Disk temperature by type
- Alert trigger in °C for each disk type, for agent and TrueNAS disks. Warning colors
- start 5°C below the trigger. A Disk Temp override on a host above replaces these for
- all of that host's disks, and a TrueNAS Disks value replaces them for TrueNAS disks.
+ Alert trigger in °C for each disk type, for agent, TrueNAS and Proxmox disks. Warning
+ colors start 5°C below the trigger. A Disk Temp override on a host above replaces
+ these for all of that host's disks, and a TrueNAS Disks value replaces them for
+ TrueNAS disks.
diff --git a/frontend-modern/src/components/Alerts/__tests__/ThresholdsTable.test.tsx b/frontend-modern/src/components/Alerts/__tests__/ThresholdsTable.test.tsx
index 06dd27a8c5..dd57de354b 100644
--- a/frontend-modern/src/components/Alerts/__tests__/ThresholdsTable.test.tsx
+++ b/frontend-modern/src/components/Alerts/__tests__/ThresholdsTable.test.tsx
@@ -457,6 +457,25 @@ describe('ThresholdsTable navigation and redirection', () => {
});
});
+ it('says Disk temperature by type covers agent, TrueNAS and Proxmox disks', async () => {
+ setPathname('/alerts/thresholds/systems');
+ const host: Agent = {
+ id: 'legacy-h1',
+ hostname: 'legacy-host',
+ displayName: 'Legacy Host',
+ status: 'online',
+ lastSeen: 123,
+ memory: { total: 100, used: 50, free: 50, usage: 50 },
+ };
+
+ render(() => );
+
+ const heading = await screen.findByText('Disk temperature by type');
+ expect(heading.parentElement?.textContent).toContain(
+ 'for each disk type, for agent, TrueNAS and Proxmox disks',
+ );
+ });
+
it('navigates to correct route when tabs are clicked', () => {
render(() => );
diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.go
index 5dfafdca51..c5a8992366 100644
--- a/internal/alerts/alerts_test.go
+++ b/internal/alerts/alerts_test.go
@@ -22173,14 +22173,20 @@ func TestStaleCleanupKeepsThresholdAlertStillBeingEvaluated(t *testing.T) {
// Resource history owns each PVE disk alert row by the hardware identity the
// alert records, and reads by the path reference find those rows by alert
-// identifier. Both must match what CheckDiskHealth produces.
+// identifier. Both must match what CheckDiskHealth and
+// CheckProxmoxDiskTemperature produce.
func TestCheckDiskHealthAlertsCarryHistoryOwnershipIdentity(t *testing.T) {
m := newTestManager(t)
m.ClearActiveAlerts()
+ m.mu.Lock()
+ m.config.TimeThresholds = map[string]int{}
+ m.config.MetricTimeThresholds = nil
+ m.mu.Unlock()
disk := proxmox.Disk{DevPath: "/dev/sdb", Model: "Crucial MX500", Serial: "2117E59AB123", WWN: "0x5002538f12345678",
Type: "ssd", Health: "FAILED", Wearout: 3}
for i := 0; i < 3; i++ {
m.CheckDiskHealth("lab", "pve1", disk)
+ m.CheckProxmoxDiskTemperature("lab", "pve1", ProxmoxDiskTemperatureReading{Disk: disk, Celsius: 80})
}
ref := unifiedresources.ProxmoxPhysicalDiskAlertResourceID("lab", "pve1", disk.DevPath)
@@ -22201,3 +22207,187 @@ func TestCheckDiskHealthAlertsCarryHistoryOwnershipIdentity(t *testing.T) {
}
}
}
+
+func proxmoxTemperatureDisk(devPath, diskType string) proxmox.Disk {
+ return proxmox.Disk{DevPath: devPath, Model: "Test Disk", Serial: "SER-" + devPath, Type: diskType, Health: "PASSED"}
+}
+
+func proxmoxDiskTemperatureAlert(t *testing.T, m *Manager, devPath string) (*Alert, bool) {
+ t.Helper()
+ ref := unifiedresources.ProxmoxPhysicalDiskAlertResourceID("lab", "pve1", devPath)
+ return testLookupActiveAlert(t, m, canonicalMetricStateID(ref, proxmoxDiskTemperatureMetric))
+}
+
+func proxmoxDiskTemperatureResolution(m *Manager, devPath string) (*models.AlertResolution, bool) {
+ ref := unifiedresources.ProxmoxPhysicalDiskAlertResourceID("lab", "pve1", devPath)
+ id := canonicalMetricStateID(ref, proxmoxDiskTemperatureMetric)
+ for _, resolved := range m.GetRecentlyResolved() {
+ if resolved.ID == id {
+ return resolved.Resolution, true
+ }
+ }
+ return nil, false
+}
+
+// TestProxmoxDiskTemperatureAlertsFollowDiskTemperaturePolicy pins Proxmox disk
+// temperature alerts to the disk temperature policy that judges an agent's
+// disks, TrueNAS disks and the Physical Disks verdict.
