mirror of
https://github.com/mulgadc/spinifex.git
synced 2026-10-15 17:11:30 +00:00
main
6 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
c81abd1836 | fix: add fipsboot guard to missing services | ||
|
|
6cf9ee9d03 |
fix(dhcp): retransmit within a DORA transaction, resolve the chaddr on every path, stop masking IPAM errors (#593)
* fix(dhcp): retransmit within a DORA transaction instead of restarting it nclient4's retryFn re-sends the same packet under the same xid with a doubling read deadline, which is RFC 2131 4.1 retransmission. WithRetry(1) runs that loop exactly once, so the client transmitted a single DISCOVER per attempt and never retransmitted it. socketTimeout then handed that lone transmission the caller's whole budget, so it sat silent for 4s, then 8s, then 16s, then 32s. Manager does retry, on that schedule, but each attempt builds a fresh client and therefore a fresh xid. Every attempt is a new transaction rather than a retransmission of the previous one, so an OFFER answering an earlier exchange is discarded as belonging to an unknown transaction. Send six transmissions per exchange starting from a 1s read, spanning a 63s ladder — longer than the widest window Manager schedules, so an attempt ends on the caller's context rather than on an exhausted ladder. socketTimeout now clamps to the caller's remaining budget instead of consuming it in one silent read. Observed live recovering an exchange whose OFFER arrived on the third transmission, which a single-shot client would have missed. Both allocation sites also stop replacing the allocator's error with a bare InsufficientAddressCapacity. ResolveErrorCode unwraps, so a genuinely exhausted static pool still surfaces that code while a DHCP fault reports as itself. The flat mapping is why every failure on this path read as a capacity problem regardless of cause. * chore(dhcptest): add --broadcast so the probe can mirror vpcd's Acquire path * fix(dhcp): resolve the chaddr on renew and release, not just on acquire Acquire derived a chaddr when the request carried none. Renew and Release read lease.HWAddr straight out of the store and handed it to nclient4, so a lease persisted before the chaddr was carried renewed with all zeros in chaddr and option 61 fell back to its untyped form. The lease then lands upstream with no hardware address against it — the outcome option 61 was fixed to stop, reached by a different route — and because the server sees an unknown client each time, every renewal takes a new lease. resolveHWAddr now serves all three paths and treats all-zeros as unusable rather than merely empty: six zero bytes passes a width check yet is the exact value that produces the unattributable entry. * test(dhcp): cover chaddr resolution and the unmasked allocation errors |
||
|
|
291e550e8a |
fix(dhcp): honour the caller's retransmission budget and encode option 61 correctly (#565)
* fix(dhcp): derive nclient4 read deadline from the caller's context
nclient4 races its own read deadline against the caller's context and the
shorter one ends the attempt. Acquire and Renew passed a fixed 5s, so every
window in Manager's 4s/8s/16s/32s retransmission schedule past the first was
truncated to 5s: the client listened for ~19s of its 90s budget and a server
that went quiet for longer was never waited out.
Measured in the sink, the split was total — attempt 1 (jittered under 5s)
always failed with the caller's context deadline, attempts 2 to 4 always
failed with nclient4's ErrNoResponse — and only 27% of clients that lost
attempt 1 were rescued by attempt 2.
Track the context's remaining time instead, keeping the configured value as
the fallback its doc comment already describes.
* fix(dhcp): keep the socket deadline strictly behind the caller's
Setting the nclient4 read deadline to exactly the context's remaining time
makes the two expire together, so a timed-out attempt reports either
context.DeadlineExceeded or nclient4's ErrNoResponse depending on which
goroutine wins. Observed live on a settled bridge: three attempts reported the
context deadline and the fourth reported ErrNoResponse, which reads as a
packet-matching fault rather than the plain timeout it is.
Give the socket a second of grace so ctx.Done() is always what fires.
* fix(dhcp): encode option 61 with its hardware-type byte
The client identifier was sent as a bare string, so the server read the
identifier's first character as the hardware type — "dhcp-gw-lrp-vpc-x"
arrived as type 100 ('d') with the identifier truncated. Since that is not
Ethernet, the server recorded no hardware address, and the upstream lease
table listed our leases with a MAC of all zeroes.
Send the chaddr typed as Ethernet, falling back to a type-0 identifier when
no hardware address is available. RELEASE now encodes identically, since the
server matches a release to a lease by client identifier.
Option 61 no longer carries the readable id, so restore it via hostname and
vendor class, which were specified but never populated. dhcptest builds its
options through the same helper rather than its own copy, which had drifted
into reproducing the broken encoding.
* fix(dhcptest): derive the probe MAC the way vpcd does
The probe carried its own copy of the MAC derivation, still on the 24-bit
02:00:00:xx:xx:xx hash that vpcd moved off when widening it to a SHA-256
prefix. So --spinifex-id leased under a MAC the daemon would never use:
"gateway-wan1" resolved to 02:00:00:7c:b7:b6 here and 02:54:df:71:22:5c in
vpcd, which makes the probe unable to reproduce a daemon lease at all.
Call DeriveMAC instead and drop the local copy.
|
||
|
|
b5198d55e2 | chore: enable depguard to block log | ||
|
|
fd3dc6b680 |
feat(network): ADR-0006 layer redesign + IPsec/OVN hardening (#255)
* refactor(vpcd): remove macvlan bridge mode
Macvlan was a single-NIC SSH-safe hack that predated veth mode and was
never selected by any active config path. Deletion is Phase 0 item 1 of
the network layer redesign (mulga-siv-125.1).
