187 Commits

Author SHA1 Message Date
Richard Markiewicz 8232d12c55 feat(rdpeai): add native microphone capture (#2481)
Capture microphone audio through the RDPEAI dynamic channel and queue
outgoing packets with ordered control replies.

Expose polling and shutdown through the native audio session, and stop
capture if the bounded uplink overflows.
2026-11-23 18:06:51 +00:00
Richard Markiewicz e62f01c824 feat(ffi): add native audio playback (#2480)
Expose native RDPSND playback through the FFI and .NET bindings so
clients can play remote audio on a selected local output device.
Register static and dynamic playback channels, and join RDPDR without
redirected devices when it is absent so Windows servers can start
playback. Stop playback on demand or when the active stage is disposed.

Linux builds require ALSA development headers and the native library
requires `libasound` at runtime. Android retains its existing API
baseline and does not support native playback.
2026-11-20 12:11:04 -05:00
Richard Markiewicz 2064ca1c56 feat(ffi): expose direct dynamic virtual channels (#2476)
Let .NET clients use dynamic virtual channels without a named pipe.
Expose open, data, and close events with owned payloads and an endpoint
ID that prevents writes to a reopened channel from using a stale
endpoint. Encode outbound data and close requests through the existing
RDP session, without changing the pipe-proxy API.
2026-11-19 02:24:19 +00:00
Steven Downer 1abf001afc fix(ffi): map EnableFontSmoothing to the font smoothing flag (#2397)
PerformanceFlagsType::EnableFontSmoothing was mapped to
ENABLE_DESKTOP_COMPOSITION (0x100), so a client asking for font
smoothing through the bindings got desktop composition instead, and the
server drew text without smoothing. Only PerformanceFlags::new_default()
set font smoothing (0x80).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-15 09:31:14 -05:00
haefele-octoja 0a79fd2178 build(ffi): mark .NET bindings as AOT-compatible (#2426)
Native AOT and trimmed apps that reference `Devolutions.IronRdp` cannot
tell whether the bindings are safe for them, because the package does
not declare it. The bindings already are: the generated `Raw*` types use
plain `DllImport` calls with pointer and primitive arguments and
`[MarshalAs(UnmanagedType.U1)]` booleans, and `DiplomatWrite` takes
function pointers for two fixed delegate types, which Native AOT
supports.

Setting `IsAotCompatible` turns on the trim, AOT and single-file
analyzers for the project, so a later change that breaks AOT shows up as
a build warning, and marks the assembly as trimmable. The analyzers
report no warnings today.

Co-authored-by: haefele-octoja <267442939+haefele-octoja@users.noreply.github.com>
2026-11-12 14:28:31 -05:00
irvingouj@Devolutions b482f56c55 build(ffi): pin diplomat to Devolutions 0.17.0-devo.1 (#2353)
Moves the .NET bindings to Diplomat
[`0.17.0-devo.1`](https://github.com/Devolutions/diplomat/releases/tag/0.17.0-devo.1):
upstream 0.17.0 plus
[rust-diplomat/diplomat#1315](https://github.com/rust-diplomat/diplomat/pull/1315),
which keeps an argument alive when another argument may store it.

Nothing here stores an argument, so only the shared runtime files
(`BorrowLease.cs`, `RustHandle.cs`) change in the regenerated bindings.
No generated method changes.

Tested locally on Windows: regenerated bindings, .NET build and the .NET
tests pass.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-02 21:19:43 +00:00
Richard Markiewicz e0949e671e feat(ffi): expose RDPEI touch input (#2283)
Lets .NET consumers send touch and pen input over the MS-RDPEI dynamic
channel (`Microsoft::Windows::RDS::Input`), which the `ironrdp-rdpei`
crate and `ActiveStage` already implement but the FFI did not expose.

`ClientConnector.WithDynamicChannelRdpei(maxTouchContacts,
showTouchVisuals)` attaches the client, advertising protocol version 2,
which covers touch and pen. `TouchFrameBuilder` wraps
`rdpei::contact::TouchFrameBuilder` so toolkits push per-contact events
with a `TouchPhase` and desktop coordinates; `PenFrameBuilder` does the
same for one pen with a `PenPhase` (hovering, touching, out of range,
canceled) and optional `PenAttributes` (buttons, pressure, rotation,
tilt), both on the crate's contact state machine so contact ids,
`contactFlags` and frame timing are derived natively.
`ActiveStage.RdpeiInputState` reports what the channel accepts;
`ActiveStage.EncodeRdpeiTouch(builder)` and `EncodeRdpeiPen(builder)`
return the next frame to write, at most 32767 frames per call with the
remainder kept pending, or null when nothing is pending, and they throw
and keep the frames pending while the channel is not ready or suspended
or the event fails to encode.
`ActiveStage.EncodeRdpeiDismissHovering(contactId)` encodes
`RDPINPUT_DISMISS_HOVERING_CONTACT_PDU`.

Multipen injection is not requested, so pen frames use `deviceId` 0. The
.NET smoke tests open the channel against scripted DRDYNVC and SC_READY
PDUs and decode the encoded touch, pen and dismiss-hovering PDUs against
MS-RDPEI 2.2.3.3, 2.2.3.7 and 2.2.3.6, including the split of more than
32767 pending frames.
2026-10-29 01:27:45 +00:00
Richard Markiewicz 4982320bff perf(ffi): size PDUs from the header and add buffered, sync and cancellable Framed reads (#2289)
`Framed.ReadPdu` copied the whole buffer into a new array on every
`FindSize` call. An active-stage PDU announces its length in its first
bytes (four for TPKT, at most three for fast-path), so `Framed` now
probes only the first four buffered bytes into a reusable array;
`ReadByHint` keeps the full copy because connection-time PDUs are few
and small.

New members, alongside the existing ones:

- `ReadPdu(CancellationToken)`, and `CancellationToken` overloads of
`ReadExact` and both `ReadByHint`.
- `TryReadBufferedPdu(out (Action, byte[]))`: takes the next PDU when it
is already buffered, without reading the stream, so a consumer can flush
rendering only when nothing more is pending.
- `ReadPduSync()`: a blocking read for a dedicated read thread.

A cancelled read stops waiting but leaves the stream read in flight; the
next read, asynchronous or synchronous, finishes it first, so bytes are
neither lost nor read twice. Every read reports a stream that ends
before the PDU is complete as `IronRdpLibException(EndOfFile)`, where
`ReadExact` and `ReadByHint` threw a plain `Exception`.

`Connection.Connect`,
`RDCleanPathConnection.ConnectRDCleanPath`/`ConnectVmConnectRDCleanPath`
and `Connection.SingleSequenceStep` take an optional `CancellationToken`
and pass it to the hint reads, the TCP connect and the TLS handshake.

Consumers:

- The Avalonia example cancels the connection sequence and the read loop
through one token on window close or session end, and uses
`TryReadBufferedPdu` to present the bitmap only once no further PDU is
buffered, so a burst of updates draws once.
- `ConnectExample` uses the cancellable read with a timeout instead of
`Task.WhenAny`, which left a read pending.
- Devolutions/IronSessions `RdpSession` uses `TryReadBufferedPdu` to
flush rendering only when the socket is quiet,
`ReadPdu(CancellationToken)` for disconnect and timeout, the cancellable
`ReadByHint` during the connection sequence, and `ReadPduSync` for a
dedicated read thread on Mono (Android/iOS), where awaiting every read
hopped pool threads. `ReadPduSync` has no consumer in this repository on
purpose: the examples are async end to end.

`ffi/INTENT.md` records the probe width, the `ReadByHint` split, the EOF
policy and the read regime.

Smoke tests cover header-only sizing for TPKT and both fast-path length
encodings, several PDUs in one read, a partial PDU left buffered, the
sync read across split reads, EOF inside a PDU body on every read path,
and a cancelled read whose in-flight stream read the next read finishes.
2026-10-28 20:35:17 -04:00
Richard Markiewicz cd6c224335 feat(ffi): encode fast-path input without the active stage (#2288)
`ActiveStage.ProcessFastpathInput` was the only way for a .NET client to
turn input events into wire bytes, and it takes the stage and the image,
so input handlers had to share the lock that the PDU decode loop holds.
On a busy screen the UI thread waited on frame decoding for every mouse
move.

Encoding needs no session state:
`ironrdp_session::encode_fastpath_input` chunks the events into
Fast-Path Input PDUs, and `ActiveStage::process_fastpath_input` reuses
it, so its output is unchanged. The .NET binding exposes it as
`FastPathInputEventIterator.Encode()`, which returns the PDUs for one
`InputDatabase.Apply` as a `VecU8` ready for `Framed.Write`, without
touching an `ActiveStage` or `DecodedImage`. `ProcessFastpathInput`
stays for clients with software pointer rendering, which also redraws
the pointer in the image.