+func TestProxmoxDiskTemperatureAlertsFollowDiskTemperaturePolicy(t *testing.T) {
+ m := newTestManager(t)
+ configureUnifiedEvalManager(t, m, unifiedEvalBaseConfig())
+
+ check := func(devPath, diskType string, celsius int) {
+ m.CheckProxmoxDiskTemperature("lab", "pve1", ProxmoxDiskTemperatureReading{Disk: proxmoxTemperatureDisk(devPath, diskType), Celsius: celsius})
+ }
+ check("/dev/nvme0n1", "nvme", 63)
+ check("/dev/nvme1n1", "nvme", 72)
+ check("/dev/sda", "sata", 56)
+ check("/dev/sdb", "sas", 63)
+
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/nvme0n1"); firing {
+ t.Fatalf("NVMe at 63C fired under its 70C trigger: %v", alertKeys(m))
+ }
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/sdb"); firing {
+ t.Fatalf("SAS at 63C fired under its 65C trigger: %v", alertKeys(m))
+ }
+ for devPath, trigger := range map[string]float64{"/dev/nvme1n1": 70, "/dev/sda": 55} {
+ alert, firing := proxmoxDiskTemperatureAlert(t, m, devPath)
+ if !firing {
+ t.Fatalf("%s did not fire: %v", devPath, alertKeys(m))
+ }
+ if alert.Threshold != trigger {
+ t.Fatalf("%s trigger = %v, want %v", devPath, alert.Threshold, trigger)
+ }
+ if alert.Type != proxmoxDiskTemperatureMetric || alert.Metadata["resourceType"] != proxmoxDiskResourceType {
+ t.Fatalf("%s alert type %q, resourceType %v", devPath, alert.Type, alert.Metadata["resourceType"])
+ }
+ if alert.Metadata["diskType"] == nil || alert.Metadata[unifiedresources.MetadataDiskSerial] != "SER-"+devPath {
+ t.Fatalf("%s metadata = %v", devPath, alert.Metadata)
+ }
+ }
+ if alert, _ := proxmoxDiskTemperatureAlert(t, m, "/dev/sda"); alert.Message != "Disk temperature at 56.0°C" {
+ t.Fatalf("message = %q", alert.Message)
+ }
+
+ // A raised NVMe trigger moves NVMe disks with it.
+ m.mu.Lock()
+ m.config.DiskTempByType["nvme"] = HysteresisThreshold{Trigger: 75, Clear: 70}
+ m.mu.Unlock()
+ check("/dev/nvme2n1", "nvme", 72)
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/nvme2n1"); firing {
+ t.Fatalf("NVMe at 72C fired under a 75C trigger")
+ }
+}
+
+// A disk the linked agent reports is the agent's: its open alert closes as
+// moved to the agent, and the disk never alerts twice. An excluded disk, or a
+// policy the agent Disk Temp default switched off, closes it as a plain clear.
+// A disk with no current reading keeps its alert.
+func TestProxmoxDiskTemperatureAlertOwnershipAndHolds(t *testing.T) {
+ m := newTestManager(t)
+ configureUnifiedEvalManager(t, m, unifiedEvalBaseConfig())
+ disk := proxmoxTemperatureDisk("/dev/sda", "sata")
+ read := func(reading ProxmoxDiskTemperatureReading) {
+ reading.Disk = disk
+ m.CheckProxmoxDiskTemperature("lab", "pve1", reading)
+ }
+ firing := func() bool {
+ _, ok := proxmoxDiskTemperatureAlert(t, m, "/dev/sda")
+ return ok
+ }
+
+ read(ProxmoxDiskTemperatureReading{Celsius: 60})
+ if !firing() {
+ t.Fatalf("SATA at 60C did not fire: %v", alertKeys(m))
+ }
+ read(ProxmoxDiskTemperatureReading{Celsius: 0})
+ if !firing() {
+ t.Fatalf("a poll without a current reading resolved the alert")
+ }
+
+ read(ProxmoxDiskTemperatureReading{Celsius: 60, AgentOwned: true})
+ if firing() {
+ t.Fatalf("an agent-owned disk kept its Proxmox temperature alert")
+ }
+ if resolution, ok := proxmoxDiskTemperatureResolution(m, "/dev/sda"); !ok || resolution == nil || resolution.Reason != string(AlertResolutionMovedToAgent) {
+ t.Fatalf("handover resolution = %+v (resolved %v), want moved_to_agent", resolution, ok)
+ }
+ read(ProxmoxDiskTemperatureReading{Celsius: 80, AgentOwned: true})
+ if firing() {
+ t.Fatalf("an agent-owned disk raised a Proxmox temperature alert")
+ }
+
+ read(ProxmoxDiskTemperatureReading{Celsius: 60})
+ if !firing() {
+ t.Fatalf("the disk did not alert again once the agent stopped listing it")
+ }
+ read(ProxmoxDiskTemperatureReading{Celsius: 60, Excluded: true})
+ if firing() {
+ t.Fatalf("an excluded disk kept its temperature alert")
+ }
+
+ read(ProxmoxDiskTemperatureReading{Celsius: 60})
+ m.mu.Lock()
+ m.config.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 0, Clear: 0}
+ m.mu.Unlock()
+ read(ProxmoxDiskTemperatureReading{Celsius: 60})
+ if firing() {
+ t.Fatalf("a switched-off agent Disk Temp default kept the Proxmox disk alert")
+ }
+}
+
+// A Proxmox disk temperature warning waits out the factory stability window for
+// a noisy gauge, as agent and TrueNAS disk temperature warnings do; a critical
+// reading bypasses it.
+func TestProxmoxDiskTemperatureWarningWaitsOutStabilityWindow(t *testing.T) {
+ m := newTestManager(t)
+ cfg := unifiedEvalBaseConfig()
+ m.UpdateConfig(cfg)
+ if delay := m.GetConfig().TimeThresholds[proxmoxDiskResourceType]; delay != 5 {
+ t.Fatalf("proxmox-disk delay = %d, want the 5s factory default", delay)
+ }
+ m.mu.RLock()
+ grace := m.getTimeThreshold("lab:pve1:disk:dev-sda", proxmoxDiskResourceType, proxmoxDiskTemperatureMetric)
+ m.mu.RUnlock()
+ if grace != defaultNoisyGaugeStabilitySeconds {
+ t.Fatalf("Proxmox disk temperature delay = %ds, want the %ds stability window", grace, defaultNoisyGaugeStabilitySeconds)
+ }
+
+ m.CheckProxmoxDiskTemperature("lab", "pve1", ProxmoxDiskTemperatureReading{Disk: proxmoxTemperatureDisk("/dev/sda", "sata"), Celsius: 57})
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/sda"); firing {
+ t.Fatalf("a 57C SATA warning fired before its stability window")
+ }
+ m.CheckProxmoxDiskTemperature("lab", "pve1", ProxmoxDiskTemperatureReading{Disk: proxmoxTemperatureDisk("/dev/sdb", "sata"), Celsius: 70})
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/sdb"); !firing {
+ t.Fatalf("a 70C SATA critical reading waited out the stability window")
+ }
+}
+
+// A config save re-judges an open Proxmox disk temperature alert against its
+// disk type's trigger, as the next poll does; one without a recorded disk type
+// is held to the lowest per-type trigger.