Removed:
- BridgeModeMacvlan const + setMacvlanMAC + ifaceIsMacvlan probe
- Macvlan MAC alignment block in launchService (only fired on dead path)
- Macvlan branch in detectBridgeMode + matching tests
- Macvlan duplicates of IGW/AddNAT centralized-NAT tests (veth versions
already cover the same path)
- --macvlan flag + macvlan case branch in setup-ovn.sh
Refactored:
- useCentralizedNAT() now == BridgeModeVeth (was != BridgeModeDirect);
verifyBridgeMode already rejects empty/unknown at startup
- Three IGW-pool tests now explicitly WithBridgeMode(BridgeModeVeth)
(previously relied on empty-mode defaulting to centralized)
Kept intentionally:
- Deprecation notes in docs/compute/vpc-networking/README.md
- Legacy macvlan-interface cleanup in reset-dev-env.sh + ansible
teardown role (migration for operator systems with stale spx-ext-*
interfaces from pre-veth installs)
* feat(vpcd): resolve external CIDR at startup with bounded retry
Block service start until the WAN bridge has an IPv4 address, with a 30s
retry window. Phase 0 item 2 of the network layer redesign
(mulga-siv-125.1). Guards the boot race where vpcd starts before
systemd-networkd finishes DHCP on br-wan, or before netplan applies a
static config.
Skipped when ExternalMode is empty (overlay-only deployments).
Forward-compatible with ADR-0006: the new resolveExternalCIDR /
externalCIDRFromBridge helpers become the backing implementation of
HostWiring.ExternalCIDR() once the network/host package lands in Phase 1.
Until then the resolved value is only used to fail-start on missing
uplink.
* fix(vpcd): cover external CIDR startup paths
Extract launchService's CIDR-resolve block to ensureExternalCIDRReady
helper so it's unit-testable, and add direct tests for
externalCIDRFromBridge (loopback + unknown-interface) to exercise the
original literal body. Closes the diff-coverage gap on Phase 0 commit
15b564d which left these paths unreachable from unit tests.
* refactor(network/ovn): extract L1 OVN client to network/ovn package
Move OVNClient interface, LiveOVNClient, ACLSpec, ErrNATNotFound and
namedUUID helper from services/vpcd to a new spinifex/network/ovn
package. The mock relocates to spinifex/network/ovn/mock as a
sub-package. Storage fields on the mock become exported so vpcd tests
can continue to seed/inspect state across the new package boundary.
services/vpcd retains thin type-alias and var-alias shims so existing
callers compile unchanged; Phase 2 removes those shims as vpcd is torn
down.
Adds -coverpkg=./spinifex/... to test-cover so cross-package test
exercise of mock methods continues to count toward coverage now that
the mock lives outside vpcd.
First sub-step of Phase 1 of docs/development/feature/spinifex-network-redesign.md
(bead mulga-siv-125.2). Pure refactor; no functional change. All
existing tests pass; preflight green.
* feat(network/topology): TopologyManager interface + vpcd adapter
Add spinifex/network/topology with Manager interface, VPC/Subnet/Port
specs, and OVN object naming helpers covering the L2 stable contract
(§7 of the redesign plan). Phase 1 keeps existing in-tree OVN names
(rtr-, ext-port-, sg_) and notes the §7.3 targets for a later
reconciliation migration.
TopologyHandler in services/vpcd grows EnsureVPC / DeleteVPC /
EnsureSubnet / DeleteSubnet / EnsurePort / DeletePort /
SetPortSecurityGroups methods that mirror the corresponding NATS
handlers' OVN ops with Spec inputs instead of nats.Msg envelopes,
satisfying topology.Manager via a compile-time check. Existing handlers
are unchanged; the duplication is short-lived (Phase 2 collapses them).
Smoke tests in topology_manager_test.go cover the idempotent create
path, delete cascade, and declarative SG membership move. Deliverable:
TopologyManager.EnsureVPC/Subnet/Port callable; all existing tests
green.
Second sub-step of Phase 1 of docs/development/feature/spinifex-network-redesign.md
(bead mulga-siv-125.2).
* feat(network/host): L0 HostWiring interface + physical/veth impls
Phase 1 deliverable for mulga-siv-125.2. Introduces network/host (L0 of
ADR-0006): UplinkMode enum, Wiring interface, and Physical/Veth
implementations with injectable Runner + InterfaceReader for testability.
Not yet wired into daemon/vpcd — Phase 2 replaces daemon.SetupComputeNode
and vpcd's resolveExternalCIDR with calls through this package.
* feat(network/policy): L3 SecurityGroup/NAT/Route managers
Introduce network/policy as the data-plane policy layer (ADR-0006 L3).
Three managers, all backed by network/ovn:
- SecurityGroupManager: clear+add ACL replacement on an existing port
group; port group lifecycle stays with L2 (topology.Manager).
- NATManager: bound to one NATMode at construction (derived from
host.UplinkMode). Distributed sets logical_port/external_mac on EIP
dnat_and_snat rules; centralised leaves them unset. Per-EIP, NAT GW,
and IGW-default SNAT entrypoints; all deletes idempotent.
- RouteManager: AddStaticRoute is read-then-decide so retries no longer
duplicate rows (closing the long-standing non-idempotency bug in
vpcd/topology.go's IGW default-route path).
ACL priority constants and infrastructure ACL builders move from
vpcd/{security,acl}.go into policy/acl.go with their semantics preserved
(default-deny 900/800 logged, DHCP-allow 1050, tenant 1000). No vpcd
wiring changes here — additive only; the reconciler (bead .3.2) and
network/external (bead .3.4) will consume these managers.
bead: mulga-siv-125.3.1
* feat(network/external): L5 IGW/EIP/NATGW managers
Pure additive — new package, no topology.Manager changes, no rewiring of
existing vpcd handlers. IGWManager builds the external switch + localnet +
gateway LRP + default route + chassis HA, with a flows barrier callers can
inject (production: ovn-nbctl --wait=hv sync). EIP/NATGW are thin L5
wrappers over policy.NATManager. GatewayIPAllocator interface lets the
DHCP-backed allocator stay in vpcd until the DHCP-mgr removal bead lands;
LinkLocalAllocator + StaticRangeAllocator ship here.
* feat(network/reconcile): L6 intent-actual reconciler replaces 5-pass startup
Build spinifex/spinifex/network/reconcile/ package per Phase 2.2 of the
network layer redesign. Reads desired state from NATS KV filtered by
vpc.AZ (with legacy empty-AZ matches-all rule), scans actual state from
OVN NB DB, diffs and applies with VPC → Subnet → Port → SG → IGW →
EIP/NATGW topological ordering.