The Avalonia example sends input through `Encode()` unless software
pointer rendering is on, and the README states which calls no longer
need the stage lock.
2026-10-28 16:48:50 -04:00
Richard Markiewicz 851747a1c7 feat(ffi): expose display control readiness and capabilities (#2285)
`ActiveStage.EncodedResize` returns `null` until the Display Control
channel has received the server's capabilities, and the .NET binding
gave a client no way to tell when that happens, so clients polled or
retried blindly.

Add `ActiveStage.DisplayControlState` (`Unavailable`, `Pending`,
`Ready`) and `ActiveStage.DisplayControlCapabilities` (`MaxNumMonitors`,
`MaxMonitorArea`), wrapping
`ironrdp_session::ActiveStage::display_control_ready` and
`display_control_capabilities`. A client checks the state after each
`Process` call and sends its first resize once it becomes `Ready`.

`display_control_ready` now takes `&self`, which Diplomat requires for a
getter; it never needed `&mut self`.
2026-10-28 19:49:35 +00:00
Richard Markiewicz 3c196765a4 feat(ffi): expose preconnection PDU encoding (#2284)
Add `PreconnectionBlob` to the .NET bindings with `NewV1(id)`,
`NewV2(id, payload)` and `Encode()`, so a client can write an MS-RDPEPS
preconnection PDU on the TCP stream before the X.224 Connection Request
without hand-rolling the wire format. Gateways and Hyper-V VMConnect
listeners select the RDP source from this PDU; a plain Windows 3389
listener does not accept one.

The encoder is `ironrdp_pdu::pcb::PreconnectionBlob`, so cchPCB counts
the UTF-16 null terminator and `Encode()` returns the bytes as an owned
`VecU8`. The type is not `IDisposable` because it is a small value-like
object.
2026-10-28 19:48:39 +00:00
irvingouj@Devolutions 27b8a31df6 chore(release): prepare for Devolutions.IronRdp v2026.10.28.0 (#2282)
Bumps the NuGet package to **2026.10.28.0** (package `2026.10.28`), same
as #2146.

Heads up, this one's breaking for .NET callers: the bindings moved to
Diplomat 0.16 (#2165) and now hand back owned data instead of borrowed
views (#2167). It also ships RemoteFX on by default (#2242) and the
render/`Framed` perf work (#2168, #2169, #2170).

After merge, publish with the **Publish NuGet package** workflow
(`workflow_dispatch`, dry-run = false).

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-28 15:28:42 -04:00
irvingouj@Devolutions a495fbc369 perf(ffi): redraw only the damaged rectangle (#2170)
On every graphics update the Avalonia example allocated a full-frame
array, copied the whole framebuffer into it, cleared the whole bitmap
and copied the whole frame again. It ignored the rectangle that the
update reports.

Copy just that rectangle with `CopyRectInto` into a buffer kept across
frames, under the stage lock. Then copy it into the bitmap using the
bitmap's real row length. The whole frame is copied only when the image
size changes, and the bitmap is recreated outside the lock. A failed
render now logs why.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

---------

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-28 18:37:30 +00:00
irvingouj@Devolutions cf40ba53e8 perf(ffi): stop reallocating on every Framed read (#2169)
`Framed` created a native `IronRdpPdu` on every `ReadPdu` loop, a new
array on every socket read, and rebuilt its whole remaining buffer with
LINQ after every PDU.

Create one `IronRdpPdu` per `ReadPdu` call instead of one per loop. Keep
one read buffer per `Framed`, append the bytes read as a span, and drop
consumed bytes with `RemoveRange`.

The buffer list is now updated in place, so `GetInner` returns the live
buffer rather than a snapshot that later reads replace.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

---------

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Co-authored-by: Marc-André Moreau <mamoreau@devolutions.net>
Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-28 14:19:52 -04:00
irvingouj@Devolutions 3e42406f76 perf(ffi): copy only the damaged rectangle (#2168)
C# callers could only read the framebuffer whole, so every graphics
update copied the full frame even when a few pixels changed. The update
already says which rectangle changed.

Add `DecodedImage.CopyRectInto(rect, buffer, stride)`. It copies the
rows of that rectangle into the caller's buffer at the same position,
without allocating. Inverted rectangles, rectangles past the image and
short buffers return an error instead of panicking.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

---------

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Co-authored-by: Marc-André Moreau <mamoreau@devolutions.net>
Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-28 13:41:31 -04:00
thebigjoe1 ab029ff7d1 feat(connector)!: let the client choose the RDP version it announces (#2115)
Let clients choose the RDP version announced in GCC Client Core Data
through `ironrdp_connector::Config::rdp_version` and
`ironrdp_client::config::ConfigBuilder::with_rdp_version`.
The builder defaults to `RdpVersion::V5_PLUS`, preserving existing
behavior.
Relative mouse input still raises the announced version to at least RDP
10.12, as required by [MS-RDPBCGR sections 2.2.1.3.2 and
2.2.7.1.6](https://learn.microsoft.com/en-us/openspecs/windows_protocols/ms-rdpbcgr/b3bc76ae-9ee5-454f-b197-ede845ca69cc),
without lowering a newer configured version.

Update the Progressive reset test to the current tile helper signature
so workspace tests compile after rebasing.

BREAKING CHANGE: `ironrdp_connector::Config` gains a public
`rdp_version` field. Existing struct literals should set it to
`RdpVersion::V5_PLUS` to preserve behavior.

---------

Co-authored-by: Marc-André Moreau <mamoreau@devolutions.net>
Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-27 20:27:25 -04:00
irvingouj@Devolutions d28a214c94 fix(ffi)!: return owned data, not borrowed views (#2167)
`DecodedImage`, `DecodedPointer` and `ActiveStageOutput` own the
framebuffer, the pointer bitmap and response payloads, which are large
native allocations the garbage collector does not see. That is the first
condition in `ffi/INTENT.md` for being `IDisposable`. They handed out
views that borrow from them, which the new .NET generator refuses for
disposable types, and every caller copied the bytes into a managed array
right away anyway.

- `ActiveStageOutput.ResponseFrame`/`WindowingOrders` and
`DecodedPointer.Data` return an owned `VecU8`, which has the same
`Size`/`Fill` members as the old view.
- `DecodedImage.Data` is replaced by `DataSize` and `FillData(byte[])`.
They copy the framebuffer once into the caller's buffer, and a larger
buffer is fine.

The three types are now `IDisposable`, and `ffi/README.md` lists them.
The Avalonia example disposes the image it replaces on reactivation, and
both examples dispose each output and response frame they read.

BREAKING CHANGE: `DecodedImage.Data` is removed, use `DataSize` and
`FillData`. `ResponseFrame`, `WindowingOrders` and `DecodedPointer.Data`
now return `VecU8` instead of `BytesSlice`.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

---------

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Co-authored-by: Marc-André Moreau <mamoreau@devolutions.net>
Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-27 11:22:16 -04:00
irvingouj@Devolutions d69ab8cc60 perf(ffi): offer RemoteFX when no bitmap config is set (#2242)
`ConfigBuilder.build()` always passed `bitmap: None`
([config.rs](https://github.com/Devolutions/IronRDP/blob/0de13342/ffi/src/connector/config.rs#L231)),
so .NET clients never offered a codec and the server fell back to
near-raw bitmaps. On a 1080p video-like load that's ~6.5 MB a frame, and
the server just starts skipping frames ("insufficient network").

Now, when no bitmap config is set, `build()` uses the same default as
the native client: 32-bit, lossy, default codecs (RemoteFX here, since
the FFI doesn't build QOI). A config set through `bitmap_config` is used
instead of being ignored.

Lab numbers (IT-HELP-AGENT → IT-HELP-DC, Avalonia example, video-like
load, frame rate from the server's `RemoteFX Graphics` counters,
1024x768 VM, 5 alternating runs each):

| | master | this PR |
|---|---|---|
| server output fps (median) | 12.8 | 18.7 |
| frames skipped/s, network | 3.0 | 0 |
| bandwidth | 23.8 MB/s | 5.6 MB/s |
| client VM CPU | 33.6% | 14.1% |

Also checked the screen by eye: desktop text and the video pattern both
render fine.

Not in here on purpose: bulk compression and EGFX, those are follow-ups.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-26 21:01:51 -04:00
irvingouj@Devolutions e3affd83c5 build(ffi)!: move to Diplomat 0.16.1-devo.2 (#2165)
The .NET bindings were generated by Diplomat 0.7 from a personal fork,
years behind upstream. Move to the protected `Devolutions/diplomat` tag
that IronVNC and picky-rs already use, with the same xtask pinning and
install flow.

Rust side:
- pin `diplomat` and `diplomat-runtime` to tag `0.16.1-devo.2` and drop
the `[patch.crates-io]` entry for the old fork; its zero-length slice
fix is upstream now, since slice parameters go through `DiplomatSlice`,
which maps a null pointer to an empty slice
- `opaque_mut` on the 20 types that are mutated through `&mut`, named
lifetimes on borrowed returns, `DiplomatWriteable` renamed to
`DiplomatWrite`, and no explicit `Clone`/`Copy` on bridge enums
- move `dotnet-interop-conf.toml` to the `lib_name` + `[dotnet]` layout

Tooling: xtask installs `diplomat-tool` from the tag with Rust 1.96.0,
because the tag does not build with the workspace toolchain. It records
the source and version so a tool from another tag is never reused,
checks that the tool and the ffi crate use the same tag, and calls the
tool by absolute path. The `ffi` CI job caches those records with the
binary, so a cache hit does not reinstall the tool.

