AutopilotMonitor/src/Backend/AutopilotMonitor.Functions/Functions/Maintenance
Oliver Kieselbach c287cb3eae Backend: retention and device-history reads fail closed (D-338)
- The retention fanout reads the tenant configuration strictly. A storage
  failure used to yield the synthesized default (90 days), which deletes
  sessions and prunes rows a Pro-365 or never-delete tenant keeps. Now the
  tenant is skipped and counted: tenantsFailed on
  SessionDeletionMaintenanceCompleted, which turns Warning. A row that
  vanished since the tenant listing is skipped too, instead of being
  recreated with defaults.
- GetDeviceHistoryAsync throws on a read failure instead of returning "no
  history". Both writers merge into the chain they read and replace the row,
  so the old behaviour dropped every older ref. The sweep skips such devices
  and leaves the FTR aggregates untouched for that tick.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-09 21:33:29 +02:00
..