Atomic port-group join via CreateLogicalSwitchPortInGroups closes the
racy gap the legacy scanENIPortMembership pass used to revive 30s later.
A 5-minute drift goroutine (leader-gated via JetStream KV CAS) replaces
the old 30s ReconcileSGsLoop.
Adds AZ field to VPCRecord stamped at create time. Empty AZ on pre-Phase
2.2 records matches every local AZ, so no migration pass is required.
Replaces and removes the 5-pass startup sequence in services/vpcd:
- Reconcile + ReconcileFromKV
- ReconcileSGsOnce + ReconcileSGsLoop
- RetrofitAllExternalLocalnetOptions
- RetrofitAllGatewayPortNetworks
IGW fresh-create continues to flow through the legacy NATS handler path
(handleIGWAttach) so the dhcpManager wiring stays intact until Phase
2.3; the reconciler only rebinds gateway-chassis on existing IGW
topology.
Closes mulga-siv-125.3.2.
* refactor(network/topology): promote live Manager impl to network/topology
Move the topology.Manager implementation out of services/vpcd/topology_manager.go
into network/topology/manager_live.go as a standalone liveManager constructed
via NewLiveManager(ovn.Client, opts...). Inputs that varied per-handler
(DNS server resolution from the external pool) are now passed as functional
options (WithDNSServer).
TopologyHandler still satisfies topology.Manager but its methods delegate
to a cached liveManager. The shim stays until the rest of mulga-siv-129
routes NATS subscribers through topology.Manager directly.
Also exports SubnetGatewayCIDR + FormatDNSServerList from network/topology
so the reconciler in network/reconcile can share helpers with the live
manager (audit pass to follow per plan §6).
Test cases ported one-for-one from services/vpcd/topology_manager_test.go
to network/topology/manager_live_test.go; the vpcd-side test file is
deleted. New WithDNSServer test asserts the option propagates into
DHCPOptions rows.
Refs mulga-siv-129 (Phase 2.6 vpcd subscriber migration, Slice 1 of N).
* refactor(vpcd): collapse SG subscribers onto network/{topology,policy} managers
Phase 2.6 / mulga-siv-129 slice 2. Rewrites the vpc.create-sg /
vpc.update-sg / vpc.delete-sg NATS subscribers in services/vpcd as
thin wrappers over topology.Manager (port group lifecycle) and
policy.SecurityGroupManager (ACL programming). Deletes the ~1000
lines of duplicated ACL builder and provisioning logic — its
authoritative copy lives in network/policy.
Surface additions:
- ovn.ErrPortGroupNotFound sentinel; mock + live GetPortGroup wrap
not-found via fmt.Errorf("%w: ...") so callers can use errors.Is.
- topology.Manager grows EnsureSGPortGroup / DeleteSGPortGroup
(resolves the apply.go TODO from §2.1 of the redesign plan).
liveManager implements them with GetPortGroup-then-Create /
GetPortGroup-then-Clear+Delete idempotency.
Behaviour delta: the old provisionSG rolled back the OVN port group
on AddACLs failure ("all-or-nothing"). The new path lets the port
group survive and relies on network/reconcile to retry EnsureSG on
its next sweep. The all-or-nothing fail-fast test cases are dropped;
ACL emission semantics are covered by network/policy/sg_test.go.
* refactor(vpcd): migrate VPC/Subnet/ENI subscribers to topology.Manager
Phase 2.6 / mulga-siv-129 slice 3. Rewrites vpc.create / vpc.delete /
vpc.create-subnet / vpc.delete-subnet / vpc.create-port /
vpc.delete-port / vpc.update-port-sgs NATS subscribers as thin
wrappers (≤30 lines each) over topology.Manager. Subscriber bodies
now: parse event → translate to spec → delegate to manager.
Deletes:
- vpcd.subnetGateway (and helpers_test.go + topology_test.go's
TestSubnetGateway block); parity coverage lives in
network/topology.TestSubnetGatewayCIDR.
- vpcd.reconcilePortSGs (the live manager already exposes the same
diff-then-transact via reconcilePortSGs on the L2 side).
- vpcd.TopologyHandler.dnsServer; lmDNSServer (passed via
topology.WithDNSServer to the live manager) is the live path.
Behaviour delta: handlers now strict-parse PrivateIpAddress /
MacAddress / CidrBlock at the NATS boundary and reject malformed
payloads instead of degrading to "no DHCP options". The reconciler
guarantees that field validity is upheld upstream of the publish.
* refactor(network/reconcile): drive SG port groups via topology.Manager
applySGs now calls topology.Manager.EnsureSGPortGroup /
DeleteSGPortGroupByName instead of reaching directly into the OVN client.
Reconcile.Config gains a Topology field (required); the production caller
in services/vpcd passes the TopologyHandler shim, the reconcile package
tests construct a fresh topology.NewLiveManager bound to the mock OVN
client.
DeleteSGPortGroupByName is added to the topology.Manager interface for the
reconciler's orphan-removal path, which iterates raw OVN port-group names
without a groupID round-trip. The existing DeleteSGPortGroup(groupID)
delegates to it.
Resolves the TODO at apply.go:137 carried over from slice 2 of
mulga-siv-129.
* feat(network/policy): add FlowsBarrier option to NATManager
NATManager.AddEIP needs to block on `ovn-nbctl --wait=hv sync` after
writing the dnat_and_snat row so the NATS reply only returns once every
chassis has the rewrite flow. The legacy vpc.add-nat handler does this at
the tail of handleAddNAT; the manager has lacked it since slice 2.1.
NewNATManager grows a functional-options tail (Option / WithFlowsBarrier).
Defaults to a no-op for tests; production wiring in services/vpcd passes
waitForFlowsHV. AddEIP now invokes the barrier after AddNAT, logging at
warn level on failure to match the legacy handler's _ = waitForFlowsHV()
swallowing semantics.
Pre-work for slice 4 of mulga-siv-129 — without the barrier the NAT EIP
subscriber migration would lose the post-write flow-install gate.
