Alerts > History is a log of occurrences, but its open row is the one still in progress: it shows an Active badge and a running duration, so "Node temperature at 95.0°C" beside them reads as the reading now while the node sits at 78°C under its 80°C trigger. The Alerts card one tab away already says "78°C now, back under the 80°C alert level", so the two pages disagreed about the same alert. An active row for a threshold alert with a usable live status now leads with the same presentation summary. The desktop row keeps the clear rule and the last breach in its hover; the phone card shows them as muted lines because a phone has no hover. The row's description stays the recorded message, so search and the Assistant handoff still read the record, and closed rows and open rows without a live status are unchanged. The reading rechecks on the shared clock, read only for open rows, so it turns stale when evaluations stop without re-rendering every closed row on each tick. Refs #2068