## Problem

A physical disk behind a RAID controller (target such as `megaraid,3`)
with no usable serial or WWN had its SMART history written under one key
and read under another, so its temperature and SMART charts stayed
empty.

- Host agent: writes under `HostSMARTDiskMetricID`, e.g.
`host-pve:sdd@ctrl0/megaraid,3`.
- Proxmox: writes under `PhysicalDiskMetricID`, which returns
`ProxmoxPhysicalDiskSourceID`, e.g.
`pve-node1--dev-sdx:sdx@/megaraid,0`.
- Reader: `BuildMetricsTarget` passed those source IDs, which already
name the member, to `PhysicalDiskMetaMetricID`. That function appended
the topology again:
`host-pve:sdd@ctrl0/megaraid,3:sdd@ctrl0/megaraid,3`. The same happened
in a registry rehydrated from persisted resources.

## Fix

`PhysicalDiskMetaMetricID` now follows the Proxmox writer. A fallback
that already ends in the member's topology is returned unchanged. The
topology is appended only to a fallback without it:
- a Proxmox source ID from before members were scoped, which
`PhysicalDiskMetricID` scopes the same way;
- the canonical resource ID that `PhysicalDiskView.MetricResourceID`
falls back to.

TrueNAS disks carry no controller target and are unaffected.

## Existing history

- **SMART:** no SMART writer used the doubled key, so samples already
stored become readable without a migration.
- **Disk I/O:** a linked node's agent with no SMART reading for a
member, such as a standby row, files the device's I/O under the Proxmox
disk's metrics target. That target was the doubled key. The I/O now
lands beside the member's SMART history. Samples already stored under
the doubled key are left to age out: nothing reads them, and they are
the block path's counter filed under its one merged member.
- Mock seeding keys these disks by `disk.ID`, the single-scoped key, so
it already matched.

## Proof

- `TestIdentitylessControllerMembersReadTheirWritersHistory`
(`internal/monitoring/issue1595_collection_trust_test.go`) drives the
real writers: `writeHostSMARTMetrics`, `writeHostPhysicalDiskIOMetrics`
and the Proxmox `writeSMARTMetrics`. It then queries the store at
`MetricsTarget` for five members in a live registry and in one
rehydrated through a JSON round trip. The members are two agent members
sharing a path, a lone agent member with I/O, a Proxmox member, and a
standby member merged into its linked node's Proxmox row. Before the fix
all ten targets read the doubled key.
- `TestPhysicalDiskMetaMetricIDScopesAControllerMemberOnce`
(`internal/unifiedresources/canonical_ids_types_test.go`) pins each
fallback shape against its writer: agent, smartctl-labelled agent,
Proxmox, legacy Proxmox, canonical resource ID, and a disk that is no
controller member. Before the fix, three cases failed with the doubled
key.

## Stacking

This branch sits on #2685, which sits on #2679, because both edit
`physical_disk_ids.go` and the proof file. It supersedes #2661, which
carried the same reader fix but conflicted with this stack and with
main.
2026-10-07 19:31:12 +01:00
..