* refactor(vpcd): migrate NAT GW subscribers to policy.NATManager
handleAddNATGateway / handleDeleteNATGateway now decode the NATS event
and delegate to policy.NATManager.{AddNATGateway,DeleteNATGateway}. The
manager carries identical OVN logic — same snat type, same ExternalIDs
(spinifex:vpc_id + spinifex:nat_gateway_id) — so existing
TestTopologyHandler_AddNATGateway / DeleteNATGateway suites stay green.
Lazy-constructed NATManager added on TopologyHandler (natmOnce). Mode is
derived from the bridge mode (veth → centralized, direct → distributed)
and the FlowsBarrier is bound to waitForFlowsHV for parity with the
legacy EIP path's tail barrier (used by the next slice, vpc.add-nat).
Slice 4 of mulga-siv-129, sub-step b.
* refactor(vpcd): migrate EIP NAT subscribers to policy.NATManager
handleAddNAT / handleDeleteNAT now decode the NATS event and delegate to
policy.NATManager.{AddEIP,DeleteEIP}. The behavioural contract is
preserved end-to-end:
- Idempotency-skip on a matching dnat_and_snat row (same VPC + LogicalIP,
plus MAC + LogicalPort under distributed NAT) moves into AddEIP so
duplicate vpc.add-nat publishes never tear down the rule the previous
invocation just installed (mulga-siv-124).
- Stale-rule cleanup across every router stays in AddEIP.
- Post-write waitForFlowsHV barrier is now driven by the manager via the
FlowsBarrier option wired in services/vpcd (slice 4a).
- DeleteEIP returns nil on ErrNATNotFound, matching the handler's
fire-and-forget "already absent = success" semantic.
The vpcd "errors" import drops out with the inline error-comparison.
Slice 4 of mulga-siv-129, sub-step c.
* refactor(vpcd): migrate IGW subscribers to external.IGWManager (partial)
handleIGWAttach now branches at decode time:
- Centralised NAT + DHCP-sourced pool keeps using attachIGWLegacy because
the gateway-LRP IP comes from vpc.dhcp.acquire, and that DHCP client is
the vpcd-local manager that bead mulga-siv-125.3.3 will retire.
- All other shapes (distributed NAT, static-range pool, no pool)
delegate to external.IGWManager.AttachIGW. The manager mirrors every
step the legacy handler ran — external switch + localnet port +
gateway LRP + switch-side router peer + default route + chassis HA +
waitForFlowsHV tail barrier — so observable behaviour is unchanged.
handleIGWDetach drops its inline OVN walk entirely; both paths exit
through external.IGWManager.DetachIGW followed by releaseGatewayLRPLease.
The lease release stays in vpcd because the upstream client lives in
services/vpcd/dhcp; calling it after every detach is safe because the
upstream server expires unknown leases on its own.
Lazy-constructed IGWManager added on TopologyHandler (igwmOnce). Pool,
allocator (StaticRangeAllocator), chassis, NAT mode, NAT manager, route
manager, and FlowsBarrier are all derived from the existing
TopologyHandler state.
The DHCP-coupled legacy branch retains its full inline OVN logic; it
will disappear in slice-after-125.3.3 follow-on. Slice 4 of
mulga-siv-129, sub-step d.
* feat(ec2/instance): honor AssociatePublicIpAddress per-NIC override
RunInstances --network-interfaces "AssociatePublicIpAddress=true|false"
was silently ignored, only subnet.MapPublicIpOnLaunch gated public IP
assignment. AWS contract is per-NIC override wins.
Extend TestPrepareRunInstances_PublicIPAutoAssigned to table-driven
3 cases: subnet true no-override, subnet false override true, subnet
true override false.
* refactor(config): drop upstream-DHCP config surface (static WAN pool only)
Hard-error in LoadConfig on legacy keys: [network] external_dhcp,
[nodes.<n>.vpcd] dhcp_bind_bridge, and [[network.external_pools]]
source = "dhcp". Add pool range validation (must fit inside the
gateway/prefix_len CIDR; per-cluster non-overlap).
Strip ExternalDHCP from config.NetworkConfig + formation.NetworkConfig
+ admin.ConfigSettings, and DhcpBindBridge from config.VPCDConfig +
admin.ConfigSettings + vpcd.Config. vpcd.ExternalPoolConfig.IsDHCP()
short-circuits to false; the field and downstream DHCP branches in
external_ipam / topology.go remain for Slice C to delete together with
dhcp_manager.
cmd/spinifex/cmd/admin.go: drop useExternalDHCP path and the
detectedDhcpBindBridge helper; require --external-pool when
--external-mode=pool; auto-detect default no longer infers source=dhcp.
service.go's wan_bridge legacy-key rejection now advises removing the
key entirely (vpcd auto-detects br-wan), not renaming to
dhcp_bind_bridge.
Two topology_test cases that exercise the DHCP gateway-LRP path are
skipped — Slice C deletes attachIGWLegacy and these tests together.
* refactor(vpcd): delete dhcp_manager + DHCP gateway-LRP path (Slice C)
Removes upstream-DHCP-client gateway-LRP allocation in favor of static
WAN-pool allocation (StaticRangeAllocator). Part of bead mulga-siv-125.3.3.
- delete services/vpcd/dhcp_manager.go + dhcp/ subpackage (~865 lines)
- delete allocateGatewayLRPIPViaDHCP + releaseGatewayLRPLease paths
- drop ExternalPoolConfig.Source + DhcpBindBridge + IsDHCP() fields
- drop ExternalIPAllocation lease fields (Expiry/ServerID/HWAddr) and
ExternalIPAMRecord.Source
- drop NewExternalIPAM nc *nats.Conn argument; update all 4 call sites
- rename verifyBridgeMode local dhcpBindBridge -> wanBridge; update error
strings and tests
Slice D (delete attachIGWLegacy + dispatcher) intentionally deferred.