+func TestProxmoxDiskTemperatureAlertsReevaluatePerDiskType(t *testing.T) {
+ m := newTestManager(t)
+ cfg := unifiedEvalBaseConfig()
+ cfg.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 70, Clear: 65}
+ configureUnifiedEvalManager(t, m, cfg)
+ m.CheckProxmoxDiskTemperature("lab", "pve1", ProxmoxDiskTemperatureReading{Disk: proxmoxTemperatureDisk("/dev/nvme0n1", "nvme"), Celsius: 72})
+ m.CheckProxmoxDiskTemperature("lab", "pve1", ProxmoxDiskTemperatureReading{Disk: proxmoxTemperatureDisk("/dev/sda", "sata"), Celsius: 57})
+ sata, ok := proxmoxDiskTemperatureAlert(t, m, "/dev/sda")
+ if !ok {
+ t.Fatalf("SATA at 57C did not fire: %v", alertKeys(m))
+ }
+
+ m.mu.Lock()
+ m.config.DiskTempByType["nvme"] = HysteresisThreshold{Trigger: 75, Clear: 70}
+ delete(sata.Metadata, "diskType")
+ m.reevaluateActiveAlertsLocked()
+ m.mu.Unlock()
+
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/nvme0n1"); firing {
+ t.Fatalf("NVMe alert at 72C survived a save raising its trigger to 75C")
+ }
+ if _, firing := proxmoxDiskTemperatureAlert(t, m, "/dev/sda"); !firing {
+ t.Fatalf("a SATA alert without a disk type was resolved by the 70C agent default although its trigger is 55C")
+ }
+}
diff --git a/internal/alerts/config/normalize.go b/internal/alerts/config/normalize.go
index 012cc63a33..5fd3214aa7 100644
--- a/internal/alerts/config/normalize.go
+++ b/internal/alerts/config/normalize.go
@@ -638,6 +638,10 @@ func NormalizeTimeThresholds(config *AlertConfig) {
ensureDelay("truenas-pool")
ensureDelay("truenas-dataset")
ensureDelay("truenas-disk")
+ // Proxmox disk temperature alerts: the factory stability window for a
+ // noisy gauge applies to this type's unchanged default, as it does to
+ // agent and TrueNAS disk temperatures.
+ ensureDelay("proxmox-disk")
ensureDelay("vmware-host")
ensureDelay("vmware-vm")
ensureDelay("vmware-datastore")
diff --git a/internal/alerts/config_runtime.go b/internal/alerts/config_runtime.go
index f0dbb81250..6af431cfbd 100644
--- a/internal/alerts/config_runtime.go
+++ b/internal/alerts/config_runtime.go
@@ -427,6 +427,19 @@ func (m *Manager) reevaluateActiveAlertsLocked() {
threshold = getThresholdForMetric(thresholds, metricType)
}
+ // A Proxmox disk temperature alert is judged by the disk temperature
+ // policy for its disk type, as CheckProxmoxDiskTemperature judges it.
+ // The node and guest policies below have no disk temperature, so a
+ // save would otherwise resolve an alert the next poll raises again.
+ if primaryResourceType == proxmoxDiskResourceType && metricType == proxmoxDiskTemperatureMetric {
+ diskType, known := alert.Metadata["diskType"].(string)
+ threshold = m.proxmoxDiskTemperatureThresholdNoLock(diskType, !known)
+ if threshold == nil || threshold.Trigger <= 0 {
+ alertsToResolve = append(alertsToResolve, alertID)
+ continue
+ }
+ }
+
isAgentResource := alertResourceTypeKeysContain(resourceTypeKeys, "agent")
if !handledModernPlatformType && isAgentResource {
if allDisabled, _ := m.alertPolicyTypeSwitchesNoLock("agent"); allDisabled {
diff --git a/internal/alerts/default_config.go b/internal/alerts/default_config.go
index 738e08a712..516756aaa8 100644
--- a/internal/alerts/default_config.go
+++ b/internal/alerts/default_config.go
@@ -150,6 +150,7 @@ func defaultAlertConfig() AlertConfig {
"truenas-pool": 5,
"truenas-dataset": 5,
"truenas-disk": 5,
+ "proxmox-disk": 5,
"vmware-host": 5,
"vmware-vm": 5,
"vmware-datastore": 5,
diff --git a/internal/alerts/proxmox_disk_temperature.go b/internal/alerts/proxmox_disk_temperature.go
new file mode 100644
index 0000000000..7aafd3e1c7
--- /dev/null
+++ b/internal/alerts/proxmox_disk_temperature.go
@@ -0,0 +1,110 @@
+package alerts
+
+import (
+ "fmt"
+ "strings"
+
+ "github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"
+ "github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
+ "github.com/rs/zerolog/log"
+)
+
+// proxmoxDiskTemperatureMetric is the metric of a Proxmox physical disk's
+// temperature alert, the same metric CheckHost raises for an agent's disks.
+const proxmoxDiskTemperatureMetric = "diskTemperature"
+
+// proxmoxDiskResourceType is the resource type PVE disk alerts carry in their
+// spec and metadata (see CheckDiskHealth).
+const proxmoxDiskResourceType = "proxmox-disk"
+
+// ProxmoxDiskTemperatureReading is one Proxmox physical disk's temperature as
+// the PVE disk poller judged it.
+type ProxmoxDiskTemperatureReading struct {
+ Disk proxmox.Disk
+ // Celsius is the reading collected this poll, or 0 when there is none:
+ // no sensor reports the disk, it is in standby, or normalization kept a
+ // last-known value it did not collect now.
