The first version of this change walked every temperature source and took the first usable one, which changed two cases that worked before. Details holding only NVMe or GPU readings displaced a valid scalar CPU reading, so the node lost its CPU temperature. An unusable earlier record no longer fell back to the scalar; the walk went on to a later record that was marked unavailable and suppressed the display. The record selection is back to exactly what it was. Only when it yields nothing usable does the adapter use proxmox.temperatureDetails, and only if that holds a current CPU reading; otherwise it falls back to the scalar as before, still without inventing a low or record. The contract notes now say the adapter forwards the poller's low and record values and that keeping them across polls is the poller's job.