* refactor(vpcd): delete attachIGWLegacy + IsDHCP stub (Slice D)
Closes mulga-siv-129 slice 4d. Part of bead mulga-siv-125.3.3.
handleIGWAttach now unconditionally delegates to external.IGWManager.
attachIGWLegacy (~207 lines, ~5 OVN write steps + chassis scheduling)
deleted along with its dispatcher branch in handleIGWAttach. The
ExternalPoolConfig.IsDHCP() dead stub is gone.
No code paths or NATS subjects regress: the static-pool / distributed
branches were already going through external.IGWManager since Slice 4d
(6719dc3).
* feat(ipam): Purpose field on every IPAM record (Slice B)
Part of bead mulga-siv-125.3.3.
Adds a Purpose enum (handlers/ec2/vpc/purpose.go) tagging every IP
allocation with its semantic role (eni-primary, eni-public, eip,
igw-lrp, natgw-external, …) so multi-VPC clusters can reclaim/audit
by (owner, purpose).
External IPAM (spinifex-external-ipam, v1→v2):
- ExternalIPAllocation.Type → .Purpose; legacy values mapped via
LegacyExternalTypeToPurpose (gateway→igw-lrp, auto_assign→eni-public,
elastic_ip→eip). Unknown legacy values warn and become "unknown".
- AllocateIP / AllocateFromPool / allocateFromPool param rename
allocType→purpose. All call sites pass Purpose* constants.
- migrate/002_external_ipam_purpose.go: idempotent CAS-retry migration
with v1/v2-union record shape so partial migrations resume cleanly.
Internal IPAM (spinifex-vpc-ipam, v1→v2):
- IPAMRecord.Allocated []string → []IPEntry{IP, Purpose, OwnerID}.
- AllocateIP gains purpose+ownerID args; ReleaseIP unchanged (still
keyed on IP).
- AllocatedIPs returns []IPEntry.
- eni.go reorders eniId generation before AllocateIP so the owning
resource ID lands on the new entry.
- migrate/003_ipam_purpose.go: cross-bucket backfill that reads the
ENI bucket via the new RunKVWithJetStream path. Orphaned IPs
(no owning ENI) warn and become Purpose=unknown.
Migrate framework:
- KVContext gains an optional JetStream field; new
Registry.RunKVWithJetStream method threads it through. RunKV
signature unchanged — all other callers are unaffected.
Tests:
- ipam_test.go: AllocateIP signature updates; AllocatedIPs now asserts
IP / Purpose / OwnerID on the returned entries.
- external_ipam_test.go: replaces "auto_assign"/"elastic_ip" literals
with PurposeENIPublic/PurposeEIP and asserts alloc.Purpose.
- migrate/002 + 003 tests: schema-detect, idempotent rerun,
no-JetStream fallback, empty bucket.
* refactor(daemon): tombstone obsolete spinifex-dhcp-leases KV bucket
The dhcp_manager removed in Phase 2.3 (bead mulga-siv-125.3.3) owned the
spinifex-dhcp-leases KV bucket. The migrate framework only handles
per-bucket schema version bumps, not bucket deletion, so the obsolete
bucket would linger on upgraded clusters.
Add a one-shot tombstone after initJetStream that deletes the bucket if
present. DeleteKVBucketIfExists treats ErrBucketNotFound and
ErrStreamNotFound as success, so the call is idempotent across restarts.
* feat(config): add network.ipsec_enabled cluster flag (default true)
Add IPSecEnabled to NetworkConfig in both the cluster TOML schema and
the formation handshake payload. Default true so AWS-parity intra-AZ
encryption is on by default. Operators can flip false in
[network] for trusted single-rack lab topologies.
Phase 2.5 (bead mulga-siv-125.3.5) consumes the flag from admin init
(strongSwan provisioning), formation server (propagates to joiners),
and daemon startup (ovs-vsctl ipsec_encapsulation toggle).
* feat(admin): IPsec peer cert generator signed by cluster CA
Add GenerateIPSecPeerCert + IPSecCertPaths in spinifex/admin so admin
init (and the future admin add-node path) can issue per-node IKEv2 peer
credentials signed by the existing cluster CA. The cert carries
id-kp-ipsecIKE (RFC 4945) so strongSwan accepts it as an IKEv2 peer
credential when ovs-monitor-ipsec materialises tunnel configs.
Cluster CA is reused directly — no intermediate strongSwan PKI today;
when intermediate CAs land that becomes a separate workstream.
The cert/key pair lives under {configDir}/ipsec/peer.{pem,key}; the
daemon points OVS Open_vSwitch.other_config (certificate, private_key,
ca_cert) at these paths when network.ipsec_enabled is true.
* feat(admin): wire IPsec peer cert into admin init + join paths
Add --ipsec bool flag (default true) on adminInitCmd. Single-node init
and the multi-node leader path both emit an IPsec peer cert after the
existing CA+server-cert generation. The multi-node formation server
propagates the IPSecEnabled flag to joining nodes via NetworkConfig;
admin join honours it and emits its own peer cert during the same
cert-issuance step that already produces the server cert.
spinifex.toml template gains an unconditional [network] block carrying
ipsec_enabled so the value is visible to operators on every install
regardless of whether external networking is configured. The daemon
reads it via cluster config (NetworkConfig.IPSecEnabled).
Bead mulga-siv-125.3.5.
* build: install openvswitch-ipsec for OVN native IPsec
openvswitch-ipsec provides ovs-monitor-ipsec, which reads the
Open_vSwitch.other_config cert/key/CA pointers and materialises
strongSwan configs for every Geneve tunnel managed by ovn-controller.
Pulls in strongswan + strongswan-pki as transitive deps.
Required by bead mulga-siv-125.3.5.
* feat(daemon): enable OVN native IPsec on intra-AZ Geneve at startup
When network.ipsec_enabled is true (default), the daemon points the
local OVS DB other_config at the per-node IPsec peer cert that admin
init / admin join provisioned (configDir/ipsec/peer.{pem,key} + the
cluster CA at configDir/ca.pem), then sets
other_config:ipsec_encapsulation=true.
ovs-monitor-ipsec (shipped by the openvswitch-ipsec package) consumes
those pointers and materialises strongSwan configs for every Geneve
tunnel ovn-controller programs — including OVN-IC inter-AZ tunnels
when federation lands in Phase 3a.