+ Celsius int
+ // AgentOwned says a linked Pulse agent lists the disk in its SMART
+ // report, so the agent's CheckHost owns its temperature alert.
+ AgentOwned bool
+ // Excluded says the linked agent's --disk-exclude patterns match the
+ // device, which excludes it from disk alerts.
+ Excluded bool
+}
+
+// CheckProxmoxDiskTemperature raises a Proxmox physical disk's temperature
+// alert under the disk temperature policy (DiskTemperatureThreshold): the
+// same per-type thresholds that judge an agent's disks, TrueNAS disks and the
+// Physical Disks verdict. Without it a disk that only the node's sensors
+// report could read Running Hot and never alert.
+//
+// A disk a linked agent lists is the agent's: its open alert here closes as
+// moved to the agent rather than recovered, so the disk never alerts twice.
+// An excluded disk, or a policy switched off by the agent Disk Temp default,
+// closes its alert. A disk with no current reading keeps its alert as it is,
+// since no reading shows it cooled.
+func (m *Manager) CheckProxmoxDiskTemperature(instance, node string, reading ProxmoxDiskTemperatureReading) {
+ if m == nil {
+ return
+ }
+ disk := reading.Disk
+ resourceID := proxmoxDiskCanonicalResourceID(instance, node, disk.DevPath)
+ resourceName := fmt.Sprintf("%s (%s)", disk.Model, disk.DevPath)
+ diskType := strings.ToLower(strings.TrimSpace(disk.Type))
+
+ m.mu.RLock()
+ enabled := m.config.Enabled
+ threshold := m.proxmoxDiskTemperatureThresholdNoLock(diskType, false)
+ m.mu.RUnlock()
+ if !enabled {
+ return
+ }
+
+ if reading.AgentOwned || reading.Excluded || threshold == nil || threshold.Trigger <= 0 {
+ spec, err := buildCanonicalMetricSpec(resourceID, resourceName, unifiedresources.ResourceType(proxmoxDiskResourceType), proxmoxDiskTemperatureMetric, nil)
+ if err != nil {
+ return
+ }
+ var resolution *AlertResolution
+ if reading.AgentOwned && !reading.Excluded {
+ resolution = &AlertResolution{Reason: AlertResolutionMovedToAgent}
+ }
+ m.releaseCanonicalMetricAlert(spec, resourceName, node, instance, proxmoxDiskResourceType, 0, resolution)
+ return
+ }
+ if reading.Celsius <= 0 {
+ return
+ }
+
+ spec, err := buildCanonicalMetricSpec(resourceID, resourceName, unifiedresources.ResourceType(proxmoxDiskResourceType), proxmoxDiskTemperatureMetric, threshold)
+ if err != nil {
+ log.Warn().
+ Err(err).
+ Str("resourceID", resourceID).
+ Str("node", node).
+ Str("disk", disk.DevPath).
+ Msg("Skipping invalid canonical Proxmox disk temperature metric spec")
+ return
+ }
+ metadata := proxmoxDiskAlertMetadata(disk)
+ metadata["metric"] = proxmoxDiskTemperatureMetric
+ // A config save re-judges the open alert against its disk type.
+ metadata["diskType"] = diskType
+ value := float64(reading.Celsius)
+ m.checkMetricWithCanonicalSpec(spec, resourceName, node, instance, proxmoxDiskResourceType, value, threshold, &metricOptions{
+ Metadata: metadata,
+ Message: fmt.Sprintf("Disk temperature at %s", formatMetricValue(value, "°C")),
+ })
+}
+
+// proxmoxDiskTemperatureThresholdNoLock is the disk temperature policy for a
+// Proxmox disk of diskType, or the lowest per-type trigger for an alert whose
+// disk type was never recorded, so a config save never resolves an alert the
+// next poll raises again. Callers must hold m.mu.
+func (m *Manager) proxmoxDiskTemperatureThresholdNoLock(diskType string, typeUnknown bool) *HysteresisThreshold {
+ if typeUnknown {
+ return cloneThreshold(m.lowestHostDiskTemperatureThresholdNoLock(m.config.AgentDefaults.DiskTemperature))
+ }
+ return cloneThreshold(m.hostDiskTemperatureThresholdNoLock(m.config.AgentDefaults.DiskTemperature, false, diskType))
+}
diff --git a/internal/models/deepcopy_test.go b/internal/models/deepcopy_test.go
index 964ae44a28..e412d86406 100644
--- a/internal/models/deepcopy_test.go
+++ b/internal/models/deepcopy_test.go
@@ -1,6 +1,8 @@
package models
import (
+ "encoding/json"
+ "strings"
"testing"
)
@@ -512,3 +514,22 @@ func TestCloneHostXCPNGInventoryIsolation(t *testing.T) {
t.Fatal("cloned XCP-ng inventory aliases source VMs")
}
}
+
+// AgentSMARTReported is internal poll evidence: a state snapshot copy keeps it
+// for the alert check, and it never reaches an API or websocket payload.
+func TestPhysicalDiskAgentSMARTReportedStaysInternal(t *testing.T) {
+ disk := PhysicalDisk{ID: "lab-pve1-sda", DevPath: "/dev/sda", AgentSMARTReported: true}
+ if clone := clonePhysicalDisk(disk); !clone.AgentSMARTReported {
+ t.Fatalf("clone dropped AgentSMARTReported")
+ }
+ if clones := clonePhysicalDisks([]PhysicalDisk{disk}); !clones[0].AgentSMARTReported {
+ t.Fatalf("slice clone dropped AgentSMARTReported")
+ }
+ payload, err := json.Marshal(disk)
+ if err != nil {
+ t.Fatal(err)
+ }
+ if strings.Contains(strings.ToLower(string(payload)), "agentsmartreported") {
+ t.Fatalf("AgentSMARTReported leaked into JSON: %s", payload)
+ }
+}
diff --git a/internal/models/models.go b/internal/models/models.go
index 57d5733980..941020da7d 100644
--- a/internal/models/models.go
+++ b/internal/models/models.go
@@ -2766,7 +2766,11 @@ type PhysicalDisk struct {
IO *DiskIO `json:"io,omitempty"`
Collection *diskinventory.CollectionStatus `json:"collection,omitempty"`
ExpectedUpdateInterval time.Duration `json:"-"` // Collector schedule, independent of general node polling
- LastChecked time.Time `json:"lastChecked"`
+ // AgentSMARTReported marks a disk a linked host agent lists in its SMART
+ // report, so the agent's CheckHost owns its temperature alert. Internal
+ // poll evidence, set by the PVE disk poller's agent SMART merge.
