Files
pulse/docs/release-control
rcourtman e02edd9989 Show retained disk temperatures as last known in drawers and tables
Normalization keeps a disk's last temperature when the current
observation did not collect one, such as a disk in standby or a host
agent past its reporting lease. PR #2603 taught the Storage presenters
to show that value as last known. Four surfaces still read the raw
number as a current reading:

- The TrueNAS disk drawer's Temperature row took the 55C warning tone
  from a retained reading, and its summary listed it as a reading.
  The row now says "(last known)" with the reason as title and no
  tone. The summary drops it because it has no room for the reason.
- The drawer History fallback fed a retained reading into smart_temp
  and labelled it "current" when no points were stored. It now goes
  through the deferred-metric slot, so the legend says "last known" and
  the reason shows above the chart. The disk's value is read from
  physicalDisk beside its collection state, because websocket rows
  carry no top-level temperature for a disk and showed "-" instead.
- The TrueNAS storage table's Temp cell showed a retained reading
  plainly, and hottest-first sorted it to the top. It now renders muted
  with its reason, and the sort ranks it as no reading.
- The Proxmox outdated sensor setup notice counted a retained reading
  as a temperature arriving, so it could hide for a SATA disk Pulse
  cannot read now.

All four reuse getPhysicalDiskTemperaturePresentation or
isPhysicalDiskTemperatureCurrent instead of adding a predicate.
2026-10-07 12:29:01 +01:00
..