Files
pulse/docs/release-control
rcourtman 5feda4836c Lead open History rows with the live reading of held alerts
Alerts > History is a log of occurrences, but its open row is the one
still in progress: it shows an Active badge and a running duration, so
"Node temperature at 95.0°C" beside them reads as the reading now while
the node sits at 78°C under its 80°C trigger. The Alerts card one tab
away already says "78°C now, back under the 80°C alert level", so the
two pages disagreed about the same alert.

An active row for a threshold alert with a usable live status now leads
with the same presentation summary. The desktop row keeps the clear rule
and the last breach in its hover; the phone card shows them as muted
lines because a phone has no hover. The row's description stays the
recorded message, so search and the Assistant handoff still read the
record, and closed rows and open rows without a live status are
unchanged. The reading rechecks on the shared clock, read only for open
rows, so it turns stale when evaluations stop without re-rendering every
closed row on each tick.

Refs #2068
2026-10-07 08:54:49 +01:00
..