Two root causes behind #1516's remaining reports: - A node whose Proxmox disks/list query fails (PVE probes SMART per disk inside that call, so dozens of disks can exceed the API window) now falls back to the linked host agent's smartctl inventory instead of leaving the Physical Disks view empty. Each node also gets its own attempt window so one slow node no longer starves the rest of the cluster, and a poll that runs out of budget saves partial results. - The -n standby probe guard is dropped for positively confirmed non-rotational devices in both the host agent and the node sensor wrapper. The guard exists to avoid spinning up sleeping HDDs; an SSD has nothing to spin up, and some SATA SSDs answer CHECK POWER MODE with a bogus standby state that permanently hid their temperature, attributes and history. Refs #1516
149 lines
4.3 KiB
Go
149 lines
4.3 KiB
Go
package monitoring
|
|
|
|
import (
|
|
"context"
|
|
"fmt"
|
|
"testing"
|
|
"time"
|
|
|
|
"github.com/rcourtman/pulse-go-rewrite/internal/alerts"
|
|
"github.com/rcourtman/pulse-go-rewrite/internal/config"
|
|
"github.com/rcourtman/pulse-go-rewrite/internal/models"
|
|
"github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
|
|
)
|
|
|
|
func int64PtrDiskFallback(v int64) *int64 { return &v }
|
|
|
|
func TestPhysicalDisksFromHostAgentSMART_BuildsDisks(t *testing.T) {
|
|
entries := []models.HostDiskSMART{
|
|
{
|
|
Device: "sda",
|
|
Model: "ST18000NM019J",
|
|
Serial: "ZR5DLAYJ",
|
|
WWN: "5-c500-da60ca43",
|
|
Type: "sas",
|
|
SizeBytes: 18000207937536,
|
|
Temperature: 30,
|
|
Health: "PASSED",
|
|
Pool: "tank",
|
|
Attributes: &models.SMARTAttributes{PowerOnHours: int64PtrDiskFallback(327)},
|
|
},
|
|
{
|
|
// Standby entry keeps its identity but carries no health reading.
|
|
Device: "sdb",
|
|
Model: "ST18000NM019J",
|
|
Serial: "ZR5DLXYZ",
|
|
Type: "sas",
|
|
Standby: true,
|
|
},
|
|
{
|
|
// Entries without a device name cannot form a stable ID.
|
|
Device: " ",
|
|
},
|
|
}
|
|
|
|
disks := physicalDisksFromHostAgentSMART("pve1", "node1", entries)
|
|
if len(disks) != 2 {
|
|
t.Fatalf("expected 2 disks, got %d: %+v", len(disks), disks)
|
|
}
|
|
|
|
first := disks[0]
|
|
if first.ID != "pve1-node1--dev-sda" {
|
|
t.Errorf("unexpected ID %q", first.ID)
|
|
}
|
|
if first.DevPath != "/dev/sda" || first.Node != "node1" || first.Instance != "pve1" {
|
|
t.Errorf("unexpected identity fields: %+v", first)
|
|
}
|
|
if first.Health != "PASSED" || first.Temperature != 30 || first.Size != 18000207937536 {
|
|
t.Errorf("unexpected data fields: %+v", first)
|
|
}
|
|
if first.StorageGroup != "tank" {
|
|
t.Errorf("expected pool carried into StorageGroup, got %q", first.StorageGroup)
|
|
}
|
|
if first.SmartAttributes == nil || first.SmartAttributes.PowerOnHours == nil || *first.SmartAttributes.PowerOnHours != 327 {
|
|
t.Errorf("expected SMART attributes carried over, got %+v", first.SmartAttributes)
|
|
}
|
|
if first.Wearout != -1 {
|
|
t.Errorf("expected wearout unknown (-1) without wear attributes, got %d", first.Wearout)
|
|
}
|
|
|
|
second := disks[1]
|
|
if second.DevPath != "/dev/sdb" || second.Health != "UNKNOWN" {
|
|
t.Errorf("expected standby disk listed with UNKNOWN health, got %+v", second)
|
|
}
|
|
|
|
if got := physicalDisksFromHostAgentSMART("pve1", "node1", nil); got != nil {
|
|
t.Errorf("expected nil for empty SMART inventory, got %+v", got)
|
|
}
|
|
}
|
|
|
|
type disksErrorPVEClient struct {
|
|
fakeStorageClient
|
|
}
|
|
|
|
func (*disksErrorPVEClient) GetDisks(ctx context.Context, node string) ([]proxmox.Disk, error) {
|
|
return nil, fmt.Errorf("596 connection timed out")
|
|
}
|
|
|
|
// A node whose Proxmox disks/list query fails (wide nodes can exceed the API
|
|
// window) must still populate its Physical Disks view from the linked host
|
|
// agent's SMART inventory instead of silently emptying (#1516).
|
|
func TestMaybePollPhysicalDisksAsync_AgentFallbackWhenDiskQueryFails(t *testing.T) {
|
|
m := &Monitor{
|
|
state: models.NewState(),
|
|
lastPhysicalDiskPoll: make(map[string]time.Time),
|
|
alertManager: alerts.NewManager(),
|
|
}
|
|
|
|
m.state.UpdateNodesForInstance("pve1", []models.Node{{
|
|
ID: "pve1-node1",
|
|
Name: "node1",
|
|
Instance: "pve1",
|
|
LinkedAgentID: "host-1",
|
|
}})
|
|
m.state.UpsertHost(models.Host{
|
|
ID: "host-1",
|
|
Hostname: "node1",
|
|
Sensors: models.HostSensorSummary{
|
|
SMART: []models.HostDiskSMART{{
|
|
Device: "sda",
|
|
Model: "ST18000NM019J",
|
|
Serial: "ZR5DLAYJ",
|
|
Type: "sas",
|
|
SizeBytes: 18000207937536,
|
|
Temperature: 30,
|
|
Health: "PASSED",
|
|
}},
|
|
},
|
|
})
|
|
|
|
m.maybePollPhysicalDisksAsync(
|
|
context.Background(),
|
|
"pve1",
|
|
&config.PVEInstance{},
|
|
&disksErrorPVEClient{},
|
|
[]proxmox.Node{{Node: "node1", Status: "online"}},
|
|
map[string]string{"node1": "online"},
|
|
[]models.Node{{Name: "node1"}},
|
|
)
|
|
|
|
deadline := time.Now().Add(3 * time.Second)
|
|
for {
|
|
disks := m.state.GetSnapshot().PhysicalDisks
|
|
if len(disks) == 1 {
|
|
disk := disks[0]
|
|
if disk.DevPath != "/dev/sda" || disk.Node != "node1" || disk.Instance != "pve1" {
|
|
t.Fatalf("unexpected fallback disk identity: %+v", disk)
|
|
}
|
|
if disk.Health != "PASSED" || disk.Temperature != 30 {
|
|
t.Fatalf("unexpected fallback disk data: %+v", disk)
|
|
}
|
|
return
|
|
}
|
|
if time.Now().After(deadline) {
|
|
t.Fatalf("expected fallback physical disk from host agent SMART, got %+v", disks)
|
|
}
|
|
time.Sleep(10 * time.Millisecond)
|
|
}
|
|
}
|