Files
pulse/internal/monitoring
rcourtman 9d2df76b3f Fix physical disk I/O metrics skipped when SMART data is empty (#1487)
writeHostPhysicalDiskIOMetrics gated ALL per-disk I/O metrics on
host.Sensors.SMART being non-empty. When the agent's SMART collection
fails (smartctl not installed, LXC container can't see /sys/block),
DiskIO data from gopsutil is valid but silently discarded.

Fix: remove the SMART requirement. When no SMART match is found for a
DiskIO entry, try matching against Proxmox API physical disks by device
name (via LinkedNodeID), then fall back to hostID:device as the metric
resource ID. This matches the fallback scheme already used by
HostSMARTDiskSourceID and PhysicalDiskMetaMetricID.

Refs #1487