rcourtman dd8bfa4db8 Stop QEMU default disk serials merging nested Proxmox disks
QEMU gives a virtual disk configured without a serial one built from
its drive ID or a per-VM counter, so every VM built the same way reports
the same value. Proxmox's disks/list serial is udev's ID_SERIAL_SHORT,
which for a virtio-scsi disk is "drive-scsi0" (libvirt:
"drive-scsi0-0-0-0"), and an ATA disk's serial is "QM00001".
IsUsableHardwareID accepted these as hardware identity, so every node of
a nested Proxmox cluster minted one machine:drive-scsi0 canonical disk
and one SMART series, and all but one node lost the disk from inventory.

IsUsableHardwareID now rejects exactly QEMU's default shapes: drive-scsi
plus digits with at most three -digits groups, QEMU's automatic drive
IDs scsiN-hdN and noneN, and QM plus five digits. Real serials that
share a prefix, such as DRIVE-ASSET123, stay identity. It also strips
WWN framing before the all-zero test, so a 0x0000000000000000 WWN is a
placeholder too.

The TrueNAS provider set a disk's canonical identity from any non-empty
serial, so placeholders merged disks across appliances. It now uses only
a usable serial. For a serial that was already rejected, such as
UNKNOWN, native TrueNAS history and the unified SMART writer disagreed
with the chart reader: native history used TrueNAS's disk identifier,
and the writer substituted the metrics target only for an empty serial,
so a placeholder sent samples to the canonical resource ID. Rejecting
QEMU serials would have put TrueNAS VMs on that path. Both now use the
key the registry's metrics target resolves, the disk's source ID, and
native history lookups no longer route by placeholder serials.

Disks that report one of these values change canonical ID and SMART
metric key once; samples under the old key are not carried over because
that key mixed every disk that shared the value.
2026-10-07 11:51:16 +01:00
rcourtman 9b644b3d49 Stop a replaced PVE disk inheriting the old disk's evidence
The disk poller keeps evidence it could not collect this poll by looking
up the previous record, first by serial and WWN, then by the Proxmox
source ID and device token. Those last two name a slot, not a disk, and
a replacement in the same slot keeps both. So a replacement reporting a
different serial or WWN took the old disk's retained temperature,
controller, pool and I/O. A replacement record with an empty serial
also took the old serial. The registry keys disks on serial, so the
new disk became the old disk's canonical resource and SMART metric
series, and each later poll carried the borrowed serial forward.

Match on hardware identity through diskinventory.HardwareIdentityMatch,
serial first then WWN, and refuse a slot match when both records carry
a serial or WWN that share no value. Missing identity is still not a
conflict, so Proxmox's literal "unknown" and other placeholders keep
the slot's evidence as before.

The registry's merged disk view keeps the host agent's WWN, which the
agent spells as unpadded NAA 5 fields ("5-c50-a1b2c3d4") while Proxmox
reports "0x5000c500a1b2c3d4". HardwareIdentityMatch now re-pads that
spelling for WWN fields, so the same disk seen by both reporters is
not mistaken for a replacement.
2026-10-07 11:23:34 +01:00
Pulse Test 674ca18968 fix(unifiedresources): merge PVE and agent rows for the same RAID array volume
The PVE disks/list poll and the agent SMART report both observe a RAID
controller's exported volume, but PVE surfaces its NAA identifier as a
bare-hex serial while smartctl reports the same value as a naa.-prefixed
WWN with no serial. The linked-disk join compared serial to serial and
WWN to WWN verbatim, so the volume rendered twice (/dev/sda and sda)
with independent metric histories.

Hardware identity comparison now normalizes reporter framing (naa., eui.,
wwn-, 0x prefixes, case) and folds serial and WWN together before
comparing. Values are never truncated: sibling volumes on one controller
share their leading WWN bytes, and a truncated udev ID_WWN must stay
unequal to a full identifier. Placeholder serials no longer count as an
identity match.

Refs #1720