The library and examples use properties instead of the removed
`GetX()`/`SetX()` methods.

`ffi/README.md` gains a migration section with these steps.

BREAKING CHANGE: for consumers of `Devolutions.IronRdp`:
- `GetX()`/`SetX()` methods that duplicated a property are removed
- the `&mut` getters on `ClientConnectorState` and
`CredsspSequenceInitResult` are methods only
- `IronRdpErrorKind.IO` and `WrongOS` are now `Io` and `WrongOs`
- `Position`, `MultitransportRequest` and `NetworkCharacteristics` are
structs with public fields instead of classes with properties
- the `Devolutions.IronRdp.Raw` namespace is internal, and the public
`AsFFI()` methods and raw-pointer constructors are removed
- `DiplomatWriteable`, `DiplomatOpaqueException` and the
`IronRdpError.ToDisplay(DiplomatWriteable)` overload are removed
- `IronRdpException` is no longer `partial`
- only the ten types listed in `ffi/README.md` are `IDisposable`; every
other type, such as `Config`, `InclusiveRectangle` and
`ClientConnector`, is released by its finalizer and no longer has
`Dispose()`
- overlapping calls on one native object now throw, such as calling
`ActiveStage` from the PDU loop and an input handler at once, or using a
`CredsspSequence` while its `CredsspProcessGenerator` is alive

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-26 13:12:48 -04:00
Marc-André Moreau 98413f16cc feat(activex)!: broaden mstscax compatibility (#2211)
Hosts written against Microsoft's mstscax control (RDM, MsRdpEx,
scripting hosts, mstsc-style shells) still hit members that IronRDP's
ActiveX control left unimplemented. A comparison against mstscax.dll
10.0.26100 (its embedded MSTSCLib type library, AdvancedSettings vtable
and property handlers) identified the most-used gaps; this change closes
six of them.

Late-bound Automation: every published MSTSCLib member of the control
and of the Advanced, Secured, Transport and RemoteProgram settings
objects is reachable through `IDispatch` by name and DISPID, with
arguments coerced to the published Automation types and calls routed to
the existing vtable slots through `DispCallFunc`. The control also
implements `IProvideClassInfo2`, `IQuickActivate` and
`IPersistPropertyBag`/`IPersistPropertyBag2`. No type library is created
or registered, so `GetTypeInfo` still returns `E_NOTIMPL`.

Events: the control raises `OnRequestContainerMinimize`, `OnLogonError`,
`OnUserNameAcquired`, `OnNetworkStatusChanged`,
`OnRemoteProgramDisplayed`, `OnRemoteWindowDisplayed`,
`OnIdleTimeoutNotification`, `OnFocusReleased` and
`OnMouseInputModeChanged` with mstscax's argument layout, and the modern
facade gains `OnNetworkStatusChanged` and `OnKeyCombinationPressed`.
Events without an IronRDP source stay unraised and are documented.

Keyboard and input policy: the `HotKey*` and focus-release hotkeys,
`AcceleratorPassthrough`, `SasSequence`, `DisableCtrlAltDel`,
`DoubleClickDetect` and `RelativeMouseMode` follow mstscax defaults, and
the extended properties `AllowRelativeMouseMode`,
`IgnoreServerGeneratedMouseMoves`, `IgnoreClientSideMouseInput`,
`DisableFullScreenHotkey` and `AllowSasSequenceTransmission` are
honored. Relative pointer input is sent only when the server's Input
Capability Set allows it, and the client then advertises
`RNS_UD_CS_RELATIVE_MOUSE_INPUT` with RDP version 10.12, the lowest
version for which servers honor it.

AdvancedSettings compatibility: deprecated slots that mstscax answers
with `S_FALSE` now do the same instead of failing with `E_NOTIMPL`, and
`overallConnectionTimeout`, `singleConnectionTimeout`,
`shutdownTimeout`, `MinutesToIdleTimeout` and `CanAutoReconnect` are
wired to the client.

Extended settings and `.rdp` properties: `IMsRdpExtendedSettings`
accepts the mstscax names that map to IronRDP behavior (desktop and
device scale, physical size and orientation, selected monitors, audio
devices, location, touch, manual clipboard sync, `RemoteSessionId` and
others) and documents the rest. The connector can advertise physical
size, orientation, device scale and Client Monitor Extended Data (only
when it describes every monitor of Client Monitor Data), and the `.rdp`
mapping reads `session bpp`, `devicescalefactor`, `connection type`,
`redirectsmartcards` and `redirectlocation`.

`IMsRdpClientShell` and publisher trust: `MsRdpClientShell` returns a
working `.rdp` record store. Its `Launch` applies the records to the
owning control and connects in-process instead of starting `mstsc.exe`,
subject to the `DisableClientLaunchingFromActiveXControl` policy.
`ApplySettings` verifies signed `.rdp` files with the Windows client's
format and policies, and `ShowRedirectionWarningDialog`,
`RedirectionWarningType`, `WarnAboutPrinterRedirection`,
`LaunchedViaClientShellInterface` and `PublisherCertificateChain` drive
a fail-closed consent prompt before connecting. A signed file whose
signature no longer matches is rejected, where Windows downgrades it to
an unverifiable publisher.

Save Session Info logon errors now decode NTSTATUS failure types
([MS-RDPBCGR] 2.2.10.1.1.4.1.1), which previously ended the session with
a decode error, and relative mouse fast-path events now carry their
body. The FFI reports the new session outputs as
`ActiveStageOutputType::LogonErrors` (17) and
`ActiveStageOutputType::SessionId` (18), after the existing
`WindowSurfaceUpdates` (15) and `ServerRedirection` (16).

🤖 Generated with [Claude Code](https://claude.com/claude-code)

BREAKING CHANGE: `ironrdp_session::ActiveStageOutput` and
`ironrdp_session::x224::ProcessorOutput` gain `LogonErrors` and
`SessionId` variants; `ironrdp_client::rdp::RdpOutputEvent` gains
`ServerInputFlags`, `LogonError`, `NetworkCharacteristics` and
`RemoteSessionId` variants; `ironrdp_connector::Config` and
`ironrdp_client::config::ChannelConfig` have new public fields;
`ironrdp_pdu::rdp::session_info::LogonErrorNotificationType` gains an
`NtStatus(u32)` variant and is no longer `#[repr(u32)]`.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-23 17:30:58 -04:00
Marc-André Moreau 6e54d5e9ec feat(egfx)!: composite surfaces mapped to RemoteApp windows (#2197)
With the graphics pipeline in a RemoteApp session, Windows servers
present each application window from its own surface through
MapSurfaceToWindow or MapSurfaceToScaledWindow (MS-RDPEGFX 2.2.2.20 and
2.2.2.23). The client only forwarded these PDUs to handler callbacks, so
nothing those surfaces drew reached the windows.

The compositor now records window mappings and, at each EndFrame,
materializes dirty regions of window-mapped surfaces into window
updates: the RAIL window ID, the presented size and the changed region
in window coordinates, scaled when the server asks for a different
target size. GraphicsPipelineClient::drain_window_updates exposes them,
the session emits ActiveStageOutput::WindowSurfaceUpdates and the client
forwards RdpOutputEvent::WindowSurfaceUpdates. A mapping the client
cannot present, such as a mapped area larger than its surface, is
ignored and the surface keeps its previous mapping; FreeRDP also refuses
oversized mappings.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

BREAKING CHANGE: ActiveStageOutput and RdpOutputEvent have a new
WindowSurfaceUpdates variant, and the .NET ActiveStageOutputType enum
gains WindowSurfaceUpdates.

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-23 15:20:50 -04:00
Marc-André Moreau f5ec943588 fix(pdu)!: tolerate icon flags without an icon in window orders (#2210)
The typed windowing order decoder rejected a window order that set
WINDOW_ORDER_FIELD_ICON_BIG or ICON_OVERLAY without an icon or cached
icon. Those flags carry no data and only qualify an icon, the previous
validator tolerated them, and a decode error ends the session, so such
an order from a server now disconnected the client.

The decoder ignores the two flags when no icon is present and decodes
the order as a window state order. The complete slow-path Orders update
framing, including its updateType field, moves into ironrdp-pdu as
encode_slow_path_windowing_orders_update and
slow_path_windowing_orders_update_size, which the .NET binding and the
daemon's RAIL event byte count now share. The Orders update is cited as
MS-RDPBCGR 2.2.9.1.1.3.1 with MS-RDPEGDI 2.2.2.1.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

BREAKING CHANGE: encode_slow_path_windowing_orders and
slow_path_windowing_orders_size are replaced by
encode_slow_path_windowing_orders_update and
slow_path_windowing_orders_update_size, which include updateType.

