Files
rustfs/.config
Zhengchao An b0b5ffb8e2 test(e2e): cluster harness drivesPerNode + 2-pool topology (backlog #1325) (#4937)
test(e2e): add drivesPerNode and 2-pool cluster harness topology (backlog #1325)

Extend the e2e cluster harness so tests can declare per-node multiple drives (drivesPerNode) and a two-pool topology, alongside a smoke suite that boots such a cluster and round-trips a PUT/GET.

A new `ClusterTopology` describes node_count, drives_per_node, and pool membership, and `RustFSTestClusterEnvironment::with_topology` builds the matching on-disk drive directories and `RUSTFS_VOLUMES` string. `new(node_count)` now delegates to a single-pool single-drive topology, so existing single-drive cluster tests are byte-for-byte unchanged. `ClusterNode` gains `data_dirs` (all drives, `data_dirs[0] == data_dir`) and `pool_idx`; multi-drive/multi-pool clusters automatically add `RUSTFS_UNSAFE_BYPASS_DISK_CHECK=true` because their drives share the same temp filesystem.

The `RUSTFS_VOLUMES` assembly matches the two forms the server parser accepts on a single localhost machine (verified against ecstore `DisksLayout::from_volumes`): a single pool is the explicit enumeration of every `(node, drive)` endpoint (no ellipses, one legacy DistErasure pool), while multiple pools each contribute one ellipses argument `http://<addr><node-base>/drive{0...N-1}`. A pool argument is a single URL template, so it cannot enumerate multiple distinct-port hosts; a pool striped across several localhost nodes would need a host ellipses that forces a shared on-disk path and collides physically. The topology validator therefore requires every pool in a multi-pool layout to own exactly one node and requires drives_per_node >= 2 (the parser rejects a single-drive `drive{0...0}` ellipses pool). Genuine multi-node pools need real multi-host infrastructure and are deferred to the nightly cluster lane (backlog #1313/#1314).

Unit tests assert the volumes-string layout for single-pool single-drive (backward compatible), single-pool multi-drive (8 explicit endpoints), and two-pool (one ellipses arg per pool), plus the validator rejections. The smoke suite `cluster_multidrive_pool_test` boots a 4-node x 2-drive single pool and a 2-node/2-pool cluster, asserts the volumes layout, and round-trips a PUT/GET using the harness readiness handshake (no fixed sleeps). It joins the six existing RustFSTestClusterEnvironment suites excluded from the merge-gate `e2e-full` profile so it runs in the nightly 4-node lane.

Network fault injection (toxiproxy / socket proxy) and 5GiB large-object budgets remain out of scope for this block.
2026-07-17 01:02:38 +00:00
..