A Proxmox disk that only the node's sensors report never raised a temperature alert: CheckDiskHealth judges health and wearout only, and unified evaluation covers TrueNAS disks, not PVE ones. Physical Disks could read the disk Running Hot under the per-type thresholds while alerts stayed silent, and whether a disk alerted depended on whether a Pulse agent happened to run on the node. The PVE disk poller now hands each disk's current reading to CheckProxmoxDiskTemperature, which judges it by the same disk temperature policy as agent and TrueNAS disks (DiskTempByType under the agent Disk Temp default) under the disk's existing PVE alert reference. A disk a still-reporting linked agent lists in its SMART report is the agent's: CheckHost alerts on it and the PVE alert closes as moved to the agent, so no disk alerts twice. A retained reading holds the alert, an excluded device or a switched-off policy closes it, warnings wait the same 300s stability window as other disk temperatures, a config save re-judges the alert per disk type, and resource history owns its rows by the disk's recorded identity like the health and wearout alerts.