+ AgentSMARTReported bool `json:"-"`
+ LastChecked time.Time `json:"lastChecked"`
}
// PBSInstance represents a Proxmox Backup Server instance
diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.go
index 25be288f63..c6b5171466 100644
--- a/internal/monitoring/monitor.go
+++ b/internal/monitoring/monitor.go
@@ -512,6 +512,7 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
// Build a map of node name to linked host's SMART data
smartByNodeName := make(map[string][]models.HostDiskSMART)
+ reportingNodeNames := make(map[string]bool)
for _, node := range nodes {
if node.LinkedAgentID == "" {
continue
@@ -521,6 +522,11 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
continue
}
smartByNodeName[node.Name] = host.Sensors.SMART
+ // Only an agent still reporting owns its disks' temperature alerts;
+ // a silent one's retained rows still enrich the disk.
+ if !strings.EqualFold(strings.TrimSpace(host.Status), "offline") {
+ reportingNodeNames[node.Name] = true
+ }
log.Debug().
Str("nodeName", node.Name).
Str("hostAgentID", node.LinkedAgentID).
@@ -607,6 +613,11 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
if matched == nil {
continue
}
+ // The linked agent reports this disk, so while it keeps reporting its
+ // CheckHost owns the disk's temperature alert and the PVE disk check
+ // stands aside. Once its lease lapses, CheckHost no longer alerts on
+ // the disk and the PVE check judges the node's own readings again.
+ updated[i].AgentSMARTReported = reportingNodeNames[updated[i].Node]
if strings.TrimSpace(updated[i].Model) == "" && strings.TrimSpace(matched.Model) != "" {
updated[i].Model = strings.TrimSpace(matched.Model)
diff --git a/internal/monitoring/monitor_pve.go b/internal/monitoring/monitor_pve.go
index 1e11c0b3d5..a063957263 100644
--- a/internal/monitoring/monitor_pve.go
+++ b/internal/monitoring/monitor_pve.go
@@ -10,6 +10,7 @@ import (
"sync"
"time"
+ "github.com/rcourtman/pulse-go-rewrite/internal/alerts"
"github.com/rcourtman/pulse-go-rewrite/internal/config"
"github.com/rcourtman/pulse-go-rewrite/internal/logging"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
@@ -1416,19 +1417,35 @@ func preserveUnavailablePhysicalDiskEvidence(current, previous models.PhysicalDi
return current
}
-// checkPhysicalDiskAlerts evaluates one Proxmox physical disk's health and
-// wearout alerts. A device matched by the linked host agent's --disk-exclude
-// patterns is evaluated as healthy, so excluding a disk also resolves the
-// alerts it already raised.
+// checkPhysicalDiskAlerts evaluates one Proxmox physical disk's health,
+// wearout and temperature alerts. A device matched by the linked host agent's
+// --disk-exclude patterns is evaluated as healthy and without a temperature
+// alert, so excluding a disk also resolves the alerts it already raised.
func (m *Monitor) checkPhysicalDiskAlerts(instance string, disk models.PhysicalDisk, excludePatterns []string) {
- if len(excludePatterns) > 0 && fsfilters.MatchesDeviceExclude(disk.DevPath, excludePatterns) {
+ excluded := len(excludePatterns) > 0 && fsfilters.MatchesDeviceExclude(disk.DevPath, excludePatterns)
+ if excluded {
healthyDisk := proxmoxDiskFromPhysicalDisk(disk)
healthyDisk.Health = "PASSED"
healthyDisk.Wearout = 100
m.alertManager.CheckDiskHealth(instance, disk.Node, healthyDisk)
- return
+ } else {
+ m.alertManager.CheckDiskHealth(instance, disk.Node, proxmoxDiskFromPhysicalDisk(disk))
}
- m.alertManager.CheckDiskHealth(instance, disk.Node, proxmoxDiskFromPhysicalDisk(disk))
+ m.alertManager.CheckProxmoxDiskTemperature(instance, disk.Node, alerts.ProxmoxDiskTemperatureReading{
+ Disk: proxmoxDiskFromPhysicalDisk(disk),
+ Celsius: collectedPhysicalDiskTemperature(disk),
+ AgentOwned: disk.AgentSMARTReported,
+ Excluded: excluded,
+ })
+}
+
+// collectedPhysicalDiskTemperature is the disk's temperature when this poll
+// collected it, or 0 for a last-known value normalization kept.
+func collectedPhysicalDiskTemperature(disk models.PhysicalDisk) int {
+ if !diskinventory.TemperatureCollected(disk.Temperature, disk.Collection) {
+ return 0
+ }
+ return disk.Temperature
}
func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {
diff --git a/internal/monitoring/physical_disk_roundtrip_test.go b/internal/monitoring/physical_disk_roundtrip_test.go
index c5b4bb4f93..8e5b0f4d20 100644
--- a/internal/monitoring/physical_disk_roundtrip_test.go
+++ b/internal/monitoring/physical_disk_roundtrip_test.go
@@ -1121,3 +1121,96 @@ func TestTrueNASPlaceholderDiskSerialsStayPerApplianceAndShareOneHistoryKey(t *t
t.Fatalf("canonical TrueNAS disks = %d, want %d (one per appliance and device)", disks, diskCount)
}
}
+
+// The agent SMART merge marks each Proxmox disk a reporting linked agent
+// lists, so the disk's temperature alert is left to the agent's CheckHost.