Missing cert files log a warning and leave Geneve plaintext; operators
upgrading an older cluster reissue certs via spx admin to close the
gap.
Bead mulga-siv-125.3.5.
* test(e2e): multinode IPsec wiring + xfrm SAs + ESP capture
TestMultinodeIPSec asserts:
- OVS DB on every node carries certificate/private_key/ca_cert pointers
and other_config:ipsec_encapsulation=true (what daemon.enableOVNIPSec
writes).
- ip xfrm state on every node has at least one AEAD SA in AES-GCM mode
(rfc4106(gcm(aes)) or gcm(aes)) within 90s.
- tcpdump catches ESP (ip proto 50) on the underlay (best-effort —
logged only; geneve may be idle during the 5s capture window).
Skips cleanly when the cluster was bootstrapped with --ipsec=false
(no ipsec_encapsulation key on first node).
Read-only over SSH; runs in the parallel bucket alongside the other
non-mutating multinode tests.
* fix(igw): write attachment State="attached" for AWS parity
Reconciler intent loader (network/reconcile/intent.go::loadIGWs) filters
IGW records with `State == "attached"`, but AttachInternetGateway was
writing `State = "available"`. The reconciler therefore never picked up
any attached IGW — `intent_igws=0` on every pass — so the OVN external
switch + gateway LRP + WAN bridge wiring built by IGWManager.AttachIGW
never ran for default-VPC IGWs (whose live `vpc.igw-attach` publish at
daemon bootstrap is lost — vpcd subscriber not yet wired).
Net effect on single-node e2e: every SSH probe to 192.168.x public IPs
timed out (TestSSHProbe, TestModifyInstanceAttribute, TestRebootInstance,
TestNATGateway, TestSGToSGDatapath) because SNAT/DNAT rules on the VPC
router had no path to the external network.
Match AWS InternetGatewayAttachment.State semantics:
- Attach: State="attached"
- Detach: State="detached"
Detach value is internal — recordToEC2 gates Attachments on VpcId != "",
so the detached State is never surfaced to API consumers.
Bead: mulga-siv-131
* fix(reconcile): call AttachIGW when IGW topology missing
applyIGWs previously deferred to the NATS handler when an intent IGW
had no external switch in OVN. When the vpc.igw-attach event is lost
(bootstrap-time default-VPC IGW published before vpcd subscriber is
ready), deferral never resolves and VM public-IP traffic dies.
Call IGWManager.AttachIGW directly — it is idempotent (short-circuits
when the external switch already exists), so the reconciler converges
default-VPC IGWs on first pass without duplicating work on subsequent
passes.
Closes mulga-siv-132.
* fix(test): align NewExternalIPAM call with 2-arg signature
Rebase onto dev pulled in daemon_system_instance_test.go which used
the legacy 3-arg NewExternalIPAM(jsNC, js, pools). The feature branch
already narrowed the signature to (js, pools) via the upstream-DHCP
config drop; align the test with the current signature.
* fix(vpcd): EnsureSubnet must EnsureVPC first to avoid NATS race
vpc.create-vpc and vpc.create-subnet are independent NATS events with
no inter-event ordering guarantee. Tenant bootstrap on iam.account.created
publishes both within <1ms, so the subnet handler's
CreateLogicalRouterPort can race the parent VPC's CreateLogicalRouter and
fail with "logical router not found". The cascade fails CreateNetworkInterface
which fails RunInstances which surfaces as InsufficientInstanceCapacity to
the SDK — masking the underlying topology race.
handleSubnetCreate now calls EnsureVPC(VPCID-only) before EnsureSubnet.
EnsureVPC short-circuits on existing LR (idempotent), so the race-winning
vpc.create-vpc handler's full CIDR/VNI ExternalIDs are preserved; if subnet
wins the race the LR is created with bare ExternalIDs (cosmetic) and the
follow-on vpc.create-vpc short-circuits.
Adds TestIntegration_SubnetBeforeVPC regression covering both orderings.
Closes mulga-siv-133.
* feat(ansible): require --external-pool, drop NAT, forward EXTRA_VARS
spx admin init now rejects --external-mode=nat and demands --external-pool
when mode=pool. The ansible init role silently skipped pool flags when the
range was unset, so installs fell over inside the spx validator. Make
targets also swallowed `-e` (make's env-override flag), so operators could
not override pool start/end without editing defaults.yml.
- vars/defaults.yml: rename nat_gateway_ip → external_gateway_ip; add
spinifex_external_no_external opt-out; document the spx flag contract.
- roles/init/tasks/main.yml: drop NAT branch; assert pool range upfront
with a fail_msg pointing at EXTRA_VARS / defaults.yml; emit gateway,
prefix-len, gateway-ip only when explicitly set (let spx auto-detect);
honour --no-external.
- playbooks/dev-reset.yml: rename captured var; coerce legacy
external_mode=nat to pool with a warn; tighten gateway regex with \b.
- Makefile: ansible-dev-* targets now forward EXTRA_VARS="key=val ..."
through --extra-vars so `make` callers can override without editing
defaults.yml.
- scripts/ansible/README.md: document pool requirement, both invocation
styles (direct -e vs make EXTRA_VARS), NAT removal.
* fix(ipsec): guard ipsec_encapsulation on ovs-monitor-ipsec liveness
enableOVNIPSec set OVS cert pointers + ipsec_encapsulation=true without
ensuring ovs-monitor-ipsec.service was running. Without that daemon, OVS
holds the cert pointers unused, strongSwan never gets IKE config, and
tunnel traffic ovn-controller marks for encryption gets silently
dropped. TestMultinodeIPSec fails on `node1 xfrm has no AEAD SAs`.