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-23 11:27:09 -04:00
Marc-André Moreau 485657a6ec feat!: follow server redirection to the target host (#2208)
An RD Connection Broker sends a Server Redirection PDU to move a client
to the session host that holds or will hold its session. IronRDP
rejected the PDU as an unexpected share control PDU, so a client could
not connect to an RDS farm through its broker.

The PDU layer decodes and encodes the Server Redirection Packet with
every optional field, the target net addresses and the Base64 target
certificate container, in both its Enhanced Security variant (share
control type PDUTYPE_SERVER_REDIR_PKT) and its Standard Security
variant. The Client Info PDU can carry an opaque password cookie
verbatim, as FreeRDP sends it.

The connector recognizes the PDU during capabilities exchange and
connection finalization and ends in a `Redirected` state instead of
failing; `connect_finalize` returns a `ConnectionOutcome` that is either
`Connected` or `Redirected`. The session reports a redirection received
later as `ActiveStageOutput::ServerRedirection`. PDUs marked
LB_NOREDIRECT are ignored.

`ironrdp-client` now always advertises redirection support in the Client
Cluster Data and follows a redirection for every front-end: it closes
the connection, emits `RdpOutputEvent::ServerRedirected` and reconnects
with the load-balancing information as the X.224 routing token, the
session ID in the cluster data, the password cookie in the Client Info
PDU and the redirected user name and domain. Transport, TLS and CredSSP
settings are kept. A direct connection tries the target addresses first,
like mstsc, and authenticates the FQDN; `use redirection server name`
(ActiveX `UseRedirectionServerName`) or a gateway puts the names first.
A target certificate reported by the broker is accepted under strict
validation, a TsvUrl mismatch aborts, and at most 8 redirections are
followed. RDSTLS-encrypted passwords are refused as unsupported.

`ironrdp-server` gains a redirection handle that sends the PDU to the
active client and waits for it to disconnect, and reports the routing
token, redirected session ID and password cookie of an incoming
connection. The FFI exposes the redirection outcome to .NET.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-23 09:58:33 -04:00
Marc-André Moreau 2bc793ef3f feat(pdu)!: decode RemoteApp windowing orders into typed structs (#2195)
Windowing Alternate Secondary Drawing Orders (MS-RDPERP 2.2.1.3) were
only validated and forwarded as raw bytes, so every RemoteApp front-end
re-parsed them by hand and ignored what it did not parse: icons, cached
icons, window shapes, visibility regions, notification icons, the active
window and the z-order.

ironrdp-pdu now decodes each order into a typed WindowOrder,
NotifyIconOrder or DesktopOrder, including TS_ICON_INFO and
TS_CACHED_ICON_INFO, and encodes them back. ActiveStageOutput and the
client's RdpOutputEvent carry the decoded orders instead of a slow-path
update. The ActiveX control consumes the typed orders in place of its
own parser, and the .NET binding still exposes a slow-path Orders update
by re-encoding them.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

BREAKING CHANGE: ActiveStageOutput::WindowingOrders and
RdpOutputEvent::WindowingOrders now hold Vec<WindowingOrder>, and the
ironrdp_pdu::window decoding functions return owned typed orders.

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-23 09:20:17 -04:00
irvingouj@Devolutions 18ec4a045e refactor(ffi): mark the IDisposable bridge types (#2164)
The Diplomat version we are moving to makes `IDisposable` opt-in.
Without the attribute, a generated wrapper only has a finalizer.

Mark the types that `ffi/INTENT.md` says are disposable:
- operating-system resources: `ActiveStage`, whose DVC pipe proxies own
named-pipe worker threads, and `WinCliprdr`, which owns the clipboard
window
- large buffers the garbage collector cannot see:
`ActiveStageOutputIterator`, `VecU8`, `WriteBuf`, and the clipboard
payloads `ClipboardMessage`, `ClipboardSvcMessage`, `FormatDataResponse`
and `FfiFileContentsResponse`

`DvcPipeProxyMessage` stays unmarked: sending one moves its payload out,
so nothing large is left behind.

Also mark `CredsspProcessGenerator`. None of the three conditions names
it, but it holds `&mut` of its `CredsspSequence`, and the sequence
rejects every other call until the generator is released. Releasing it
costs nothing.

`DecodedImage`, `DecodedPointer` and `ActiveStageOutput` also qualify,
but they hand out borrows that outlive the call, which the new generator
refuses for disposable types; a later change returns owned data so they
can be marked too.

The pinned 0.7 macro strips `#[diplomat::attr]`, so this changes no
generated code.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-22 21:51:20 -04:00
Marc-André Moreau b9d1400033 feat(cliprdr): transfer files through the Windows clipboard (#2179)
Adds clipboard file transfer, in both directions, to the Windows
clipboard backend (`WinClipboard`), and stops it advertising formats it
can't deliver. ActiveX and `ironrdp-client` get the feature as is; the
.NET FFI gets it through new bindings, opt-in.

## Backend (`feat(cliprdr)`)

**Remote to local.** When the remote format list has
`FileGroupDescriptorW`, an OLE data object goes on the clipboard
(`OleSetClipboard`). It offers `FileGroupDescriptorW` and one
`FileContents` `IStream` per file (`lindex`), plus the other remote
formats.
- Streams read through `FileContents` RANGE requests carrying the
`clipDataId` of the lock `Cliprdr` took for that list, so a paste keeps
working after the remote clipboard changes, until the lock is released.
Files over 4 GiB work.
- OLE needs an STA: this is only enabled when `WinClipboard` is created
on one. COM is never initialized on a thread that has none.
- The objects are not agile and run on the clipboard thread. A stream
read blocks it like `WM_RENDERFORMAT` handling already does (30 s
timeout, chunks up to 1 MiB with read-ahead). Backend events arriving
during a wait are now queued instead of dropped.

**Local to remote.** `CF_HDROP` paths (directories walked into relative
paths), or another application's virtual files (`FileGroupDescriptorW` +
`FileContents`), are offered with `SendInitiateFileCopy` once the
channel is ready. The remote's SIZE/RANGE requests are served, from the
lock snapshot when a `clipDataId` is given.

**Capabilities.** The backend now negotiates `STREAM_FILECLIP_ENABLED`,
`FILECLIP_NO_FILE_PATHS`, `CAN_LOCK_CLIPDATA` and
`HUGE_FILE_SUPPORT_ENABLED`.

**Format filtering.** Handle-based formats (`CF_BITMAP`,
`CF_ENHMETAFILE`, `CF_METAFILEPICT`, `CF_PALETTE`), private ranges,
local paths and shell items (`CF_HDROP`, `FileNameW`, `Shell IDList
Array`) and OLE storage formats are no longer advertised in either
direction. Images still go through as `CF_DIB`, which Windows
synthesizes.

**Request validation.** `ironrdp-client` treats a rejected clipboard
request as session-fatal, so the backend checks what it sends against
the rules `Cliprdr` enforces: file list indexes, range bounds, huge-file
positions, and released locks.

**Also fixed.** The window subclass state leaked on drop, and
`WM_DESTROY` freed it while `WM_NCDESTROY` could still use it.

## Viewer (`fix(viewer)`)

Without a backend factory, `ironrdp-client` created `WinClipboard` on
the RDP thread, which runs a tokio runtime and no Windows message loop,
so clipboard redirection never worked in the viewer (no clipboard
events, no backend wake-ups, no STA for OLE). The viewer now initializes
OLE and creates the clipboard, with file transfer, on its winit thread
and hands the factory to `RdpClient`.

## .NET FFI (`feat(ffi)`)

- `ActiveStage.SubmitClipboardMessage` hands any backend message to the
clipboard channel, file transfer included, and returns the frame to
send.
- `ActiveStage.DriveClipboardTimeouts` expires clipboard locks and file
transfers.
- `WinCliprdr.NewWithFileTransfer(bool)` opts in. `WinCliprdr.New()`
keeps file transfer off, so existing consumers that only route the three
original message types don't receive new ones.
- `WinCliprdr.NextClipboardMessageTimeout(ms)` lets a loop wake up to
drive the timeouts.
- The Avalonia example opts in, submits every message through
`SubmitClipboardMessage`, drives the timeouts, and logs a failed
clipboard operation instead of stopping clipboard handling.

Only the four affected generated files are included.

## Testing

- `cargo xtask check fmt`, `check lints` and `check locks` pass.
- 12 unit tests in `cliprdr_native::windows`: format filtering, file
list building, file contents serving, range sizing, descriptor
round-trips.
- 6 tests in `cliprdr_native::windows_live` run a `CliprdrClient` over
`WinClipboard` against an in-memory `CliprdrServer` on the real Windows
clipboard. They are opt-in with `IRONRDP_WIN_CLIPBOARD_LIVE=1`, because
they replace the clipboard and briefly open an Explorer window. All pass
locally:
- Explorer pastes remote folders and files, contents checked byte for
byte.
  - A 5 GiB remote file is read through OLE past 4 GiB.
  - Remote handle and path formats are not offered locally.
- Local folders reach the remote, both at connect time and when copied
mid-session.
  - Local image formats are filtered.
  - Virtual files from another session reach the remote.
- .NET: the solution builds and the smoke tests pass (9/9, one new).

