rcourtman e1720ca219 Use unavailable sentinel when VM guest agent disk query fails
When fetchVMFSInfo fails (agent not running, timeout, permission
denied, no filesystems), the builder passed the cluster/resources
numbers through — and PVE always reports 0 used for QEMU — so the UI
rendered a confident "0% (0 B/<allocated>)" for every affected VM
instead of the unavailable dash plus diskStatusReason tooltip. The
agent-disabled path already used the -1 sentinel for exactly this;
apply it on the error path too. The stabilizer can still replace the
sentinel with the previous good sample when recent agent evidence
exists.

Reported by Massimo Simoni (support, 2026-07-13): screenshot showed
every VM at 0% disk with only containers reporting real usage.
2026-07-13 09:41:11 +01:00

186 lines
4.7 KiB
Go

package monitoring
import (
"context"
"errors"
"testing"
"time"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
"github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
)
func TestStabilizeGuestLowTrustDiskCarriesForwardPreviousSnapshot(t *testing.T) {
now := time.Now()
prev := &models.VM{
Type: "qemu",
Status: "running",
LastSeen: now.Add(-time.Minute),
AgentVersion: "8.2.0",
Disk: models.Disk{
Total: 1000,
Used: 400,
Free: 600,
Usage: 40,
},
Disks: []models.Disk{
{Total: 1000, Used: 400, Free: 600, Usage: 40, Mountpoint: "/", Type: "ext4", Device: "/dev/vda"},
},
}
total, used, free, usage, disks, reason := stabilizeGuestLowTrustDisk(
prev,
"running",
1000,
0,
1000,
-1,
nil,
"no-filesystems",
false,
now,
)
if total != 1000 || used != 400 || free != 600 || usage != 40 {
t.Fatalf("unexpected carried-forward disk summary: total=%d used=%d free=%d usage=%.2f", total, used, free, usage)
}
if len(disks) != 1 || disks[0].Device != "/dev/vda" {
t.Fatalf("expected previous disks to be cloned, got %#v", disks)
}
if reason != "prev-no-filesystems" {
t.Fatalf("reason = %q, want prev-no-filesystems", reason)
}
}
func TestStabilizeGuestLowTrustDiskRejectsPreviouslyCarriedForwardSnapshotWithoutAgentEvidence(t *testing.T) {
now := time.Now()
prev := &models.VM{
Type: "qemu",
Status: "running",
LastSeen: now.Add(-time.Minute),
DiskStatusReason: "prev-no-filesystems",
Disk: models.Disk{
Total: 1000,
Used: 400,
Free: 600,
Usage: 40,
},
Disks: []models.Disk{
{Total: 1000, Used: 400, Free: 600, Usage: 40, Mountpoint: "/", Type: "ext4", Device: "/dev/vda"},
},
}
total, used, free, usage, disks, reason := stabilizeGuestLowTrustDisk(
prev,
"running",
1000,
0,
1000,
-1,
nil,
"no-filesystems",
false,
now,
)
if total != 1000 || used != 0 || free != 1000 || usage != -1 {
t.Fatalf("expected current low-trust values to remain, got total=%d used=%d free=%d usage=%.2f", total, used, free, usage)
}
if disks != nil {
t.Fatalf("expected no disks to be carried forward, got %#v", disks)
}
if reason != "no-filesystems" {
t.Fatalf("reason = %q, want no-filesystems", reason)
}
}
func TestStabilizeGuestLowTrustDiskCarriesPreviouslyForwardedSnapshotWithAgentEvidence(t *testing.T) {
now := time.Now()
prev := &models.VM{
Type: "qemu",
Status: "running",
LastSeen: now.Add(-time.Minute),
AgentVersion: "8.2.0",
DiskStatusReason: "prev-no-filesystems",
Disk: models.Disk{
Total: 1000,
Used: 400,
Free: 600,
Usage: 40,
},
Disks: []models.Disk{
{Total: 1000, Used: 400, Free: 600, Usage: 40, Mountpoint: "/", Type: "ext4", Device: "/dev/vda"},
},
}
total, used, free, usage, disks, reason := stabilizeGuestLowTrustDisk(
prev,
"running",
1000,
0,
1000,
-1,
nil,
"no-filesystems",
false,
now,
)
if total != 1000 || used != 400 || free != 600 || usage != 40 {
t.Fatalf("unexpected carried-forward disk summary: total=%d used=%d free=%d usage=%.2f", total, used, free, usage)
}
if len(disks) != 1 || disks[0].Device != "/dev/vda" {
t.Fatalf("expected previous disks to be cloned, got %#v", disks)
}
if reason != "prev-no-filesystems" {
t.Fatalf("reason = %q, want prev-no-filesystems", reason)
}
}
type failingFSInfoClient struct {
PVEClientInterface
err error
}
func (c failingFSInfoClient) GetVMFSInfo(ctx context.Context, node string, vmid int) ([]proxmox.VMFileSystem, error) {
return nil, c.err
}
func TestUpdateVMDisksFromGuestAgentFSInfoErrorUsesUnavailableSentinel(t *testing.T) {
// Cluster/resources reports 0 used for QEMU, so a failed agent query must
// not pass those zeros through as a confident 0% (it renders as
// "0% (0 B/120 GB)" instead of unavailable + reason in the UI).
m := &Monitor{}
res := proxmox.ClusterResource{Node: "pve1", VMID: 100, Name: "vm100", MaxDisk: 128849018880}
client := failingFSInfoClient{err: errors.New("guest agent request timeout")}
total, used, free, usage, disks, fromAgent, reason := m.updateVMDisksFromGuestAgentFSInfo(
context.Background(),
"test-instance",
res,
client,
uint64(res.MaxDisk),
0,
0,
)
if usage != -1 {
t.Fatalf("usage = %v, want -1 sentinel", usage)
}
if reason != "agent-timeout" {
t.Fatalf("reason = %q, want agent-timeout", reason)
}
if fromAgent {
t.Fatal("fromAgent = true, want false")
}
if total != uint64(res.MaxDisk) {
t.Fatalf("total = %d, want allocated size %d", total, res.MaxDisk)
}
if used != 0 || free != total {
t.Fatalf("used/free = %d/%d, want 0/%d", used, free, total)
}
if disks != nil {
t.Fatalf("disks = %v, want nil", disks)
}
}