+// Disks the agent does not list, disks on nodes without an agent, and disks
+// of an agent whose lease lapsed stay unmarked. Disks the poller builds from
+// the agent's SMART report when the Proxmox query fails go through the same
+// merge.
+func TestMergeHostAgentSMARTIntoDisksMarksDisksTheAgentReports(t *testing.T) {
+ disks := []models.PhysicalDisk{
+ {Instance: "pve1", Node: "node1", DevPath: "/dev/sda"},
+ {Instance: "pve1", Node: "node1", DevPath: "/dev/sdb"},
+ {Instance: "pve1", Node: "node2", DevPath: "/dev/sda"},
+ {Instance: "pve1", Node: "node3", DevPath: "/dev/sda"},
+ }
+ nodes := []models.Node{
+ {Name: "node1", LinkedAgentID: "host-node1"},
+ {Name: "node2"},
+ {Name: "node3", LinkedAgentID: "host-node3"},
+ }
+ smart := []models.HostDiskSMART{{Device: "sda", Serial: "SER-SDA", Type: "sata", Temperature: 40}}
+ hosts := []models.Host{
+ {ID: "host-node1", Status: "online", Sensors: models.HostSensorSummary{SMART: smart}},
+ {ID: "host-node3", Status: "offline", Sensors: models.HostSensorSummary{SMART: smart}},
+ }
+
+ merged := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ for i, want := range []bool{true, false, false, false} {
+ if merged[i].AgentSMARTReported != want {
+ t.Fatalf("%s/%s AgentSMARTReported = %v, want %v", merged[i].Node, merged[i].DevPath, merged[i].AgentSMARTReported, want)
+ }
+ }
+ if disks[0].AgentSMARTReported {
+ t.Fatalf("merge modified the input slice")
+ }
+ if merged[3].Serial != "SER-SDA" {
+ t.Fatalf("a silent agent's retained row no longer enriches the disk: %+v", merged[3])
+ }
+
+ fallback := mergeHostAgentSMARTIntoDisks(physicalDisksFromHostAgentSMART("pve1", "node1", smart), nodes, hosts)
+ if len(fallback) != 1 || !fallback[0].AgentSMARTReported {
+ t.Fatalf("a disk built from a reporting agent's SMART report is not the agent's: %+v", fallback)
+ }
+}
+
+// checkPhysicalDiskAlerts raises a Proxmox disk's temperature alert from a
+// reading collected this poll, under the disk temperature policy, and leaves
+// alone a retained reading, a disk the linked agent reports and an excluded
+// device.
+func TestCheckPhysicalDiskAlertsRaisesProxmoxDiskTemperatureAlerts(t *testing.T) {
+ manager := alerts.NewManagerWithDataDir(t.TempDir())
+ m := &Monitor{alertManager: manager}
+ const instance, node = "pve1", "node1"
+ alertID := func(devPath string) string {
+ return unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, node, devPath) + "::metric-threshold:diskTemperature"
+ }
+ active := func(devPath string) bool {
+ for _, alert := range manager.GetActiveAlerts() {
+ if alert.ID == alertID(devPath) {
+ return true
+ }
+ }
+ return false
+ }
+ // 70C is critical for SATA (trigger 55, critical 65), which fires without
+ // the stability delay a warning waits out.
+ sata := func(devPath string) models.PhysicalDisk {
+ return models.PhysicalDisk{Instance: instance, Node: node, DevPath: devPath, Model: "Test SATA", Type: "sata", Health: "PASSED", Wearout: -1, Temperature: 70}
+ }
+
+ m.checkPhysicalDiskAlerts(instance, sata("/dev/sda"), nil)
+ if !active("/dev/sda") {
+ t.Fatalf("a SATA disk at 70C raised no temperature alert: %+v", manager.GetActiveAlerts())
+ }
+
+ retained := sata("/dev/sdb")
+ retained.Collection = &diskinventory.CollectionStatus{Temperature: diskinventory.Unavailable("proxmox_node_smart", "disk is in standby")}
+ m.checkPhysicalDiskAlerts(instance, retained, nil)
+ if active("/dev/sdb") {
+ t.Fatalf("a retained 70C reading raised a temperature alert")
+ }
+
+ agentOwned := sata("/dev/sdc")
+ agentOwned.AgentSMARTReported = true
+ m.checkPhysicalDiskAlerts(instance, agentOwned, nil)
+ if active("/dev/sdc") {
+ t.Fatalf("a disk the linked agent reports raised a second temperature alert")
+ }
+
+ m.checkPhysicalDiskAlerts(instance, sata("/dev/sdd"), []string{"sdd"})
+ if active("/dev/sdd") {
+ t.Fatalf("an excluded device raised a temperature alert")
+ }
+}
diff --git a/internal/unifiedresources/history_identity_test.go b/internal/unifiedresources/history_identity_test.go
index 03758b80bf..39d0ff5ce7 100644
--- a/internal/unifiedresources/history_identity_test.go
+++ b/internal/unifiedresources/history_identity_test.go
@@ -848,7 +848,7 @@ func TestProxmoxPhysicalDiskAlertReferenceShape(t *testing.T) {
ProxmoxPhysicalDiskAlertResourceID("lab", "pve1", "/"),
} {
require.True(t, isProxmoxPhysicalDiskAlertReference(ref), ref)
- require.Len(t, ProxmoxPhysicalDiskAlertIdentifiers(ref), 2, ref)
+ require.Len(t, ProxmoxPhysicalDiskAlertIdentifiers(ref), 3, ref)
}
for _, ref := range []string{
ProxmoxPhysicalDiskAlertResourceID("lab", "pve1", ""),
diff --git a/internal/unifiedresources/pve_disk_alert_history.go b/internal/unifiedresources/pve_disk_alert_history.go
index e2040b2eaf..b15afaeceb 100644
--- a/internal/unifiedresources/pve_disk_alert_history.go
+++ b/internal/unifiedresources/pve_disk_alert_history.go
@@ -26,6 +26,11 @@ const (
// "::" (buildCanonicalStateID over the spec ID).
var proxmoxDiskAlertSpecSuffixes = []string{"-health", "-wearout"}
+// proxmoxDiskTemperatureAlertSpecID is the PVE disk temperature alert's spec,
+// a metric threshold spec (canonicalMetricSpecID over "diskTemperature"), so
+// its identifier is "::metric-threshold:diskTemperature".