- End to end with `ironrdp-viewer` against a Windows 11 server
(rdpclip): capabilities negotiated as `STREAM_FILECLIP_ENABLED |
FILECLIP_NO_FILE_PATHS | CAN_LOCK_CLIPDATA | HUGE_FILE_SUPPORT_ENABLED`.
A local folder (nested directories, an empty directory, an empty file, a
5 MiB random file) copied in Explorer was pasted into Explorer in the
session, served under rdpclip's lock. Copying it back in the session and
pasting it into a local Explorer window gave byte-identical files
(SHA-256).

Not verified by hand: ActiveX and the Avalonia example against a real
server.

## Notes for review

- This conflicts with #2175 in `MainWindow.axaml.cs` and the generated
`ActiveStage` files. The clipboard loop body here is a single
`SubmitClipboardMessage` call, so the merge only needs #2175's
`WithActiveStage(...)` wrapper around it; the generated files can be
regenerated.
- Running the extra test suite locally may need `CMAKE` pointed at
Visual Studio 2026's bundled CMake: `libopus_sys` fails with older CMake
versions that lack the "Visual Studio 18 2026" generator.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-22 08:47:03 -04:00
Marc-André Moreau b735d190dd feat(ffi): redirect smartcards through WinSCard on Windows (#2175)
## Problem

`ClientConnector.WithStaticChannelRdpdr` in the .NET FFI announces a
smartcard device backed by `NoopRdpdrBackend`. That backend's
`handle_scard_call` returned no messages, so the client never completed
any MS-RDPESC IOCTL the server sent (EstablishContext, ListReaders,
GetStatusChange, ...). Server-side WinSCard calls in the session hung,
which can stall logon and UAC prompts that check for readers.
`ironrdp-client` attaches the same backend when RDPDR is enabled with no
native backend.

## Fix

**The noop backend answers every smartcard call.** It replies with the
return structure the server expects for that IOCTL, with `ReturnCode =
SCARD_E_NO_SERVICE` and `IoStatus = STATUS_SUCCESS`, as MS-RDPESC 3.1.4
requires for smart card errors. Shared helpers in `ironrdp-rdpdr` build
these replies, and the Windows backend now uses them too:

- `ScardCall::error_response` builds the completion for a failed call.
An IOCTL with no known return structure gets `STATUS_UNSUCCESSFUL` and
no output, as in FreeRDP; this path is unreachable today.
- `esc::complete_call` replies `STATUS_BUFFER_TOO_SMALL` when the
structure does not fit the server's output buffer, so the server retries
with a larger one (3.2.5.2).
- Error returns zero every field besides `ReturnCode` (2.2.3): empty
context and handle (`ScardContext::empty`, `ScardHandle::empty`), NULL
buffers, and no reader states (kept on `SCARD_E_TIMEOUT`, as FreeRDP
does). This also fixes failure replies in the Windows backend (Connect,
Transmit, Reconnect, GetTransmitCount, GetDeviceTypeId).

**Real WinSCard redirection in the FFI on Windows.**
`WithStaticChannelRdpdr` now backs the smartcard with the WinSCard
passthrough from `ironrdp-rdpdr-native`, the same backend the viewer and
ActiveX use. Other platforms keep the noop backend.

The native backend runs blocking calls (GetStatusChange, Connect,
Transmit, ...) on worker threads, and their completions only reach the
server through `Rdpdr::poll_deferred_messages`. So:

- `ActiveStage.Process` sends deferred RDPDR completions after each
frame, as `ironrdp-client` does, except after `DeactivateAll` or
`Terminate`.
- New `ActiveStage.PollRdpdrDeferred()` returns them while the server is
idle. Hosts should call it about every 50 ms, serialized with their
other `ActiveStage` calls.
- The Avalonia example polls every 50 ms from its read loop, and starts
the next read only after the current frame's outputs are handled, so
reactivation reads are not raced.

The existing .NET API is unchanged; `PollRdpdrDeferred` is an addition.
The regenerated bindings only add the new method and doc comments.

## Related PRs

This PR builds on #2161 and #2162, both now merged into master:

- #2161 makes `Framed.Write` safe for concurrent writers, which the
example's 50 ms poll relies on.
- #2162 locks every `ActiveStage` call in the Avalonia example. This PR
only adds the RDPDR poll, the read-ordering fix and a null guard in
`SendFastpath` on top of it.

## Testing

- Testsuite tests send an EstablishContext IOCTL through `Rdpdr` with
the noop backend, cover the `STATUS_BUFFER_TOO_SMALL` and no-structure
paths, and check that error replies for eight call types are all zero
after `ReturnCode`.
- `cargo test` passes for `ironrdp-rdpdr`, `ironrdp-rdpdr-native` and
the testsuite's rdpdr tests.
- `cargo xtask check fmt`, `cargo xtask check locks`, `cargo xtask ffi
build` and `cargo xtask ffi bindings` (which builds the .NET library)
pass, and the Avalonia example builds.
- Clippy with `-D warnings` is clean on `ironrdp-rdpdr`,
`ironrdp-rdpdr-native`, `ironrdp-testsuite-core` and `ffi`. The full
`cargo xtask check lints` could not run locally because the
`libopus_sys` CMake build fails on that machine.

Not tested: a live session with a reader and card, and building the FFI
for non-Windows targets (left to CI).

🤖 Generated with [Claude Code](https://claude.com/claude-code)

---------

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 22:49:12 -04:00
irvingouj@Devolutions 5a088293c9 refactor(ffi): annotate Diplomat accessors (#2163)
The Diplomat version we are moving to no longer turns `get_*`/`set_*`
methods into C# properties from a config prefix. Each accessor needs its
own attribute, or the property silently disappears from the bindings.

Annotate every accessor that the current bindings expose as a property:
86 getters and 19 setters. The nine `&mut self` getters are left as
methods, because the new generator refuses getters that take `&mut
self`.

The pinned 0.7 macro strips `#[diplomat::attr]`, so this changes no
generated code.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-21 15:37:54 +00:00
irvingouj@Devolutions db0a45a03c fix(ffi): lock ActiveStage in the Avalonia example (#2162)
The example calls into `ActiveStage` and `DecodedImage` from the PDU
loop, the clipboard loop and the UI thread without any lock, so two
`&mut` borrows of the same native object can be live at once. The next
Diplomat runtime turns this into an "Another borrow is already active"
exception, which would end the session loop.

Take one lock around each native call on the stage or the image, through
a `WithStageLock` helper, and route the five input handlers through one
`SendFastpath` helper. The lock is never held across an `await` or a
dispatcher call, so it cannot deadlock with the UI thread.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-21 15:37:53 +00:00
irvingouj@Devolutions 549fc050dc fix(ffi): use an async lock for Framed writes (#2161)
`Framed.Write` held a `Mutex` across `await _stream.WriteAsync(...)`.
That broke in three ways:
- A `Mutex` must be released by the thread that took it. Without a
synchronization context, the code after the `await` can run on another
thread, so `ReleaseMutex` threw `ApplicationException`.
- A `Mutex` lets its owning thread enter again, so two writes started
from one thread were not serialized at all.
- `WaitOne` blocked the calling thread, such as the Avalonia UI thread,
while another thread held the lock.

Use a `SemaphoreSlim` with `WaitAsync`, which has no thread affinity, is
not re-entrant, and does not block a thread while it waits.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-21 11:05:12 -04:00
irvingouj@Devolutions 3a3c27d3a8 fix(ffi): dispose CredSSP generator before reuse (#2160)
`ProcessTsRequest` returns a generator that holds an exclusive borrow of
the CredSSP sequence. The CredSSP loop left it alive and then called
`HandleProcessResult` on the same sequence, so two `&mut` borrows of it
were live at once.

Dispose the generator as soon as it has produced the client state.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-20 17:34:52 -04:00
irvingouj@Devolutions a1d824f0ea fix(ffi): stop panicking on larger output buffers (#2159)
`VecU8`, `BytesSlice` and `U32Slice` checked that the output buffer was
not too small, then called `copy_from_slice` on the whole buffer. Any
buffer larger than the data passed the check and panicked, which aborts
the host process across the FFI boundary. `WriteBuf.ReadIntoBuf` had no
check at all: a larger buffer panicked the same way, and a shorter one
silently got only the start of the data.

Copy into the front of the buffer, leave the rest untouched, and fail
when the buffer is too small. The four methods now share one
`fill_prefix` helper.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-20 17:34:51 -04:00
irvingouj@Devolutions 8aa19d03ef test: add .NET smoke tests for the FFI bindings (#2158)
The .NET bindings had no runtime test, only a compile check. Upcoming
Diplomat work changes how the generated wrappers hold native handles, so
a regression would only show up in a consumer app.

