Files
pulse/internal/hostagent
rcourtman f2b732721e Fix physical disks vanishing on wide nodes and standby-misreporting SSDs
Two root causes behind #1516's remaining reports:

- A node whose Proxmox disks/list query fails (PVE probes SMART per disk
  inside that call, so dozens of disks can exceed the API window) now
  falls back to the linked host agent's smartctl inventory instead of
  leaving the Physical Disks view empty. Each node also gets its own
  attempt window so one slow node no longer starves the rest of the
  cluster, and a poll that runs out of budget saves partial results.

- The -n standby probe guard is dropped for positively confirmed
  non-rotational devices in both the host agent and the node sensor
  wrapper. The guard exists to avoid spinning up sleeping HDDs; an SSD
  has nothing to spin up, and some SATA SSDs answer CHECK POWER MODE
  with a bogus standby state that permanently hid their temperature,
  attributes and history.

Refs #1516
2026-07-11 10:24:45 +01:00
..
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-07-11 10:11:35 +01:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-05-05 09:29:34 +01:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00
2026-03-18 16:06:30 +00:00