Oliver Kieselbach 40323ca57e Bootstrap hardening after a security review, and the MSI channel installs again (D-377)
Findings of a Claude security scan against b4af8c7, each measured first, plus
the MSI channel incident a parallel session found.

- Installer 2.8 extracts the agent ZIP with its own containment check
  (Expand-AgentPayload): every entry is resolved against the payload folder
  before the first write, a rooted or escaping name refuses the package. The
  inbox Expand-Archive of Windows PowerShell 5.1 already refuses such entries
  (measured), so the finding was not exploitable as reported; the guarantee is
  now the script's own, pinned by tests, and Expand-Archive is banned.
- Installer 2.8 also moves PowerShell's own location out of the agent folder
  (Set-Location): on the MSI channel the location pointed at the deleted Msi
  folder and the agent start failed with error 267 since 2.7 went live. When
  the agent program never started, the Agent folder is removed again so a later
  run can install; the stderr line is flattened to one line.
- Run folders younger than an hour stay (a loader may still run there); the
  loader's log is taken only from a run folder that is ours.
- Loader 1.4 (minimum installer 2.8) checks before every download attempt that
  its run folder is still a real folder of ours, opens the download for reading
  before the signature and identity checks and holds it until the run ends, so
  what it checked is what runs and nothing can replace or delete it meanwhile.
- Agent: the protected folder security names Administrators as owner; a folder
  with another owner or a reparse point is not taken as protected, reparse points
  are refused, the base is created protected, install mode protects base and
  Agent and refuses to install when it cannot; every start re-checks both.
- Bootstrap MSI 1.3.0 installs its loader under Program Files, where a standard
  user cannot create the folder first.
- Tests: containment table, hour rule, held handle, owner and junction tests
  (ElevatedFact for the owner assignment), MSI location contract; harness
  scenarios for an escaping package (installer and OOBE script), the hour rule,
  the Program Files layout and an agent that does not start, with the install
  stand-in starting a real program from PowerShell's location. OOBE golden
  regenerated.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
2026-10-22 18:07:51 +02:00
Oliver Kieselbach b4af8c77be Bootstrap integration tests read the publish script's output as text
GitHub Actions runs powershell steps with $ErrorActionPreference = 'stop', and
under Windows PowerShell 5.1 a stderr line of a native process redirected with
2>&1 then ends the test: the three publish refusals failed in CI although the
publish refused as it should. The publish dry runs now start pwsh through
System.Diagnostics.Process like every other scenario. Local run under 'stop':
199 of 199.

[skip actions]: published by a dispatch of publish-scripts.yml, channel dev first.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-22 13:59:45 +02:00
Oliver Kieselbach 3a898b5071 Bootstrap leaves nothing behind: loader 1.3 and installer 2.7 (D-375)
- Loader 1.3 downloads into a protected run folder of its own
  (%ProgramData%\AutopilotMonitor-Loader-<8 hex>), runs the installer only when it
  is signed by the pinned publisher and declares the installer role and version
  2.7 or later, removes the folder after a successful run and never touches the
  agent folder. Unbound arguments now reach the installer by name; the array
  splat bound them by position.
- Installer 2.7 refuses without elevation and decides before it writes: guards
  read HKLM through the 64-bit view (a 32-bit host never saw the deployment
  marker), guard 5 is covered by the agent check. An agent's folder stays as it
  is, a skip without agent removes the folder, an install starts from an emptied,
  protected folder and stages the ZIP in a run folder. It moves the MSI's working
  directory out, writes stderr only on failure and removes the copy older loaders
  left at the fixed path.
- Help texts of both scripts state what customers need; .CHANGELOG, which made
  Get-Help ignore the help, gives way to the Platform Changelog.
- OOBE go-script: the installer's shared helpers, its own elevation check
  (#Requires is ignored under irm | iex), a run folder.
- Publish: version read line-anchored, the loader's own check on the exact
  publish bytes, installers before loaders, -Channel dev (dispatch input).
- Bootstrap MSI 1.2.0; Test-ShouldBootstrapAgent reads the 64-bit view;
  Uninstall removes loader run folders and keeps the Deployed marker.
- Tests: Pester unit suites, an integration harness running the real scripts
  (loader 1.2 and the MSI 1.0 runner frozen in TestData), BootstrapContractTests;
  the gate runs on windows-2022 and windows-2025, once more as SYSTEM, and against
  a real standard user.

[skip actions]: published by a dispatch of publish-scripts.yml, channel dev first.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-22 13:34:54 +02:00