a85bdcdc9a
## Problem PR #2648 stopped the poller's previous-evidence lookup from handing a replaced disk the old disk's serial. The linked host agent's SMART merge runs before that lookup and had the same flaw. Its last-resort match is the device path, and a path names a slot, not a disk. When a disk is swapped before the agent reports again, or after the agent went silent and kept its last rows, the agent's row for the old disk matched the replacement. It filled the old serial or, for SAS, promoted it over the Proxmox SAS address. The registry then keyed the replacement to the old disk's canonical resource and SMART history, and it also took the old disk's temperature and FAILED health. For SAS, the registry's same-path join (`resolveLinkedPhysicalDisk`) did the same at the canonical level even when monitoring kept the rows apart. Proxmox's disk inventory (`PVE::Diskmanage`, checked on a PVE 9 node) writes the literal `unknown` for a serial or WWN udev cannot read. The poller recorded it as a collected serial, so the collection state hid the gap, and the merge's `Serial == ""` fill never let the agent's real serial replace it. ## Change - `mergeHostAgentSMARTIntoDisks` refuses a device-path row whose identity contradicts the Proxmox disk's. The new `diskinventory.HardwareIdentityConflict` defines a contradiction: nothing agrees across serial and WWN, and a field both producers report like for like disagrees. - WWNs count for every disk. - Serials count only where Proxmox's serial is the drive's own, as smartctl's is: a disk typed `nvme`, or one presented with SCSI vendor `ATA` (libata, or a SAS HBA's SCSI-ATA translation) and not typed `usb`/`sas`. Elsewhere the Proxmox serial may be a SAS address or SCSI designator (#1595) or a USB bridge's own serial, so it only counts toward agreement. - Spelling differences are not disagreement: udev's underscores for whitespace, a T10 designator for an ATA drive (`ATA`, the model, then the serial), the agent's NAA field spelling, and udev's 64-bit prefix of an NAA 6 WWN. - The refusal runs after the unique-path check, so a second row on the path keeps the match ambiguous. - The merge's WWN step compares normalized identity (`HardwareIdentityMatch`), so the agent's `5-c50-a1b2c3d4` finds the Proxmox `0x5000c500a1b2c3d4` disk. - `resolveLinkedPhysicalDisk` refuses the SAS same-path fallback when the two WWNs name different disks. - The poller records Proxmox's `unknown` serial/WWN as empty, so the serial reads `missing` and the agent can fill it. Retained evidence carries a previous serial only when it is usable, so a pre-upgrade record cannot restore the placeholder. Identity keys already ignored the placeholder. When the agent now fills a disk's serial, that disk's Proxmox-poll SMART samples move from its WWN or path key to the serial key, where the agent's own samples already go. ## Tests - `TestHostAgentSMARTRowForSwappedOutDiskDoesNotLendItsIdentity` (sata and sas) drives the real poller and registry. Proxmox reports `unknown`, the agent fills the serial, the agent goes silent, and the disk is swapped. On main, the SATA replacement takes the old serial and resource; the SAS replacement keeps its own serial in state, but the registry joins it to the old resource with its temperature and FAILED health. - `TestHostAgentSMARTMergeRefusesPathMatchAcrossContradictingIdentity` has one row per producer rule: SAS/SATA/NVMe replacements refused; same-disk SAS without an agent WWN, a renamed SAS disk in the agent's WWN spelling, udev's serial spelling, a USB enclosure (typed `usb` and typed `ssd`), a T10 designator and an NAA 6 volume merged; and an ambiguous path. - `TestRegistrySASPathJoinRefusesContradictingWWN`, `TestProxmoxUnknownDiskIdentityIsRecordedAsUnreported` and `TestHardwareIdentityConflict` cover the rest. - Negative controls via `go test -overlay`: removing each rule fails only its own case. These cover the guard, the WWN normalization, the transport/vendor rule, compaction, the designator rule, the NAA 6 prefix, the registry guard, the ingest normalization and the usable-serial carry. Against main's `monitor.go` and `registry.go`, the end-to-end, merge and registry tests fail. - `TestMergeHostAgentSMARTIntoDisks_PreservesExistingProxmoxIdentity` merged a row with a different WWN by path alone, which the guard now rightly refuses. Its row is now the same disk in the agent's WWN spelling, with all assertions unchanged. - `internal/monitoring`, `internal/unifiedresources` and `pkg/diskinventory` pass in full. ## Not covered - A replacement with no comparable identity still matches its path: no usable serial or WWN at all, or a SAS/SCSI/USB disk with a WWN on one side only. - The registry's seeded source mapping, reused after a restart by the slot-shaped Proxmox source ID, can still hand a swapped disk the old canonical resource. That's a separate follow-up.