Add a small console test runner, in the same style as IronVNC's, that
exercises the bindings without a network: image data, byte buffers,
error mapping, PDU sizing, config validation, and the first X.224
exchange of the connector. Run it in the FFI CI job.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-20 17:34:51 -04:00
irvingouj@Devolutions aa237eb6a0 docs(ffi): define .NET binding intent (#2157)
The Diplomat version we are moving to makes `IDisposable` opt-in per
opaque type and rejects overlapping calls that mutate an object, so the
bindings need rules for disposal and concurrency.

Adopt the disposal rule IronVNC already follows: a type is `IDisposable`
only when it owns a large allocation the garbage collector cannot see, a
scarce or externally observable resource, or a borrowing view of a
disposable type. Also record that no opaque type with a lifetime touches
borrowed data when dropped, since .NET finalizers run in no
deterministic order. These two sections are a verbatim copy of IronVNC
`ffi/src/INTENT.md` at 5c3ea3d5.

Add a concurrency section: the generated code rejects only overlapping
calls that mutate an object, the hand-written layer locks fragile places
such as `Framed`, and otherwise a consumer makes one call at a time on
each native object.

The file sits in `ffi/` so it covers both the Rust bridge and the C#
layer under `ffi/dotnet/`. It states where the bindings are going, not
where they are: some of today's code does not follow it yet, and
follow-up changes bring that code in line.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>

Co-authored-by: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-20 16:48:16 -04:00
Marc-André Moreau df977e1206 fix(ffi): invert no_audio_playback mapping in connector config (#2172)
`ConfigBuilder::build` in the FFI copied `no_audio_playback` straight
into `enable_audio_playback`, so setting "no audio playback" to true
enabled playback and false disabled it.

The mapping is now inverted (`!no_audio_playback.unwrap_or(false)`).
When the flag is set, `INFO_NOAUDIOPLAYBACK` is sent in the Client Info
PDU, asking the server not to play audio on the client. The default
(field unset) is unchanged: playback enabled.

The FFI currently exposes no setter for this field, so the bug was
latent; this fixes the mapping ahead of any setter being added. No unit
test: the `ffi` crate has no config-building test pattern.

Checks: `cargo xtask check fmt` and `cargo clippy -p ffi --all-targets
-- -D warnings` pass.

🤖 Generated with [Claude Code](https://claude.com/claude-code)

Co-authored-by: Claude Sonnet 5.5 <noreply@anthropic.com>
2026-10-20 16:24:15 -04:00
AKolenda 9be90a7674 feat(session)!: answer bandwidth measurements during the session (#2012)
The session answered RTT requests on the message channel but ignored
continuous Bandwidth Measure Start and Stop. A shared
`AutoDetectResponder` now answers them.

- A continuous reliable Start opens or resets a window. Received TCP
frames contribute their complete length when no RDP Security Header is
present, including fast-path and TPKT/X224/MCS framing. Where a Security
Header is present, only bytes following it count.
- Results use the measured elapsed time with a 1 ms floor and saturating
counters. A missing or untimed window returns 1 ms and zero bytes.
- Connect-time requests belong to the connection sequence handled by
`ironrdp-connector` and are ignored here. Lossy-tunnel requests are not
answered on the main connection.

BREAKING CHANGE: `ActiveStage::process` and `x224::Processor::process`
take a `received_at: Option<MonotonicInstant>` argument, matching
`ironrdp_connector::Sequence::step`. Pass the time the transport read
the frame, such as `Framed::last_read_at()`; with `None`, bandwidth
results report 0 kbps. The native client, web client, FFI and examples
pass their arrival time.

Co-authored-by: AKolenda <testedemail2222@gmail.com>
Co-authored-by: Benoît CORTIER <git.divisible626@passmail.com>
Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-20 14:24:07 +09:00
Richard Markiewicz d4c2fec346 chore(release): prepare for Devolutions.IronRdp v2026.10.19.0 (#2146)
Bumps the NuGet package version to **2026.10.19.0** (package
`2026.10.19`), as in #1048.

First package since 2025.12.4 to ship:
- the `ios-arm64` + `iossimulator-arm64` framework slices with
single-slice selection (9d206a3d) — 2025.12.4's fat `runtimes/ios`
binary had no arm64-simulator slice;
- the run-time iOS framework resolver (#2145).

After merge, publish with the **Build and publish** workflow
(`workflow_dispatch`, dry-run = false).

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-19 19:21:04 +00:00
Richard Markiewicz b81c7e3bbb fix(ffi): resolve the iOS framework at run time (#2145)
## Problem

The generated raw layer declares a bare
`[DllImport("DevolutionsIronRdp")]`. iOS is the only target that ships
the native code inside a framework bundle rather than a loose dylib, and
no default probing permutation resolves a path inside one, so P/Invoke
binding fails with a `DllNotFoundException` whose entire message is
`DevolutionsIronRdp`.

This is invisible under full AOT, which emits direct native calls and
never probes. It fails wherever binding happens at run time: the
simulator's JIT and any consumer running with `UseInterpreter=true`.

## Change

- **`NativeLibraryResolver.cs`** (new, hand-written outside
`Generated/`, which `cargo xtask ffi` wipes) - registers a
`DllImportResolver` for this assembly via `[ModuleInitializer]`, so
consumers need no setup. Gated to iOS; tries the framework's `@rpath`
install name, then the absolute path under the app bundle's
`Frameworks/`, then falls back to `GetMainProgramHandle()` for the
statically-linked / already-loaded case. That fallback probes a known
export first, so a genuinely missing library is still reported as a
`DllNotFoundException` naming it rather than as a per-symbol
`EntryPointNotFoundException` from an unrelated call later.
- `CA2255` (module initializers in libraries) is suppressed with
justification: the DllImports are spread across the generated `Raw*`
types with no shared static-constructor chokepoint, and requiring
consumers to call an initializer is the coupling this removes.

No packaging/CI change: master already ships `ios-arm64` +
`iossimulator-arm64` as separate frameworks with single-slice selection
(#9d206a3d) — that just hasn't been released since 2025.12.4, whose
`runtimes/ios` fat binary is arm64-device + x86_64-simulator only and
cannot load on an Apple-silicon simulator.

## Verification

Built both slices locally (`aarch64-apple-ios`, `aarch64-apple-ios-sim`
with the simulator `SDKROOT`, `production-ffi` profile), bundled them as
frameworks exactly as the workflow does, packed `Devolutions.IronRdp`
from this branch, and referenced it from an Avalonia iOS app
(`net10.0-ios`, `iossimulator-arm64`, `UseInterpreter=true`) on an
iPhone 16 Pro simulator:

```
[ironrdp-probe] bare-name TryLoad (expected False): False
[ironrdp-probe] FFI call succeeded: IronRDP native library loaded via Devolutions.IronRdp resolver
```

(`ConfigBuilder.New()` → `Build()` executes Rust code, including its
config validation.) No device available here; the device slice is the
same code path under AOT, which never probes.

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-10-19 14:21:46 -04:00
Suresh Kumar Ramu 62246b364a build(connector)!: update sspi to 0.23 and picky to rc.26 (#2080) 2026-10-16 03:46:02 -04:00
GlassOnTin 5bdb67980c feat(connector)!: expose SUPPORT_DYN_VC_GFX_PROTOCOL early-cap flag for EGFX clients (#1237)
Currently, `early_capability_flags` in the GCC core data is built from a
fixed set in `connection.rs`. Clients that want to use the Graphics
Pipeline Extension (MS-RDPEGFX) — by attaching a `DvcClientProcessor`
for `Microsoft::Windows::RDS::Graphics` — have no way to set
`SUPPORT_DYN_VC_GFX_PROTOCOL` without forking the connector, and modern
Windows servers won't open the EGFX channel unless the client advertises
support.

This PR adds an opt-in `Config.support_dyn_vc_gfx_protocol: bool`
(default `false`). When set, the flag is OR'd into
`early_capability_flags` alongside the existing `WANT_32_BPP_SESSION`
conditional. Existing consumers are unaffected; the doc comment includes
a safety note that setting this without an EGFX implementation will
cause Windows to stop sending legacy bitmap updates, leaving the desktop
blank.

Used downstream by [Haven](https://github.com/GlassHaven/Haven) (an
Android RDP/VNC client) which implements EGFX with ClearCodec +
RemoteFxProgressive decoders; this lets us drop a vendored fork of
`ironrdp-connector` we currently carry just for this one flag.

Default `false` to preserve current behaviour. `cargo check --workspace`
clean — six other in-tree `Config { … }` builders updated with the
default-false field.

---------

Co-authored-by: Marc-André Moreau <mamoreau@devolutions.net>
2026-08-30 07:04:01 -04:00
Greg Lamberson 36a848e085 fix(connector)!: count the auto-detect header, and only answer connect-time (#1559)
## Summary

- The Network Characteristics Byte Count store was incremented by the
payload length alone, so every counted Bandwidth Measure message was
reported 8 bytes short.
- [MS-RDPBCGR] 3.2.5.14 says to increment it "by the value specified in
the **payloadLength** field plus the size of the header fields (8
bytes)", on each Bandwidth Measure Payload and on the 0x002B Stop.
2.2.14.1.3 pins that 8 by requiring `headerLength` to be 0x08.
- The Start and Stop arms now check the request type rather than
matching every variant.

