A review of #2569 (node temperature alerts with a host agent) found three more ways node alerts went wrong. Each was reproduced with a test that fails on `main`. ## Changes - **Dedup follows the agent's node link, not its hostname.** Node deduplication matched an agent's hostname against node names across every PVE instance. With two instances that each have a node called `pve` and an agent on only one, both nodes released their CPU, memory and disk alerts, so the second machine went unmonitored. An agent reporting an FQDN never matched its node, so that machine alerted twice. An operator unlinking an agent didn't hand the alerts back either. The manager now tracks each reporting agent's `LinkedNodeID`, which the monitor already sets automatically or from an operator link. On pulse-prod the delly2 agent is linked to `homelab-delly2`, the same ID as the node alert it should dedup. - **A config save keeps node thresholds.** Saving the alert config resolved node temperature alerts that were still over their trigger. Reevaluation only treated an alert as a node alert when its `Instance` equalled its node name. Current node alerts keep the PVE instance name there (`homelab`), so they fell through to guest thresholds, and guests have no temperature threshold. Metadata `resourceType: node` now decides, and the `Instance` heuristic only covers legacy alerts that have no resource type. - **Missing readings interrupt timing runs.** Since #2569, a missing temperature reading no longer resolves an open alert, but a pending run still spanned the gap. One hot sample after ten minutes without readings fired at once, and a recovery run could complete the same way. The reducer gains `InterruptMetricRun`, which drops a pending run or restarts a recovery run without resolving anything. The node temperature check calls it, along with the explicit-intent pending clear, when the reading is missing. ## Not in this PR Two other review findings are filed separately: - When collection fails, the poller re-presents a stale temperature as current with no time limit, and alerting treats it as live. The fix touches the poller, mock timestamps and what the UI shows. - At handover, the released node alert closes with "now healthy" wording. That needs a typed resolution reason in notifications. ## Tests - `TestHostAgentDeduplicationFollowsNodeLink`: same-named nodes in two instances, an FQDN hostname, an unlinked agent, and an operator unlink. - `TestConfigSaveKeepsNodeTemperatureAlertOverTrigger`: fails on `main`. - `TestCheckNodeMissingTemperatureInterruptsTimingRuns`: fails on `main` (one sample back after the gap fires at once). - The existing dedup tests now use link semantics. `go test ./internal/alerts/...` passes, and so do the monitoring alert, temperature, host-agent and node tests.
Pulse documentation
Start here for installation, platform setup, security, operations, and Pulse Intelligence. Commands, configuration keys, image names, API fields, and product identifiers remain untranslated in localized guides.
Start here
- Install Pulse — signed Proxmox/Linux installation, Docker, Docker Compose, Kubernetes, and first-run setup.
- Production deployment and security — least-privilege Proxmox setup, root-agent boundaries, discovery, supply-chain verification, plan limits, scale evidence, and a rollout checklist.
- Upgrade from Pulse v5 — migration prerequisites, rollback, agent continuity, and post-upgrade checks.
- Releases and update channels: choosing Stable or Preview, beta and RC expectations, and how releases are tested and promoted.
- Configure Pulse — authentication, notifications, discovery, retention, and system settings.
- Deployment models — data locations, lifecycle, and differences between supported deployment paths.
- Troubleshooting and FAQ — common failures, diagnostics, and operator questions.
Localized getting started guides: Deutsch · Español
Platforms and agents
- Proxmox Backup Server
- Proxmox Mail Gateway
- Docker and Podman
- Kubernetes and Helm
- TrueNAS SCALE and CORE
- Unified Agent
- Agent security
- VM disk monitoring
- ZFS monitoring
- Temperature monitoring
VMware vSphere support is early access. Current builds expose dedicated vSphere inventory and recovery context, but operators should validate the integration against their own vCenter before production use.
Monitoring and operations
- Metrics history
- Recovery data
- Webhooks
- Automatic updates
- Centralized agent management (Pro)
- Operational trust model
- Current product screenshots
Pulse Intelligence
- Assistant, Patrol, and external-agent overview
- Patrol modes and safety
- Assistant safety model
- External agent HTTP and MCP substrate
Patrol watch-only analysis is available on Community with a local model or the operator's own provider. Investigation and governed fixes require the relevant Pulse Pro capabilities.
Security, privacy, and access
- Production deployment and security
- Security review scope
- Authentication and credential storage review packet
- Security guide
- Privacy and telemetry disclosure
- OIDC and SSO
- Proxy authentication
- Role-based access control (Pro)
- Audit logging (Pro)
- Reverse proxy configuration
- Code-signing policy
Plans and managed access
- Community, Relay, and Pro capabilities
- Relay and Pulse Mobile handoff
- Multi-tenant organizations (Enterprise/custom)
- Provider-hosted MSP operations (request-assisted)
Pulse Cloud is not generally available. Ordinary self-hosted Pulse remains the primary installation path; MSP and Enterprise access are explicit commercial paths rather than defaults in self-hosted setup.
Development and reference
Detailed design notes and dated migration specifications may remain in this directory for maintainers, but they are not operator setup guides unless they are linked from the sections above.
Previous versions and migrations
- Upgrade from v4 to v5
- Retired unified-navigation migration — historical context only; current Pulse uses platform-shaped navigation.
- Move a Pulse installation
Found a bug? Use the issue forms. For setup questions, use GitHub Discussions.