- systemd: spinifex-daemon Wants=/After= ovs-monitor-ipsec.service
- daemon: ensureOVSMonitorIPSecActive — systemctl enable --now +
is-active poll; refuses to flip ipsec_encapsulation if daemon is dead
- daemon: single-node short-circuit — no peers means no tunnels means
the flag is at best inert and at worst load-bearing-silent-drop
- ci: capture-net-diag.sh + workflow steps to snapshot OVS/OVN/xfrm
state on failure, fan out across all 3 multinode nodes
Refs: mulga-siv-136
* test(e2e): sticky-skip downstream SSH tests when probe fails
When TestSSHProbe times out (3 min, typically because of mulga-siv-134
datapath bug), four downstream tests each re-probe SSH on the same
broken datapath and time out identically — single-node job runs ~24 min
instead of ~12 min, with the same error logged five times.
First waitForSSHReady timeout now sets a package-level atomic flag;
subsequent waitForSSHReady / trySSHReady / requireSSHHealthy calls skip
immediately. Preserves the original red signal on TestSSHProbe and on
any test that genuinely needed SSH (Skip ≠ Pass). Bool variant
(trySSHReady) consults but does not set the flag — its caller already
treats False as advisory warning, not fatal.
TestSGToSGDatapath has its own EventuallyErr SSH wait (not via
waitForSSHReady) and needs an explicit requireSSHHealthy(t) gate at
the top of runSGToSGDatapath. TestNATGateway already calls
waitForSSHReady first so the gate fires naturally.
Refs: mulga-siv-137
* fix(ipsec): use Debian unit name openvswitch-ipsec.service
CI artifact shows `Unit ovs-monitor-ipsec.service could not be found`
on every node. Debian's openvswitch-ipsec package ships the unit as
openvswitch-ipsec.service (the binary inside is ovs-monitor-ipsec, but
systemd's name follows the package). The previous commit guarded on
the wrong unit name, so:
- spinifex-daemon.service Wants=/After= silently no-op'd (missing unit)
- enableOVNIPSec's `systemctl enable --now ovs-monitor-ipsec.service`
failed, daemon logged a warning and continued without flipping
ipsec_encapsulation=true
- TestMultinodeIPSec skipped with `node1 reports ""` because OVS DB
never received the cert pointers
Rename across all 5 spots (daemon, systemd unit, test, CI diag script,
workflow journal capture) to match the Debian package layout.
Note: the package itself still must be present on the CI VM image —
that's tracked in the mulga repo (image-builder provision.sh +
bootstrap-install.sh shim).
Refs: mulga-siv-136
* fix(e2e): authorize default SG tcp/22 + icmp in single-node fixture
admin init leaves the default SG closed (AWS parity); the Go single suite
never ported the Phase-5 SG-ingress block that run-e2e.sh has had since day
one, so every test runner SSH/ping probe hits the OVN port-group ACL drop.
- ec2helpers: add AuthorizeICMPIngress + EnsureDefaultSGOpen helpers.
- single/main_test: open default SG once per process in pkgFixOnce.Do.
- witness: extend ensureDefaultSGSSHIngress to authorize ICMP too.
- run-e2e.sh: append matching ICMP authorize next to tcp/22 block.
mulga-siv-134
* fix(network/reconcile): key DHCP_Options lookup by subnet_id not CIDR
Multi-tenant default VPCs share the same subnet CIDR (172.31.0.0/20) per
account. The existing FindDHCPOptionsByCIDR gate at apply.go:107 found
the first account's DHCP_Options row and skipped creation for every
subsequent subnet with the same CIDR. Those subnets' ports then attached
nothing (FindDHCPOptionsByExternalID misses on subnet_id), VMs got no
DHCPv4 lease, and SSH/ICMP into them silently failed even though SG
ACLs and NAT were correct.
Switch the gate to FindDHCPOptionsByExternalID keyed on spinifex:subnet_id
so each subnet owns its own row, matching the attach lookup at line 203.
Verified: account 000000000001 default VPC RunInstances now produces an
LSP with dhcpv4_options populated, VM cloud-init reports a 172.31.0.5/20
lease + default route via 172.31.0.1, and ping + ssh TCP handshake to
the EIP succeed end-to-end. Stale DHCP_Options row for the prior dead
subnet was wiped manually; reconciler recreated the correct row for the
live subnet on its next pass.
* fix(ipsec): enable openvswitch-ipsec at provision time, drop daemon write
Provisioning now runs `systemctl enable --now openvswitch-ipsec.service`
alongside openvswitch-switch and ovn-controller. The spinifex-daemon
process drops its `enable --now` shell-out and only polls is-active.
Sudoers gains one read-only line:
spinifex-daemon ALL=(root) NOPASSWD: /usr/bin/systemctl is-active openvswitch-ipsec.service
This mirrors the existing vpcd ovn-controller is-active precedent and
removes the daemon's need for systemd-write capability. Aligns with
least-privilege service account pattern: provision enables services,
daemon only reads status.
If the unit is inactive at runtime, the daemon refuses to flip
ipsec_encapsulation=true (silent-drop guard from mulga-siv-136) and
surfaces a clear error pointing at scripts/setup-ovn.sh.
* chore: unblock preflight on feat/network-layer-redesign
Two pre-existing failures blocked preflight on the branch:
- govulncheck flagged golang.org/x/net@v0.54.0 (GO-2026-5026, ASCII Punycode
rejection bug in idna.ToASCII); reached via utils.DownloadFileWithProgress.
Bump to v0.55.0; go mod tidy carries x/sys to v0.45.0.