## Those two increments are the whole of the connect-time byte count

Worth stating, because 3.2.5.14 also contains a rule that counts every
byte received while a window is open, and it's easy to assume it applies
here.

It doesn't. That rule belongs to the 0x0014 and 0x0114 Starts, which are
the reliable and lossy UDP variants. Connect-time is 0x1014, and its
step list says only to clear the stores and start the timer. So on this
path the Payload and Stop increments are the entire count, and no
framing-layer accumulation is needed.

## Why the request-type check is required, not tidying

2.2.14.1.4 sets `headerLength` to 0x08 for the 0x002B Stop and 0x06
otherwise. A fixed 8-byte addend is therefore only correct once the type
is known, which makes the check part of the byte-count fix rather than
separate from it.

It has two further effects that are worth having. A continuous-detection
Start no longer opens a connect-time window, and a continuous Stop is no
longer answered with a connect-time result on the main channel when
3.2.5.14 routes those to a multitransport channel under a different
procedure. That procedure also requires a sequence-number correlation on
the 0x0629 Stop which this phase does not track, so ignoring is the
conservative response.

This overlaps the automated reviewer's fifth finding on #1530, which
suggested exactly this narrowing. I'd offered there to fold it into that
PR or take it separately; the conditional header size settled it, since
the byte count is wrong without it.

## This is deliberately not FreeRDP's arithmetic

FreeRDP counts the whole PDU length at the framing layer,
`bandwidthMeasureByteCount += length` in `libfreerdp/core/rdp.c` after
`rdp_read_header`, for any window including connect-time, and then adds
`payloadLength` again in `libfreerdp/core/autodetect.c` for the Payload
and the Stop. On the connect-time path that counts the payload twice and
adds framing bytes the spec doesn't ask for.

I went with the spec rather than the reference here. The reported figure
is an informational QoS hint and the server proceeds on receipt either
way, so there's no interop cost to being correct. The divergence is
called out in a comment at the helper so nobody later "fixes" it toward
FreeRDP.

## Depends on #1530

Stacked. #1530 introduces the bandwidth window state
(`connect_time_bw_started_at`, `connect_time_bw_bytes`) that this counts
into; on master there's nothing to accumulate. The branch carries
#1530's commits, so it builds and tests on its own, and the merge order
is #1530 then this.

Because it carries them, the diff shown here is cumulative. This pull
request's own change is 3 files, +180/-21:
`crates/ironrdp-connector/src/connection.rs`,
`crates/ironrdp-connector/src/lib.rs` and one connector test. The size
label is computed on the cumulative diff, so it counts #1530's four
commits too.

Raised by the automated reviewer on #1530, where the prescribed fix is
the arithmetic used here.

## The reported byte count is measurement-gated

Worth stating for consumers, because it is a deliberate deviation.
3.2.5.14 states the Bandwidth Measure Payload increment unconditionally.
Here the Payload bytes are accumulated only while a window is open,
which means a driver that reports no arrival times never counts them and
its Results carry the Stop's own payload alone against the untimed
floor.

A full count paired with a `timeDelta` the client never measured yields
a bandwidth figure that grows with whatever the server chose to send, so
this under-reports rather than over-reports. The practical consequence
is that a server acting on 3.3.5.14 will pick conservative
bandwidth-dependent settings for such a client. Of the drivers in tree
only the FFI connector is in that position.

## Breaking changes

Two, both in `ironrdp-connector`, and `cargo semver-checks -p
ironrdp-connector --baseline-rev master` reports exactly these two and
nothing else:

- `Sequence::step` takes a third parameter, `received_at:
Option<MonotonicInstant>`. This breaks every external implementor and
every caller of the trait. `step_no_input` keeps its signature and
passes `None`.
- `ClientConnector` gains two private fields,
`connect_time_bw_started_at` and `connect_time_bw_bytes`, so the struct
is no longer constructible by literal downstream.

The clock stays in the driver because a sequence must not read one,
which is what keeps the sans-I/O invariant intact. A defaulted trait
method would avoid the signature break but would let an implementor
override only the old entry point and silently never receive an arrival
time, so the required parameter is the safer of the two.

## Validation

- `cargo xtask check fmt/lints/tests/typos/locks` all pass on the pinned
toolchain, plus `cargo xtask wasm check`, with `fuzz/` built before the
lock check.
- Four existing expectations move by exactly 8 per counted message: 3584
to 3608 (two Payloads and a Stop), 512 to 520 (one Stop), and two at
1536 to 1552 (a Payload and a Stop each), the second of which is the
window-reset test #1530 added after this branch was first filed. A
fifth, 4096 to 4104, went with the redundant test #1530 dropped in
review.
- Two tests added for the guards: continuous Start, Payload and Stop
produce no reply and leave the phase running; and a connect-time Stop
arriving after a continuous Start reports the untimed floor against its
own payload alone, since the continuous Start opened no window.
- Eleven connect-time auto-detect tests pass.
2026-08-19 20:57:27 -04:00
Greg Lamberson 6a499faece feat(connector)!: pass frame arrival time into Sequence::step (#1530)
## Summary

- Connect-time bandwidth measurement needs to know when bytes arrived,
and nothing in the sans-I/O layer could tell it. #1465, now merged,
answers the server's Bandwidth Measure Stop with a nominal interval for
exactly that reason: the connector has no way to observe the real one.
- Introduce `MonotonicInstant`, a millisecond counter with an arbitrary
epoch, and make `Option<MonotonicInstant>` a required parameter of
`Sequence::step`. The I/O drivers already know when a read completed, so
`Framed` records the arrival time of each read and hands it to the state
machine. A driver with no clock passes `None`.
- With arrival times available, measure for real: a Bandwidth Measure
Start opens a window, Payload messages accumulate their byte counts, and
Stop reports the elapsed time between its own arrival and the Start's.

#1465 has merged, so this applies directly to master and carries no
merge-order dependency. That PR was the FreeRDP unblock on its own; this
is the design change behind it, split out at @CBenoit's suggestion in
review.

## Why the clock lives in the driver

Two reasons, both of which rule out having the sequence read a clock
itself.

`std::time::Instant::now` panics on `wasm32-unknown-unknown`, and
`ironrdp-connector` compiles for it. `ironrdp-web` reaches
`ironrdp-async` through `ironrdp-futures`, so the clock read is `cfg`'d
there too: the wasm arm returns `None` rather than panicking on the
first socket read.

More fundamentally, a sequence that timestamps its own entry measures
how fast it drained an already-filled buffer, not how long the bytes
took to arrive. `Framed` stamps the actual socket read, so a PDU served
entirely from `buf` correctly reports the read that filled it.

## Why the parameter is an Option

Three situations look alike at the Stop and are not alike, and
collapsing them produces a worse figure than the nominal one #1465
sends.

A Stop with no preceding Start has no window to time. A window whose
Start, Payload and Stop arrived in one socket read carries the same
instant on all three, so the elapsed time rounds down to zero; TCP
coalescing makes this the common case on a fast link, because the
connect-time payload is small. And a driver with no clock reports
nothing at any point, which is not a measurement of zero but the absence
of one.

Only the middle case is a measurement. Making the parameter
`Option<MonotonicInstant>` is what keeps it distinguishable: a window
opens only when the Start carried a reading, so a driver with no clock
opens none, accumulates nothing, and answers the Stop with its own
payload alone. A window that was timed reports every byte per
[MS-RDPBCGR] 3.2.5.14, including when the elapsed time floors to 1 ms,
because the bytes really did arrive inside that millisecond.

Both untimed cases report a 1 ms floor rather than 0, since a server
computing `byteCount * 8 / timeDelta` divides by it.

There is no `MonotonicInstant::ZERO`. An earlier revision used it as
both the clock's origin and the "did not measure" sentinel, which is
precisely what made the wasm32 and FFI drivers indistinguishable from a
fast link: they would have paired a full byte count with an interval the
client never measured, and the reported bandwidth would have grown with
however much payload the server chose to send.

## Breaking change

`Sequence::step` takes an `Option<MonotonicInstant>`. Implementors must
add the parameter; callers driving a sequence by hand must supply an
arrival time or switch to `step_no_input`, which passes `None` for them.
All 8 in-tree implementors and the call sites across `ironrdp-acceptor`,
`ironrdp-async`, `ironrdp-blocking`, `ironrdp-client`, `ironrdp-web` and
`ffi` are updated here. `Framed::last_read_at` returns
`Option<MonotonicInstant>`.

## MonotonicInstant now lives in ironrdp-core

Also folded in here: ironrdp-rdpeudp independently defined its own
MonotonicInstant, identical in spirit to this PR's but not in API (it
carries as_millis and saturating_add, this one didn't), so a reading
from one driver could never be handed to the other. Issue #140 asked for
these to converge on one type in ironrdp-core, which both crates already
depend on.

