Files
pulse/docs
rcourtman 33bcf698e0 Keep node temperature alerts when a host agent runs on the node
Installing a Pulse agent on a Proxmox node silently ended CPU
temperature alerting for it. CheckNode skipped every node metric,
temperature included, once a host agent with the node's hostname
registered, but CheckHost evaluates only CPU, memory and disk usage and
SMART disk temperatures, never CPU temperature. On pulse-prod the last
node temperature alert fired on 5 October; delly2 has since read 90°C
and minipc 78-87°C with no alert.

Temperature now stays with the node whether or not an agent is
registered. The node poll already merges the agent's sensors into
node.Temperature, so this gives one temperature alert per machine.

The dedup skip path also never cleared node alerts it stopped
evaluating, so a node alert open when the agent registered stayed
frozen until the agent went offline. pulse-prod shows this today: the
delly2 node memory alert, open since 29 September, beside the agent's
own memory alert. CheckNode now releases node CPU, memory and disk
alerts through the disabled-threshold path, which drops the pending run
and resolves the open alert, leaving the agent as the only owner.

A missing CPU reading also fed 0°C into the evaluator, which could
resolve an open temperature alert without any evidence that the node had
cooled. With a live trigger the check now skips the evaluation instead,
while a disabled threshold still clears.
2026-10-06 13:43:47 +01:00
..
…
…
2026-10-05 21:53:41 +01:00
…
…
…
…
…
…
2026-10-05 21:53:41 +01:00
2026-10-05 21:53:41 +01:00

Pulse documentation

Start here for installation, platform setup, security, operations, and Pulse Intelligence. Commands, configuration keys, image names, API fields, and product identifiers remain untranslated in localized guides.

Start here

  • Install Pulse — signed Proxmox/Linux installation, Docker, Docker Compose, Kubernetes, and first-run setup.
  • Production deployment and security — least-privilege Proxmox setup, root-agent boundaries, discovery, supply-chain verification, plan limits, scale evidence, and a rollout checklist.
  • Upgrade from Pulse v5 — migration prerequisites, rollback, agent continuity, and post-upgrade checks.
  • Releases and update channels: choosing Stable or Preview, beta and RC expectations, and how releases are tested and promoted.
  • Configure Pulse — authentication, notifications, discovery, retention, and system settings.
  • Deployment models — data locations, lifecycle, and differences between supported deployment paths.
  • Troubleshooting and FAQ — common failures, diagnostics, and operator questions.

Localized getting started guides: Deutsch · Español

Platforms and agents

VMware vSphere support is early access. Current builds expose dedicated vSphere inventory and recovery context, but operators should validate the integration against their own vCenter before production use.

Monitoring and operations

Pulse Intelligence

Patrol watch-only analysis is available on Community with a local model or the operator's own provider. Investigation and governed fixes require the relevant Pulse Pro capabilities.

Security, privacy, and access

Plans and managed access

Pulse Cloud is not generally available. Ordinary self-hosted Pulse remains the primary installation path; MSP and Enterprise access are explicit commercial paths rather than defaults in self-hosted setup.

Development and reference

Detailed design notes and dated migration specifications may remain in this directory for maintainers, but they are not operator setup guides unless they are linked from the sections above.

Previous versions and migrations

Found a bug? Use the issue forms. For setup questions, use GitHub Discussions.