+const proxmoxDiskTemperatureAlertSpecID = "metric-threshold:diskTemperature"
+
// ProxmoxPhysicalDiskAlertIdentifiers lists the alert identifiers of the PVE
// disk alerts raised under ref, or nil when ref is not shaped like a PVE disk
// alert reference.
@@ -33,11 +38,11 @@ func ProxmoxPhysicalDiskAlertIdentifiers(ref string) []string {
if !isProxmoxPhysicalDiskAlertReference(ref) {
return nil
}
- identifiers := make([]string, 0, len(proxmoxDiskAlertSpecSuffixes))
+ identifiers := make([]string, 0, len(proxmoxDiskAlertSpecSuffixes)+1)
for _, suffix := range proxmoxDiskAlertSpecSuffixes {
identifiers = append(identifiers, ref+"::"+ref+suffix)
}
- return identifiers
+ return append(identifiers, ref+"::"+proxmoxDiskTemperatureAlertSpecID)
}
// isProxmoxPhysicalDiskAlertReference matches "::disk:"
diff --git a/internal/unifiedresources/store_test.go b/internal/unifiedresources/store_test.go
index 92ec4d333c..74649f8c83 100644
--- a/internal/unifiedresources/store_test.go
+++ b/internal/unifiedresources/store_test.go
@@ -14,6 +14,7 @@ import (
"github.com/rcourtman/pulse-go-rewrite/internal/models"
"github.com/rcourtman/pulse-go-rewrite/internal/operationreceipt"
+ "github.com/stretchr/testify/require"
)
func TestSQLiteResourceStoreDoesNotPersistRawOperationReceiptProtocolOrReplayAuthority(t *testing.T) {
@@ -3328,3 +3329,32 @@ func TestSuccessionMergesGuestChangeJournalEras(t *testing.T) {
t.Fatalf("legacy-era journal row missing from new-ID read: %+v", changes)
}
}
+
+// A PVE disk temperature alert row is owned by the hardware identity it
+// records, like the health and wearout rows, and a read by the path reference
+// still finds it through ProxmoxPhysicalDiskAlertIdentifiers.
+func TestProxmoxDiskTemperatureAlertRowsFollowRecordedHardwareIdentity(t *testing.T) {
+ store, err := NewSQLiteResourceStore(t.TempDir(), "default")
+ require.NoError(t, err)
+ t.Cleanup(func() { require.NoError(t, store.Close()) })
+ now := time.Now().UTC().Truncate(time.Second)
+ ref := ProxmoxPhysicalDiskAlertResourceID("lab", "pve1", "/dev/sda")
+ snapshot := proxmoxHistoryIdentitySnapshot(now)
+ snapshot.PhysicalDisks = []models.PhysicalDisk{pveDiskHistoryTestDisk("pve1", "/dev/sda", "ZA1A2B3C", "", now)}
+ adapter := NewMonitorAdapter(NewRegistry(store))
+ adapter.PopulateFromSnapshot(snapshot)
+ diskID, ok := adapter.currentRegistry().ResolveReferenceID(ref)
+ require.True(t, ok)
+
+ change := BuildAlertTimelineChange(ref, ChangeAlertFired, now, "", AlertTimelineChange{
+ AlertIdentifier: ref + "::metric-threshold:diskTemperature", AlertStartedAt: now, AlertType: "diskTemperature",
+ AlertMetadata: map[string]any{"disk_path": "/dev/sda", MetadataDiskSerial: "ZA1A2B3C", MetadataDiskWWN: ""},
+ })
+ change.ID = "temperature"
+ require.NoError(t, adapter.RecordChange(*change))
+
+ require.ElementsMatch(t, []string{"temperature"}, pveDiskHistoryIDs(pveDiskHistoryRows(t, store, diskID)))
+ byRef := pveDiskHistoryRows(t, store, ref)
+ require.ElementsMatch(t, []string{"temperature"}, pveDiskHistoryIDs(byRef))
+ require.Equal(t, ref, OwnedAlertReference(byRef["temperature"]))
+}
From b1fbee13385c3671808c9dbe30aa3ee2b6bd2150 Mon Sep 17 00:00:00 2001
From: rcourtman <8825017+rcourtman@users.noreply.github.com>
Date: Wed, 7 Oct 2026 17:02:17 +0100
Subject: [PATCH 3/3] Move TrueNAS re-judge tests clear of the cleanup tests
#2672 added its node cleanup tests right after TestCleanupAlertsForNodes,
where this branch had added its TrueNAS disk temperature re-judge tests,
so the branch no longer merged with main. Place the TrueNAS tests just
before TestCleanupAlertsForNodes instead; no test changes.
---
internal/alerts/alerts_test.go | 118 ++++++++++++++++-----------------
1 file changed, 59 insertions(+), 59 deletions(-)
diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.go
index 5dfafdca51..db48dfc08a 100644
--- a/internal/alerts/alerts_test.go
+++ b/internal/alerts/alerts_test.go
@@ -12300,6 +12300,65 @@ func TestCheckEscalations(t *testing.T) {
})
}
+// A config save re-judges open TrueNAS disk temperature alerts against the
+// threshold the next evaluation applies to each disk's type.