- TestTopologyHandler_SubnetCreate_RouterPortFails asserted subnet create
fails when the parent VPC router is missing. That contract changed in
|
||
|
|
28ca689130 |
feat: VFIO GPU passthrough (#188)
* feat: add GPU discovery package (mulga-992) Adds spinifex/gpu package with sysfs-based GPU enumeration, IOMMU group member lookup, and a PCI device ID model table. Vendor-specific enrichment via nvidia-smi is attempted opportunistically and falls back to the built-in table when unavailable. All discovery and IOMMU logic is covered by unit tests using mock sysfs trees. * feat: add VFIO bind/unbind and GPU pool manager (mulga-993) Adds gpu.BindVFIO/UnbindVFIO using sysfs driver_override for per-device driver switching, and gpu.Manager which owns the claim/release lifecycle for the GPU pool including full IOMMU group binding, rollback on partial failure, and marking entries unavailable when rebind fails after VM termination. * feat: add G5 instance type generator with GPU model support (mulga-994) - Add GPUModel type, NVIDIAa10g constant, and GPUModelForVendorDevice lookup - Add generateGPUTypes to emit g5.* types with GpuInfo populated - Add IsGPUType helper for consumers filtering GPU-capable types - Update DetectAndGenerate to accept gpuModels []GPUModel parameter * feat: integrate GPU passthrough into daemon lifecycle (mulga-995) - Add gpu_passthrough config flag; discover GPUs and build manager at startup - Gate g5 instance types on GPU pool availability via canAllocateCount - Claim GPU (VFIO bind) in LaunchInstance; inject vfio-pci QEMU device - Release GPU (VFIO unbind, rebind to host driver) in stopInstance - Re-claim GPU on daemon restart when QEMU process is still alive - Add UseUEFI / OVMF support for x86_64 VMs (optional, falls back to SeaBIOS) - Fix Claim to use stored OriginalDriver when device is already vfio-pci bound * feat: add GPU fields to NodeStatus and spx top nodes (mulga-996) - Add TotalGPUs/AllocGPUs to NodeStatusResponse (zero on non-GPU nodes) - Populate from gpuManager in handleNodeStatus - Show GPU (used/total) column in spx top nodes; "-" when no GPUs present * feat: Ubuntu 24.04 GPU AMI build pipeline (mulga-997) Extends build-system-image.sh to support Ubuntu alongside Alpine. Key differences handled: partition table (parted resizepart p1), bind mounts for DKMS (/proc /sys /dev), apt vs apk, systemctl vs rc-update. DISTRO defaults to "alpine" for backward compatibility. Adds ubuntu-gpu.conf manifest and ubuntu-gpu-setup.sh chroot script that installs nvidia-headless-550-server with DKMS pre-built against a pinned linux-image-generic kernel, blacklists nouveau, and prevents unattended-upgrades from invalidating the pre-built module. * Fixed GPU passthrough and added test script * feat: always-probe GPU at startup, surface capability in NodeStatusResponse - Add gpuProbeResult struct and probeGPU() which runs at daemon startup regardless of gpu_passthrough config. Checks sysfs for GPUs, IOMMU groups, and vfio_pci module presence. - Store gpuProbe on Daemon struct; split NewDaemon into probe (always) and activate (opt-in) phases. - Populate GPUCapable, GPUPassthrough, GPUModels on NodeStatusResponse so operators can see hardware state before enabling passthrough. - Update 'spx top' GPU column: '-' = no hardware, '0/N*' = capable but passthrough not active, 'used/total' = passthrough active. * feat: SIGHUP hot-reload for GPU passthrough config (mulga-1001) - Export GenerateGPUTypes for use by the reload path - Add ResourceManager.reloadGPUTypes: mutates instanceTypes map in-place (preserves references held by instanceService) and updates NATS subscriptions without full daemon restart - Separate SIGHUP from SIGTERM/SIGINT: setupReload() listens for SIGHUP in a context-aware loop; setupShutdown no longer intercepts SIGHUP - Add reloadConfig() + applyGPUConfig(): re-reads spinifex.toml on signal, handles false→true (re-probe + activate) and true→false (refuse if instances running, otherwise deactivate) transitions * feat: spx admin gpu status/enable/disable commands (mulga-1000) - admin.SetGPUPassthrough: Go implementation of the idempotent TOML write (replaces the inline Python heredoc in spx-test-gpu.sh) - spx admin gpu status: shows GPU hardware, IOMMU/vfio state, passthrough activation, and advertised g5 instance types via NATS NodeStatusResponse - spx admin gpu enable: checks prerequisites, writes TOML, sends SIGHUP, polls until daemon confirms GPUPassthrough=true - spx admin gpu disable: refuses while GPU instances are running, otherwise writes TOML, sends SIGHUP, polls until confirmed - spx-test-gpu.sh: replace Python TOML heredoc with spx admin gpu enable * fixed admin * fix: filter Intel iGPU from passthrough pool, use lspci for consumer GPU names Discover() now skips non-NVIDIA/AMD vendors so Intel iGPUs never enter the passthrough pool. enrichFromLspci() uses the system PCI ID database via lspci -vmm to populate the model name for any card not in the hardcoded table, without needing nvidia-smi or driver tools. * fix: grant CAP_SYS_ADMIN and vfio device access to spinifex-daemon GPU passthrough requires writing to /sys/bus/pci/drivers/vfio-pci/unbind on instance stop. The kernel gates this on CAP_SYS_ADMIN regardless of file permissions. QEMU subprocesses also need char-vfio rw access to open /dev/vfio/N for the passed-through device. * fixing gpu bining permissions * working state of gpu passthrough on phyiscal box * installer grub image fixes * made gpu-passthrough more user facing * fixed banner * fixed banner * banner fix * gpu passthrough docs * preflight tweak * vpcd fixes to set br-wan to promisc for public IP DHCP processes * fixed vpcd br-wan promisc and veth pair * ssh keygen fix * fixes after running /review-branch * feat: re-wire GPU claim and device injection after vm.Manager refactor GPU passthrough claim (VFIO bind) and QEMU device injection were lost when dev's vm.Manager refactor (#185/#186) moved StartInstance/ CreateQMPClient into vm/lifecycle.go. Re-add both in their correct new homes: - daemon_handlers_instance.go: claim GPU before vmMgr.Run() in both RunInstances and StartStoppedInstance handlers; release on failure - vm/lifecycle.go startQEMU(): inject vfio-pci device with x-vga flag derived from instance.GPUXVGAEnabled when GPUPCIAddress is set * fix: Create spinifex user ~/.ssh and keys in firstboot --------- Co-authored-by: Ben Duncan <5178243+benduncan@users.noreply.github.com> Co-authored-by: Julian Sommer <115516918+juliansommer@users.noreply.github.com> |