinifex_nat_exempt (containing the transit /24), and — after opening the SG from the transit net (default-closed, AWS parity) — ping and an sshd TCP handshake against the instance private IP from the host, which proves the un-SNATted return path. Phase 8 additionally waits for the second VPC's ingress route to appear on IGW attach. vpc-networking README documents the jumpbox pattern, SG note, and nat_exempt_cidrs. * feat(config,admin): public wan pool alongside nat-transit Restructure admin config generation from single-pool scalars to a Pools slice so nat mode can emit both the transit pool and an optional public wan pool. nat mode now accepts --external-pool/--external-source (plus --external-bind-bridge/--gateway-ip when a public pool is requested), validated by the shared resolvePublicPoolFlags helper also used by pool mode. Transit pool always renders first so the IGW allocator picks it. Formation wire format unchanged (nat mode is single-node only). * feat(daemon): enable EIP service and auto-assign in nat mode with public pool External IPAM (and with it the real EIP service, RunInstances public IP auto-assign, and MapPublicIpOnLaunch on default subnets) now activates whenever public pools exist: pool mode as before, plus nat mode when a wan pool rides alongside the transit segment. The transit pool is filtered out of IPAM — its addresses are gateway-LRP plumbing, never allocatable EIPs. Transit-only nat configs keep the disabled EIP stub. * feat(host): per-EIP ingress primitives for routed-NAT mode DetectUplinkFor parses ip route get to find the interface and source IP facing the pool gateway (re-run per ensure: WiFi/cellular uplinks move). EnsureEIPIngress steers an EIP into OVN with a /32 route via the VPC gateway LRP transit IP (src-hinted so host-local traffic still DNATs), answers ARP for the EIP with a proxy neighbor entry (L3 only, same MAC, WiFi-safe), sends gratuitous ARP, and adds per-EIP FORWARD accepts for DROP-policy hosts. RemoveEIPIngress mirrors; missing state tolerated. * feat(policy,vpcd): host EIP binder option on NATManager WithHostEIPBinder injects routed-mode host plumbing hooks. AddEIP binds after priming on both the fresh-add and idempotent-skip paths (host routes and proxy-ARP are volatile even when the OVN row survives, so reconcile re-ensures them after reboot); DeleteEIP unbinds best-effort. The next hop comes from the new gatewayPortIP helper reading the gateway LRP's stamped spinifex:gateway_ip (Networks fallback), with the ext-ID key now an exported policy const shared with the external package. vpcd selects the IGW pool by name instead of index — with two pools in nat mode the gateway allocator must stay on the transit pool — and wires the binder over host.EnsureEIPIngress/RemoveEIPIngress when a public pool is present. EnsureEIPIngress gains an uplink hint so dhcp-sourced pools (gateway unknown until lease) proxy-ARP on their bind bridge. * feat(dhcp): interface-MAC lease variant with MAC-keyed-router detection dhcp_mac = "derived" (default) | "interface" on external pools. The interface variant leases with the bind interface's own MAC — WiFi/WWAN uplinks drop frames with foreign source MACs, so derived chaddr MACs never complete DORA there. Option 61 stays the lease discriminator. UseIfaceMAC threads AllocateRequest → NATS wire → nclient4 → lease and persists through KV so restart re-acquires repeat it. Routers that key leases on MAC and ignore client-id would hand every lease the same IP; the manager detects an ACK matching the interface's own address or another client-id's live lease, releases the colliding lease, and hard-errors advising a static range instead. admin init auto-writes dhcp_mac="interface" for nat-mode public dhcp pools bound to non-bridgeable uplinks (wlan/wwan/ppp). * test(natuplink)+docs: Tier 2 EIP ingress e2e phases and public-pool docs The natuplink suite now detects a public (non-transit) pool in spinifex.toml and switches lanes: Tier-1-only configs keep the EIP-disabled and no-public-IP assertions; public-pool configs assert the EIP surface is enabled, the default subnet has MapPublicIpOnLaunch=true, instances auto-assign public IPs, and a new Phase 9 exercises the full EIP ingress lifecycle — host /32 route via the gateway LRP, proxy-ARP on the uplink, per-EIP FORWARD accepts, exempt-stamped dnat_and_snat, TCP handshake to the EIP, reconcile replay across a vpcd restart, and teardown on disassociate. Docs: vpc-networking README gains a public-pool section for routed-NAT nodes (init flags, dhcp_mac=interface behaviour, host-to-EIP caveat) and an updated mode comparison; COMMANDS.md notes nat-mode EIP support behind a public pool. * fix(setup): whitelist iptables, neigh sysctl, and arping for spinifex-vpcd Routed-NAT mode shells out to iptables for the transit masquerade and per-EIP FORWARD accepts, tunes proxy_delay, and sends gratuitous ARP for host-delivered EIPs. Without these sudoers entries vpcd crash-loops with "command not allowed" on nat-mode nodes. * fix(ovn): scope DeleteStaticRoute prefix match to the target router Every VPC router carries a 0.0.0.0/0 static route, so an unscoped cache match could grab another router's row and fail with a referential integrity violation, wedging IGW attach on multi-VPC nodes. Match only rows referenced by the target router, mirroring FindStaticRoute. Mock updated to the same semantics, with a regression test covering drift replacement across two routers. * fix(reconcile): always replay AttachIGW so host ingress state is re-ensured applyIGWs skipped AttachIGW whenever the gateway switch port existed in actual state, so the already-attached re-ensure path never ran and routed-NAT host ingress routes lost on reboot were never reinstalled. AttachIGW is idempotent; run it unconditionally. * fix(vpcd): resolve duplicate-CIDR host ingress route collisions, bootstrap VPC wins Every account's default VPC shares 172.31.0.0/16, so Tier-1 host routes collide on the single host route table and the last IGW attach silently stole the route (route replace). Pass vpcID and the gateway LRP IP through RoutedIngressHooks; the bootstrap VPC always installs its route, other VPCs only install when the CIDR is free and only remove a route their own gateway IP holds. Adds host.VPCIngressRouteVia to read the current route holder. * ci(e2e): add nightly cell 19 for routed-NAT single-node suite Cell 19 bootstraps with --external-mode=nat plus the CI static pool as the public wan pool and runs the natuplink suite, covering the Tier-1 transit datapath and Tier-2 EIP ingress. The run step exits 0 when natuplink.test is absent from the tests tar so scheduled runs against branches predating the suite stay green. * fix(admin): nat-mode init summary reflects configured public pool The summary printed 'outbound-only — no public IPs/EIPs' even when --external-pool/--external-source configured a public wan pool. Print the pool range (or dhcp bind) and note EIPs are enabled. * fix(eip,vpc): thread ctx through disabled EIP stub and NAT call sites Reconcile the routed-NAT branch with dev's ctx-first service APIs after rebase: DisabledEIPService and its tests take ctx to satisfy the EIPService interface, the vm_adapters public-IP resolver asserts the ctx-signed AssociatedPublicIPForInstance, and the default-subnet mapping test threads ctx into DescribeSubnets. |