+func TestTrueNASDiskTemperatureAlertsReevaluatePerDiskType(t *testing.T) {
+ m := newTestManager(t)
+ cfg := unifiedEvalBaseConfig()
+ cfg.TrueNASDiskDefaults = ThresholdConfig{}
+ configureUnifiedEvalManager(t, m, cfg)
+
+ nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 72)
+ sata := trueNASTemperatureDisk("sda", "sata", 57)
+ checkTrueNASTemperatureDisk(t, m, nvme)
+ checkTrueNASTemperatureDisk(t, m, sata)
+ for _, disk := range []unifiedresources.Resource{nvme, sata} {
+ if _, firing := trueNASDiskTemperatureAlert(t, m, disk); !firing {
+ t.Fatalf("%s did not fire before the save: %v", disk.ID, alertKeys(m))
+ }
+ }
+
+ // Raising only the NVMe trigger resolves the NVMe alert and leaves the
+ // SATA alert, still over its own trigger, open.
+ m.mu.Lock()
+ m.config.DiskTempByType["nvme"] = HysteresisThreshold{Trigger: 75, Clear: 70}
+ m.reevaluateActiveAlertsLocked()
+ m.mu.Unlock()
+ if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); firing {
+ t.Fatalf("NVMe alert at 72C stayed open under a 75C NVMe trigger")
+ }
+ if _, firing := trueNASDiskTemperatureAlert(t, m, sata); !firing {
+ t.Fatalf("SATA alert at 57C resolved under its unchanged 55C trigger")
+ }
+}
+
+// An alert raised before it recorded its disk type is held to the lowest
+// per-type trigger, so a save never resolves an alert the next evaluation
+// raises again.
+func TestTrueNASDiskTemperatureAlertWithoutDiskTypeHeldAtLowestTrigger(t *testing.T) {
+ m := newTestManager(t)
+ cfg := unifiedEvalBaseConfig()
+ cfg.TrueNASDiskDefaults = ThresholdConfig{}
+ cfg.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 70, Clear: 65}
+ cfg.DiskTempByType = map[string]HysteresisThreshold{"nvme": {Trigger: 60, Clear: 55}}
+ configureUnifiedEvalManager(t, m, cfg)
+
+ nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 66)
+ checkTrueNASTemperatureDisk(t, m, nvme)
+ alert, firing := trueNASDiskTemperatureAlert(t, m, nvme)
+ if !firing {
+ t.Fatalf("NVMe at 66C did not fire under a 60C NVMe trigger: %v", alertKeys(m))
+ }
+
+ m.mu.Lock()
+ delete(alert.Metadata, "diskType")
+ m.reevaluateActiveAlertsLocked()
+ m.mu.Unlock()
+ if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); !firing {
+ t.Fatalf("an alert without a disk type was resolved by the 70C agent default although its NVMe trigger is 60C")
+ }
+}
+
func TestCleanupAlertsForNodes(t *testing.T) {
// t.Parallel()
@@ -12628,65 +12687,6 @@ func TestCleanupAlertsForNodes(t *testing.T) {
})
}
-// A config save re-judges open TrueNAS disk temperature alerts against the
-// threshold the next evaluation applies to each disk's type.
-func TestTrueNASDiskTemperatureAlertsReevaluatePerDiskType(t *testing.T) {
- m := newTestManager(t)
- cfg := unifiedEvalBaseConfig()
- cfg.TrueNASDiskDefaults = ThresholdConfig{}
- configureUnifiedEvalManager(t, m, cfg)
-
- nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 72)
- sata := trueNASTemperatureDisk("sda", "sata", 57)
- checkTrueNASTemperatureDisk(t, m, nvme)
- checkTrueNASTemperatureDisk(t, m, sata)
- for _, disk := range []unifiedresources.Resource{nvme, sata} {
- if _, firing := trueNASDiskTemperatureAlert(t, m, disk); !firing {
- t.Fatalf("%s did not fire before the save: %v", disk.ID, alertKeys(m))
- }
- }
-
- // Raising only the NVMe trigger resolves the NVMe alert and leaves the
- // SATA alert, still over its own trigger, open.
- m.mu.Lock()
- m.config.DiskTempByType["nvme"] = HysteresisThreshold{Trigger: 75, Clear: 70}
- m.reevaluateActiveAlertsLocked()
- m.mu.Unlock()
- if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); firing {
- t.Fatalf("NVMe alert at 72C stayed open under a 75C NVMe trigger")
- }
- if _, firing := trueNASDiskTemperatureAlert(t, m, sata); !firing {
- t.Fatalf("SATA alert at 57C resolved under its unchanged 55C trigger")
- }
-}
-
-// An alert raised before it recorded its disk type is held to the lowest
-// per-type trigger, so a save never resolves an alert the next evaluation
-// raises again.
-func TestTrueNASDiskTemperatureAlertWithoutDiskTypeHeldAtLowestTrigger(t *testing.T) {
- m := newTestManager(t)
- cfg := unifiedEvalBaseConfig()
- cfg.TrueNASDiskDefaults = ThresholdConfig{}
- cfg.AgentDefaults.DiskTemperature = &HysteresisThreshold{Trigger: 70, Clear: 65}
- cfg.DiskTempByType = map[string]HysteresisThreshold{"nvme": {Trigger: 60, Clear: 55}}
- configureUnifiedEvalManager(t, m, cfg)
-
- nvme := trueNASTemperatureDisk("nvme0n1", "nvme", 66)
- checkTrueNASTemperatureDisk(t, m, nvme)
- alert, firing := trueNASDiskTemperatureAlert(t, m, nvme)
- if !firing {
- t.Fatalf("NVMe at 66C did not fire under a 60C NVMe trigger: %v", alertKeys(m))
- }
-
- m.mu.Lock()
- delete(alert.Metadata, "diskType")
- m.reevaluateActiveAlertsLocked()
- m.mu.Unlock()
- if _, firing := trueNASDiskTemperatureAlert(t, m, nvme); !firing {
- t.Fatalf("an alert without a disk type was resolved by the 70C agent default although its NVMe trigger is 60C")
- }
-}
-
func TestCheckZFSPoolHealth(t *testing.T) {
// t.Parallel()