Moved the fuller rdpeudp version into ironrdp-core and re-exported it
from both existing paths. Not filed separately: there was nothing to
migrate out of ironrdp-connector until this PR introduced its copy, so
this is the first point where the duplication exists to fix. No call
site outside the two definitions changes, both
ironrdp_connector::MonotonicInstant and
ironrdp_rdpeudp::MonotonicInstant keep working unchanged, and it's
non-breaking on its own (the connector's version gains
as_millis/saturating_add/Add<Duration>, which it didn't have before).

## Stacked on this

#1559 is stacked on this pull request and carries its three commits, so
the merge order is this one then #1559. Landing this shrinks #1559's
diff to its own change, 2 files and +149/-15 in `connection.rs` plus one
connector test.

#1559 counts the 8-byte auto-detect header into the byte count
introduced here, and narrows the Start and Stop arms to the connect-time
request type. Both come from the automated reviewer's findings on this
pull request.

## Why this is one PR

The automation flags this as size/XL and asks for it to be split. The
three commits here do not separate into reviewable pull requests.

The first changes the `Sequence::step` signature, and every implementor
and caller moves with it: connector, acceptor, async, blocking, client,
web, the FFI and the tests. That is 19 of the 23 files and +474/-116 on
its own, and a pull request holding the trait change without them does
not build.

The second exists because of the review on the first. It distinguishes a
window that was never timed from one measured as zero, which is the fix
for the finding that a wasm or FFI client would otherwise report a
fabricated bandwidth. Splitting it out means filing the first commit
with a defect already raised against it.

The third is the tests for both.

Stacked pull requests are the remedy the note suggests, and it adds that
they require every branch to live in this repository. This branch is on
a fork, so that path is closed.

## Validation

- `cargo xtask check fmt/typos/lints/tests/locks` all pass on the pinned
toolchain, `fuzz/` built before the lock check.
- `cargo xtask wasm check` passes. Worth stating separately: this is the
gate that catches the `Instant::now` hazard above, since the workspace
default target never compiles that crate for wasm.
- Six new tests in
`crates/ironrdp-testsuite-core/tests/connector/autodetect.rs`: the
interval and byte count match what the driver observed across a
Start/Payload/Stop window; several Payload messages accumulate across a
timed window; a window delivered in one read floors the interval with
every byte still counted; a driver reporting no arrival times answers
with the Stop payload alone; a Stop with no preceding Start is answered
with the floor; and a second Start clears both stores and restarts the
timer, which 3.2.5.14 requires and which nothing else covered.
- Four more in a new
`crates/ironrdp-testsuite-core/tests/async_framed.rs` covering
`Framed::last_read_at` itself, since the tests above feed
`Sequence::step` hand-picked instants and would stay green if the driver
stopped stamping reads. They pin that an unread `Framed` reports no
arrival, that each socket read advances the stamp, that PDUs sharing a
read share its stamp rather than being stamped when the caller drains
them, and that a `Framed` rebuilt around leftover bytes reports no
arrival for them, which is the case `ironrdp-tokio`'s split and unsplit
helpers produce. Each was checked by planting the corresponding
regression and confirming the test fails.
- Those live in `ironrdp-testsuite-core` rather than inline because
`ironrdp-async` sets `[lib] test = false`, so an inline `#[cfg(test)]`
module would compile and never run. This adds `ironrdp-async` as a
dev-dependency of `ironrdp-testsuite-core`.
2026-08-19 19:22:10 -04:00
Greg Lamberson c74e7c5c94 fix(pdu)!: accept the full documented range of Client Core Data keyboardType values (#1689)
## Summary

KeyboardType (TS_UD_CS_CORE's keyboardType field, MS-RDPBCGR 2.2.1.3.2)
was a closed enum covering discriminants 1 through 7, transcribed from
the field's other documentation in 2.2.7.1.6 (TS_INPUT_CAPABILITYSET),
which omits value 8 (Korean keyboard). The table this type actually
decodes against, 2.2.1.3.2, documents 1 through 8. Any client outside
the narrower range, including every genuine Korean keyboard, had its
whole Client Core Data parse hard rejected before the connection
started.

Converted KeyboardType to a repr(transparent) struct KeyboardType(pub
u32) with named constants for the eight documented values, mirroring
RdpVersion one field above it in the same struct, and made decode
infallible at all three sites that previously disagreed with each other:
gcc::core_data::client hard rejected, rdp::capability_sets::input
silently dropped to None, and ironrdp-activex's COM setter returned
E_INVALIDARG.

FreeRDP hit the identical gap in its own documentation-only enum until a
two-line fix (FreeRDP#11035). Neither FreeRDP nor xrdp gate connection
admission on this field at all; both decode it as a raw integer.
Windows' own GetKeyboardType additionally documents 0x51 for generic HID
keyboards, which a narrower fix adding only Korean would not survive.

Marked as breaking since KeyboardType's public shape changes for any
downstream consumer of ironrdp-pdu outside this workspace. Note that
cargo-semver-checks in this repo's PR automation only runs against the
facade ironrdp crate, which will not see a break confined to
ironrdp-pdu's own API, so the automated breaking-change label may not
apply here even though this is a real one.

## Validation

cargo xtask check fmt/lints/tests/typos/locks all pass. Extended
ironrdp-activex's existing inline COM boundary test to cover value 8
round tripping and a negative value still being rejected.
2026-08-18 19:05:37 -04:00
Marc-André Moreau 063efcdc30 feat(activex): negotiate monitor topology (#1675)
Negotiate the client monitor layout from UseMultimon and expose the
confirmed remote topology through the ActiveX compatibility interface.

Advertise Monitor Layout PDU support whenever Extended Client Data is
negotiated, and forward layouts from activation, active sessions, and
reactivation so advertised support does not terminate sessions.

Keep fallback reporting truthful when servers do not honor the request,
while preserving single-monitor resize behavior and blocking
multi-monitor resizing.

Do not send Client Monitor Extended Data; per-monitor DPI and
orientation remain unavailable.
2026-08-16 13:42:43 -04:00
Marc-André Moreau 34d7b31dc5 feat(activex): support automatic reconnect (#1662)
Support automatic reconnect through the ActiveX control with bounded
host-approved retries after transport loss.

Reuse ARC cookies only for resumed sessions, reject server ARC status
failures, and report success after active-session traffic.

---------

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-08-14 15:15:03 -04:00
Marc-André Moreau 205fe038cc feat: wire MS-RDPEAI capture into Windows client and ActiveX (#1642)
Add the client MS-RDPEAI capture path on top of hardened RDPSND
playback: connector CFG + static channel wiring, CPAL PCM capture
backend, ironrdp-client --audio-capture, and ActiveX
AudioCaptureRedirectionMode.

PCM capture only accepts encode formats that match the Open capture
stream, rejects non-16-bit capture (Data PDU size contract), and gates
the capture backend behind ironrdp-rdpsnd-native/capture.

Depends on #1648 (playback).
2026-08-13 11:51:24 -04:00
Marc-André Moreau ab48c6cb8c feat(client): add RemoteApp channel support (#1637)
Configure and negotiate RAIL connections, then route its static channel
through the portable client with bounded request queues and server
control events.
2026-08-12 06:46:59 -04:00
Marc-André Moreau 0c3fbe78b4 feat: forward negotiated windowing orders (#1631)
Preserve Window List support during activation.
Forward validated orders through ActiveStage and the raw FFI output.
Desktop and web consumers retain their existing behavior.
2026-08-11 14:59:46 -04:00
irvingouj@Devolutions 5c1816244e feat(rdcleanpath): support Hyper-V connection ordering (#1505)
Hyper-V over RDCleanPath needs PCB → TLS on the proxy, then CredSSP →
X.224 on the client. Ordinary RDCleanPath stays X.224-first.

Still VERSION_1 with the same DER fields. An explicit VMConnect request
carries a Unicode PCB payload in `preconnection_blob` with no X.224; the
proxy encodes the binary PCB. Generic PCB requests keep their existing
X.224-first behavior.

Gateway reference implementation:
[Devolutions/devolutions-gateway#1372](https://github.com/Devolutions/devolutions-gateway/pull/1372)

Checked locally: Rust builds, formatting, Svelte typecheck, and .NET
build. Real nested Hyper-V E2E through Gateway: Native rendered 18
frames, Avalonia connected and rendered its first frame, and Web
rendered a non-empty 1280×720 canvas.

---------

Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
Co-authored-by: Marc-André Moreau <mamoreau@devolutions.net>
2026-08-11 11:42:17 -04:00
Marc-André Moreau 3818b48037 fix(session): batch Fast-Path input events (#1630)
Keep outgoing Fast-Path input frames within the 255-event protocol limit
and preserve their order across FFI.

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>

---------

Co-authored-by: Copilot App <223556219+Copilot@users.noreply.github.com>
2026-08-11 09:41:22 -04:00